| 1 | Taking down of ACSR conductor of any specification complete all as specified and as directed |
| 2 | Dismantling steel poles/ struts, any size |
| 3 | Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 mtr depth for laying cable at and getting out in soft/ loose soil all as specified and directed. |
| 4 | Excavation in trenches not exceeding 1.5 Mtr wide and exceeding 1.5 mtr depth up to 3 mtr for laying cable at and getting out in soft/ loose soil all as specified and directed. |
| 5 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers, not exceeding 25 cm thick all as specified and directed |
| 6 | Removing surplus soil to a distance not exceeding 50 Mtr and deposited at a level not exceeding 1.5 mtr above from the starting point all as specified and directed. |
| 7 | M & L PCC 1:2:4 type B1 using 20 mm graded stone aggregate coping of poles including forming work complete all as specified |
| 8 | M & L PCC 1:3:6 type B2 using 40mm graded stone aggregate in foundations of poles, filling and mass concrete complete all as specified. |
| 9 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of following sizes: |
| 10 | 185sqmm 3.5core |
| 11 | 150sqmm x 3.5core |
| 12 | 120sqmm 3.5core |
| 13 | 95sqmm 3.5core |
| 14 | 70sqmm 3.5core |
| 15 | 50sqmm 3.5core |
| 16 | 35sqmm 3.5core |
| 17 | 25sqmm 3.5core |
| 18 | 10sqmm 4 core |
| 19 | Supply and laying in trenches of 50 mm outer dia DWC HDPE pipe, Heavy Duty, conforming to IS 14930 Part 2, made of HDPE, with corrugated outer wall and smooth inner bore, suitable for passing 1.1 kV, 4C x 10 sqmm to 3.5C x 35 sqmm XLPE cable, including cost of couplers, jointing accessories, end caps, and laying as per site requirement Complete all as specified and directed by Engr-in-Charge direction. Make: SFMC, Reliance, Supreme. |
| 20 | All as per item No. 10.00 above 63 mm dia |
| 21 | All as per item No. 10.00 above 110 mm dia |
| 22 | All as per item No. 10.00 above 150 mm dia |
| 23 | M&L for cutting of road / hard standing up to a size not exceeding 20cm in width and not exceeding 60cm in depth for laying of LT UG cable/ protection pipe line making good the disturbed portion so as to match existing finishing with PCC 1:2:4 type B1/ cement mortar in CM (1:2) Complete all as specified and directed. |
| 24 | S&F Galvanised steel tubing, light grade with all fittings fixed complete to walls, poles, ceiling or laid in floors/ trenches/ road crossing/ beside steel tubular poles for the protection of cable for the following sizes all as specified and as directed. |
| 25 | 40 mm bore |
| 26 | 80 mm bore |
| 27 | 100 mm bore |
| 28 | Supply, installation, testing and commissioning of powder coated compartmentalized cubical LV panel (LTP-1) outdoor type double door fabricated out of 3mm thick CRCA sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50 Hz, 3 Phase, 4 wire AC supply complete with gland plates, Cable glands, lifting hooks, ventilating louvers, bus bars, inter connection, earthing, labelling electrical interlocking, suitable for termination of cables, mounted/ fixed on and including MS angle iron stand/ frame 40cm height from FFL, fabrication out of 50x50x6mm thick MS angles duly grouted in PCC 1:3:6 foundation, including supply and fixing of following switch gear and accessories in the panel, complete as required. The panel should be manufactured by CPRI approved panel maker and having protection of IP-65 . |
| 29 | 1) Incomer: (i) MCCB 250 Amp 4 pole 25 KA with thermal magnetic release - 1 nos (ii) Digital type multifunction meter - 1 Nos. (iii) 01 set of phase indicating lamp with MCB2) (i) Outgoing MCCB TP 160 Amps, 415 Volts AC 16 KA - 01 Nos (For sub-LT panel)(ii) Outgoing MCCB TP 40 Amps 415 Volts AC 16 KA - 05 Nos (iii) Outgoing MCCB TP 25 Amps 415 Volts AC 16 KA - 01Nos (For street lights)(iv) Astro Timer Legrand cat No. 4126 54 or equivalent in L&T with Duty contactor ML3 40A for street lights- 01Nos BUSBARS : (I) Electrolytic Copper bus bars with PVC colour sleeved 400 Amps capacity complete all as specified & directed. Make of Panel and Switchgear: Siemens, Schneider, L & T, ABB, Legrand |
| 30 | Supply, installation, testing and commissioning of powder coated compartmentalized cubical LV panel (LTP-2) outdoor type double door fabricated out of 3mm thick crca sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50 Hz, 3 Phase, 4 wire AC supply complete with gland plates, Cable glands, lifting hooks, ventilating louvers, bus bars, inter connection, earthing, labelling electrical interlocking, suitable for termination of cables, mounted/ fixed on and including MS angle iron stand/ frame 40cm height from FFL, fabrication out of 50x50x6mm thick MS angles duly grouted in PCC 1:3:6 foundation, including supply and fixing of following switch gear and accessories in the panel, complete as required. The panel should be manufactured by CPRI approved panel maker and having protection of IP-65 . |
| 31 | 1) Incomer: (i) MCCB 200 Amp 4 pole 25 KA with thermal magnetic release - 1 nos (ii) Digital type multifunction meter - 1 Nos. (iii) 01 set of phase indicating lamp with MCB2) (i) Outgoing MCCB TP 100 Amps, 415 Volts AC 16 KA - 01 Nos (For Bus bar chamber near P-3)(ii) Outgoing MCCB TP 63 Amps, 415 Volts AC 16 KA - 02 Nos (iii) Outgoing MCCB TP 40 Amps, 415 Volts AC 16 KA - 04Nos BUSBARS : (I) Electrolytic Copper bus bars with PVC colour sleeved 300 Amps capacity complete all as specified & directed. Make of Panel and Switchgear: Siemens, Schneider, L & T, ABB, Legrand |
| 32 | Supply, installation, testing and commissioning of powder coated compartmentalized cubical LV panel (Sub-LT Panel) outdoor type double door fabricated out of 3mm thick crca sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50 Hz, 3 Phase, 4 wire AC supply complete with gland plates, Cable glands, lifting hooks, ventilating louvers, bus bars, inter connection, earthing, labelling electrical interlocking, suitable for termination of cables, mounted/ fixed on and including MS angle iron stand/ frame 40cm height from FFL, fabrication out of 50x50x6mm thick MS angles duly grouted in PCC 1:3:6 foundation, including supply and fixing of following switch gear and accessories in the panel, complete as required. The panel should be manufactured by CPRI approved panel maker and having protection of IP-65 . |
| 33 | 1) Incomer: (i) MCCB 160 Amp 4 pole rating 16 KA with thermal magnetic release - 1 nos (ii) Digital type multifunction meter - 1 Nos. (iii) 01 set of phase indicating lamp with MCB2) (i) Outgoing MCCB TP 40 Amps, 415 Volts AC 16 KA - 07 Nos BUSBARS : (I) Electrolytic Copper bus bars with PVC colour sleeved 250 Amps capacity complete all as specified & directed. Make of Panel and Switchgear: Siemens, Schneider, L & T, ABB, Legrand |
| 34 | S&F Weather proof outdoor bus bar chamber, made out of 3 mm thick MS sheet duly powder quoted comprising 4 Nos aluminium strips each of 125 Amps, 60cm long duly insulated mounted on insulators including MCCB 125 Amp with 4 No’s mounting legs made out of 25mm x 25mm x 6mm angle iron grouted in PCC block of size 30cm x 30cm x 90cm (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with suitable size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points including excavation and earth work, returning filling and removal of surplus soils complete all as specified and directed. Make of Panel and Switchgear: Siemens, Schneider, L & T, ABB, Legrand |
| 35 | Supply, installation, testing and commissioning of powder coated compartmentalized cubical LV panel(Main Panel) outdoor type double door fabricated out of 3mm thick crca sheet steel weather proof vermin proof and suitable for operation on 415 volts, 50 Hz, 3 Phase, 4 wire AC supply complete with gland plates, Cable glands, lifting hooks, ventilating louvers, bus bars, inter connection, earthing, labelling electrical interlocking, suitable for termination of cables, mounted/ fixed on and including MS angle iron stand/ frame 40cm height from FFL, fabrication out of 50x50x6mm thick MS angles duly grouted in PCC 1:3:6 foundation, including supply and fixing of following switch gear and accessories in the panel, complete as required. The panel should be manufactured by CPRI approved panel maker and having protection of IP-65 . |
| 36 | 1) (I) Incomer: MCCB 400 Amp 4 pole 36 KA with thermal magnetic release :- 1 nos (ii) Digital type multifunction meter :- 1 Nos. (iii) 01 set of phase indicating lamp with MCB2) (i) Outgoing MCCB TP 160 Amps, 415 Volts AC 25 KA - 04 Nos (ii) Outgoing MCCB TP 32 Amps, 415 Volts AC 16 KA - 01 Nos(For street lights)(iii) Astro Timer Legrand cat No. 4126 54 or equivalent in L&T with Duty contactor ML3 40A for street lights- 01Nos (iv) 3 Phase Energy meter, 415V, 50Hz of suitable CT ratio -01 Nos BUSBARS : (I) Electrolytic Copper bus bars with PVC colour sleeved 500 Amps capacity complete all as specified & directed. Make of Panel and Switchgear: Siemens, Schneider, L & T, ABB, Legrand |
| 37 | M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. all as specified and directed by Engineer- in - charge Please Enable Macros to View BoQ information |
| 38 | M & L for earthing complete with galvanized steel earth plate electrode of 60 cm X 60 cm X 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized strip of size 32 mm X 6 mm as earth lead by means of bolts, nuts, checknuts and washers of galvanized iron or steel, galvanized iron pipe of 40 mm diameter connected to earthing test point, all as shown in electrical plate No. 5, connected to earthing test point including testing on completion, excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep with a 10 mm deep CI cover hinged to CI frame on ground level, GI watering pipe, funnel, etc. all as specified and directed by Engineer- in - charge Please Enable Macros to View BoQ information |