| 1 | SITC Of Round flood light, 24W, 1780 lumens pm 10 5 2, 30 deg beam (plus/minus 10)% 3000K ±150K Supply of exterior-rated architectural floor/wall/Pole mounted, IP66, round flood light complete with antiglare snoot. The power consumption should be not more than 24 watts, minimum system lumen delivered shall be 1780 lumens (plus/minus 10)% 30 deg beam angle (plus/minus 10)% CCT-3000K ±150K LED from CREE/NICHIA/LUMILED/OSRAM. The housing material should be die-cast aluminum with Electrostatically applied polyester powder coating. The luminaire is to be installed with anti-aging and anti-UV high optical efficiency PMMA lenses and a clear tempered glass cover. Bracket shall have a locking mechanism to fix and secure the required tilting angle, plus/minus 90 deg It should have CRI>80, and SDCM≤4. The driver should be integrated AC with PF > 0.1 & and THD-20%, Leader cables, jumper cables, and IP68 connectors are included, minimum IK06. The operating temperature should be of - 40 deg * C to 50 deg * C range and the storage temperature shall be - 40 deg * C to 70 deg * C the weight of luminaire shall be min 1.8kg. The lifetime of the luminaire (L70 @ Ta-35deg C) should be at least 50,000 burning hours. Luminaire should have corrosion resistance with self-declaration of ASTM B117 for 500 hours of salt spray test Photometric data shall be passed on test results from an independent testing lab. All mounting accessories shall be stainless steel (Minimum-316) for all lighting fixtures. All hardwired connections to LED fixture shall be reverse-polarity protected and shall provide high-voltage protection in the event that connections are reversed or shorted during installation. The luminaire should be BIS-certified The luminaire manufacturer shall provide optical performance, polar diagram and photometric data in various formats including IES files in accordance with IES 79-08. This includes all the required hardware for the successful operation of the luminaire. All the technical parameters of the luminaire need approval from the lighting consultant. Including casing made of SS with five year O&M Complete in all Respect. |
| 2 | SITC of 1000mm long RGBW (W=4000°K) LED Rigid Linear Uplighter with System wattage of maximum 15-watt, min lumen output of 700lm, 20x30 degree beam angle, complete with integrated power supply, suitable IP66connectors, luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 1000X25X35mm with bracketand minimum weight of 0.85kg. The Luminaire shall have tilting adjustability +15° to-90°. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35deg C. The luminaire should be IP66 & IK-06. The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C. The product shall comply to and shall have test repots for IEC 60598-2-5:2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC 55015:2019+A11, EN 61547:2009, EN 61000-3-2:2019, EN 61000-3-3:2013, IS 10322 (Part 5/Sec5):2013, LM80. Manufacturere ealf declaration shall he unloaded along with the technical hid. Including casing made of SS with five year O&M Complete in all Respect. |
| 3 | SITC of 1000mm long RGBW (W=4000°K) LED Rigid Linear Uplighter with System wattage of maximum 120-watt, min lumen output of 3000lm, 7.5X27degree beam angle, complete with integrated power supply, suitable IP66 connectors, luminaire controls via DMX512 with Auto addressing for easy configuration. The connectivity should be of a daisy chain topology, allowing easy installation to form long run lengths. The same shall include Installation clamps, 5core/cat-6 or suitable control cables UV and weatherproof, other required accessories & hardware. The luminaire shall be extruded Aluminium with Electrostatically applied polyester powder coating, silicon gasket and clear tempered glass, minimum dimension of 1000X158X88mm with bracket and minimum weight of 8.5kg. The Luminaire shall have tilting adjustability +15° to - 90°. The LED luminaire shall have SDCM<4 for white, the life of Luminaire shall be 50000hrs L70B50 at 35degC. The luminaire should be IP66 & IK-06. The operating temperature of Luminaire shall be -40°C to 50°C and storage shall be -40°C to 70°C.The LED should be discreetand not four in one & DMX Decoder should be interigated. The product shall comply to and shall have test repots for IEC 60598-2-.2015, IEC 60598-1:2014 + A1, IEC TR 62778:2014 (for LED chips), EN IEC55015:2019+411 EN 61547:2009 EN 61000.3.2-2019 0033:2013 Including casing made of SS with five year O&M Complete in all Respect. |
| 4 | SITC of surface mounted, exterior-rated LED linearstrip light with 55W/5m 400 Im/m luminaire with all the necessary accesories as below that is designed for grazing architectural lighting applications waterproof and anti- dust LED strips. It shall be sealed with Glue-injected with polyurethane (PU). SDCM<5 and RGB. Robust Design & IP68 rating for outdoor use. Luminaire has input voltage 24VDC, Operating temperature -40°C to 50°C, IP68 & IK06 protection, Lumen maintenance of 30,000 hrs @ L50 at 35°C. Standards: EN60598, EN62471, EN62493+IEC62778, CE-EMC. Including casing made of SS with five year O&M Complete in all Respect. |
| 5 | SITC of controller to author, configure, and control dynamic LED light shows for DMX lighting networks. The controller with two universe of DMX ports control up to 340 light addresses, Works as a stand-alone or computer-driven controller, Secure Digital (SD) card drive for flexible show storage, USB 2.0 interface for downloading shows and configuring from attached PC or Mac, Simple installation and wiring is required, Flexible, adaptable mounting options are expected, Should be provided with light show authoring software, Direct line voltage power supports 100-240 VAC, Six configurable effects -Using light show authoring software to select from six effects, adjust effect settings, such as color, speed, and brightness etc as reqd. The DMX controller and software should be from the same manufacturer as the proposed luminaire. Including casing made of SS with five year O&M Complete in all Respect. |
| 6 | Supply of compact DMX signal splitter cum amplifier that takes the incoming DMX512/RDM signal and amplify the signal and supporting bi-directional communications for discovery, addressing and DMX control of light fixtures. This unit takes the incoming DMX/RDM signal and splits the signal into six separate output channels allowing for expanding the number of devices controlled from 32 to 6 X 32. The output terminals are electronically isolated from the input & RDM-through port and share a common ground reference. All six output ports have an independent output driver to boost the DMX/RDM signal. Operating temperature shall be -10° to 35°C. The maximum power consumption shall be less than 4.5W and input voltage shall be 12-24V 4 28000 112000 DC Including casing made of SS with five year O&M Complete in all Respect. |
| 7 | Programming, testing and conmmissing of RGB lights with schene ereation (5-7Nos) Testing, commission, and program lighting fixtures aecording to the consultan/architeer's requirements and standards, follow these steps. 1. Review Requatements. -Obtain detailed requirements and standards. Understand the desired lighting scenes and themesfor each area. 2. Planning - Develop a plan outlining the sequence of testing and commissioning -Identify all DMX-controlled lighting fixtures and their locations -Plan the different lighting seenes and themes that need to be designed. 3. Installation Verification:-Ensure all lighting fixtures are installed correctly and securely. -Check the wiring and connections for DMX controllers and fixtures.4. Programming DMX Controllers -Set up DMX controflers and configure them according to the lighting design plan. Program the controllers to create multiple lighting seenes and themes.Ensure each fixture responds correctly to DMX signals. 5. Testing and Commissioning-Test each lighting fixture individually to ensure proper operation. -Verify that the programmed scenes and themes are executed correctly. -Adjust programming as needed to meet the design specifications. 6. Approval Process: -Present the programmed lighting scenes and themes to the consultant/architect for approval -Make any required adjustments based on feedback.7. Documentation and Training Document the programming and commissioning process.- Provide training to relevant personnel on how to operate and maintain the lighting system.8. Final Verification: - Conduct a final walkthrough with the consultant/architect to ensure all requirements are met,- Obtainal approval and sign-off. Inculding Caseing made of SS, with 05 year O&M Complete in all respect.. |
| 8 | Supply, Installation and testing of electrical pannel having 63 Amp MССВ 2P with 5 outgoing of 16 amp MCB. Pannel with timmer & surge proctation device Including casing made of SS with five year O&M Complete in all Respect. |
| 9 | Supply, Installation and testing of 3 Phase Servo Stablizer with minimum capicity of 30KVA, Oil cooled with 180-260 VAC Including casing made of SS with five year O&M Complete in all Respect. |
| 10 | Supply and laying of 2.5 Sq mm 3 core PVC insulated unarmoured multistrand copper cable as per site requirement. Including casing made of SS with five year O&M Complete in all Respect. |
| 11 | Supply and laying of 6 Sq mm 5 core PVC insulated unarmoured copper cable as per site requirement Including casing made of SS with five year O&M Complete in all Respect. |
| 12 | Supply and laying of Armoured CAT 6 cable as per site requirement. Including casing made of SS with five year O&M Complete in all Respect. |
| 13 | Supply and Laying of PVC/HDPE pipe 32 MM as per site requirement |
| 14 | Supply and burgn 600x 600mm x 3mm copper plate vertically for earthing with its top at least 3 metres below ground level complete gat Rmm da G.1 pipe and funnel for watering and two earthing lead oftwo no. 8 SWG copper wire in 15mm dia G1 pipe up to switch rd (from appron to switch board the cost of G.1. pipe and copper wire will be extra) 30cm squareCT. trame with hinged coxer masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround ete.complete in all respect. (Pw Schedule 2018 item no 705) Including casing made ofSS with five year O&M Complete in all Respect |
| 15 | Supply and fixing IP 67 boxes with all accessories as per site requirement Please Enable Macros to View BoQ information |