| 1 | BoQ BOQ Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GARRISON ENGINEER TEZPUR (NORTH) NAME OF WORK : REPAIR/ REPLACEMENT SEWAGE LINE, EXTERNAL DRAINAGE, SEPTIC TANKS, SOAK WELL, MANHOLES, BRICK RETAINING WALL, BOUNDARY PILLARS, PAVINGS, DRAINGAE, FOOTPATH, CULVERT, HARD STANDING, INTERLOCKING TILES AND OTHER ALLIED WORK SECT I TO XI AT AGE CHARDUAR UNDER GE(N) TEZPUR Contract No : GE(N)/TEZ/ OF 2026-2027 (File No. 8256/E8) Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Description of items of works Item Code / Make Approx No. of quentity required. Units Pre Priced Rate (in. Rs.) as Defined by MES Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures to be entered by the Bidder Rs. P. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT (In INR) TOTAL AMOUNT With Taxes TOTAL AMOUNT (In Words) |
| 2 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable, drain, GI pipe etc complete all as specified and directed.specified |
| 3 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and exc. 1.5 metre but not exc 3.0 m in depth and getting out for taking up / laying under ground electric cable, drain, GI pipe etc complete all as specified and directed.specified |
| 4 | Returning filling in incl spreading levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.specified |
| 5 | Removing excavated material not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point in soils complete all as specified and directed.specified |
| 6 | M&L for precast RCC 1: 2 :4 type B-1 (using 20mm graded crushed stone aggregate) as in manhole covers, set in cement mortar 1:4 including necessary formwork and demolition of old unserviceable existing concrete work complete all as specified and directed. |
| 7 | Demolition/Breaking up Drain Pipes (Salt Glazed Ware) 150mm Bore (dia), Jointed in Cement Mortar of any description including PCC of Packing and Haunching to Sides of the Pipes with Bed, complete all as specified and as directed. |
| 8 | M&L for concrete bed for sewer line packing under and haunching against the sides of the new pipes with PCC (1:3:6) type C-2 with (using 40 mm graded crushed stone aggregates) for upto 100 mm dia (Internal) of sewer pipe lines complete all as specified and directed. |
| 9 | Cleaning 10 USERS Septic Tank by opening Cover, Pumping out Sewage Water and Taking out accumulated Night Soil, Sludge’s, Brick Bats or any Other Items, (both Solid and Liquid) through only \\"Honey sucker /sewage vacuum suction machine\\" min capacity 4.0 cum including dewatering of manholes, sewage pipe line ,septic tanks, drain, soakage well when ever is required and removing to a distance exc 50.00 METRE but not exc. 100.00 METRE, and buried under Ground (minimum 300 mm below Ground Level), Sprinkling Bleaching Powder on deposited Sludge’s at Pit including Excavation of Pits, Returning, Filling in and dress-ing of Surplus Soil/Ground to Slope as required, again Spreading Bleaching Powder on Filled Earth and upto 1.00 METRE around the Trenches/Pit not less than 500 GRAMS PER SQUARE METRE, re-fixing the Cover after complete Cleaning of Septic Tank, complete all as specified and as directed. Note: The contractor shall upload scanned copy of the original purchase voucher of Honey sucker machine /sewage vacuum suction machine obtained from manufacturer/authorized dealer or affidavit for agreement between bidders & owner of machine for hiring of machine. |
| 10 | All as per item No. 9 ditto but for 25 users complete all as specified and as directed. |
| 11 | All as per item No. 9 ditto but for 50 users complete all as specified and as directed. |
| 12 | All as per item No. 9 ditto but for 100 users complete all as specified and as directed. |
| 13 | All as per item No. 9 ditto but for 250 users complete all as specified and as directed. |
| 14 | All as per item No. 9 ditto but for 500 users complete all as specified and as directed. |
| 15 | Cleaning Manhole depth not exc. 0.50 METRE by opening Cover and Taking out accumulated Brick Bats, Garbage, Silts or any Other Items, through Honey sucker machine/Pneumatic tools removing and carrying same to a distance exc. 50.00 METRE but not exc. 100.00 METRE and buried under Ground (minimum 300mm below Ground Level) including Excavation of Pits and Returning, Filling in and Dressing of Surplus Soil Ground to Slope if required, re-fixing the Cover after Cleaning of Manhole, complete all as specified and as directed. |
| 16 | All as per item No. 15 ditto but for depth of manhole exc 0.50m and not exc 1.0m complete all as specified and as directed. |
| 17 | All as per item No. 15 ditto but for depth of manhole exc 1.0m and not exc 2.0m complete all as specified and as directed. |
| 18 | All as per item No. 15 ditto but for depth of manhole exc 2.0m and not exc 3.0m complete all as specified and as directed. |
| 19 | Cleaning Gully Trap (Manhole Type) depth not exc. 0.50 METRE by Opening Cover and Taking Out accumulated Night Soil, Sludges, Brick Bats or any Other Items, removing and carrying same to a distance exc. 50.00 METRE and not exc. 100.00 METRE and buried under Ground (minimum 300mm below Ground Level), re-fixing the Cover after Cleaning of Gully Traps including Excavation of Pits and Returning, Filling in and Dressing of Surplus Soil, Ground to Slope if required, complete all as specified and as directed. |
| 20 | All as per item No. 19 ditto but for depth of gully trap exc 0.50m and not exc 1.0m complete all as specified and as directed. |
| 21 | Cleaning 150/110 mm dia bore sewage line by Roding from Manhole, Septic Tank, Gully Trap etc and well flushing with water, complete all as specified and as directed. |
| 22 | M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.18sqm but not exceeding 0.36 sqm,above 15mm thick screed bed or bedding layer in cement mortar (1:6) for laying floor/roof finishes in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of old unserviceable existing tile work complete all as specified and as directed. |
| 23 | M&L for non skid ceramic colour tiles, 7 to 8 mm thick, area of each tiles exc 0.06sqm but not exc 0.11 sqm squre / rectangular in floor set and jointed in neat cement slurry and pointed in cement mixed with colour pigment to match over 15 mm thick screed bed or bedding layer in cement mortar(1:4) as in floors for receiving tiles including dismantling of old unserviceable existing tile work complete all as specified and as directed. |
| 24 | M&L Non-skid joint free coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceding 0.18sqm but not exceeding 0.36 sqm, in skirting/dado etc & rendering 10mm thick on brick or concreteor stone surfaces in cement mortar (1:4) as in screed bed/backing coat for laying set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of old unserviceable existing tile work complete all as specified and as directed. |
| 25 | M&L coloured glazed ceramic tiles of size 300x200x7 or 350x250x7mm or 450x350x7 mm thick, in vertical surfaces, skirting etc with rendering 10mm thick on brick or concreteor stone surfaces in cement mortar (1:4) as in screed bed/backing coat for laying set and jointed in neat cement slurry and pointed in white or coloured cement to match including dismantling of old unserviceable existing tile work complete all as specified and as directed. |
| 26 | M&L for 25 mm thick cement concrete (1:2:4) type B1 ( 20mm graded crushed stone aggregate) as in floor finished rough to receive floor finishes including demolition of old unserviceable existing cement concrete complete all as specified and directed. |
| 27 | M & L Hardcore of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15mm thick watered and rammed to true surface using broken stone aggregate complete all as specified and directed. |
| 28 | M & L for 100mm thick cement concrete type B2, 1:2:4 (using 40mm graded crushed stone aggregate) as in hard standing and making finished even and smooth without using extra cement including demolition of old unserviceable existing cement concrete complete all as specified and directed. |
| 29 | M&L for 25mm thick pre-polished and chemically treated anti skid exterior grade coloured chequered tile of size 30cm X 30cm 25mm as in path with grey cement and pigments including dismantling of old unserviceable complete all as specified and as directed.Note:- Design/pattern shall be as approved by GE at the time of execution. |
| 30 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness &size/shape, made by table vibratory method using PU mould, laid in required colour &pattern over and including 50mm thick comnpacted bed of fine sand, compcting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plkate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as per specified and directed. |
| 31 | M&L PCC 1:3:6 type C1 using 20 mm graded crushed stone aggregate as in coping, kerbs and the like including weathering, slightly rounded or chamfered angles and throating, including demolition of old unserviceable existing cement concrete complete all as per specified and directed. |
| 32 | M & L for 75mm thick cement concrete type C2, 1:3:6 (using 40mm graded crushed stone aggregate ) as in foot path/plinth protection or similar and making finished even and smooth without using etra cement including demolition of old unserviceable existing cement concrete complete all as per specified and directed. |
| 33 | M&L RCC type B1 (1:2:4) using 20 mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, blaconies, canopies, deck slabs and in shelves and the like including demolition of old unserviceable existing cement concrete complete all as per specified and directed. |
| 34 | M&L for TMT bars, 10 mm dia and over cut to length, bent to shape required including cranking ,bending spirally, hooping for columns, hookings/ends and binding with and including MS wire not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 35 | Use and Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings & similar work; exc. 200m thick (Horizontal or sloping) Fair finished surfaces of concrete flat complete all as per specified and directed. |
| 36 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan exc 6 m mean radius built in cement mortar ( 1:6) including demolition of old un serviceable existing brick work complete all as per specified and directed. |
| 37 | M&L for Brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:6 including demolition of old un serviceable existing brick work complete all as per specified and directed. |
| 38 | M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brickwork or concrete surfaces and finishing the surface even and smooth without using extra cement including taking down of old unserviceable existing plaster complete all as specified and as directed. |
| 39 | M&L for 5mm thick rendering in cement mortar (1:3) on concrete surfaces, in ceiling,and finishing the surface even and smooth without using extra cement including taking down of old unserviceable existing plaster complete all as specified and as directed. |
| 40 | M&L for rendering 15mm thick plaster in two layers (i.e. 10mm and 5mm) in CM (1:4) mixed with water proofing compound 200ml per bag of cement on top layer finished on fair face of brick or concrete surface finished including taking down of old unserviceable existing plaster complete all as specified and directed.Note:- WPC shall be measured and paid seperately under respective item of BOQ. |
| 41 | Supply only liquid water proofing compound conforming to IS: 2645 - 1975 specification complete all as specified and directed. |
| 42 | S&F in repairs Bib taps fancy type, long body brass chromium plated for 15mm bore pipe, screwed for iron pipes or for brass ferrule complete all as specified and dierected. |
| 43 | S&F in repair 15mm bore chromium plated stop valves, cast copper alloy screwed down, high pressure with crutch or butterfly handle, screwed both ends for steel pipe for unions complete all as specified and directed. |
| 44 | S&F in repair 15mm bore stop valves, chromium plated, with Long shank and cup (concealed type), cast copper alloy, screwed down, high pressure with capstan head, screwed for steel pipe or brass ferrule complete all as specified and directed. |
| 45 | S&F in repairs plastic water closet seat cover, white / black, with mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 46 | Supply and fixed for hoisting rotational moulded polyethelene (double layer) water storage tanks 500 ltrs capacity (cyclindrical vertical with polythene foam insulation as intermediate layer), ISI marked (IS: 12701: 1996) hoinsted and fixed in position including inlet, outlet and over flow connections ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 455 gms) complete screwed for 25 mm bore dia in position etc including taking down of old unserviceable existing tank of any capacity complete all as specified and directed. |
| 47 | Supply and fixed for hoisting rotational moulded polyethelene (double layer) water storage tanks 1000 ltrs capacity (cyclindrical vertical with polythene foam insulation as intermediate layer), ISI marked (IS: 12701: 1996) hoinsted and fixed in position including inlet, outlet and over flow connections ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 455 gms) complete screwed for 25 mm bore dia in position etc including taking down of old unserviceable existing tank of any capacity complete all as specified and directed. |
| 48 | S&F in repair ball brass valves high pressure, with polythene float and fly nut complete screwed for iron pipe or for brass ferrule and fixed 20 mm bore dia of pipe complete all as specified and as directed. |
| 49 | S & F in repairs 15 mm bore pillar taps, Cast Copper alloy, with capstan heads, chromium plated, screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe. complete all as specified and as directed. |
| 50 | S&F in repair vitreous china wash down water closet pan (Pedestal pattern), white, including fixing bolts nut & plastic water closet seat back excld flushing cistern and flush pipe, including taking down unserviceable water closet pan complete all as specified and directed. |
| 51 | S&F in repair vitreous china squating pan orissa pattern size 580X 440mm white with intregal foot rest complete including lime concrete (excluding flushing cistern and flush pipe) but connecting to flushing pipe, anti-symphonage pipe etc. complete all as specified and directed. |
| 52 | S&F in repair 10 ltr capacity PVC valveless syphone action type, flushing cistern low level, white with inlet, ball valve float and handle incl brackets with PVC high flush pipe complete all as specified and directed. |
| 53 | S&F in repair Vitreour china WHB size 550 x400 mm (Flat back or angle back type) white with 32 mm dia brass CP Waste fittings , galvanised iron light grade 32 mm bore waste pipe, a pair of CI brackets duly painted/erecting stand incl cutting and pinning in ends making good disturbed surfaces in cm 1:3 incl taking down u/s WHB and connected items, complete all as specified and directed. |
| 54 | S&F in repairs of Chromium plated over head shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed. |
| 55 | S&F in repair looking mirror 600mm x 450mm of selected quality 5 to 6mm thick glass mounted with glass shelf assembly with CP rails fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 56 | S&F in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 57 | S&F in repair Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe over all size 915 mm x 460 mm and bowl size 410 mm x 330 mm x 160 mm complete all as specified and directed. |
| 58 | S&F in repair 15mm size PVC connection pipe with PTMT nut of length 450mm complete all as specified and directed. |
| 59 | S&F in repair 15 mm size PVC connection pipe with PTMT nuts of length 600 mm complete all as specified and directed. |
| 60 | S&F in repair waste pipe of dia 32 mm complete all as specified and as directed. |
| 61 | S&F in repair 32 mm Waste coupling of PTMT (half or full threaded, Minimum weight 32mm- 45gms/40mm-60 gms) complete all as specified and directed. |
| 62 | S&F in repair 32 mm Bottle trap of PTMT having minimum water seal of 25mm .(Minimum weight 32mm-260gms/ 40mm-270 gms) complete all as specified and directed. |
| 63 | S&F in repair Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and directed. |
| 64 | S&F in repairs Towel Rail 600 long chromium plated, including all necessary fittings, connections etc. complete all as specified and directed. |
| 65 | S&F in repair PVC (SWR) Floor trap of 75 mm outlet plain with grating including jointing with solvent cement complete all as specified and directed. |
| 66 | S&F in repair PVC (SWR) gully trap of 125/ 110 mm setting and jointing with solvent cement complete all as specified and directed. |
| 67 | S&F in repairs PVC (SWR), 110mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 25mm x 3mm including nuts bolts etc, complete all as specified and directed. |
| 68 | S & F in repair 110MM PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 69 | S&F in repairs PVC (SWR), 75mm bore, single socketed in any length with rubber ring joints, fixed to walls with MS clamps made out of flat iron of size 20mm x 3mm including nuts bolts etc, complete all as specified and directed. |
| 70 | S & F in repairs 75mm PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 71 | S & F PVC (SWR) bends of radius 110mm bore complete all as specified and as directed. |
| 72 | S & F in repairs PVC (SWR) bends of radius 75mm bore complete all as specified and as directed. |
| 73 | S & F in repairs PVC (SWR) junction single,(Single T) equal or unequal of radius 110mm bore complete all as specified and as directed. |
| 74 | S & F in repairs PVC (SWR) junction single,(Single T) equal or unequal of radius 75mm bore complete all as specified and as directed. |
| 75 | S&F in repairs 110mm dia PVC(SWR) junction single, (single T) equal or unequal with access door complete all as specified and as directed. |
| 76 | M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of white wash complete in all respect as specified and directed. |
| 77 | M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots , washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of exterior grade weather coat paint white or coloured complete in all respect as specified and directed. |
| 78 | M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of colour wash complete in all respect as specified and directed. |
| 79 | M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of acrylic based oil bond distemper complete in all respect as specified and directed. |
| 80 | M&L for preparation of plastered or unplastered old decorated surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying one coat of cement based paint complete in all respect as specified and directed. |
| 81 | M&L for preparation of newly plastered surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying two coat of white wash complete in all respect as specified and directed. |
| 82 | M&L for preparation of newly plastered surfaces of walls, by smole soot, moulds, moss and efflorescence salts and trading oil and greasy spots, washing with water all as specified, filling cracks/ hole by applying wall care putty and applying two coat of cement based paint complete in all respect as specified and directed. |
| 83 | M&L for preparation of new or previously untreated steel and Iron surface of any description, not otherwise described over 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 84 | M&L for preparation of new or previously untreated steel and Iron surface of any description, not otherwise described not 10 cm width or girth and applying two coats of Synthetic enamel paint over one coat of red oxide primer complete all as specified and directed. |
| 85 | S & F Rolled Mild Steel sections confirming to Fe 410 - W (Gde - E - 260) Quality - A as in rafters, verticals, purlins where connected to common rafters fixed with angle cleats or other connecting plates complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |