| 1 | M&L for PCC type C1,1:3:6 using 20mm graded crushed stone agg,in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 2 | Supply only integral water proofing compound liquid grade conforming to IS-2645 complete all as specified and directed. (Pidiproof of Dr.fixit or equivalent) |
| 3 | M&L for brickwork with old size fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed. |
| 4 | M&L for brickwork with old size fly ash bricks, straight or curved on plan to any radius as in half brick thick walls, built in cement mortar 1:4 complete all as specified and directed. |
| 5 | M&L for 20mm thick Granite (of any type) work(table rubbed and polished) for wall lining (veneering to wall) in cement mortar(1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 6 | S&F 30mm thick 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (with sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed. |
| 7 | S&F 30mm thick factory made flush shutter, solid core construction with block board core and plywood face panels, commercial type on both sides kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 8 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) area not exc. 1.5sqm each, including cutting holes for removing the hold fast,making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 9 | Taking down chowkat or frame with shutter (without taking off shutter from the frame) exc. 1.5 sqm and n.exc 4 sqm each, including cutting holes for removing the hold fast, making good disturbed surfaces and removing materials from site of work complete all as specified and directed. |
| 10 | Taking down old unserviceable shutters of any description exc 1.00 but n.exe 2.00 Sqm each complete all as specified and directed. |
| 11 | S&F Factory Made Solid PVC Moulded Door Shutter with wood free EPS , 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and directed. |
| 12 | S&F Solid PVC frame (Single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffner and fixed with 100 x 8 sheet metal CSK screws complete all as specified and as shown on drawing.(Note :- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life) complete all as specified and directed. |
| 13 | S&F 100mm Brass barrel tower bolts, with cast or sheet barrel and rolled or cast bolts and fixed complete all as specified and directed. |
| 14 | S&F 150mm aluminium anodised barrel tower bolts of extruded section complete all as specified and directed. |
| 15 | S&F 250 mm long aluminium alloy, anodised,sliding door bolt with hasp,staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and direcetd. |
| 16 | S&F 100mm Butt hinges,medium weight, cold rolled mild steel, complete all as specified and directed. |
| 17 | S&F 100mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 complete all as specified and directed. |
| 18 | S&F 150mm size Extruded brass handles, fabricated type polished complete all as specified and directed. |
| 19 | S&F 150mm size aluminium handle cast type complete all as specified and directed. |
| 20 | M&L for Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 21 | S&F roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe -410-W(Gde-E-250) quality-A. complete all as specified and directed. |
| 22 | M&L for 1.25mm thick pressed steel door frame of size 105mm x 60mm with one or more rebates including necessary fixing lugs , hinges, lock strike plate etc complete all as specified and directed. |
| 23 | S&F for 1.25mm thick pressed steel frames 125mm x 60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate,etc.complete all as specified and directed. |
| 24 | M&L for anodised aluminium snap grid (SIZE-605x605MM) frame work for false ceiling complete all as specified and directed. |
| 25 | S&F of Gl frame work of Size of grid 605 x 605mm for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. |
| 26 | S&F Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed. |
| 27 | S&F Pre- painted coloured trapezoidal profiled Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP x RW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 28 | S&F Pre- painted coloured plain sheet Galvalume/ Zincalume sheet with min thickness 0.50mm TCT confirming to IS - 513(AZ-150 GSM, Al Zn allay metalic coating with 550 Mpa yield stress as per AS-1397) as in roof covering/cladding to wall, fixed with self tapping screws colour exterior coat of silicon modified polyster/BHP/ XRW paint system 20 micron top coat applied over 5 micron primer and 5 micron polyster back coat applied over 5 micron primer , all fixed with galvanized self drilling self tapping fastner (12-14 x 55 with EPDM seals) complete all as specified and directed. |
| 29 | M&L for providing and fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over 2nd class soft wood fillets, or metal frame work and reinforced with G.I. wire mesh complete all as specified and directed.Note:- Fillets, metal frame work and G.I. wire mesh paid separately. |
| 30 | Dismantling of floor, hearth or wall tiling / Paving Blocks including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises etc complete all as specified and directed. |
| 31 | Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed. |
| 32 | M&L for sheet glass, 4mm thick, ordinary quality and glazing with oil putty in squares n exc. 0.50 Sqm each pane complete all as specified and directed. |
| 33 | M&L for sheet glass, 5.5mm thick, ordinary quality and glazing with oil putty/aluminium beading in squares exc. 0.50 Sqm each pane ground or obscured or frosted, on one side complete all as specified and directed. |
| 34 | M&L for preparation of untreated new wood/wooden surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st grade quality) over a coat of pink primer complete all as specified and directed. |
| 35 | M&L for preparing the back surfaces of chaukhats and treating them with tar or coal tar black paint complete all as specified and directed. |
| 36 | M&L for two coats of synthetic enamel paint over one coat of red oxide on new steel surfaces of any description over 10cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 37 | S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 15 mm dia bore pipe (including in short length) complete all as specified and directed. |
| 38 | S&F medium grade galvanized steel tubing (concealed) with all fittings & fixed complete to walls & ceiling or laid in floors 20 mm dia bore pipe (including in short length) complete all as specified and directed. |
| 39 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 15 mm complete all as specified and directed |
| 40 | Taking up or down steel tubing and connections,including cleaning for refixing or removal to store bore of pipe 20 mm complete all as specified and directed |
| 41 | S&F in repair fancy type, chromium plated stop valve cast copper allow screw down high pressure with crutch or butterfly handle screwed both end form iron pipe or for union and fixed of size 15mm dia complete all as specified and directed. |
| 42 | S&F in repair PVC connections pipe ,15mm dia size with PTMT nuts of length 600mm complete all as specified and directed. |
| 43 | S&F in repair for stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110 mm bore of pipe complete all as specified and directed. |
| 44 | S&F in repair 75mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 45 | S&F in repair 110mm PVC (SWR) as in drain pipes single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed. |
| 46 | S&F in repair 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed. |
| 47 | S&F 75mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 48 | S&F 110mm bore PVC (SWR) bends with rubber ring joints any radius complete all as specified and directed. |
| 49 | S&F 110mm bore PVC (SWR), junction single, (Single T) equal or unequal complete all as specified and directed. |
| 50 | S&F 110mm bore PVC (SWR) vent cowl complete all as specified and directed |
| 51 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings,dressed stonework and precast concrete articles complete all as specified and directed. |
| 52 | Dismantling of stone slabs and tiles of any description or thickness in floors, approachs, dado/Partitions laid bedded and pointed in any mortar etc complete all as specified and directed |
| 53 | Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness( below or above ground level) complete all as specified and directed. |
| 54 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 55 | Dimantling of Asbestos cement (corrugated,semi corrugated, etc.) sheets in roof coverings including ridges etc complete all as specified anddirected |
| 56 | Dismantling wall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. Please Enable Macros to View BoQ information |
| 57 | Dismantling wall and ceiling board( fiber, pulp, insulation, etc.) or insulation board/slab/ blankets, any thickness, including cover fillets complete all as specified and directed. Please Enable Macros to View BoQ information |