| Sl. No. | Item Description |
| 1 | CIVIL WORKS |
| 2 | Pump House Cum Chloronome Room:-Soil Investigation, preparing plan & elevation carrying structural designas per relevant seismic zone and Construction of Pump House Cum-Chloronome with foundation as per requirement of structural design of size 3.60Mx3.0Mx3.0M &1.80 Mx2.60Mx3.0 M by pass chamber including supply of all materials,labour, T&P etc. required for proper completion of work as per indicative departmental type design subject to approval of Engineer-in-charge. |
| 3 | Girder Pillar:- Construction of Girder Pillar Type for rebore of tubewell including supply of all materials, labour, T&P etc. required for proper completion of work as per indicative departmental type design. |
| 4 | REPAIRING OF EXISTING PUMP HOUSES IN ZONE -1 |
| 5 | Supply and fixing of M.S. Angle iron 40x40x5mm door chaukhat including supply and fixing of four hinges with one coat of red oxidised primer. |
| 6 | 1.20 x 2.10 M |
| 7 | 1.00 x 2.10 M |
| 8 | Supply and fixing of the Z-section M.S. Window with grill as per departmental drawing including supply and fitting of handle, locking arrangement etc. with one coat of red oxidised primer. |
| 9 | R.C.C. work(with use of C.C. mixer) in 1:1.5:3 proportion of cement, coarse sand and 20mm nominal size(10mm-1 part & 20 mm - 2 part) stone grit with proper finishing including supply of all materials, labour, T&P and Kachcha plaster on wooden plank shuttering or ply shuttering excluding cost of steel but including binding the same with 24 B.W.G. binding wire. |
| 10 | Lintels and R.C.C. Baffle Wall |
| 11 | 40mm thick 1:2:4 plain cement concrete floor with cement, coarse sand and 20 mm nominal size(10-20 mm) stone grit laid in panel and finished with 3mm floating coat of neat cement including 75mm thick base concrete consisting of cement, coarse sand and stone ballast 40mm nominal size(20-40 mm) in proportion of 1:4:8 and removing all over lapping of mortar at the joints of the panels if any and giving them uniform finishing including supply of all materials, labour, T&P etc. required for proper completion of the work |
| 12 | 12mm thick plaster above plinth in 1:4 cement and coarse sand over brick work, minimum thickness not to be less than 10mm including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 13 | 6 mm thick plaster on ceiling, sunshades and projected slab of R.C.C. work in 1:4 cement and Coarse Sand including supply of all materials, labour, T&P etc. complete for proper completion of the work. |
| 14 | Providing 45 cm wide and 25mm thick C.C apron of 1:2:4 cement, coarse sand and 10-20mm stone grit over 75mm thick base concrete in 1:4:8 cement, coarse sand and 40mm nominal size(20mm-2 part & 40 mm-6 part) stone ballast with finishing of 3 mm thick floating coat of neat cement also including supply of all materials,labour,T&P etc. complete. |
| 15 | The outer surface of wall finish with two coat of weather coat-All Guard, Apex-Ultima(Premium Acrylic Smooth Exterior Paint with Silicon Additive) with one coat of priming coat of exterior primer over smooth base of white cement based wall putty such as Birla, J.K. wall Putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 16 | The inner finish should be two coat of oil bound distemper Ist quality such as Bison distemper, tractor distemper with one coat of priming coat over smooth base of cement based wall putty such as Birla, J.K. wall Putty over the plastered wall surface to prepare the surface even and smooth including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 17 | Supply and fixing of ISI Marked waterproof Flush Door shutters of required size of 35 mm thick including heavy size steel fitting e.g. tower bolt, sliding bolt, handle etc., lab our, T&P etc.complete but excluding painting. |
| 18 | Supply and fixing of 4 mm thick glass panes in panel of Z-section windows shutter including supply of M.S. Clip and I.S.I. Mark putty etc. as required for proper completion of the work. |
| 19 | Supply and fixing of rain water pipe P.V.C. 110mm 6 Kg/Cm2(2 Nos.) with bend and clamp etc. all complete. |
| 20 | Painting or varnishing of new iron work in small areas or new wood work with one coat of priming and two coats of synthetic enamel paint or varnish including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 21 | Providing 15cm long 25 mm dia P.V.C. Pipe spout with slant cutting at ends and fixing the same with rich cement and coarse sand mortar in sunshades. |
| 22 | Supply and fixing 3 mm thick glass strips in floor and aprons panels in 1:3 cement and coarse sand mortar. |
| 23 | 25x3mm |
| 24 | 40x3mm |
| 25 | Including above Item no 4.00 to 25.00 |
| 26 | Repair of Existing RCC OHT under Zone-1 (900KL/16 M) |
| 27 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after . The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. Note: - This item to be used for maintenance work judicially , necessary deduction for scaffolding in the existing item to be done. |
| 28 | Surface Preparation:- Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge |
| 29 | 25mm average thickness |
| 30 | Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and allowing it to dry , all complete as per direction of Engineer-In-Charge. Bars above 12 mm dia |
| 31 | Provision of following works-Provison for the surface of structure to be treated for strengthening to be roughened properly either by raking joints or by hacking the cement concrete surface with a specially made hacking tool or other wise alternatively to make the surface rough and dust free by providing spatter key or wire brush. |
| 32 | Injection grouting in vertical surface/wall Placing and fixing nozzle by drilling machine in tank wall having minimum dia of Nozzle 15mm and provided on a regular interval not exceeding 1m including construction joints. Injection of pidicrete AM (polymer based on shrinkage high strength grout) admixed with cement through nozzles under pressure by sump @ 250 gms per bag of cement. Sealing the nozzle after grouting with Polymer product mixed with cement. |
| 33 | Repairing of spalled and lose concrete where reinforcement is exposed apply like fixit rust remover by means of brush to the reinforcement for clearing bars and steel surface then apply a bonding coat of acreylic based polymer with cement slurry in 1:1 ratio to the pre-wet cencrete by brush. Now apply the mixture of 1:1 cement, coarse sand to the prepared substrate when primer becomes tacky. of 50 mm thick M25 grade.(Taking 20% of total surface area of OHT) |
| 34 | Change of S.S. ladder inside the tank, repair of M.H. cover of top dome, change of masquoto jali with new one complete. |
| 35 | Supply and fixing of 20 mm dia G.I. pipe railling in stair case and balcony. Taking only 50% new and 50% old materials) |
| 36 | Supply and fitting of lighting conductor on top dome and making earthing with required earthing wire from top to bottom of tank as per direction of engineer in charge. |
| 37 | 100 mm thick 1:4:8 plain cement concrete and 100 mm thick RCC M15 flooring with apron with 3mm floating coat of neat cement including supply of all materials, labour, T&P etc complete. |
| 38 | Painting of outer surface of OHT from Top to bottom with weather proof paint (like apex etc.) as per direction of engineer incharge. |
| 39 | RCC work with cement, coarse sand and 20mm gauge approved stone ballast in proportion of 1:1.5:3 in slabs excluding supply of reinforcement and fixing and binding the same with 0.50mm thick binding wire (to be supplied by the contractor) centering and supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 40 | Mild steel or iron work in plain work such as R.C. or R.B. work (When not included, in over all rates) brought to required shape, as necessary including binding for proper completion of work including supply of steel and wastage. |
| 41 | 1st class brick work in 1:4 cement and Coarse sand mortar in damaged portion of boundary wall including supply of all materials labour, T&P etc. required for proper completion of the work. |
| 42 | 12mm thick plaster with cement mortar consisting cement coarse sand in ratio 1:4 work minimum thickness not to be less than 10mm on boundary wall including supply of all materials, labour T&P etc. required work. |
| 43 | Painting on boundary wall with one priming coat and one coat of approved exterior paint like Apex including supply of all labour, material T&P etc. required for proper completion of work. |
| 44 | Painting on iron work in small areas with one coat priming and one coat of approved paint including supply of all materials, labour and T&P etc. required for proper completion of the work. |
| 45 | Dismantling of reinforce Cement concrete or reinforce brick work including sorthing and stacking of serviceable of disposal of unserviceable material within a distance of 50m. |
| 46 | Removal of silt and dismantle concrete debris deposited inside the container portion and its desposal, washing, disinfecting & cleaning etc. complete. |
| 47 | Supply of all material,labour, T&P etc. for fixing of additional vertical pipe for existing OHT of 12 m staging |
| 48 | Including above Item no 27.00 to 48.00 |
| 49 | Dismantling of 300 KL Rcc Tank |
| 50 | Dismantling of ESRs of various capacities and heights using crane (10 MT capacity) and handing over M.S./ C.I./G.I. pipes, valves, bends, etc. to the Department. However taking steel reinforcement by the dismantling agency including removing dismantled materials from site and disposing them at suitable place as directed, etc. complete.Capacity :- 300 KL |
| 51 | Capacity of ESR above 2 Lakh litre and staging upto 12 m height. |
| 52 | Open Area |
| 53 | ( Including above Item no 50.00 to 53.00) |
| 54 | Construction of R.C.C. OH Tank under Zone-2 (01 No. 1100 KL/22 M) |
| 55 | Supply all materials, labours and t&p etc. required at the site of work and construct R.C.C. over head tank abovementioned capacity and staging staging including the cost of construction of following appurtenant works. |
| 56 | 2 Column stair |
| 57 | 1m wide R.C.C. stair case from ground upto the balcony of the tank |
| 58 | Lightening conductor as per Indian electricity rules. |
| 59 | Water level indicator as per deptt. specification |
| 60 | 20 mm. S.S. pipe (light quality) railing with 50 x 50 x 6 mm. 1.2 m. high angle iron posts1.5 m. c/c on both sides of the stair case (pipe in 3 rows) and balcony (pipe in 3 rows) |
| 61 | 50cm. wide M.S. ladder with 50x50x6 angle iron and 20 mm. rungs at 25 cm. c/c/, from balcony to the top dome of the tank and from there to the bottom dome of the tank inside it. |
| 62 | 60x60 cm. M.S. manhole cover (light pattern)with locking device. |
| 63 | Supply, erection, fixing in position and jointing of following D.I.D/F pipes with sluice valves and specials |
| 64 | ISI marked D.I.D/F pipes, class 'A' as per IS-1537/1960 |
| 65 | Inlet - 150 mm - 27, - 2 Nos. |
| 66 | Outlet - 350 mm - 22 m |
| 67 | Over flow - 350 mm - 27 m |
| 68 | Washout - 100 mm - 22 m |
| 69 | ISI marked C.I.D/F sluice valves as per IS- 780/1969 |
| 70 | Outlet - 350 mm |
| 71 | Washout - 100 mm - 1 No |
| 72 | ISI marked d.I.D/F specials as per IS 1538 |
| 73 | Clamping the vertical pipes with columns by clamps of 50 x 6mm. M.S. flat 1.5m c/c/ including the cost of all jointing materials such as nut bolts and washers etc. |
| 74 | Weather coat painting on outer surfaces of R.C.C. work with ISI marked cement paint in 3 coats. |
| 75 | Painting of M.S. ladder, railing and vertical pipes with ISI marked enamel paint in 3 coats. |
| 76 | Floor and apron at the ground level upto 15cm. beyond the entire projected area of the O.H.T. with 25mm. 1:2:4 P.C.C. over 75 mm., P.C.C. 1:4:8 as per deptt. specifications. |
| 77 | Sluice valve chambers - 2 Nos. (As per type design) |
| 78 | Testing of tank for water tightness etc. for propoer completion of the work. |
| 79 | Site. clearance |
| 80 | Zone-2 (1100 KL /22M) |
| 81 | Deduction on staging |
| 82 | Provision for soil investigation |
| 83 | Including above Item no 55.00 to 83.00 |
| 84 | Construction of R.C.C. OH Tank under Zone-3 (01 No. 850 KL/22 M) |
| 85 | Supply all materials, labours and t&p etc. required at the site of work and construct R.C.C. over head tank abovementioned capacity and staging staging including the cost of construction of following appurtenant works. |
| 86 | 2 Column stair |
| 87 | 1m wide R.C.C. stair case from ground upto the balcony of the tank |
| 88 | Lightening conductor as per Indian electricity rules. |
| 89 | Water level indicator as per deptt. specification |
| 90 | 20 mm. S.S. pipe (light quality) railing with 50 x 50 x 6 mm. 1.2 m. high angle iron posts1.5 m. c/c on both sides of the stair case (pipe in 3 rows) and balcony (pipe in 3 rows) |
| 91 | 50cm. wide M.S. ladder with 50x50x6 angle iron and 20 mm. rungs at 25 cm. c/c/, from balcony to the top dome of the tank and from there to the bottom dome of the tank inside it. |
| 92 | 60x60 cm. M.S. manhole cover (light pattern)with locking device. |
| 93 | Supply, erection, fixing in position and jointing of following D.I.D/F pipes with sluice valves and specials |
| 94 | ISI marked D.I.D/F pipes, class 'A' as per IS-1537/1960 |
| 95 | Inlet - 150 mm - 25, - 2 Nos. |
| 96 | Outlet - 350 mm - 20 m |
| 97 | Over flow - 350 mm - 21 m |
| 98 | Washout - 100 mm - 20 m |
| 99 | ISI marked C.I.D/F sluice valves as per IS- 780/1969 |
| 100 | Outlet - 350 mm |
| 101 | Washout - 100 mm - 1 No |
| 102 | ISI marked d.I.D/F specials as per IS 1538 |
| 103 | Clamping the vertical pipes with columns by clamps of 50 x 6mm. M.S. flat 1.5m c/c/ including the cost of all jointing materials such as nut bolts and washers etc. |
| 104 | Weather coat painting on outer surfaces of R.C.C. work with ISI marked cement paint in 3 coats. |
| 105 | Painting of M.S. ladder, railing and vertical pipes with ISI marked enamel paint in 3 coats. |
| 106 | Floor and apron at the ground level upto 15cm. beyond the entire projected area of the O.H.T. with 25mm. 1:2:4 P.C.C. over 75 mm., P.C.C. 1:4:8 as per deptt. specifications. |
| 107 | Sluice valve chambers - 2 Nos. (As per type design) |
| 108 | Testing of tank for water tightness etc. for propoer completion of the work. |
| 109 | Site. clearance |
| 110 | Zone-3 (850 KL /22M) |
| 111 | Deduction on staging |
| 112 | Provision for soil investigation |
| 113 | Including above Item no 85.00 to 113.00 |
| 114 | Distribution System Zone -1, Zone- 2 & Zone- 3 |
| 115 | Supply of following sizes HDPE Pipe PN-6: Class PE-100 for distribution system conforming to latest/ relevant I.S. 4984/2016 Specifications with all jointing materials and specials conforming to latest / relevant I.S. specifications including F.O.R. destination and all taxes and insurance etc. with loading unloading but excluding the cost of trenches all complete as per instructions of Engineer -in - charge. |
| 116 | 90 mm dia HDPE Pipe PN-6, PE:100 |
| 117 | 110 mm dia HDPE Pipe PN-6, PE:100 |
| 118 | 140 mm dia HDPE Pipe PN-6, PE:100 |
| 119 | 160 mm dia HDPE Pipe PN-6, PE:100 |
| 120 | Supply of HDPE specials as per conformation to I.S.S. suitable for above HDPE pipes F.O.R. destimation including all taxes and insurance (5% of HDPE Pipe Cost) |
| 121 | Supply of following sizes (D.I.) pipes for rising main/distribution system conforming to latest/relevant I.S. 8329/2000 Specifications with all jointing materials such as specials conforming to latest/relevant I.S. specifications suitable for D.I pipes as per IS-1239 /2000 and IS 8329/2000 or their latest amendment including F.O.R. destination and all taxes and insurance etc. with loading unloading but excluding the cost of trenches. All complete as per instructions of Engineer -in - charge. |
| 122 | 200 mm dia DI Pipe K-7 |
| 123 | 250 mm dia DI Pipe K-7 |
| 124 | 300 mm dia DI Pipe K-7 |
| 125 | 350 mm dia DI Pipe K-7 |
| 126 | Supply of DI specials as per conformation to I.S.S. suitable for above DI pipes F.O.R. destimation including all taxes and insurance (10% of Di pipe Cost) |
| 127 | Supply of ISI marked S&S Centrifugally Cast (Spun) Ductile Iron pipes as per IS : 8329-2000 suitable for Push on jointing by compatible rubber gasket confirming to IS : 9523 : 1980 at divisional store including all taxes |
| 128 | 150 mm dia DI K-9 |
| 129 | Supplying the following dia DI butterfly /sluice valves, class I, working pressure 10 Kg/cm2 confirming to IS: 780/1969 or its latest amendments, including valve fittings & Dismantling Joints as per requirement F.O.R. destination, and lowering them into the already prepared trenches, complete and also including supply of jointing materials etc. complete .including all taxes and insurance, as per instructions of Engineer -in -charge. |
| 130 | Sluice valve |
| 131 | 80 mm dia |
| 132 | 100 mm dia |
| 133 | 150 mm dia |
| 134 | 200 mm dia |
| 135 | 250 mm dia |
| 136 | 300 mm dia |
| 137 | 350 mm dia |
| 138 | Scour valve |
| 139 | 80 mm dia |
| 140 | Supply of single / double ball type air valve conforming to latest/relevent I.S. specifications including all taxes and insurance, complete (including supply of jointing materials and Valve fittings etc complete) as per instructions of Engineer. |
| 141 | 50 mm |
| 142 | Supply of under ground sluice value type fire hydrant consisting of 80 mm dia sluice valve, 80mm dia tail pieces, 80mm dia duck foot bend and 80 mm dia standard makes iron coupling with cap and etc. complete conforming to latest/relevent I.S. specifications including all taxes and insurance up to site of work (including supply of jointing materials and Valve fittings etc. complete as per instructions of Engineer ‐in ‐ charge. |
| 143 | Excavation of earth in ordinary soil (loam clay or sand) for pipe line and rising main trenches including lift upto 1.50 m and lead upto 50 m and refilling watering ramming of the excavated earth into the trench and also disposal of surplus earth upto 50m from the center of the trenches including supply of all material labour T&P etc complete as per instructions of Engineer -in -charge. (OD+600)mm |
| 144 | In ordinary soil |
| 145 | Carting from store (upto 8Km. or within municipal limit which is more) following sizes of HDPE pipes, specials coupling (Electrofusion Joint), fittings etc.to the site of work. Lowering the same into trenches and laying to true alignment and gradient including testing of pipe lines (excluding trenching), but including cutting of pipes for making joints. |
| 146 | 90 mm dia HDPE Pipe PN-6, PE:100 |
| 147 | 110 mm dia HDPE Pipe PN-6, PE:100 |
| 148 | 140 mm dia HDPE Pipe PN-6, PE:100 |
| 149 | 160 mm dia HDPE Pipe PN-6, PE:100 |
| 150 | Carting from store (upto 8Km. or within municipal limit which is more) following sizes of D.I. pipes, specials fittings etc. to the site of work. Lowering the same into trenches and laying to true alignment and gradient including testing of pipe lines, cutting of pipes for making joints. |
| 151 | 150 mm Dia DI Pipe K-9 |
| 152 | 200 mm dia DI Pipe K-7 |
| 153 | 250 mm dia DI Pipe K-7 |
| 154 | 300 mm dia DI Pipe K-7 |
| 155 | 350 mm dia DI Pipe K-7 |
| 156 | Carting of sluice valves / scour valve from store to site of works (upto 8Km. or within municipal limit which is more) of following sizes to site of work, lowering in already prepared trenches and fixing them in position ,making flange joints including supply of all materials such as bolts, nuts, rubber insertion, white lead, testing etc . complete. |
| 157 | Sluice valve |
| 158 | 80 mm dia |
| 159 | 100 mm dia |
| 160 | 150 mm dia |
| 161 | 200 mm dia |
| 162 | 250 mm dia |
| 163 | 300 mm dia |
| 164 | 350 mm dia |
| 165 | Scour Valve |
| 166 | 80 mm dia |
| 167 | Carting from store to site of works (upto 8Km. or within municipal limit which is more) of following sizes screwed down air valve to site of work, fixing in position including boring and threading in the main etc.complete including cost of boring the water main and subsequent back filling but excluding cost of air valve. |
| 168 | 50 mm |
| 169 | Carting from store to site of works(upto 8Km. or within municipal limit which is more) of 80mm dia size flanged fire hydrant to site of work, fixing them in position for flanged joints . |
| 170 | Supply of all materials, labour, T&P etc. and construction of sluice valve/scour valve chamber as per type design. |
| 171 | Surface box type including supply and fixing of 150mm x 150 mm size surface box. (upto 125 mm dia valve) |
| 172 | Masonry type with RCC cover (more than 150 mm dia valve) |
| 173 | Supply of all materials, labour T&P etc. and construction of air valve chamber complete required for proper completion of the work as per type design (with RCC cover) |
| 174 | Supply of all materials, labour, T&P etc. and construction of fire hydrant chamber complete required for proper completion of the work as per type design (with RCC cover) |
| 175 | Design and construct Thrust Block made in R.C.C. with cement, coarse sand & 20 mm gauge stone ballast in proportion of 1:1.5:3, for pipe line, including supply of MS reinforcement wrought to required shape as necessary ,its bending, fixing & binding the same with 0.50 mm thick binding wire in position & necessary centering & shuttering including curing and supply of all materials, labour, T & P etc. required for proper completion of the work and as per specifications for RCC work as per instructions of Engineer -in -charge. |
| 176 | Providing reinforcement of Thrust block for reinforced concrete work including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with wire at every inter-section, complete as per drawing and direction. |
| 177 | Making Nala crossing falling on alignment of pipe line including cost of D.I. pipe one no. (5.50m length) including supply of all materials, labour, T&P, etc complete required for proper completion of work. |
| 178 | 100 mm dia |
| 179 | 150 mm dia |
| 180 | 200 mm dia |
| 181 | 250 mm dia |
| 182 | 300 mm dia |
| 183 | 350 mm dia |
| 184 | Dismantling of following type of road surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto distance of 50m. and also including temporary reinstatement of road by old materials. |
| 185 | Bituminous Road as per NP specs |
| 186 | Bituminous Road as per PWD specs |
| 187 | Brick Road (BOE) |
| 188 | Inter locking tile Road |
| 189 | CC Road |
| 190 | Permanent reinstatement of following type of road surface including sorting out and stacking of serviceable materials and disposal of unserviceable materials upto distance of 50m. |
| 191 | Bituminous Road as per NP specs |
| 192 | Bituminous Road as per PWD specs |
| 193 | Brick Road (BOE) |
| 194 | Inter locking tile Road |
| 195 | CC Road |
| 196 | Road Crossing - Excavation in foundation of trench of proper size in soil mixed with moorum, Shingle, Kankar, soft rock, hard rock, including refilling, dressing and ramming earth or sand or bajri, ballast, including providing, supply, carting, lowering, laying and jointing of casing pipe of Ductile Iron with appropriate size, with rubber ring joint, sand filling in gap inside pipe, insertion of distribution pipe into the encasing pipe including supply of T&P, including concrete of 150 mm thick in with 40mm gauge brick ballast local sand and cement in proportion of 8:4:1, provision for barricading, labour for traffic diversion etc. Complete for proper completion of work as per instruction of Engineer. |
| 197 | 100 mm dia. Pipe |
| 198 | 150 mm dia. Pipe |
| 199 | 200 mm dia. Pipe |
| 200 | 250 mm dia. Pipe |
| 201 | Providing new water supply house connection to the consumers from new distribution pipe line of following diameters including making ferrule connection, cost of ferrule, 20 mm/15 mm dia HDPE and GI pipe, saddle piece, ball valve, specials, excavation, refilling of pit etc. complete. It also includes supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 202 | In all type of soil and rock |
| 203 | Connection on Line of 90 mm Dia |
| 204 | Connection on Line of 110 mm Dia. |
| 205 | Connection on Line of 140 mm Dia. |
| 206 | Connection on Line of 160 mm Dia. |
| 207 | Connection on Line of 200 mm Dia. |
| 208 | Connection on Line of 250 mm Dia. |
| 209 | Connection on Line of 300 mm Dia. |
| 210 | Shifting of Existing house connection from existing pipe line to new pipe line including supply of all materials, labour, T&P etc. required for proper completion of the work. |
| 211 | Provide all materials, labour and T&P to construct single roomed staff quarter as per type design and quantities of unit estimate all complete |
| 212 | Staff Quarter:- Soil Investigation, preparing plan & elevation carrying structural design as per relevant seismic zone and Supply of all meterials, labour, T&P, complete and construction of Single Room Staff quarter for pump operator, chaukidar, pump attendent and other as per indicative departmental type design subject to approval of Engineer-in-charge. |
| 213 | Boundray Wall, Approach Road and Gate in Zone-1,2&3 |
| 214 | Supply of all materials, labour T&P etc. for construction of boundary wall as per departmental type design at water works required for proper completion of work. |
| 215 | Supply and fixing of 3.60 m wide main gate & 1.20 m wide wicket gate including construction of pillars as per departmental type design including supply of all materials, labour, T&P etc. required for proper completion of works. |
| 216 | Supply of all materials, labour T&P etc. and construct CC road in water works compound. |
| 217 | Construction of 300x300 mm size drain |
| 218 | Ground Water Recharge, Lighting & Landscaping in Campus, etc in Zone 2&3 |
| 219 | Construction of Artificial Recharging of Ground water hrough roof top rain water of pump house, bypass chamber’s water & overflow of O.H.T. supplying of all material, pipes, grates, etc. complete in all respect. (Unit Estimate Attached) |
| 220 | Provision of Lighting in campous as per direction of Engineer-in-charge including all materials , labour T&P etc complete. |
| 221 | Water Campus |
| 222 | Pump House Campus |
| 223 | Provision of land Scapping and aboriculture in campus as per direction of Engineer-in- charge including all materials, labour T&P etc complete. |
| 224 | Construction of MCS Room, supplying of all material, pipes, grates, etc. complete in all respect. (Unit Estimate Attached) |
| 225 | E&M WORKS |
| 226 | Zone-01 |
| 227 | Construction of New & Rebore Tubewells |
| 228 | Transportation, Erection & Dismantling of Rig Machine |
| 229 | Transportation of Tubewell Assembly |
| 230 | Transportation, Erection & Dismantling of 350 PSI Compressor |
| 231 | Transportation, Erection & Dismantling of 3 Cusec O.P Unit |
| 232 | Drilling of 625 mm. dia bore from G.L. to 70 m BGL. |
| 233 | Drilling of 550 mm.dia bore from 70 M bgl to 100 m BGL. |
| 234 | Drilling of 550 mm.dia bore from 100 M bgl to 200 m BGL. |
| 235 | Drilling of 550 mm.dia bore from 200 M bgl to 220 m BGL. |
| 236 | Bentonite Clay |
| 237 | Flushing of Bore |
| 238 | M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required up to 50% of plain pipes) well cap, bail plug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. |
| 239 | 300 mm.dia size |
| 240 | 200 mm.dia size |
| 241 | Lowering of 300X200 mm.dia tube well assembly duly welded including welding electrode and shrouding of pea gravel complete in all respect. |
| 242 | 300mm dia MS ERW pipe from G.L. to 65 m BGL |
| 243 | 200 mm.dia M.S ERW plain/ slotted pipe from 65 m BGL to 100 m BGL |
| 244 | 200 mm.dia M.S ERW plain/ slotted pipe from 100 m BGL to 200 m BGL |
| 245 | Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 |
| 246 | DEVELOPMNET OF TUBE WELL |
| 247 | Development of Tube well by 350 PSI Compressor |
| 248 | Development of Tube well by 3 Cusec O.P. Unit |
| 249 | TEST : |
| 250 | Chemical and Bacteriological test of water sample from departmental approved lab |
| 251 | Electrical Logging of the Bore |
| 252 | Arrangement of Watch & ward during construction work |
| 253 | PUMPING PLANT & INSTRUMENTATION For New & Existing Tubewells (1 NEW TW ,1 REBORE TW AND 1 EXISTING) |
| 254 | SITC of 800 / 850 LPM, 65 M head, (Both tentative) Submersible pump motor set with 24m 100mm dia coloum pipe, NRV, CI D/F Bend 90º, CI A/F Tee, D/F Pipe (1.5 m long 02 nos & 1.0 m long 01 no) Earthing, Painting, Tools sets, wiring of pump house internal & external, Chain pulley block & all Pumping Plant accessories with nut bolts and rubber packing etc complete job in all respect. |
| 255 | Submersible Pump Motor Set 800 LPM, 65 M head, (Both tentative) as Spare |
| 256 | SITC of Scada compatible Servo Voltage Stabilizer of suitable capacity with all required necessary accessories like SPP, TDR, HL cut off, RS 485 port for scada compatibility, overload protection, bypass arrangement and body earthing etc complete in all respect. |
| 257 | 3M long heavy duty coloum pipe (spare) |
| 258 | Scada compatible automatic chlorination System one working & one standby |
| 259 | CE/UL Certified Intelligent Smart Energy Meter |
| 260 | Motor Operated Actuator with 100 mm dia DI sluice valve |
| 261 | CE/UL Certified Electromagnetic Flowmeter of size 100 mm |
| 262 | Digital Soft starter / VFD with RS485 Port- 400V Class, 22 KW or higher suitable Rating. |
| 263 | CE/UL Certified Pressure transmitter |
| 264 | CE/UL certified hydrostatic type sub soil water level transmitter for tubewells |
| 265 | Auto Phase Reversal Unit Suitable for above pumping plant with Inbuilt time delay and Enclosure (confirmation to IEC:60947-1 & IEC: 60947-b-1) 250 Amp |
| 266 | CE/UL certified surge protector for control panel |
| 267 | CE/UL Certified 7\\" HMI Touch screen suitable to communication with PLC/RTU for local display and control of process parameter |
| 268 | Control panel with IP-54 protection industrial grade for all equipments separate for control 24V and power equipments |
| 269 | Complete cabling for Tubewell including all power & control cables of all equipments at pump house and OHT |
| 270 | Automation Work of New & Existing Tubewells |
| 271 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 272 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification |
| 273 | Installation, Testing and Commissioning for one Tubewell |
| 274 | Trial run for three months period for one Tubewell |
| 275 | AUTOMATION WORK AT ESR Zone-01 |
| 276 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 277 | CE/UL Certified Radar type level transmitter for OHT |
| 278 | E&M WORKS REQUIRED AT ESR FOR ZONE-01 |
| 279 | Isolation DI Sluice Valve with Actuator (Outlet of ESR) 400 mm |
| 280 | Electro Magnetic Flowmeter (Outlet of ESR) Size 400 mm |
| 281 | Spare Actuator of Isolation DI Sluice Valve for ESR |
| 282 | Pressure Transmitter with display |
| 283 | Automatic Chlorination System |
| 284 | Chlorine Analyser |
| 285 | smart pressure transmitter |
| 286 | control panel with all other required equipment for scada |
| 287 | CE/UL certified Suitable capacity UPS with batteries at ESR for operation of actuators & other equipments if required |
| 288 | Zone-02 |
| 289 | Construction of New Tubewells |
| 290 | Transportation, Erection & Dismantling of Rig Machine |
| 291 | Transportation of Tubewell Assembly |
| 292 | Transportation, Erection & Dismantling of 350 PSI Compressor |
| 293 | Transportation, Erection & Dismantling of 3 Cusec O.P Unit |
| 294 | DC Drilling up to 200 M |
| 295 | Drilling of 625 mm. dia bore from G.L. to 70 m BGL. |
| 296 | Drilling of 550 mm.dia bore from 70 M bgl to 100 m BGL. |
| 297 | Drilling of 550 mm.dia bore from 100 M bgl to 200 m BGL. |
| 298 | Drilling of 550 mm.dia bore from 200 M bgl to 220 m BGL. |
| 299 | Bentonite Clay |
| 300 | Flushing of Bore |
| 301 | M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required up to 50% of plain pipes) well cap, bail plug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. |
| 302 | 300 mm.dia size |
| 303 | 200 mm.dia size |
| 304 | Lowering of 300X200 mm.dia tube well assembly duly welded including welding electrode and shrouding of pea gravel complete in all respect. |
| 305 | 300mm dia MS ERW pipe from G.L. to 65 m BGL |
| 306 | 200 mm.dia M.S ERW plain/ slotted pipe from 65 m BGL to 100 m BGL |
| 307 | 200 mm.dia M.S ERW plain/ slotted pipe from 100 m BGL to 200 m BGL |
| 308 | Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 |
| 309 | DEVELOPMNET OF TUBE WELL |
| 310 | Development of Tube well by 350 PSI Compressor |
| 311 | Development of Tube well by 3 Cusec O.P. Unit |
| 312 | TEST : |
| 313 | Chemical and Bacteriological test of water sample from departmental approved lab |
| 314 | Electrical Logging of the Bore |
| 315 | Arrangement of Watch & ward during construction work |
| 316 | PUMPING PLANT & INSTRUMENTATION FOR New Tubewells |
| 317 | SITC of 800 / 850 LPM, 65 M head, (Both tentative) Submersible pump motor set with 24m 100mm dia coloum pipe, NRV, CI D/F Bend 90º, CI A/F Tee, D/F Pipe (1.5 m long 02 nos & 1.0 m long 01 no) Earthing, Painting, Tools sets, wiring of pump house internal & external, Chain pulley block & all Pumping Plant accessories with nut bolts and rubber packing etc complete job in all respect. |
| 318 | Submersible Pump Motor Set 800 LPM, 65 M head, (Both tentative) as Spare |
| 319 | SITC of Scada compatible Servo Voltage Stabilizer of suitable capacity with all required necessary accessories like SPP, TDR, HL cut off, RS 485 port for scada compatibility, overload protection, bypass arrangement and body earthing etc complete in all respect. |
| 320 | 3M long heavy duty coloum pipe (spare) |
| 321 | Scada compatible automatic chlorination System one working & one standby |
| 322 | CE/UL Certified Intelligent Smart Energy Meter |
| 323 | Motor Operated Actuator with 100 mm dia DI sluice valve |
| 324 | CE/UL Certified Electromagnetic Flowmeter of size 100 mm |
| 325 | Digital Soft starter / VFD with RS485 Port- 400V Class, 22 KW or higher suitable Rating. |
| 326 | CE/UL Certified Pressure transmitter |
| 327 | CE/UL certified hydrostatic type sub soil water level transmitter for tubewells |
| 328 | Auto Phase Reversal Unit Suitable for above pumping plant with Inbuilt time delay and Enclosure (confirmation to IEC:60947-1 & IEC: 60947-b-1) 250 Amp |
| 329 | CE/UL certified surge protector for control panel |
| 330 | CE/UL Certified 7\\" HMI Touch screen suitable to communication with PLC/RTU for local display and control of process parameter |
| 331 | Control panel with IP-54 protection industrial grade for all equipments separate for control 24V and power equipments |
| 332 | Complete cabling for Tubewell including all power & control cables of all equipments at pump house and OHT |
| 333 | Automation Work of Tubewell |
| 334 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 335 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification |
| 336 | Installation, Testing and Commissioning for one Tubewell |
| 337 | Trial run for three months period for one Tubewell |
| 338 | AUTOMATION WORK AT ESR Zone-02 |
| 339 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 340 | CE/UL Certified Radar type level transmitter for OHT |
| 341 | E&M WORKS REQUIRED AT ESR FOR ZONE-02 |
| 342 | Isolation DI Sluice Valve with Actuator (Outlet of ESR) 400 mm |
| 343 | Electro Magnetic Flowmeter (Outlet of ESR) Size 400 mm |
| 344 | Spare Actuator of Isolation DI Sluice Valve for ESR |
| 345 | Manual Pressure Transmitter with display |
| 346 | Automatic Chlorination System |
| 347 | Battery operated / electricity or both (as per engineer encharge) Chlorine Analyser |
| 348 | smart pressure transmitter |
| 349 | control panel with all other required equipment for scada |
| 350 | CE/UL certified Suitable capacity UPS with batteries at ESR for operation of actuators & other equipments if required |
| 351 | Zone-03 |
| 352 | Construction of New Tubewells |
| 353 | Transportation, Erection & Dismantling of Rig Machine |
| 354 | Transportation of Tubewell Assembly |
| 355 | Transportation, Erection & Dismantling of 350 PSI Compressor |
| 356 | Transportation, Erection & Dismantling of 3 Cusec O.P Unit |
| 357 | DC Drilling up to 200 M |
| 358 | Drilling of 625 mm. dia bore from G.L. to 70 m BGL. |
| 359 | Drilling of 550 mm.dia bore from 70 M bgl to 100 m BGL. |
| 360 | Drilling of 550 mm.dia bore from 100 M bgl to 200 m BGL. |
| 361 | Drilling of 550 mm.dia bore from 200 M bgl to 220 m BGL. |
| 362 | Bentonite Clay |
| 363 | Flushing of Bore |
| 364 | M.S. Tubewell assembly with all required parts like plain pipe, slotted pipe (as required up to 50% of plain pipes) well cap, bail plug, clamp, reducer, centre guide, support structure etc as required & as per typed design complete in all respect. |
| 365 | 300 mm.dia size |
| 366 | 200 mm.dia size |
| 367 | Lowering of 300X200 mm.dia tube well assembly duly welded including welding electrode and shrouding of pea gravel complete in all respect. |
| 368 | 300mm dia MS ERW pipe from G.L. to 65 m BGL |
| 369 | 200 mm.dia M.S ERW plain/ slotted pipe from 65 m BGL to 100 m BGL |
| 370 | 200 mm.dia M.S ERW plain/ slotted pipe from 100 m BGL to 200 m BGL |
| 371 | Supply of 1.6 mm to 4.8 mm size pea gravel duly screened and washed as per IS 4097 |
| 372 | DEVELOPMNET OF TUBE WELL |
| 373 | Development of Tube well by 350 PSI Compressor |
| 374 | Development of Tube well by 3 Cusec O.P. Unit |
| 375 | TEST : |
| 376 | Chemical and Bacteriological test of water sample from departmental approved lab |
| 377 | Electrical Logging of the Bore |
| 378 | Arrangement of Watch & ward during construction work |
| 379 | PUMPING PLANT & INSTRUMENTATION FOR New Tubewells |
| 380 | SITC of 800 / 850 LPM, 65 M head, (Both tentative) Submersible pump motor set with 24m 100mm dia coloum pipe, NRV, CI D/F Bend 90º, CI A/F Tee, D/F Pipe (1.5 m long 02 nos & 1.0 m long 01 no) Earthing, Painting, Tools sets, wiring of pump house internal & external, Chain pulley block & all Pumping Plant accessories with nut bolts and rubber packing etc complete job in all respect. |
| 381 | Submersible Pump Motor Set 800 LPM, 58 M head, (Both tentative) as Spare |
| 382 | SITC of Scada compatible Servo Voltage Stabilizer of suitable capacity with all required necessary accessories like SPP, TDR, HL cut off, RS 485 port for scada compatibility, overload protection, bypass arrangement and body earthing etc complete in all respect. |
| 383 | 3M long heavy duty coloum pipe (spare) |
| 384 | Scada compatible automatic chlorination System one working & one standby |
| 385 | CE/UL Certified Intelligent Smart Energy Meter |
| 386 | Motor Operated Actuator with 100 mm dia DI sluice valve |
| 387 | CE/UL Certified Electromagnetic Flowmeter of size 100 mm |
| 388 | Digital Soft starter / VFD with RS485 Port- 400V Class, 22 KW or higher suitable Rating. |
| 389 | CE/UL Certified Pressure transmitter |
| 390 | CE/UL certified hydrostatic type sub soil water level transmitter for tubewells |
| 391 | Auto Phase Reversal Unit Suitable for above pumping plant with Inbuilt time delay and Enclosure (confirmation to IEC:60947-1 & IEC: 60947-b-1) 250 Amp |
| 392 | CE/UL certified surge protector for control panel |
| 393 | CE/UL Certified 7\\" HMI Touch screen suitable to communication with PLC/RTU for local display and control of process parameter |
| 394 | Control panel with IP-54 protection industrial grade for all equipments separate for control 24V and power equipments |
| 395 | Complete cabling for Tubewell including all power & control cables of all equipments at pump house and OHT |
| 396 | Automation Work of Tubewell |
| 397 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 398 | GSM/GPRS based wireless communication with 4G modem for RTU/PLC capable to transfer and gather data from remote sites to control stations all accessories included with signal enhancer antenna made for pumping plant internet charges as specified in tender technical specification |
| 399 | Installation, Testing and Commissioning for one Tubewell |
| 400 | Trial run for three months period for one Tubewell |
| 401 | AUTOMATION WORK AT ESR FOR ZONE-03 |
| 402 | CE&UL Certified PLC/RTU in IP54 enclosure suitable to communicate with GSM based modem unit with CPU and Power supply with analog and digital parameter and features as specified, for each Tubewell /OHT to store and transmit data on GSM backbone, RTU/PLC designed with logic to transfer data at multiple stations as specified in tender technical specification |
| 403 | CE/UL Certified Radar type level transmitter for OHT |
| 404 | E&M WORKS REQUIRED AT ESR DMA-01 FOR ZONE-03 |
| 405 | Isolation DI Sluice Valve with Actuator (Outlet of ESR) 350 mm |
| 406 | Electro Magnetic Flowmeter (Outlet of ESR) Size 350 mm |
| 407 | Spare Actuator of Isolation DI Sluice Valve for ESR |
| 408 | Pressure Transmitter with display |
| 409 | Automatic Chlorination System |
| 410 | Battery operated / electricity or both (as per engineer encharge) Chlorine Analyser |
| 411 | smart pressure transmitter |
| 412 | control panel with all other required equipment for scada |
| 413 | CE/UL certified Suitable capacity UPS with batteries at ESR for operation of actuators & other equipments if required |
| 414 | Chlorine of trial run for new, Rebore & existing (09 Nos) Tubewells till hand over of scheme to concerning ULB |
| 415 | Power Consumption of all newTubewells (07 Nos) till hand over of scheme to concerning ULB |
| 416 | Trial run For Three Months of all new, Rebore & existing (09 Nos) Tubewells including all operating and maintenance staff as per tender/DPR till hand over of scheme to concerning ULB |
| 417 | SCADA DISPLAY (MCS) |
| 418 | CE/UL & BIS certified industrial grade LED Monitor with latest configuration as per specification, 65\\" |
| 419 | Desktop PC including monitor i7 processor with UPS as per specification mentioned in technical bid document |
| 420 | CE/UL certified 5 KVA UPS with batteries as per specification mentioned in technical bid document |
| 421 | Full development version of required TAGS SCADA software with customization of software for MCS as per requirement as per specification mentioned in technical bid document |
| 422 | CE/UL certified master control room PLC with redundant CPU & power supply at MCS in IP 54 encloser as per specification mentioned in technical bid document |
| 423 | CE/UL certified Field gateway agent for transferring data from MCS to Central control room |
| 424 | All in one computer with i7 processor including wireless keyboard, mouse as per specification mentioned in technical bid document for scada execution & monitoring at Jal Nigam Office. |
| 425 | GSM based wireless/ Broadband/ Equipment communication system for PLC capable to transfer & received data & gather data from remote sites to control station. All accessories included signal enhancer antenna along with running expenses till DLP |
| 426 | CE/UL Certified Firewall for network protection |
| 427 | Surge protector for Ethernet communication protection |
| 428 | CE/UL Certified industrial grade Ethernet Switch |
| 429 | Mobile App Facility system architecture (industries internet based & viewed through apps for increased local & Remote Visibility |
| 430 | Canon/HP or equivalent Laser Printer 1108 plus 02 Nos (01 Nos for mcs room & other one nos for jal nigam office) or equivalent |
| 431 | Security Surveillance IP Camera with recorder |
| 432 | Installation, commissioning and testing including required furniture, A/C, etc. |
| 433 | Trial run of all other E&M / Automation equipments installed at MCS Room of Scheme with Electricity, Data transmission & Operation charges till hand over of scheme to concerning ULB Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail