| 1 | Excavation in trenches not exc. 1.5 Metre wide and not exc. 1.50 Metre in depth for foundation etc. or for cable, shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and not exc. 1.50 Metre in depth and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 2 | Excavation in trenches not exc. 1.5 Metre wide and exc. 1.50 Metre but not exc. 3.0 Metre or part there of in depth for foundation etc. or for poles, cable,shafts, wells, cess pits, manholes, pier holes etc. not exc. 10 Sqm on plan and getting out as in Soft/Loose Soil, complete all as specified and as directed. |
| 3 | Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed. |
| 4 | Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified directed. |
| 5 | Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15 cm covering above the top edge of cable after laying and punning to 18 cm complete all as specified and as directed. (Note : Punned thickness shall be measured). |
| 6 | M&L Bricks common burnt clay building bricks, sub-class ‘B’ designation 75 laid dry width wise across the line of cable in trenches for protection of UG cable including dismantaling of old unservieacble bricks complete all as specified and as directed |
| 7 | M&L 100 mm bore GI tubing light grade for protection of cable including necessary joint including taking down old u/s one complete all as specified and as directed. |
| 8 | All as 7 per above item here-in-before but 40 mm dia.complete all as specified and as directed. |
| 9 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried directly in ground with earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 32 mm x 6mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanized iron pipe 40 mm bore (light grade) including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting (Inside cavity to be made in Pit for placing cover slab) made out of 8 mm dia MS bar funnel wire mesh 20 mm bore galvanized iron pipe (medium grade) for watering charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR part 1 including testing on completion all as specified and directed incl demolition to existing one complete all as specified and as directed. |
| 10 | Supply, laying & testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 volts grade cross sectional area 400 sq. mm 3½ Core including Brass Glands including dismantling old u/s cable complete all as directed by Engr-in-Charge. |
| 11 | All as per avove item no 10 item here-in-before but 95 Sqmm 3½ Core complete all as specified & directed. |
| 12 | All as per above item no 10 here-in-before but 70 Sqmm 3½ Core complete all as specified & directed. |
| 13 | All as per above item no 10 here-in-before but 50 Sqmm 3½ Core complete all as specified & directed. |
| 14 | All as per above item no 10 here-in-before but 35 Sqmm 4 Core complete all as specified & directed. |
| 15 | All as per above item no 10 here-in-before but 25 Sqmm 4 Core complete all as specified & directed. |
| 16 | All as per above item no 10 here-in-before but 16 Sqmm 4 Core complete all as specified & directed. |
| 17 | All as per above item no 10 here-in-before but 16 Sqmm 2 Core complete all as specified & directed. |
| 18 | All as per above item no 10 here-in-before but10 Sqmm 4 Core complete all as specified & directed. |
| 19 | All as per above item no 10 here-in-before but 10 Sqmm 2 Core complete all as specified & directed. |
| 20 | All as per above item no 10 here-in-before but 6 Sqmm 2 Core complete all as specified & directed. |
| 21 | M & L for heat shrink type straight through jointing kit for 1.1 KV XLPE/PVC cables of size 6 to 16 Sqmm 4 core including testing after jointing complete all as specified & directed. |
| 22 | -do- item no 21 but 25 to 50 Sqmm 3.5 Core complete all as specified & directed. |
| 23 | -do- item no 21but 70 to 90 Sqmm 3.5 Core complete all as specified & directed. |
| 24 | Material and labour for Painting by mechincal spay of LT feeder pillar Box of any size after cleaning the body surface by rubbing with emery Paper to remove rust, dust etc and applying two coat of polyurethane paint internally and externally,including indication of feeder Volt etc all as directed by Engr-in-Charge. |
| 25 | M&L for Boring/Drilling (Horizontally) manually/mechanically under existing road (Maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified and directed. |
| 26 | Dismantling existing steel or cement poles/ struts, any size carefully including necessary excavation demolition of concrete etc. and removing the old unserviceable rubbish etc complete all as specified & directed. |
| 27 | Supply and erecting steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint over one coat of red oxide primer complete all as specified and as directed by the Engr-in-Charge. Note:- Rates quoted shall be deemed to be inclusive of following works:-(a) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surface. (b) Material and labour for writing letter or figures (Block, Roman, Italic as Indian) with thick synthetic enamelled paint of apprised shade n exc 5 Cm height including numbering of pole all as directed by EIC. |
| 28 | M&L PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ Panels etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed. |
| 29 | M & L PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole/panel including necessary form work as required complete all as specified and directed |
| 30 | M & L for Hardcore of crushed stone aggregate gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 31 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 400 Amp, with breaking capacity 35 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 32 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 250 Amp, with breaking capacity 35 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 33 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 200 Amp, with breaking capacity 25 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 34 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 160 Amp, with breaking capacity 25 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 35 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 100 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 36 | Supply and fixing in repair MCCB 4 pole , 415 V Fixed type 63 Amp, with breaking capacity 16 KA including spreader link and seperator and any modification required for fixing of MCCB including taking down old unserviceable one complete all as specified and directed. |
| 37 | Supply and fixing in repair of MCB TPN 415 Volts, 63 Amps, 50 Hz, breaking capacity 10KA, C series complete all as specified and directed |
| 38 | S&F in repair 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 2.5 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 39 | S&F in repair1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 4.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 40 | S&F in repair1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 6.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 41 | S&F in repair1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 10.0 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections complete all as specified and directed. |
| 42 | Supply & fixing in repair copper cable PVC insulated stranded twin core flat or circular aluminum conductor of size 1.50 Sqmm, served with inner sheathing of PVC tape and complete all as specified and directed. Please Enable Macros to View BoQ information |
| 43 | Supply & fixing in repair copper cable PVC insulated stranded twin core flat or circular aluminum conductor of size 1.50 Sqmm, served with inner sheathing of PVC tape and complete all as specified and directed. Please Enable Macros to View BoQ information |