| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work: Maintenance of LT Cables and panel at 12 Dogra and other locations under GE (Utilities) Udhampur Contract No: GE/U-57/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for foundations of poles/stays etc .not exc 10 Sqm area on plan and getting out in soft/loose soil complete all as specified and directed by Engineer-in-charge. |
| 3 | Description all as per Ser item No 1.00 here-in-before, but exc. 1.50 metre depth and not exc. 3.00 metre deep. |
| 4 | Returning, filling in excavated soil in trenches including spreading, leveling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed by Engineer-in-charge. |
| 5 | Removing of excavted soil to a distance n. exc. 50 mtr and deposited where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-charge. |
| 6 | Taking up old serviceable/unserviceable UG cable from trench/pcc/interlocking/tiles including disconnection disconection from electrical equipment for replacement , repair and re-laying or re-routing of size including make good the distrubed surface as per existing, complete all as specified and directed by Engineer-in-charge:- (Earth work shall be measured and paid separately under appropriate items of Sch-'A') |
| 7 | 16 Sqmm 4 Core to 35 Sqmm 3.5 Core |
| 8 | 50 Sqmm 3.5 Core to 95 Sqmm 3.5 Core |
| 9 | 120 Sqmm 3.5 Core to 185 Sqmm 3.5 Core |
| 10 | 240 Sqmm 3.5 Core to 400 Sqmm 3.5 Core |
| 11 | Supply & lay test and commissiong of LT Cable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable ( heavy duty) with aluminium conductor , 1100 volts earthed grade cross sectional area as illustrated below, complete all as specified and directed by Engineer-in-charge. Note : Excavation, earthwork, Sand Cushioning, Cable covers, Pipe for cable protection to be measured and paid for separately). |
| 12 | 16 Sqmm 4 core |
| 13 | 25 sqmm 3.5 core |
| 14 | 35 sqmm 3.5core |
| 15 | 50 Sqmm 3.5 core |
| 16 | 70 Sqmm 3.5 core |
| 17 | 95 sqmm 3.5 core |
| 18 | 120 sqmm 3.5 core |
| 19 | 150 sqmm 3.5 core |
| 20 | 185 sqmm 3.5 core |
| 21 | 240 sqmm 3.5 core |
| 22 | Taking down existing U/S Lt Panel of any type and size and any condition complete including disconnection of electric connection complete from site/wall and making good the distrubed surface complete all as specified and directed by the Engineer-in-Charge. |
| 23 | Supply, install commissioning and testing of cubical out door feeder LT panel board of suitable size platform mounted, factory made totally enclosed dust and vermin proof (protection class IP-54, CPRI Approved) double shutter front and back opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work and 3.15 mm thick CRCA sheet duly painted with powder coated paint to all steel surfaces over outside and inside complete. The panel board shall be suitable for 415 volt, 50 Hz, 3 phase, 4 wire system with epoxy type copper bus bar of appropriate size and internal control wiring shall be of insulated multi stranded copper conductor cables. Note- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv) Cables shall be terminated using gun metal /SS glands. (v) including suitable thimbles/lugs, nut bolts ,washers fitted the cables |
| 24 | (vi) cable glands for incoming and out going suitable cables is including rate quated by vendover (vii) including suitable thimbles/lugs, nut bolts ,washers fitted the cables, Panel to be fixed at 450mm above Natural Ground Level on Brick Masonry Platform including Cement Concrete 1:2:4 (20mm graded stone aggregates) 100mm thick around the Area upto 1.50 Metre in all directions from the Panel all as ordered including Provision of Cattle Fencing with Open-able Gate (1.20 Metre to 1.50 Metre in Height) around the Area upto 1.50 Metre, complete all as specified and directed by Engineer-in-charge. (PCC platform of suitable size in cement concrete tybe-B1 using 20mm graded stone aggregate for mounting the feeder pillar box shall deemed to be included in the quoted rate ) and to accommodate the following incoming and outgoing controls and suitable size:- Note :- 02 Nos padlock has to be fixed in the panel. The rates of the padlock is included in the quoted rates of panels. :- |
| 25 | Incoming(a) MCCB 320 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, (b) MCCB 250 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, ( c) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,(d) MCCB 100 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, |
| 26 | Outgoing (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 500 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iv) Outgoing MCCBs shall be fed with solid busbar connectors and (v) Cables shall be terminated using gun metal /SS glands.(vi) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(vii) cable glands for incoming and out going suitable cables is including rate quated by vendover |
| 27 | Description all as per Ser Item No 8.00 here-in-before, but following capacity for Incoming(a) MCCB 200 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,Outgoing (b) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level (iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands.(iv) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover |
| 28 | Description all as per Ser Item No 8.00 here-in-before, but following capacity for Incoming(a) MCCB 160 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No,Outgoing (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work. (ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands.(iV) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming and out going suitable cables is including rate quated by vendover |
| 29 | Description all as per Ser Item No 8.00 here-in-before, but following capacity for Incoming(a) MCCB 100 A 4 pole, with thermal adjustable and fixed magnetic setting with extended 50Hz ,415 V with rupturing capacity 35 KA-01 No, Outgoing (a) Bus bar electrolytic grade copper and supported on Non-hygroscopic, non carbonising, corrosion resistance SMC insulators 300 Amp,4 pole, not less than 75 cm long mounted on insulators 01 setNote- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.(ii) Panels shall be placed above 0.6 mtr from ground level(iii) Outgoing MCCBs shall be fed with solid busbar connectors and (iii) Cables shall be terminated using gun metal /SS glands.(iv) including suitable thimbles/lugs, nut bolts ,washers fitted the cables(v) cable glands for incoming LT cable 95 sqmm -01 Nos and out going cables 70 sqmm -02 Nos and 50 sqmm - 01 Nos and 25 sqmm -04 Nos is including rate quated by vendover |
| 30 | Earthing complete with galvanised steel earth plate electrode size 60 cm x 60 cm, 6.3 mm thick burried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, connected to galvanised iron or steel, earth strip 32 x 6 mm size by means of nuts, bolts check nuts and washers made of galvanised iron or steel, earth wire protected by galvanised iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC 1:3:6 type C-1(using 20 mm graded stone aggregate), pre-cast RCC cover slab 30 cm x 30 cm x 10 cm with one lifting handle made of 8 mm dia MS bar funnel wire mesh, 20 mm bore galvanised iron or steel pipe medium grade for watering charcoal or coke and salt in alternate layers, necessary excavation and earth work in any type of soil complete all as shown in electrical Plate No 5 of MES Schedule Part- I and testing on completion . (Concrete pit shall be 20 cm to 30 cm away from main pit), complete all as specified and directed by Engineer-in-Charge. |
| 31 | Taking down/Dismantling of old unserviceable/corroded ACSR Conductor of any size from existing over head lines completed and supply, lay and fix aerial bunched cable 1.1KV grade stranded and compact aluminium phase conductor of size 4x25sqmm + 1x16 sqmm (bare messenger) with Aluminium alloy and Junction box The phase conductor shall be insulated with XLPE (Sioplas) compound Aluminium as per IS-14225-1995 including all fittings such as anchor clamp, suspension clamp, line connector, service clamp, Including End joints insulator piercing connectors, for taps from bare line etc. complete all as specified and directed by Engineer-in-Charge. Note :- Retrived conductor scrap ( Lumpsum ) shall be deposited AGE E/M storeyard with own arrangement by the contractor. |
| 32 | M&L for Road cutting/Boring for laying of cable/pipe and making good the disturbed/excavated surface as per existing road including refilling the excavated material, compacting, WBM and black top carpeting with bitumen & aggregate following the stone/sand on top complete all as specified and directed by Engineer-in-Charge. |
| 33 | S&F straight through joint kit, heat shrinkable type suitable for 70 to 95 sqmm LT UG Cable complete all as specified and as directed by Engineer-in-Charge. |
| 34 | S&F straight through joint kit, heat shrinkable type suitable for 120 to 185 sqmm LT UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 35 | S&F straight through joint kit, heat shrinkable type suitable for 240 to 400 sqmm LT UG Cable complete all as specified and directed by Engineer-in-Charge. |
| 36 | M&L for aluminium thimble cable (Lugs) suitable for Cable of size 25 sqmm to 70 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 37 | 95 Sqmm to 120 Sqmm |
| 38 | 150 Sqmm to 240 Sqmm |
| 39 | 300 Sqmm to 400 Sqmm |
| 40 | Dismantling of old UNSVdamage/rusted PCC pole/steel tubular poles of any size necessary disconnecting cables/over head condcutor and removing unserviceable pole from site complete all as specified, and make good the distrubed surface complete all as specified and directed by Engineer-in- Charge. |
| 41 | S&F of Steel tubular swaged poles erected to truly vertical or planted as strut complete with 6 mm thick mild steel base plate, welded to Pole, B-118 finial taper cap, bolts, nuts and screws, poles made out of ERW MS tubing conforming to IS-2713 Part-II type 410-SP-31 (9m long) including drilling of holes of required size for fixing of cross arms, painting the exposed surfaces of pole with two coats of aluminum paint over a coat of red oxide zinc chrome primer and with two coats of black bituminous paint on the and portion embedded in concrete, making five black and white bands at lower portion of pole above ground level/coping each 300 mm wide alternately and marking pole number. with black paint at suitable height complete all as specified and directed by Engineer-in-Charge. Note:- The earthwork, PCC foundation, steel clamps, MS Cross arms & bracing of angle iron etc will be measured and paid separately under relevant items of Sch ‘A’. |
| 42 | M&L Plain cement concrete 1:3:6 type C-2 as in foundations filling and mass concrete using 40 mm graded stone aggregate complete all as specified and directed by Engineer-in-Charge. |
| 43 | M&L Plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate for coping of poles complete all as specified and directed by Engineer-in-Charge. |
| 44 | M & L for painting to steel tubular swaged pole of Overhead lines (9 Mtr long) complete with and including comprising the following works :- (a) Scraping out wornout old paint and making the surface smooth. (b) Painting the pole and all MS work mounted on pole with two coats of synthetic enameled paint (Aluminium shade) as directed by Engg.-in-charge. (c) Forming five nos coloured bands at lower portion of pole each 300 mm wide alternatively with white and black colour (or any colour as approved by Engineer-in-charge) synthetic enameled paint and marking pole no. with black and white paint complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply and fixing PVC insulation tape red,yellow, blue colour 25 mm 25 mtr length tape Roll Lall complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F double walled corrugated (DWC) pipe of size 120 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and as directed by Engineer-in-Charge. |
| 47 | S&F double walled corrugated (DWC) pipe of size 77 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and as directed by Engineer-in-Charge. |
| 48 | S&F double walled corrugated (DWC) pipe of size 50 mm including snap fit coupler conforming to IS14930 (Pt-II)/IS16205 Pt-II for protection of LT cable in under ground complete all as specified and as directed by Engineer-in-Charge. |
| 49 | 1100 Volts grade heavy duty cable PVC (in replacement ) insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 10 Sqmm cable flat or round complete all as specified and as directed by Engineer-in-Charge. |
| 50 | 1100 Volts grade heavy duty cable PVC (in replacement ) insulated stranded aluminium conductor served with inner sheathing of PVC tape and over all PVC sheathed in service conncetions one twin core 06 Sqmm cable flat or round complete all as specified and as directed by Engineer-Charge. |
| 51 | Material and labour in replacement of PVC insulated multi stranded copper conductor PVC cable sheathed 1.5 sqmm 2 core and making connections of street light fittings and bollards lights complete all as specified and as directed by Engineer-in-Charge. |
| 52 | Supply and fixing non transparent looping SMC kiosks pole box 3 phase of size 310×210×120 mm made out of engineering plastic one piece moulding siemens gray colour with hold fast including 4 Nos aluminium strips 60 amp of requird size fixed on unbrakable insulator and one no single pole MCB 1 to 3 amp 'C' curve including taking out of old unserviceable one, complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply, install, 150 amp copper Bus bar with enclouser wall mounted/pole mounted size 300 mmX250 mm ,suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 2 mm CRCA MS sheet for cable entry and locking arrangement complete all as specified and directed by Engineer-in-Charge with following :- |
| 54 | Dismantling of cross arms fixed on steel tubular poles carefully and removing from site complete all as specified and directed by Engineer-in-Charge. |
| 55 | M & L for Cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply and fixing in replacement GI bracket 40 mm dia 1.5 Mtr long light grade made to shape including taking down old and u/s existing fitting complete all as specified and as directed by Engineer-in-Charge. |
| 57 | Dismantling of existing street light fitting of any size/type complete with bracket including necessary electrical connection complete all as specified and directed by Engineer-in-Charge. |
| 58 | Refixing of Energy saving & environment friendly LED street light fittings made out of pressure die cast anodized alluminium housing equal or less than 60 watt including fixing of 1.5 RM length GI bracket of suitable size for fitting with necessary clamps nut and bolts including taking down old unserviceable street light fitting, complete all as specified and directed by Engineer-in-Charge. |
| 59 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 80 mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 50 mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply and fixing or laying galvanized steel tubing medium grade (ISI) marked for protection of under ground cable of size 40 mm bore, complete all as specified and directed by Engineer-in-Charge. |
| 62 | M&L for Premix ready mix road repair patching compound for instant repair manufactured with a blend bitumen, aggregates and high grade polymer to ensure immediate bonding with existing surface available in bag of 25 Kg, complete all as specified and directed by Engineer-in-Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |