| 1 | Demolition of cement concrete (un reinforced) in ground floors and paving n.exc 15cm thickness (below or above ground (level) and lowering if necessary, removal of the rubbish off the premises complete all as specified and directed. |
| 2 | Demolition of reinforced cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) and removal of the rubbish off the premises complete all as specified and directed. |
| 3 | Demolition of brick work built in CM including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles including removal of the rubbish off the premises complete all as specified and directed. |
| 4 | Materials and labour for flyash brick work with old size bricks straight curved on plan exceeding 6 meter mean radius for manholes /septic tank /soak well etc /in sewer works with old size bricks in CM 1:4. complete all as specified and directed. |
| 5 | All as per BOQ Item No 4.00 here-in-before but except bricks complete all as specified and directed. |
| 6 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soil complete all as specified and directed.Note : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 7 | All as per item No 6.00 here-in-above but depth exc 1.50 m but n.exc 3.00 mtr complete all as specified and directed. |
| 8 | Excavation over area ,not exc 1.5 mtr deep and gatting out in loose/soft soil complete all as specified and directed. |
| 9 | All as per item No 8.00 here-in-above but depth exc 1.50 m but n.exc 3.00 mtr complete all as specified and directed. |
| 10 | Returning, filling in incl spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose soil. |
| 11 | Removing excavated material in soils n exc. 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-2 (40 mm graded stone aggregate) in foundation filling and mass concrete for bottom of manhole and sub base of floor complete all as spd and directed. |
| 13 | Demolition and breaking up drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 150 mm complete all as specified and directed. |
| 14 | Demolition and breaking up drain pipe (SGSW/PVC/RCC etc) set in cement mortar of internal dia of pipe 200 mm complete. |
| 15 | Supplying and laying of PVC underground drainage sewer system pipe bearing 160 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 16 | Supplying and laying of PVC underground drainage sewer system pipe bearing 200 mm dia SN 4 including jointing with couplar, bend tee as per site requirement complete laid in trenches or floors complete all as specified and directed. |
| 17 | Material and labour for cement concrete bed to drain pipe for 200mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 18 | Material and labour for cement concrete bed to drain pipe for 150mm bore of pipe including forming cradles in Cement concrete 1:3:6 Type C2 complete all as specifiedand and as directed. |
| 19 | Taking down cement plaster from inside/outside of existing septic tank/manholes drain and outer surface of bldgsetc incl raking out joints, hacking for key scrubbing down with water and removal rubbish off the premises. |
| 20 | M&L 15 mm thick rendering in cement mortar 1:3 inside including WPC to wall of manhole,drain,bldgs, of brick work/concrete suface even and smooth without using extra cement all as per direction by Engr-in-Charge. |
| 21 | M&L 15 mm thick rendering to outside of wall in cement mortar 1:4 including finish the surface even & fair complete all as specified and directed. |
| 22 | Supply only liquid water proofing compound complete all as specified and directed. |
| 23 | M&L type B-1 1:2:4 (20mm graded stone aggregate) providing RCC precast cement concrete as in cover slab for man hole and similar article with plain face set in cement mortar 1:6. complete all as specified and directed. |
| 24 | M&L for reinforcement cement concrete(nominal mix) type A1 1:1.5:3 (20mm graded aggregate) as in Slabs supported on walls, beams and columns in floors,roofs, landings, balconies, canopies, deck slabs and in shelves and the like for septic tank /soakage well pits slab complete all as spd and directed. |
| 25 | Use and waste of flat formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work, not exceeding200mm thick with for fair and finished surfaces complete all as spd and directed. |
| 26 | Material and labour for 6mm to 8mm dia mild steel TMT bar, cut to length, bent to shape required, incl cranking bending and binding with MS wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed. |
| 27 | M&L TMT bars 10mm dia, and over cut to length bent to shape required including cranking, bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as spd and directed. |
| 28 | Taking down eaves gutters and rainwater/SWR/RCC pipes (any size or pattern), including all fittings, heads, shoes, bends, swan necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories), complete all as specified and directed |
| 29 | S & F for PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc complete all as spd and directed |
| 30 | S & F for PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc complete all as spd and directed. |
| 31 | S & F for PVC (SWR) pipes of 100 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as spd and directed. |
| 32 | S & F for PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as spd and directed. |
| 33 | S & F in repair PVC (SWR) bends any radius of 110 mm bore with access door complete all as spd and directed. |
| 34 | S & F in repair PVC (SWR) bends any radius of 75 mm bore with access door complete all as spd and directed. |
| 35 | S & F PVC (SWR) reducers of 110 mm bore |
| 36 | S & F PVC (SWR) reducers of 75mm bore |
| 37 | S&F 110mm PVC (SWR) vent cowl. |
| 38 | S&F 75mm PVC (SWR) vent cowl. |
| 39 | S&F 110mm PVC (SWR) junction single (simgle T) equal or unequal complete all as specified . |
| 40 | S&F 75mm PVC (SWR) junction single (simgle T) equal or unequal complete all as specified . |
| 41 | S&F in repair 100mm dia CI bends (any radius) with oval access doors complete all as spd and directed. |
| 42 | S&F in repair 75mm dia bends (any radius) with oval access doors complete all as spd and directed. |
| 43 | Fixing only tilted cast iron drain pipes of dia 100 mm by providing clamps made from 1.6 mm thick galvanized M.S Sheet of 30mm width, bent to the required shape and size so as to fit tightly on the socket of the pipe, when tightened with screw bolts. (clamp shall be formed out of two semi-circular pieces, hinged with 6mm dia M S bolt on one side and provided with flanged ends on the other side with hole to fit in the screw bolt and nut, 40 mm long. The clamp shall be provided with a hook made out of 27.5 cm long 10 mm diameter M.S bar , riveted to the ring at the center of one semi circular piece) and fixed to the wall by embedding their hooks in cement concrete block 10 x 10 x 10 cm in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including necessary holes complete all as specified Note : Each Clamp alongwith hole and embeded materials shall be considered as each Job |
| 44 | Fixing only tilted cast iron drain pipes of dia 75 mm by providing clamps made from 1.6 mm thick galvanized M.S Sheet of 30mm width, bent to the required shape and size so as to fit tightly on the socket of the pipe, when tightened with screw bolts. (clamp shall be formed out of two semi-circular pieces, hinged with 6mm dia M S bolt on one side and provided with flanged ends on the other side with hole to fit in the screw bolt and nut, 40 mm long. The clamp shall be provided with a hook made out of 27.5 cm long 10 mm diameter M.S bar , riveted to the ring at the center of one semi circular piece) and fixed to the wall by embedding their hooks in cement concrete block 10 x 10 x 10 cm in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including necessary holes complete all as specified Note : Each Clamp alongwith hole and embeded materials shall be considered as each Job |
| 45 | M&L for Cover /lid for oval access door suitable for 100 mm bore CI bends fixed with bolts and rubber washer including painting with two coats of bituminous paint complete all as specified and directed. |
| 46 | M&L for Cover /lid for oval access door suitable for 75 mm bore CI bends fixed with bolts and rubber washer including painting with two coats of bituminous paint complete all as specified and directed. |
| 47 | Dismantling floor/hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises as directed. |
| 48 | M&L for coloured non skid ceramic tiles 7 to 8 mm thick (Square /rectangular) area of each tile exceeding 0.06sqm but not exceeding 0.11 sqm, in floors etc set and jointed in neat cement slurry and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 49 | M & L Glazed ceramic colour tiles in vertical surface 450x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match and including rendering 10 mm thick cement plaster in CM 1:3 on brick work or concrete surfaces of wall complete all as spd and dircted. |
| 50 | S & F in repairs vitreous china squatting pan, 'Orissa\\" pattern, size 580 mm X 440 mm white with ‘P’ or ‘S” trap, front or back inlet and integral foot rests, any pattern and including fixing , connector to flush pipe, lime concrete bedding and making connections to flush pipe, connector to branch pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 51 | S & F in repairs vitreous china wash down water closet (pedestal pattern), white including thermoplastic seats and covers of grade 2 type, flat with hinging device of bronze or brass with nickel chromium plating, fixing bolt, connector to flush pipe and making connections to flush pipe, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 52 | S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white minimum), with grating and union for discharge pipe(back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. |
| 53 | Supply and fixing in repair 12mm thick glass partition of selected quality frosted / pin headed glass as in partition or urinal partition of required size including stainless steel holding brackets and stainless steel screws to secure complete all as directed by Engineer-in-charge |
| 54 | S&F in repair 32 mm bore Waste coupling of PTMT (half or full threaded) (Minimum weight 32mm45gms) for urinal complete all as specified and directed. |
| 55 | S&F in repair for PVC waste pipe 32mm dia for wash basin/urinal (length- 1 RM) complete all as spd and directed. |
| 56 | Supply and fixed in repairs floor mounted (single piece WC) bowl with cistern for coupled WC with and including UF soft close slim seat cover, hinges, dual flush cistern fitting, fixing accessories and accessories set complete of size 380x655x765 mm with S Trap- 250 mm, connector to branch soil pipe and anti syphonage pipes etc. including sealing the joints and making leak proof using sealant complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Supply and fixed in repairs vitreous china one piece wall mounted toilet seat with UF seat cover, hinges, fixing accessories set , cistern fittings pattern white of size Size=380x650x730mm including trap fixed in position complete all as specified. |
| 58 | S& F in repair water closet seat cover white coloured pattern with flat bottum and cover and mild steel chromium plated or aluminium hinging devised for any size any type complete all as spd and directed. |
| 59 | Fixing only 10 litre capacity PVC low level flushing cistern with all accessories complete fixed with WC including syphone pipe, PVC flushing pipe of size complete (w/o brackets). |
| 60 | S & F in repair flush pipe of polyethylene of low or high density of PVC, 32 mm dia, for low level cistern complete all as specified and directed. |
| 61 | S & F in repair grating square 150mm size of PTMT (minimum 100 gms) complete all as specified and directed. |
| 62 | M & L extra for forming fair finish drain channel 30 cm inner grith in cement concrete using extra cement |
| 63 | M & L for cement concrete type B-0 1:2:4 (12.5mm graded stone aggregate) in cills, steps, plinth courses, string courses, lacing courses, parapets, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed rounded or chamfered on edges all as specified. |
| 64 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified |
| 65 | Material and labour for 25 mm thick chequered cement concrete tiles of size 300x300mm set ,jointed and pointed using with grey cement and pigment in floors, pavings etc including the setting and jointing in neat cement plaster or slurry 3 kg/sqm over 20mm thick screed bed or bedding layer in cement mortar 1:6 complete all as per specification. |
| 66 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 15 mm dia bore complete all as specified and directed. |
| 67 | Fixing only 15mm dia bore old steel tubing after necessary cleaning, with and including all new tube fittings (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions, etc.) and fixing complete with clips, wall hooks, wooden plugs, or laying in trenches, etc and necessary connections in old position (Walls, ceiling, floors, etc.) complete all as specified and as directed |
| 68 | S&F 16 mm outer dia medium grade CPVC, SDR 11 & plain CPVC SDR 11 with all fittings (brass inside the fittings) and fixed complete to walls and ceiling or laid in floors complete all as specified and directed. |
| 69 | Uprooting of plants of any girth from RCC/Brick surfaces, pouring of acid chemical over root and making good in CM 1:3 or PCC 1:2:4 type B0 using 12.5mm graded aggregateincludingall accessories to reach the area of plant growth in buildings etc complete all as specified and directed. |
| 70 | Cutting into existing manholes 150mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete. |
| 71 | Cutting into existing manholes 200mm dia pipe for connecting new drains making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished and reforming benching as required complete. |
| 72 | Surface dressing in any type of soil not exc 15 cm deep in foul condition for removing heaps of wastes, cleaning of flora, fauma, foliage and bushes around septic tanks, soakage well, manholes and along sewage line and removing debris/heaps of bushes etc from vicinity and depositing at a place where directed by Engr-in-charge |
| 73 | Cleaning and desilting of sewage lines upto 150mm dia and depth up to 1.50m, cleaning the lines by manual roding/mechanically jet pumps/sewage cleaning machine as per rule 5 and protective gear and safety devices as per rule 4 of the Prohibition of Employment as Manual Scavengers and their Rehabilitation Rules, 2013 and removing blockage and flushing out by means of pumping out/removing liquid waste/sewage, plugging the ends pipes or diverting the flow into drains if necessary, removing silt sludge etc, sprilinkling bleaching powder on the silt to avoid smell including all precautionery and saftey measures such as saftey belts, ligthting arrangement face mask gloves etc and removing the same (silt, sludge & other waste material) in leak proof trucks covered with tarpoline to out side of MoD land as per existing rules and regulation of civil authorities and flushing the sewage lines with fresh water complete all as specified and as directed. Unit rate quoted shall deemed to be included of cleaning of shrubs, grass small roots etc. around the Manholes, Inspection chamber etc and along sewage lines wherever required or as directed and no extra payment shall be made on this account) |
| 74 | All as per item No, 73.00 here-in-before but dia exceeding 150mm to 300mm complete all as specified and directed. |
| 75 | Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW or SG pipes) , house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of all solid or liquid wastage to make the entire system functional as directed by Eng-in-Charge Note :-(i) contractor will deploy three SDA mazdoor, daily to attend day to day complaint as mentioned above. SDA mazdoor will report daily at AGE B/R-I Subdivision at 0830 hrs and depart 1700 hrs after attending all complaints. I n case of non attending complaints in same day , recovery @ RS 250 per complaints will be recovered from contractor and in case of Non deployement od SDA Mazdoor recovery @ RS 400/y shall be made from the contractor Please Enable Macros to View BoQ information |
| 76 | Cleaning of blockage of existing sewage system and plumbing system (Comprising of sewer line in CI, SGSW or SG pipes) , house connection from WC, bath, Kitchen etc including gully traps, floor/Nahani traps, CI Pipes and plumbing work etc of any description and in any position below or above ground level, located in different situations to remove of all solid or liquid wastage to make the entire system functional as directed by Eng-in-Charge Note :-(i) contractor will deploy three SDA mazdoor, daily to attend day to day complaint as mentioned above. SDA mazdoor will report daily at AGE B/R-I Subdivision at 0830 hrs and depart 1700 hrs after attending all complaints. I n case of non attending complaints in same day , recovery @ RS 250 per complaints will be recovered from contractor and in case of Non deployement od SDA Mazdoor recovery @ RS 400/y shall be made from the contractor Please Enable Macros to View BoQ information |