| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE (I) R&D CHANDIPUR Name of Work: Repair/maint to RR masonry, culverts, area drain, communication cable ducts, cover slabs and other allied works at Tech Area, Launch complexes, Tracking stations, Site A, B & C, Kumarpur, Bhimpur, certain places from OP-4000 to OP-9000 and places along range road of ITR under AGE B/R-II Chandipur Contract No: GE(I)R&D/BLS/ 2026-27 Bidder Name : SCHEDULE 'A' (BOQ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Work / Item Item Code / Make Number or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE (including all Taxes as specified in tender Documents) In Figures To be entered by the Bidder Rs. Ps. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Excavating in trenches, n exc 1.50 m wide and n exc 1.50 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 3 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point for soils complete all as specified and directed. |
| 4 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 5 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) and removal of debris outside MD land complete all as specified and directed. |
| 6 | M&L for PCC 1:4:8 type D-2 (using 40 mm graded aggregate) as in sub-base, foundations, filling and mass concrete including necessary formwork complete all as specified and as directed. |
| 7 | M&L for cement concrete 1:3:6 type C-1 (using 20 mm graded stone aggregate) as in surface channels, drains, haunching, coping etc including necessary formwork complete all as specified and directed. |
| 8 | M&L for plain cement concrete type B-1 1:2:4 (using 20 mm graded stone aggregate) as in sub base, benching, coping, etc including necessary formwork complete all as specified and directed. |
| 9 | Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided complete all as specified and directed. |
| 10 | M&L for RCC (nominal mix) 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, basement slabs, under-reamed piles, mass concrete and similar works complete all as specified and as directed. |
| 11 | M&L for RCC (nominal mix) 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and as directed. |
| 12 | M&L for RCC (nominal mix) 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels etc complete all as specified and as directed. |
| 13 | M&L for RCC (nominal mix) 1:1.5:3 type B-1 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like etc complete all as specified and as directed. |
| 14 | M&L precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregrate) set in cement mortar 1:4 as in cover slabs of drain/cable ducts etc including necessary formwork complete all as specified and directed. |
| 15 | M&L for mild steel TMT bars 10mm dia & over, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire and quality conforming to Fe-410-W (Gde E-250) quality-A or Fe 290 (Gde E-165) complete all as specified and directed. |
| 16 | M&L for mild steel TMT bars 5mm dia & over up to including 10mm dia in stirrups, spacers and binders, cut ot length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with wire and quality conforming to Fe-410-W (Gde E-250) quality-A or Fe 290 (Gde E-165) complete all as specified and directed. |
| 17 | M&L for formwork to sides of foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work for rough finished surface of concrete complete all as specified and directed. |
| 18 | M&L for formwork to sides of pillars, posts, struts, piers, columns, and stanchions in square, rectangular etc for rough finished surface of concrete complete all as specified and directed. |
| 19 | M&L for formwork to sides and soffits of roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs etc for rough finished surface of concrete complete all as specified and directed. |
| 20 | M&L for formwork to sides and soffits of of suspended slabs such as roof slabs, floor slabs, landings and similar work (Horizontal or sloping) including supports, overhangs etc for rough finished surface of concrete complete all as specified and directed. |
| 21 | Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar incl aii quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 22 | M&L for fly ash brickwork with modular flyash bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed. |
| 23 | M&L walling of random rubble, uncoarsed, well bonded bedded solidly hearted built in CM 1:4 etc incl complete all as specified and directed. |
| 24 | All as per item No 22 above but except stone. |
| 25 | M&L for boulder pitching, laid dry, hand packed tightly complete all as specified and directed. |
| 26 | Taking down cement plaster any description and the like on brick or stone walls, etc including raking out joints,hacking for key, scrubbing down with water etc and removal of debries outside MD land complete all as specified and directed. |
| 27 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even and smooth without using extra cement (including as in patches also) complete all as specified and directed. |
| 28 | M&L for keyed pointing to stone masonary, boulder pitching uncoursed or brought upto course in CM 1:4 complete all as specified and directed. |
| 29 | M&L for RCC pipes 600mm dia, Class NP2, laid and jointed complete with collars including demolition of existing RCC pipes complete all as specified and directed. |
| 30 | M&L for RCC pipes 450mm dia, Class NP2, laid and jointed complete with collars including demolition of existing RCC pipes complete all as specified and directed. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |