| 1 | Excavation in trenches not exc. 1.5 m width and not exc. 1.5 m in depth and getting out in hard / dense soil complete all as specified and as directed. |
| 2 | M&L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 3 | M&L for Reinforced Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in foundation, including rafts, footings, foundation beams, plinth beams, bases of coloums etc basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. |
| 4 | M&L for Reinforced Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in colums, pillar, piers, posts and struts etc. complete all as specified and as directed. |
| 5 | M&L for Reinforced Cement Concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) as in slab supported on walls, beams and columns in floors, roof, landing, balconies, canopies, deck slab and in shelves and the like complete all as specified and as directed. |
| 6 | Use and waste of formwork to sides of concrete foundation, footing, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 7 | Use and waste of Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed. |
| 8 | Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. |
| 9 | M&L for Providing Precast Reinforced Cement Concrete in lintels including use and waste of necessary fomwork complete all as specified and as directed. |
| 10 | M&L for MS TMT bars 10 mm dia and over as in reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed. |
| 11 | All as per item No.10 above but 6 to 8 mm dia bars as in stirrups, binders complete all as specified and as directed. |
| 12 | M&L for Precast Cement Concrete solid block masonry exc. 10 cm in width with minimum compressive strength of 50kg/sqcm using PCC (1:3:6) type C1 (using 20mm graded aggregate) set in CM (1:6) complete all as specified and as directed. |
| 13 | M&L for 15 mm thick rendering in cement mortar on fair faces of brick work or concrete surfaces, applied in two layers ie. Ist layer of 10 mm thick rendering in cement mortar (1:6) and 2nd ( top) layer of 5 mm thick rendering in cement mortar (1:4) and top layer mixed with water proofing compound & finished even and smooth without using extra cement complete all as specified and directed.Note: Water proofing compound shall be measured and paid seperatly under relevant item as supply only. |
| 14 | Supply only liquid water proofing compound complete all as specified and as directed. |
| 15 | M&L for 10mm thick in CM (1:6) rendering on brick or concrete surfaces finished even and smooth (without using extra cement), complete all as specified and as directed. |
| 16 | M&L for Preparation of newly plastered surface of wall and applying two coats of cement based paint over a coat of primer complete all as specified and as directed. |
| 17 | M&L for Preparing Newly plastered surfaces of walls and applying Two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed. |
| 18 | M&L for 100mm thick Damp Proof Course (1:2:4) type B-0 (using 12.5mm aggregates) to horizontal or vertical surfaces including necessary formwork complete all as specified and as directed. |
| 19 | M&L for hard core of gauge n.exc. 63 mm deposited , spread and levelled in layers n. exc. 15 cm thick watered and rammed to a true surface complete all as specified and as directed. |
| 20 | M&L for 100mm thick cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in Sub base of flooring complete all as specified and as directed. |
| 21 | M&L for 40mm thick cement concrete (1:2:4) type B1 (using 20 mm graded stone aggregate) flooring complete all as specified and as directed. |
| 22 | M&L for Non-skid Ceramic coloured tiles (300mmx300mm) x 7-8 mm thick (square / rectangular), area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors set & jointed in neat cement slurry and pointed in cloured cement to match laid over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 23 | M&L for Glazed coloured Ceramic tiles in verticle surface 450mm x 300mm x 6-7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement to match including Screed bed or bedding layer of mortar 10 mm thick CM (1:4) for laying floor/wall finishes complete all as specified and as directed. |
| 24 | M&L for Non Asbestos Cement plain building board 6mm thick ceiling fixed with size of grid (605X605mm), anodized aluminium snap grid (main/cross tee section) shall be supported at ends all along the wall with aluminium angle of size (40mmx25mmx2mm) and the main and cross tees shall be joined at junction/crossings with anodized aluminium angle bracket of size (15mmx15mmx1.5mm) frame work for false ceiling with hangers 6mm dia. G.I. not exceeding 1.2m length placed at spacing 1.5m x 1.5m complete all as specified and as directed. |
| 25 | M&L for chequered colour cement concrete tiles (30cmx30cmx 25mm) thick with grey cement and pigment set jointed and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm (1:4) complete all as specified and as directed. |
| 26 | M&L for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed. |
| 27 | M&L for Mild steel plates (Plain or chequrred , channels, square cut or notched ordinary and with reivited bolted or welded attachment Fe-410-W (Gde E-250 quality) complete all as specified and as directed. |
| 28 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. |
| 29 | M&L for preparation of steel surface of any description 10 cm in width or grith and applying two coats of synthetic enamel paint over one coat of primer complete all as specified and as directed. |
| 30 | M&L for Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick Grade AZ 150 GSM of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws, as per manufacturer instructions complete all as specified and as directed. |
| 31 | M&L for Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick Grade AZ 150 GSM of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall,valley gutter fixed with self tapping screws, as per manufacturer instructions complete all as specified and as directed. |
| 32 | M&L for 75mm thick PCC (1:3:6) type C2 (40mm garade aggregate) as in plinth protection finish even and smooth without using extra cement complete all as specified and as directed. |
| 33 | M&L for Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size (45mmx70mm) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately) complete all as specified and as directed.Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. |
| 34 | S&F for Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, complete all as specified and as directed.Note: stainless steel butt hinges and necessary S.S screws shall be paid separately. |
| 35 | S&F for mild steel butt hinges steel hinges medium weight 100 mm long complete all as specified and as directed. |
| 36 | S&F for aluminium alloy anodised handle, febricated type 150mm long complete all as specified and as directed. |
| 37 | S&F for aluminium anodised, 150mm long barrel tower bolts of extruded section complete all as specified and as directed. |
| 38 | S&F for 200 mm aluminium alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sjeet, cast or extruded sections or cast aluminium alloy complete all as specified and as directed. |
| 39 | S&F for Powder coated anodised aluminium frame for doors, windows, ventilators with or more rebates including joining cleat for fixing etc. complete all as specified and as directed. |
| 40 | S&F for Anodised aluminium window/ ventilator shutters with 4 mm thick tinted/ frosted glasss of sliding type sash, aluminium section weighing 0.55 kg/m including nessary joining cleats, glazing clips, rubber paking, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 nos), hinges type B-21 100mm long (2 Nos) suiatble handle (1 Nos) complete all as specified and as directed. |
| 41 | S&F vitreous china wash down water closet pan (EWC) white with seat and cover (excld flushing cistern & Pipe) including connection to trap and flushing pipe complete all as specified and as directed. |
| 42 | S&F for PVC low level flushing cistern of 10 ltr capacity fixed including syphonic action type,ball valve, float and handle including brackets, PVC connections 15mm size etc complete all as specified and as directed. |
| 43 | S&F for PVC connections 15mm size with PTMT nuts and washers for 600mm long pipe complete all as specified and as directed. |
| 44 | S&F for Bib taps of 15mm dia chromium plated cast copper alloy of fancy type screwed down for iron pipe complete all as specified and as directed. |
| 45 | S&F for 2 in 1 Bib taps of 15mm dia chromium plated cast copper alloy of fancy type screwed down for iron pipe complete all as specified and as directed. |
| 46 | S&F for Health faucet (ABS Body) mild steel chromium plated suaitable for 15mm dia pipe with 1.25 mtr long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and as directed. |
| 47 | M&L for granite (of any type) 20mm thick work (table rubbed and polish to mirror finish), in steps, jambs, pillers, windows sills, cooking platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick cement mortar (1:4) complete all as specified and as directed. |
| 48 | S&F for wash hand basin vitreous china white flat (counter top) of size (450mm X 300mm) with brackets,including cutting for and pinning in ends of brackets or erecting stand including CP pillar tap of 15 mm dia cast copper alloy fancy type screwed down high pressure, with long screwed shank and waste coupling with waste pipe LDPE PVC pipe 32mm dia complete all as specified and as directed. |
| 49 | S&F for Stop valves 15mm dia cast copper alloy fancy type , chromium plated, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed. |
| 50 | S&F for looking mirrror of any size of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fitted in aluminium frame with chromium plated brass screws and cup washers complete all as specified and as directed. |
| 51 | S&F for Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms) complete all as specified and as directed. |
| 52 | M&L for Cast iron floor trap,(100 mm) with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and as directed. |
| 53 | S&F for Soap dish vitreous china white, approximate size 160 x 160 x 90mm, any type, fixed to plugs with chromium plated brass screws complete all as specified and as directed. |
| 54 | M&L for 15mm nominal bore dia tubes, medium grade, galvanished with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed. |
| 55 | M&L for 20mm nominal bore dia tubes, medium grade, galvanished with all fittings and fixed complete to walls and ceilings or laid in floor complete all as specified and as directed. |
| 56 | S&F for PVC (SWR) pipes 110 mm dia, single socketed, in any length with rubber rings joints, laid in trenches or in floors complete all as specified and as directed. |
| 57 | S&F for 110 mm PVC (SWR) bends any radius complete all as specified and as directed. |
| 58 | S&F for PVC (SWR) vent cowl 110mm dia all as specified and as directed. |
| 59 | S&F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed in down stream complete all as specified and as directed. |
| 60 | M&L for RCC NP3 150mm diameter pipes as in sewage lines laid on 150mm thick PCC bed (1:4:8) with excavation in any type of soil, including manholes/drop manhole of standard size made of Brick masonry/ RCC/ Precast RCC with SFRC ventilating cover and frame includes all items and activities to excute and make sewer line functional complete all as specified and as directed. |
| 61 | M&L for RCC Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc. for 5 users complete all as specified and as directed. |
| 62 | M&L for RCC Hume Pipe septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC (1:4:8) below foundation, Vent shaft, connection etc., for 10 users complete for functional complete all as specified and as directed. |
| 63 | M&L for Soakage wells for upto 25 users including excavation, in any type of soil, foundation in PCC (1:3:6), walls of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber made of Brick masonry in CM, RCC cover slab in M25/ SFRC cover, inter connecting pipes of RCC/DWC complete filled with brick bats of size 1.2 m dia and 1.50 m effective depth all as shown in CE A&N Zone TD Drawing CE / TD / 2022 / 17 SHEET 1/1 complete all as specified and as directed. |
| 64 | Point wiring using approved colour coding as per IS, with stranded copper conductor 1.5 sqmm (nominal area), single core, flame retardant low smoke(FRLS), PVC insulated and unsheathed cable 1100 volts grade, ISI 694 marked TEC and FIA approved in and including PVC casing and caping/PVC conduit and its fittings ISI marked, with metal flush boxes suitable for modular/normal switch/sockets etc with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer internally, incl covered with suitable module cover plate with frame including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper conductor 1.5 sqmm (nominal are) single core cable as earth continuity conductor to common earth and connected to earth dolly One light/fan point controlled by one switch complete all as specified and as directed. |
| 65 | S&F for switch piano, flush type single pole one way 5/6 amps complete all as specified and as directed. |
| 66 | S&F for ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and as directed. |
| 67 | S&F for MCB SPN 32 Amps 240 Volts 10 KA complete all as specified and as directed. |
| 68 | S&F for MCB SP 6-32 Amps 240 Volts 10 KA complete all as specified and as directed. |
| 69 | S&F for MCB DB's 4 Way SPN, 240 volts for mounting MCBs/RCBO's ELCB's etc. as per IS specification of factory made fabricated out of CRCA sheet 1.2 mm thick powder coated fitted with DIN Channel neutral link and 200 Amps rated bus bar.The DB's shall double door vertical type, Inner door fixed on spring loaded hinges with locking arrangement & outer door openable hinged with locking arrangement having IP-43 protection complete all as specified and as directed. |
| 70 | Sub main wiring with approved colour coding as per IS with 2 runs of single core PVC insulated cable FRLS with Multi Strand copper conductor of size 4Sq. mm and drawing into PVC conduit including 1 run of PVC insulated 4 sqmm stranded copper conductor as earth wire complete all as specified and as directed.Note : 3 runs of copper cable and one run of PVC conduit shall mearured as one unit. |
| 71 | S&F for Exhaust fan AC single phase 230/240 volts steel body 300mm sweep with blades and frame and louvers complete all as specified and as directed. |
| 72 | S&F LED lights fittings 1x 18 watt, 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. |
| 73 | Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 Sqmm 2 core. from walls, poles, trenches complete all as specified and as directed. |
| 74 | Excavation in trenches in soft/loose of soil n.exc. 1.5 mtr in width and n.exc. 1.5 mtr in depth and getting out all as required for laying of cables complete all as specified and as directed. |
| 75 | Returning filling, in including spreading ,leveling, watering and well ramming in layers n.exc. 25 cm each complete all as specified and as directed. |
| 76 | Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. |
| 77 | Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked IS 14390 part-II of outer dia 40mm and inner dia 32mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accesoories like coupler, 'O' ring etc for protection of cable complete all as specified and as directed. |
| 78 | Earthing complete with galvanised steel earth plate electrode of size (60cmX60cmX 6mm) buried directly in ground (earth pit not less than 2.25 metres deep below the normal ground level) with top edge of the plate not less than 1.5m below normal GL connected to GI earth wire 4 mm dia by means of GI bolts, nuts, check nuts and washers and earth strip protected by 25 mm dia GI pipe medium grade and connected to main distribution board/earthing test point all as shown on electrical plate No.3 of SSR Part I and all as specified including testing on completion.Notes: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete (1:3:6) mix, Type C1 pit, 40mm thick RCC (1:2:4) mix, type B1 cover reinforced with 8mm dia TMT bars @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh, protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II and also refer Plate No-03. Earth strip and protection pipe beyond 7.5m shall be measured and paid separately complete all as specified and as directed. Note :- Earthing shall be redone if desied earth result not found during testing of the same at site. |
| 79 | Supply and laying tubes, medium grade galvanised with all fittings of size 25mm dia laid in trenches/floor/wall complete all as specified and as directed. |
| 80 | S&F for gun metal gate valves 25mm dia, with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and as directed. |
| 81 | M&L for disconnecting the existing LT UG cable from panel, dismantling of LT UG cable from retaining wall by uncalmpinng,passing through DWC/GI pipe and reconnecting,testing complete all as specified and as directed.Note: Earth work, DWC/GI pipe measured and paid separately. Damaged cable to be replaced with new and paid separately. |
| 82 | Supply and Laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and as directed. |
| 83 | S&F in 80 mm dia tubes light grade galvanised with all fitting, laid in trenches complete all as specified and as directed. |
| 84 | S&F in 40 mm dia tubes light grade galvanised with all fitting, laid in trenches complete all as specified and as directed. |
| 85 | Excavation post holes or similar works, each n.exc. 0.5 Cum, getting out hard/dense soill. Returning,filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc. 25 cm and watering and removing surplus soil to a distance not exceeding 50m and making good surfaces complete all as specified and directed. |
| 86 | M&L for Plain Cement Concrete type B-1, (1:2:4) (using 20 mm graded aggregate) in filling of foundations, post holes, columns, walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts complete all as specified and as directed. |
| 87 | S&F for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. Please Enable Macros to View BoQ information |