| 1 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and as directed. |
| 2 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth for foundation, etc or shaft wells, carpit, manhole etc and getting out complete all as specified and as directed. |
| 3 | M &L for posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 4 | M&L for Mild steel round bars 10mm dia and over, cut to length, bent to shape required, including hooking ends complete all as specified and as directed. |
| 5 | S&F galvanized. 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75mm spacing and galvanized coating of steel wire shall confirm to the requirement as laid down for medium coated wire in IS 4826 and straining and fixing to any type of standard rails staining bolts, including securing or tying at crossings with and provision of galvanized mild steel pins etc complete all as specified and as directed.(Each line wire to be measured). |
| 6 | Supply only chain link MS galvanized fencing of dia 3 to 4 mm, 75x75/50x50mm mesh size, any type complete all as specified and as directed |
| 7 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and as directed. |
| 8 | Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 9 | Material and labour for plain cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed. |
| 10 | Material and labour for brickwork with fly ash bricks, old size, having compressive strength not less than 75Kg sqcm, straight or curved on plan exc 6 M mean radius in built in cement and sand mortar 1:6 complete all as specified and as directed. |
| 11 | M&L for Brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 etc complete all as specified and as directed. |
| 12 | S&F 110mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls or laid in trenches or in floors complete all as specified and as directed. |
| 13 | M&L rendering 15mm thick on fair faces of brick work or concrete surfaces in CM (1:4) in two coats (10mm thick + 5mm thick) mixed with & including liquid water proofing compound in top layer as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and as directed. |
| 14 | Material and labour for glazed ceramic coloured / digital printed/elevation tiles of size 300 x 450 mm x 7 mm thick as in vertical surfaces of walls such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:4) complete all as specified and as directed. |
| 15 | M&L providing plain cement concrete type B1 1:2:4 with using 20mm graded stone aggregates in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed. |
| 16 | Material and labour Mild screw bolts ( Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, exc 15 but n exc 22.5cm long and 11 to 15 mm dia. of shank complete all as specified. |
| 17 | M&L Rolled Mild Steel framed work as in doors or gates of angle or other section Fe-290 GDE-165 Quality-B with gusset plates, rails, braces, etc complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (including steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete all as specified and as directed. |
| 18 | M&L preparation of new or previously untreated steel and Iron surface of any description, not otherwise described exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 19 | M&L preparation of new or previously untreated steel and Iron surface of any description, not otherwise described not exe 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed. |
| 20 | M&L preparation and applying two coats of exterior emulsion paint (weather coat) over a coat of exterior primer damp coat on a new or previously untreated plastered surfaces of facia, roof projection, chajja etc including necessary preparation of surfaces complete all as specified and as directed. |
| 21 | Returning, filling in, including spreading leveling watering and well rammming in layers not exceeding 25 cms in depth complete with all accessories complete all as specified and as directed. |
| 22 | Removing excavated material (soils) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. Please Enable Macros to View BoQ information |