| 1 | SCHEDULE ‘A’ PART-I (SCHEDULE OF ITEMS) |
| 2 | M&L for Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in conceled/ surface / recessed PVC conduit or Caping-N-Casing with and including modular switch, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required all as specified and directed (Group C) |
| 3 | M&L for Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit or caping-N-casing including 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required |
| 4 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 5 | 2 way 5/6 Amps modular Switch |
| 6 | 15/16 Amp modular switch |
| 7 | 3/5 Pin 5/6 Amp modular socket out let |
| 8 | 6 Pin 15/16 Amp modular socket outlet. |
| 9 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 10 | Supplying and fixing fowlloing size/ modules GI box along with modules base & cover plate for modular swithes in recess etc as required. (a) 1 or 2 module (75mmx75mm) |
| 11 | (b) 3 modules (100mmx75mm) |
| 12 | (c) 4 modules (125mmx75mm) |
| 13 | (d) 6 modules (200mmx75mm) |
| 14 | (e) 8 modules (125mmx125mm) |
| 15 | (f) 12 modules (200mmx150mm) |
| 16 | Supplying and fixing 3 pin 5 Amp ceiling rose on the existing junction box/ etc as requied . |
| 17 | Earthing with GI earth plate 600mmx600mmx3mm thick including accessorise and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc with charcoal/ coke and salt as required. |
| 18 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 19 | Supplying and fixing PVC batten / angle holder incl connection as reqd complete all as specified and directed |
| 20 | Supply only PVC ventilation fan 200 mm sweep complete all as directed by Engr-in-Charge. |
| 21 | Fixing only Exhaust fan of any sweep/type incuding making all electric connections complete all as specified and directed. |
| 22 | Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 8 way, 240 valts on surface/recess complete, with tinned copper bus bar, neutral bus bar, earth bar, din bar,inter connection, powder pointed including earthing etc as requied (But with out MCB/RCCB/Isolater) |
| 23 | Supplying and fixing following way single pole and neutral, sheet steel MCB distribution board 12 way, 240 valts on surface/recess complete, with tinned copper bus bar, neutral bus bar, earth bar, din bar,inter connection, powder pointed including earthing etc as requied (But with out MCB/RCCB/Isolater) |
| 24 | S&F in replacement of MCB 'C' Curve type, 10 kA, 5 to 32 Amp, Single Pole and neutral with over load and short circuit protection complete all as directed. |
| 25 | S&F in replacement of MCB 'C' Curve type, 10 kA, 5 to 32 Amp, Single Pole with over load and short circuit protection complete all as directed. |
| 26 | Wiring for circuit/ submain wiring alongwith earth wire with the 2x1.5 sq mm+1x1.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as requed.. |
| 27 | Wiring for circuit/ submain wiring alongwith earth wire with the 2x2.5 sq mm+1x2.5 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as required. |
| 28 | Wiring for circuit/ submain wiring along earth wire with the 2x6 sq mm+1x6 sq mm earth wire of FRLS PVC insulated copper conductor, single core cable in casing caping as required. |
| 29 | Supply only LED , Tube light fitting 20 W, 6500K Intenso AX LED batten aluminium profile self ballasted surface mounted LED Batten extruded aluminium body with PC diffuser in unic shape. >180º wide light distribution. soft glare free light complete accessories. |
| 30 | Fixing only pre-wired light fittings of LED of 18W flurecent/compact fluoverscent fitting with all accessories on ceiling/wall including connetion with 1.5 sqmm FRLS PVC insulated, copper inductor, single core cable and earthing etc as required all as specified and directed. |
| 31 | SCHEDULE ‘A’ (SCHEDULE OF CREDIT) |
| 32 | Old U/S point wiring including switches (Rs 10.00 per point or more) |
| 33 | Old unserviceable earthing materials of any size/capacity( Rs 65 each or more) |
| 34 | Old unserviceable Distrubution Board of any size/capacity (Rs 25 each or more) |
| 35 | Old unserviceable MCBs of any size/capacity (Rs 5 each or more) |
| 36 | Old unserviceable light fitting of any size/capacity (Rs 5 each or more) |
| 37 | Old unserviceable Sub Main wiring of any size/capacity (Rs 8 RM or more) Please Enable Macros to View BoQ information |