| 1 | M&L for drilling holes in RCC structure at the interval of 0.45 mtr and packing the nozzle grouting pipe fixed with Renderoc plug or fast plug of make as approved by Accepting Officer ready to use rapid-setting, waterproof cement mortar. After injection, cut the nozzle and pack with Rendroc plug or equivalent make as approved by Accepting Officer ready to use, rapid- setting waterproof cement mortar complete all as specified and directed. |
| 2 | M&L for grouting into nozzle with cementitious injuction pressure grouting cement + Cebex 100 or equivalent make as approved by Accepting Officer two-part, cementitious injuction grouting and liquid @ 0.50 Kg/hole, packed with Rederoc plug and crack filling complete all as specified and directed. |
| 3 | M&L for cleaning all surfaces of RCC over head tank structure with wire brush or Nylon brush or water-pressure as directed by Engineer-in-Charge including removing all loose particles from surface and applying the following in sequence:-(a) After cleaning the suraface, all pipes packed with Sika grout and periphery of pipe pack with Sikadur-694 F(I) or equivaqlent solvent free epoxy resin resin based putty (Confirming to ASTM C882) for Corner's cobbing(b) Applying priming coat with Sika Raintite I or equivalent acrylic polymer emulsion for enhancing the properties of mortar, concrete, grout or cement slurry in ration 1:2:4 (Chemical:Water:Cement); CEmentous injection grouting will be done as per requirement at site situations (d) After priming coat make corner cobbing and repair the cracks with repair mortar in ratio 1:4:10:40 (Chemical:Water:Cement:Sand:Stone Dust as per required) (e) After repairing and corner's Cobing Apply the primimg on the Whole surface and on the priming coat laying Fibre mesh (f) Applying 1st coat of two component SikaTop-109 Seal IN (High performance flexible acrylic cementitious waterproofing coating) & 2nd coat after 6-8 hours or next day with two component SikaTOP-109 Seal IN (High Performance fleible acrylic cementitius waterproofing coating)(g) Ponding tests will be done after 7 days after completion of work complete all as specified and directed |
| 4 | M&L for applying Sikagard-67 or equivalent make water based, solvent free, odorless, epoxy resin protective coating, Food grade (USFDA 175.300 1st April 2017) from CFTRI, Mysore complete all specified and directed. |
| 5 | M&L for providing and erecting steel props (upto full height, braced at centre, resting on wedge and block to support the structure provisionally during repair work and maintaining them in position till reqd and as directed. |
| 6 | M&L for Chipping of loose/ damaged /cracked / previously repaired / delaminated or weak concrete by chieseling to expose the sound core concrete where ever required and to expose rusted reinforcement upto depth n.exc 50mm and disposal of rubbish off the premises to a distance not exc 50 mtrs including cleaning of reinforced concrete surface by air compressor complete all as specified and directed. |
| 7 | M&L for applying rust remover cum passivator to remove rust from existing reinforcement by using product as approved by GE, with density 1.01 Kg/ltr at 30 degree celsius and consumption : 0.2 Kg/Sqm/coat complete all as specified and directed.Note: The materials to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar). |
| 8 | M&L for applying cement based polymer modified rebar corrosion protection system to existing reinforcement using cement based polymer modified rebar corrosion protection system with consumption : 3.75 kg/Sqm for two coats and Product requirements: carbonation resistance: 2 mm of chemical compound as approved by GE corresponds to 20 mm of normal mortar; bond strength > 1N / Sqmm according to ASTM C 882-78 complete all as specified and directed.Note: The material to be applied thoroughly on exposed rebars only with the help of a brush of suitable size. The area will be measured as length of bar x two times the dia of bar) |
| 9 | M&L for providing, mixing & applying two component Epoxy resin concrete Bonding coat on prepared RCC surfaces as per manufacturer's specification including prepartaion of surface throughly and cleaning complete where ever required with using Product: Sikadur®-32 LP of Sika or equivalent in Fosroc / Thermax as approved by GE with Consumption: 0.4 kg/Sqm and Product requirements: Complies with ASTM C 881-78, Type II Grade 2 Class B+C complete all as specified and directed. |
| 10 | M&L for providing by mixing and trowel application of prepacked, light weight, two component structural grade polymer modified fibre reinforced thixotropic cement mortar as approved by GE at an average thickness exceeding 10mm and upto 25mm to the prepared concrete surface in soffit of slabs, beam, columns, parapets, fins and facias at any height, including finishing of applied Polymer mortar as per the technical specifications and manufacturer's instructions complete all as specified and directed . |
| 11 | M&L for weld-mesh of size 75x75x3mm to be wrapped on the exposed surface of rib of beam & on the slab bottom and tack welding to the exposed reinforcement at close intervals and gunite with cement mortar 1:3 mixed with admixture Sika Plasto creat plus or equivalent make in Fosroc / Thermax as per manufacturer's instructions as approved by GE around rib of beam or roof slab of thickness n.exc 40mm to be applied under an operating pressure. The gunited surface to be cured properly for a min of 7 days all in complete as per the technical specifications and manufacturer's instructions and directed. |
| 12 | M&L for providng and fixing rebar of required length & diameter (160mmx16mm) with Epoxy Resin wherever required in RCC members including power drilling ,cleaning of holes, then rebars should be inserted in holes that should be filled with epoxy to ensure the bond as per manufacturer recommendation complete as per site requirement and directions. |
| 13 | Taking down cement plaster on concrete surface wall, ceiling etc including raking out joints hacking for key scrubbing with water including removing rubbish complete all as specified and directed. |
| 14 | M&L rendering 15 mm thick in CM 1:4 with and including mixing of liquid WPC of approved make @ 200ml per bag of cement / manufacturer's instructions on brick/concrete wall surfaces of any description, and finishing the surfaces even and fair complete complete all as specified and directed..Note : WPC shall be measured and paid seperately. |
| 15 | Supply only Sika or equivalent in Fosroc / Thermax as water proofing compound. complete all as specified and directed |
| 16 | Demolition of cement concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed |
| 17 | M&L for 75 mm thick cement concrete type C1, 1:3:6 (using 20mm graded stone aggregates) as in plinth protection and PCC paved area, finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed. |
| 18 | Taking down chowkats or frames with shutter (without taking off shutter from the frames) not exc 1.50 Sqm each complete all as specified and directed. |
| 19 | S&F factory made single extruded WPC (Wood Polymer omposite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 45 x 85 mm mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum pressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. |
| 20 | S&F factory made single exturded WPC (Wood Polymer Composite) solid plain flush door shutter of 30mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flameof Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In-Charge. |
| 21 | S&F SS butt hinges medium weight of size 100 mm fixed with screws complete all as specified and directed. |
| 22 | S&F 250 mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts & sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 23 | S&F extruded aluminium alloy handles 150 mm long fabricated type anodised complete all as specified and directed. |
| 24 | Dismantling wrought iron or mild steel work of any description complete all as specified and directed |
| 25 | Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed |
| 26 | M & L for RCC M-25 (Design Mix) (using 20 mm graded crushed stone aggregates) as in spiral staircase complete all as specified and directed |
| 27 | M & L for TMT bars for reinforcement 10mm dia and over cut to lengths, bent to shape required including cranking, bending etc and binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed |
| 28 | M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; for rough finshed surface of flat surfac exceeding 200mm thick complete all as specified and directed |
| 29 | M&L for stainless steel Framed work such as for portions framed and hung as Ladder, including pintle hinges, stops, hand-made sliding bolts, etc.grills, gratings, etc. with ends of bars houldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to 304 Grade complete all as specified and directed |
| 30 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of Fe 410-W (Gde -E-250) quality-A fixed complete all as specified and directed |
| 31 | M&Lfor preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed |
| 32 | M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces of wall/ceiling complete all as specified and directed . |
| 33 | M&L for preparing, washing, rubbing down and complete removal of existing treatment for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over old surfaces of wall/ceiling complete all as specified and directed . |
| 34 | M&L for factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ ceosetory windows and other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/Sqmm , modules of elasticity 900 N/Sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note : For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra cost on this account shall be made all as specified and directed. |
| 35 | S&F 28mm to 30mm thick factory made solid WPC door shutter consisting of density 650 Kg /Cum manufactured by an ISO-9001-2015 certified company , door to be panelled with stainless steel mosquito mesh and XTN aluminium mesh for additional strength and safety purpose (confirming as per IS:4020) complete all as specified and directed.Note:- The door should be water proof, termite proof, fire retardant and having screw holding capacity. |
| 36 | S&F 100mm long mild steel butt hinges medium weight complete all as specified and directed. |
| 37 | S&F 150mm long cast type anodised aluminium handle complete all as specified and directed. |
| 38 | S&F 200mm long aluminium anodised tower bolts of extruded section and fixed, complete all as specified and directed. |
| 39 | S&F 140mm overall length of cover plate, floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring and vulcanised rubber piece complete all as specified and directed. |
| 40 | S&F 300mm long mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed. |
| 41 | M&L for 15 mm thick rendering in CM (1:4) over wall surface of any description and material finished even and smooth without using extra cement including taking down of existing rendering complete all as specified and directed |
| 42 | M&L for applying two coats of oil bound distemper over a coat of primer on walls, pillasters, cornices etc, on newly plastered surfaces using spounge roller including one coat of primer over 2mm thick wall care putty in two coats complete all as specified and directed. |
| 43 | Excavation in trenches not exceeding 1.5m depth and not exc 1.5m wide and getting out in hard / dense soil for laying cable/erecting poles complete all as specified and directed. |
| 44 | Returning and filling in soil including spreading levelling watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 45 | Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 46 | Taking up Cast iron water main of size 150mm dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed. |
| 47 | Taking up Cast iron water main of size 100mm dia including all fittings for spigot and socket ends and lead joints including burning out lead joint and recovering lead complete all as specified as directed. |
| 48 | Supplying, laying and testing 150mm nominal dia ductile iron pipe, spigot and socket including Rubber joints class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately. |
| 49 | Supplying, laying and testing 100mm nominal dia ductile iron pipe, spigot and socket including Rubber joints class K-7 complete all as specified and as directed. Note :- Specials and fittings shall be measured and paid separately. |
| 50 | S&F Ductile iron fittings such as bends (any type, radius and angle) tapers any type (straight, bend, increasing, decreasing or double socket etc) tee pieces single branch ‘Y’ junction, double branch, cross (all socket or socket and spigot or flanged and socket etc) color, caps and plugs suitable for DI pipe upto 150 mm dia complete all as specified and as directed. |
| 51 | M&L for construction of brick massonry valve pit chamber of inner dimension 100cmx100cmx100cm suitable for sluice valves upto 100mm size, with PCC 1:4:8, type D-2 for foundation, brick work in cm 1:6 rendering 1:4, 15mm plastering, coping in PCC 1:2:4 type B-1, incl necessary earth work, including MS sheet cover of thickness 3.15mm on 50x50x6.0 mm angle iron framework including two coats of synthetic enamelled paint over a coat of red oxide primer with making provision of locking arrangement including demolition of old valve pit complete all as specified and as directed. |
| 52 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts of 150mm dia complete all as specified and directed |
| 53 | S&F in repairs cast iron sluice valve PN 1.6 with both ends flanged confirming to the IS 14846 with brass spindle and iron wheel head flanged inclding new rubber gaskets, bolts and nuts of 100mm dia complete all as specified and directed |
| 54 | Cutting the existing pipe line insertion of Tee or fixing of slucie valves except DI specials complete all as specified and directed. Please Enable Macros to View BoQ information |