Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-05-2026 | PreBid Link | Other | 08-06-2026 |
| Sl. No. | Item Description |
| 1 | Part A: E&M |
| 2 | Schedule 1:Preventive & Corrective Maintenance Of Various E&M System |
| 3 | Schedule 2:Certification of Fire NOC & Form B, LUMPSUM Items |
| 4 | Schedule 3:UPS Maintainance |
| 5 | Schedule 4:Breakdown in any equipment which is not covered above if any (Charges for incidental & urforseen items) |
| 6 | Part B : OHE & PSI |
| 7 | Schedule 1:Preventive Maintenance for OHE (FOCS) |
| 8 | Schedule 2:Miscellaneous & consumable items including small tools etc. for OHE |
| 9 | Schedule 3:Preventive Maintenance for Power Supply (RSS. ASS & Switching Post) & Breakdown Maintenance activities |
| 10 | Schedule 4:Miscellaneous & consumable items including small tools etc. for PSI Annexure-I Annual Maintenance Contract of E&M, OHE, PSI for “11 Stations, One Depots and 2 RSS” of Navi Mumbai Metro Line-1 for 3 Year extendable upto further 1 Year. S.No. Description of Works Year 1 Amount (₹) incl. GST Year 2Amount (₹) incl. GST Year 3 Amount (₹) incl. GST Total Amount (₹) incl. GST for Three (3) Years A B C D=C*1.05 E=D*1.05 F=C+D+E Part A: E&M Schedule 1 Schedule I : Preventive & Corrective Maintenance Of Various E&M System 8347226.56 8764587.89 9202817.28 26314631.73 Schedule 2 Certification of Fire NOC & Form B, LUMPSUM Items 2553824.58 2681515.81 2815591.6 8050931.99 Schedule 3 UPS Maintainance 1816322.08 1907138.18 2002495.09 5725955.35 Schedule 4 Breakdown in any equipment which is not covered above if any (Charges for incidental & urforseen items) 1770000.0 1858500.0 1951425.0 5579925.0 Sub Total E&M 14487373.22 15211741.88 15972328.97 45671444.07 Part B : OHE & PSI Schedule 1 Preventive Maintenance for OHE (FOCS) 3948296.09 4145710.89 4352996.43 12447003.41 Schedule 2 Miscellaneous & consumable items including small tools etc. for OHE 236000.0 247800.0 260190.0 743990.0 Schedule 3 Preventive Maintenance for Power Supply (RSS. ASS & Switching Post) & Breakdown Maintenance activities 19656377.66 20639196.54 21671156.37 61966730.57 Schedule 4 Miscellaneous & consumable items including small tools etc. for PSI 1770000.0 1858500.0 1951425.0 5579925.0 Sub Total OHE & PSI 25610673.75 26891207.43 28235767.8 80737648.98 Grand Total including GST (Part A & B) for 3 Year 40098046.97 42102949.31 44208096.77 126409093.05 Part A : Schedule I : PREVENTIVE & CORRECTIVE MAINTENANCE OF VARIOUS E&M SYSTEM S.No. Service Descrption UOM Qty Rate in INR(incl GST) Amount in INR (incl. GST) A.1 PREVENTIVE AND CORRECTIVE MAINTENECE OF DIESEL GENERATOR A.1.1 Total 3 Preventive Maintenece Service Visits in a Year covering 1 Wet service (Including Consumables) and 3 Dry Service (Covering Check ups and Adjustments) PM will cover Engine Checks ,Alternator: Visual inspection and AVR settings check for abnormalities,Control Panel: Visual inspection for any irregularities,Battery: Visual inspection & check for abnormalities, battery charging if required. This includes Unlimited breakdown discovery visits for any breakdown complaints Following Units are covered. etc 380 kVA Kirlosker Make (11 nos Station) Nos 11.0 59000.0 649000.0 A.1.2 Total 4 Preventive Maintenece Service Visits in a Year covering 1 Wet service (Including Consumables) and 3 Dry Service (Covering Check ups and Adjustments) PM will cover Engine Checks ,Alternator: Visual inspection and AVR settings check for abnormalities,Control Panel: Visual inspection for any irregularities,Battery: Visual inspection & check for abnormalities, battery charging if required. This includes Unlimited breakdown discovery visits for any breakdown complaints Following Units are covered. etc 650 kVA Cummins Make (Depot) Nos 3.0 210331.46 630994.38 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR DIESEL GENERATOR (EXCLUSIVE OF GST) 1279994.38 A2 Schedule 1.1 PREVENTIVE MAINTENECE A2.1 MONTHLY maintenance of set of Fire Pumps & accessories As per Maha-Metro maintenance checklisti.e Automation check as per pressure settings,Tightness of pump couplings, Foundation bolts, Check pump currents/voltage etc.[11 Stations - 11 Set & One Depots (2 Set), TOTAL- 13 Set] Per Schedule 130.0 983.37 127838.1 A2.2 HALF YEARLY maintenance of Fire Pump, Butterfly Valves and other valvesset of Fire Pumps & accessories.As per Maha-Metro maintenance checklisti.e Alignment of pump coupling, Cleaning of Y-stainer, Check motor terminals, Check motor cooling fan blades,[11 Stations - 11 Set & One Depots (2 Set), TOTAL- 13 Set] Per Schedule 26.0 3496.45 90907.7 A2.3 QUARTERLY maintenance of set of FHCs and Yard hydrants. As per Maha-Metro maintenance checklisti.e Greasing of hose reel drum, Check operation of YH & arrest leakage if any, Operation of Valves, Check availibility of all accessories etc[11 Stations - 11 Set & One Depots (2 Set), TOTAL- 13 Set] Per Schedule 52.0 2840.86 147724.72 A2.4 QUARTERLY maintenance of set of Fire Extinguishers As per Maha-Metro maintenance checklisti.e. Measure weight, Check pressure, Inspect hose pipes etc[5 Stations - 11 Set & One Depots (5 Set), TOTAL- 16 Set] Per Schedule 64.0 1893.91 121210.24 A.2.5 Maintenance of Addressable type Fire detection & alarm system (FACP, Repeater Panel, Smoke/heat/ multi criterion detectors, MCP. Hooter cum flasher, RI, 12V- 26 AH battery of FACP complete circuit wiring for sensor and other associated components complete etc as required. ) installed at 2 nos elevated Metro stations. This Includes QUARTERLY 4 Nos of Preventive Maintenance and UNLIMITED Breakdown Calls. For system of 4 Loop Panel, Repeator Driver Board, Communication Board, Batteries & Battery Charger., Amplifier card, Provision for interfacing with other systems such as SCADA / BMS with all required Hardware & SoftwareMake- Morley by Honeywell -2 Nos (Central Park & Pethpada)Preventive Maintenance Includes Preventive maintenance of the Fire Alarm Control Panel (FACP), loop cards, power supply modules.Testing and calibration of all connected devices: Smoke detectors,Heat detector,MCPs (Manual Call Points),Hooter/sounders,Interface modules (Monitor/Control modules/Isolator Module),Battery health check and voltage reading,Software diagnostic using Notifier programming tools, Loop integrity check,Logging all events and faults during maintenance. Reprogramming if required due to minor configuration changes.Submission of detailed service reports. Per Schedule 8.0 8850.0 70800.0 A.2.6 Maintenance of Addressable type Fire detection & alarm system (FACP, Repeater Panel, Smoke/heat/ multi criterion detectors, MCP. Hooter cum flasher, RI, 12V- 26 AH battery of FACP complete circuit wiring for sensor and other associated components complete etc as required. ) installed at one elevated Metro stations.This Includes QUARTERLY 4 Nos of Preventive Maintenance and UNLIMITED Breakdown Calls. For System with 4 Loop Panel, Repeator Driver Board, Communication Board, Batteries & Battery Charger., Amplifier card, Provision for interfacing with other systems such as SCADA / BMS with all required Hardware & SoftwareMake- Simplex- 1 (Pethali-Taloja)Preventive Maintenance Includes Preventive maintenance of the Fire Alarm Control Panel (FACP), loop cards, power supply modules.Testing and calibration of all connected devices: Smoke detectors,Heat detector,MCPs (Manual Call Points),Hooter/sounders,Interface modules (Monitor/Control modules/Isolator Module),Battery health check and voltage reading,Software diagnostic using Notifier programming tools, Loop integrity check,Logging all events and faults during maintenance. Reprogramming if required due to minor configuration changes.Submission of detailed service reports. Per Schedule 4.0 8850.0 35400.0 A.2.7 Annual Maintenance contract of intelligent addressable fire detection & alarm system (Notifier Make) installed at Depot, comprising microprocessor based intelligent analog addressable automatic fire alarm control panel, loop cards, multi criterion detectors, smoke detectors, addressable heat detectors, manual call points, electronic sounders, monitor modules, relay modules, control modules, fault isolator modules, response indicators , network repeater panels, graphic softwares, DNR, power supply ,monitor, CPU, UPS, complete circuit wiring for sensor and other associated components complete etc as required. This Includes QUARTERLY 4 Nos of Preventive Maintenance and UNLIMITED Breakdown Calls For system 8 Loop Panel, Repeator Driver Board, Communication Board, Software & Graphics, , Batteries & Battery Charger., Amplifier card, With interfacing with other systems such as SCADA / BMS with all required Hardware & SoftwareMake - Notifier, Total - 4 Nos Depots Preventive Maintenance Includes Preventive maintenance of the Fire Alarm Control Panel (FACP), loop cards, power supply modules.Testing and calibration of all connected devices: Smoke detectors,Heat detector,MCPs (Manual Call Points),Hooter/sounders,Interface modules (Monitor/Control modules),Battery health check and voltage reading,Software diagnostic using Notifier programming tools, Loop integrity check,Logging all events and faults during maintenance. Reprogramming if required due to minor configuration changes.Submission of detailed service reports. Per Schedule 16.0 8850.0 141600.0 A.2.8 Annual Maintenance contract of intelligent addressable fire detection & alarm system (Notifier Make) installed at Amandoot & Pendhar Station , comprising microprocessor based intelligent analog addressable automatic fire alarm control panel, loop cards, multi criterion detectors, smoke detectors, addressable heat detectors, manual call points, electronic sounders, monitor modules, relay modules, control modules, fault isolator modules, response indicators , network repeater panels, graphic softwares, DNR, power supply ,monitor, CPU, UPS, complete circuit wiring for sensor and other associated components complete etc as required. This Includes QUARTERLY 4 Nos of Preventive Maintenance and UNLIMITED Breakdown Calls For system 8 Loop Panel, Repeator Driver Board, Communication Board, Software & Graphics, , Batteries & Battery Charger., Amplifier card, With interfacing with other systems such as SCADA / BMS with all required Hardware & SoftwareMake - Notifier, Total - 8 Nos ( Belapur, RBI Colony, Belpada, Utsav Chowk, Kendriya Vihar, Kharghar Village ,Amandodot & Pendhar Station) Preventive Maintenance Includes Preventive maintenance of the Fire Alarm Control Panel (FACP), loop cards, power supply modules.Testing and calibration of all connected devices: Smoke detectors,Heat detector,MCPs (Manual Call Points),Hooter/sounders,Interface modules (Monitor/Control modules),Battery health check and voltage reading,Software diagnostic using Notifier programming tools, Loop integrity check,Logging all events and faults during maintenance. Reprogramming if required due to minor configuration changes.Submission of detailed service reports. Per Schedule 32.0 8850.0 283200.0 A2.9 Maintenance of Addressable type Fire detection & alarm system (FACP, Repeater Panel, Smoke/heat/ multi criterion detectors, MCP. Hooter cum flasher, RI, 12V- 26 AH battery of FACP complete circuit wiring for sensor and other associated components complete etc as required. ) installed at 2 nos elevated Metro stations. This Includes QUARTERLY 4 Nos of Preventive Maintenance and UNLIMITED Breakdown Calls. For system of 4 Loop Panel, Repeator Driver Board, Communication Board, Batteries & Battery Charger., Amplifier card, Provision for interfacing with other systems such as SCADA / BMS with all required Hardware & SoftwareMake- Morley by Honeywell -2 Nos Receiving Sub Station ( Panchanand & Kharghar)Preventive Maintenance Includes Preventive maintenance of the Fire Alarm Control Panel (FACP), loop cards, power supply modules.Testing and calibration of all connected devices: Smoke detectors,Heat detector,MCPs (Manual Call Points),Hooter/sounders,Interface modules (Monitor/Control modules/Isolator Module),Battery health check and voltage reading,Software diagnostic using Notifier programming tools, Loop integrity check,Logging all events and faults during maintenance. Reprogramming if required due to minor configuration changes.Submission of detailed service reports. Per Schedule 8.0 8850.0 70800.0 A2.10 Rectification of Air trapping or Free rotation problems in fire pumps Nos 12.0 710.22 8522.64 A2.11 Replacement of coupling between motor and pump Nos 6.0 2840.87 17045.22 A2.12 Resolve fire pump tripping/automation issue Nos 24.0 710.22 17045.28 A2.13 Painting of Fire pipes & risers Mtrs 200.0 69.93 13986.0 A2.14 Repair/Replacement of Yard hydrant valve, NRV, four way fire brigade inlet valve,Butterfly valve Nos 20.0 568.17 11363.4 A2.15 Rectification of door/internal alignment of Yard hydrant cabinet box and Fire Hose cabinate . Nos 40.0 568.17 22726.8 A2.16 Re-painting of Yard hydrant cabinet box and other associated accerories. Nos 40.0 349.65 13986.0 A2.17 Re-painting of fire buckets and other associated accerories. Nos 40.0 174.84 6993.6 A2.18 Rectification/Replacement of expansion bellows,Pressure guage,Connector terminals, Air release valave,Ball valve,Y-stainer fil ter net,Pressure Switch Nos 30.0 568.16 17044.8 A2.19 Leakage rectification of hydrant line including welding Nos 30.0 568.17 17045.1 A2.20 Re-fixing of hangging clamp of fire extinguishers Nos 40.0 142.05 5682.0 A2.21 Re-painting of Fire Extinguishers and other associated accerories. Nos 1.0 227.25 227.25 A2.22 Repairing or replacing extinguishers accessories Nos 1.0 284.09 284.09 A2.23 Removal & Reinstallation of Pumps for Fire hydrant and sprinkler Nos 1.0 8304.08 8304.08 A2.24 Removal & Reinstallation of Jockey pump for Hydrent System and Sprinkler Nos 1.0 4152.04 4152.04 A2.25 Replace fire survival cable in case of any damage Mtr 40.0 148.6 5944.0 A2.26 Supply, Charging of Nitrogen gas for one Cylider trace tube laid in panel as per site conditions and relevant code practice (incl Transportation of Nitrogen Cylinder) including gas supply. Gas must withold atleast for 1 month after successful charging. Nos 60.0 768.89 46133.4 A2.27 Refilling & HTP testing of 2.5 LBS Cylinder Clean Agent FK 5112 system (With test certificate) as per site conditions Nos 4.0 4739.5 18958.0 A2.28 Refilling & HTP testing of 5 LBS Cylinder Clean Agent FK 5112 system (With test certificate) as per site conditions Nos 4.0 8211.08 32844.32 A2.29 Refilling & HTP testing of 10 LBS Cylinder Clean Agent FK 5112 system (With test certificate) as per site conditions Nos 2.0 14599.28 29198.56 A2.30 Supply,Installation of pressure gauge (Make-Rotarex,Firetec or similar) as per site conditions and relevant code practice Nos 6.0 760.52 4563.12 A2.31 Supply,Installation of pressure switch as per site conditions and relevant code practice Nos 6.0 2647.63 15885.78 A2.32 Supply,Installation of Cylinder Valve as per site conditions and relevant code practice Nos 6.0 2280.69 13684.14 A2.33 Supply,Installation of Straight Connector as per site conditions and relevant code practice.Work of Tube Replacament would be carried out in Non-Revenue Hours 01.00 to 04.00 Hrs Nos 10.0 138.28 1382.8 A2.34 Supply,Installation of T Type Connector as per site conditions and relevant code practice.Work of Tube Replacament would be carried out in Non-Revenue Hours 01.00 to 04.00 Hrs Nos 10.0 448.52 4485.2 A2.35 Supply,Installation of End Plug as per site conditions and relevant code practiceWork of Tube Replacament would be carried out in Non-Revenue Hours 01.00 to 04.00 Hrs Nos 10.0 352.41 3524.1 A2.36 Supply,Installation,Testing Commissioning of End Line Adapter as per site conditions and relevant code practice Nos 6.0 1611.24 9667.44 A2.37 Supply & Installation of Fire Trace Tube (Make:Fire Trace,Rotarex, SEVO etc.) as per site condition and UL & FM certified relevant code of practice. Mtr 50.0 594.86 29743.0 A2.38 Supply, Installation, Testing, Commissionig of Master Control Unit with inbuilt hooter, as per site condition and UL & FM certified relevant code of practice. Nos 4.0 5170.02 20680.08 B.2 MATERIAL SUPPLY FOR FIRE FIGHETING & FIRE DETECTION SYSTEM B. 2.1 Fire Extingusher CO2 Gas type of 4.5 Kg capacity conforming to IS:2878/15683 B. 2.1.1 Handle with PVC grip Nos 20.0 87.89 1757.8 B. 2.1.2 Horn Nos 20.0 113.0 2260.0 B. 2.1.3 Safety Clip with holder assembly (metal) Nos 20.0 37.67 753.4 B. 2.1.4 Painting of cylinder Nos 20.0 94.16 1883.2 B. 2.1.5 Control valve of Extinguishers Nos 20.0 767.25 15345.0 B. 2.1.6 Discharge Pipe Nos 20.0 209.25 4185.0 B. 2.2 Fire Extingusher ABC/DCP 5/6 Kg capacity conforming to IS:2171 B. 2.2.1 squeeze grip Assembly Valve Nos 20.0 244.13 4882.6 B. 2.2.2 Pressure Gouge Nos 20.0 125.55 2511.0 B. 2.2.3 Hose with nozzle Nos 20.0 153.45 3069.0 B. 2.2.4 Painting of cylinder Nos 20.0 94.16 1883.2 B. 2.3 Supplying and erecting 75/80 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV Each 4.0 4140.93 16563.72 B. 2.4 Supplying and erecting 100 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV Each 4.0 5361.21 21444.84 B. 2.5 Supplying and erecting 150 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV Each 4.0 8231.11 32924.44 B. 2.6 Supplying and erecting 200 mm dia. cast iron double flange butterfly valve of size complete with PN16 pressure rating, as per specification no. FF-VL/BFV Each 2.0 12764.92 25529.84 B. 2.7 Supplying and erecting 75/80 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV Each 4.0 7990.44 31961.76 B. 2.8 Supplying and erecting 150 mm dia cast iron double flange NRV complete with PN16 pressure rating, as per specification no. FF-VL/NRV Each 2.0 17551.12 35102.24 B. 2.9 Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV Each 2.0 7544.21 15088.42 B. 2.10 Supplying and installing wall mounting swinging hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) along with necessary accessories complete as per specification no. FF-FFA/HV Each 2.0 9003.87 18007.74 B. 2.11 Supplying and erecting 63mm dia, controlled percolation (C.P.) hose pipe, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/CPH Each 2.0 5143.96 10287.92 B. 2.12 Supplying and erecting 150 mm dia fire brigade header suitable for supplying water in fire tank complete as per specification no. FF-FA/FBC Each 2.0 12331.71 24663.42 B. 2.13 Supplying and erecting 100 mm dia. pressure gauge , 0-300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, erected with provided G.I.pipe, elbow etc. complete as per specification no. FF-FFA/PG Each 6.0 939.29 5635.74 B. 2.14 Supplying and erecting 12/15 mm dia pressure switch with provided isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS Each 2.0 2293.58 4587.16 B. 2.15 Supplying, installing, testing and commissioning of intelligent addressable thermal/ heat detector with rate of rise cum fixed temperature thermistor complete with base as required, suitable for temperature variations from - 20°C to 38 °C for fixed-heat and rate-of-rise type detectors whereas 0°C to 90°C for high heat type detectors, in built isolation mode, suitable for industrial/ kitchen/ boiler room etc. with 3 years equipment replacement warranty, IS : 2175-1988 reaffirmed 2000, IS 15908:2021 standards FF-AFAS/SD Each 50.0 3663.48 183174.0 B. 2.16 Supplying, installing, testing and commissioning of addressable manual call points ( break glass type/pull station type), made of addressable break glass plastic square in shape surface/flush mounted with \\"Break Glass\\" massage embedded on the glass, complete erected with mounting base and required accessories conforming to EN 54 or UL listed with 3 years equipment replacement warranty FF-AFAS/MCP Each 6.0 4650.9 27905.4 B. 2.17 Supplying, installing, testing and commissioning of addressable fire control/relay module complete as required, with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 reed relays, EN 54 or UL Listed FF-AFAS/CRM Each 8.0 4911.09 39288.72 B. 2.18 Supplying, installing, testing and commissioning of addressable fire monitor module complete as required. EN 54 or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/MM Each 8.0 4839.53 38716.24 B. 2.19 Supplying, installing, testing and commissioning of addressable fire isolator module complete as required. EN 54 /FM or UL Listed with 3 years equipment replacement warranty conforming to IS 5051Part 2 (Sec 1 to 3) : 1982 Reed relays FF-AFAS/ISM Each 8.0 3969.2 31753.6 B. 2.20 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required Each 24.0 359.06 8617.44 B. 2.21 Supplying, installing, testing and commissioning of addressable horn cum strobe sound/ hooter, output frequency 500 to 1000 Hz with dB as per Chart given in IS 15908:2021, with flashing at 1 Hz over the strobe’s entire operatingvoltage range EN 54, conforming to IS 2189: 2008, IS 15908:2021 standards with 3 years equipment replacement warranty FF-AFAS/SSH Each 6.0 10183.84 61103.04 B. 2.22 Supplying and erecting acrylic sheet 2 mm thick for covering wall entries including cutting, drilling and fixing with nut bolts / screws etc. complete. m2 50.0 1528.62 76431.0 B. 2.23 Supply, Installation, Testing & Commissioning of Signal Initiating (Intelligent Analogue Addressable) devices complete with Detector Base etc. as per Specifications. B. 2.23.1 Intelligent Addressable Multi Sensor Smoke Detector. Nos 20.0 4891.1 97822.0 A.2 & B2 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR FIRE DETECTION AND FIRE FIGHTING (EXCLUSIVE OF GST) 2335721.88 A.3 PREVENTIVE AND CORRECTIVE MAINTENECE OF HVAC system A.3.1 Routine QUARTERLY maintenance of HVAC SPlit IDU & ODU As per Maha-Metro maintenance checklisti.e Wet cleaning of evaporator & condensor coils, Cleaning of drain tray, Current/Voltage readings, Check thermostat working etc Per Schedule 1.0 1890.66 1890.66 A.3.2 Routine QUARTERLY maintenance of VRV IDUs, ODUS & Split AC's As per Maha-Metro maintenance checklisti.e Wet cleaning of IDU & ODU coils, Current/Voltage readings, Check thermostat working etc. Per Schedule 1.0 2763.27 2763.27 A.3.3 Routine HALF YEARLY maintenance of VRV IDUs & ODU & Split ACsAs per Maha-Metro maintenance checklisti.e Check availibility of refrigerent, Clean drain tray and pipe of each IDU, Inspect compressors for any abnormality etc. Per Schedule 1.0 5235.66 5235.66 A.3.4 VRV system cooling issue rectification, VRV system communication issue rectification Each 1.0 799.53 799.53 A.3.5 VRV's IDU /Split AC's IDU filter replacement Each 1.0 378.5 378.5 A.3.6 Attend VRV/Split AC Drain line choke up issue rectification,VRV/Splt AC indoor unit water lekage rectification, VRV IDU drain t ray repairing/replacement Each 1.0 708.99 708.99 A.3.7 Split AC capacitor, Contactor replacement Each 1.0 567.2 567.2 A.3.8 Leakage identification, Pipe brazing & Gas refilling if required Each 1.0 1963.38 1963.38 A.3.9 Replacement of Fan bearing Each 1.0 1600.15 1600.15 A.3.10 Replacement of PCB cards for ODU's & IDU's Each 1.0 3490.44 3490.44 A.3.11 Replacement Compressor and other capital equipments. Each 1.0 6980.88 6980.88 A.3.12 Replacement of sensor in IDU's & ODU's Each 1.0 785.35 785.35 A.3.13 Replacement of IDU acessories Blower motor/Drain pumps/Blower/Coils Etc for IDU Each 1.0 1308.92 1308.92 A.3.14 Comprehensive Annual Maintenance Contract - Split AC Unit (Inverter) - Non-Toshiba/Carrier at Stations, Depot & 2 nos RSS Tr 50.0 4071.0 203550.0 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR HVAC System (EXCLUSIVE OF GST) 232022.93 A. 4 PREVENTIVE AND CORRECTIVE MAINTENECE OF Domestic, Seepage, Sewage Pumps A. 4.1 Routine Monthly maintenance of Domestic, Sump & Sewage Pumps As per Maha-Metro maintenance checklisti.e Coupling tightness, Lekage arrest, Stainer Cleaning, Pump automation testing, Earthing Tightness, Float inspection11 Nos of Elevated Stations(1 Set/Station), One Depots (2 Set/Depot), 2 nos RSS ( 1 set/RSS )- TOTAL- 15 Set Per Schedule 180.0 1893.91 340903.8 A. 4.2 Rewinding of electric motor upto 1 H.P. single phase up to 1400 RPM of all types, makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. testing for the original speed and no load consumption with guarantee for one yeari.e Single Phase Tullu pumps Nos 2.0 1539.03 3078.06 A. 4.3 Rewinding of electric motor up to 1 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one yeari.e Domestic Pump Nos 2.0 1969.64 3939.28 A. 4.4 Rewinding of electric motor above 1 HP upto 2 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year i.e Domestic Pumps Nos 2.0 2287.08 4574.16 A. 4.5 Rewinding of electric motor above 2 H.P. upto 3 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with mino repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year i.e Domestic pump Motors Nos 2.0 2669.55 5339.1 A. 4.6 Rewinding of electric motor above 3 H.P.upto 5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year i.e Seepage Pumps Nos 4.0 4332.17 17328.68 A. 4.7 Rewinding of electric motor above 5 H.P. upto 7.5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year i.e Sump pump & Sewage Pummps Nos 2.0 5186.89 10373.78 A. 4.8 Rewinding of electric motor above 7.5 H.P. upto 10 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc. testing for the original speed and no load consumption with guarantee for one year i.e Jockey Pump Motors Nos 2.0 6144.39 12288.78 A. 4.9 Rewinding of electric motor above 10 H.P. upto 12.5 H.P. three phase up to 1400 RPM of all types and makes with copper wire, overhauling with minor repairs, lubricating of ball bearings & bush bearing, and replacing screws etc.testing for the original speed and no load consumption with guarantee for one year i.e Seepage Pumps in UG stations Nos 2.0 6280.99 12561.98 A. 4.12 Rewinding the motor of table / pedestal / wall bracket / cabin fans of all type and makes including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. Testing for original speed and consumption with guarantee for 1 year including transportation from site and back Job 2.0 659.58 1319.16 A. 4.13 Rewinding the motor of the ceiling fan 1200 mm / 1400 mm of all types , makes and over hauling including minor repairs lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year Job 2.0 718.12 1436.24 A. 4.14 Rewinding the motor of the Exhaust fan 900 / 1400 RPM 300 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year Job 2.0 718.12 1436.24 A. 4.15 Rewinding the motor of the Exhaust fan 900/1400 RPM 450 mm of all types, makes and over hauling including minor repairs, lubricating of ball bearings & bush bearing, and replacing condenser, screws etc. & testing for original speed and consumption with guarantee for one year Job 3.0 1222.89 3668.67 A. 4.16 Comprehensive Annual Maintenance of fountain type drinking water cooler A. 4.16.1 Annual Compressive Maintenance -UV Commercial Filter 120 LPH Nos 11.0 5985.3 65838.3 A. 4.16.2 Annual Comprehensive -OASIS Fountain type Water Cooler Nos 11.0 43640.31 480043.41 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR Domestic, Seepage, Sewage Pumps System (EXCLUSIVE OF GST) 964129.64 A 5 PREVENTIVE AND CORRECTIVE MAINTENECE OF LT Panel & DBs A. 5.1 Routine Yearly maintenance of LT panels As per Maha-Metro maintenance checklisti.e interlock for incomers, Operation of breakers, Manual spring charge, Cleaning breaker contact, Tightness of busbar etc of all LT panels of stations11 Nos of Elevated Stations(1 Set/Station), One Depots (2 set) , TOTAL- 13 set Per Schedule 13.0 1748.23 22726.99 A. 5.2 Routine Yearly earth value mesurements & and value marking & maintainance of Isolators & cleaning of DB's As per Maha-Metro mai ntenance checklist. i.e Checking earth values of MET,CETs, Corrective action if values are abnormal, Values marking, DB Tightness, Healthiness of indicators off all DBs and LT Panel at Stations11 Nos of Elevated Stations(1 Set/Station), One Depots (2 Set/Depot), TOTAL- 13 Set Per Schedule 13.0 3059.4 39772.2 A. 5.3 Preventive maintainance of High mast Half Yearly As per Maha-Metro maintenance checklist.i.e Greasing of chains, Greasing of Motor Gears, Replacing faulty lights,Heathiness of rope Highmast TOTAL-13 Nos Per Schedule 24.0 947.89 22749.36 A. 5.4 Replacement of closing, shunt ,undervoltage coils of ACB, MCCB Nos 14.0 983.38 13767.32 A. 5.5 Rectify automation issues, Including control wire issue rectification, Reconnect/ Replacing neutral links (MDB, EPP, ATS etc.) Nos 14.0 655.58 9178.12 A. 5.6 Rectify fault & Replace equipments inside panel (Ex MCB,Contactors,Timers,Relays,LVM,MFM,Voltmeters) Nos 20.0 786.71 15734.2 A. 5.7 Reconnecting the power cables by fixing new Lugs. Nos 14.0 1136.35 15908.9 A. 5.8 Rectifying ACB fault & including replacement of ACB/Major Internal equipments of ACB if required Nos 20.0 1420.44 28408.8 A. 5.9 Rectifying MCCB fault & Replacement of MCCB Below 125 Amps. Nos 20.0 1136.35 22727.0 A. 5.10 Rectifying MCCB fault & Replacement of MCCB above 125 Amps. Nos 20.0 1748.23 34964.6 A. 5.11 Replacement of CT's Nos 8.0 786.71 6293.68 A. 5.12 Replacement of Panel Lights/Heater/Sensor/Door lockes Hinges/Rotary knobs etc Nos 10.0 393.35 3933.5 A. 5.13 Replace isolator in case of any fault. Nos 10.0 786.71 7867.1 A. 5.14 Replacement of faulty equipment inside DBs or isolator (Ex. RCCB,MCB,Connectors, Contactor,Timers,spreader etc) Nos 10.0 491.69 4916.9 A. 5.15 Door lock replacement, Indicators replacement Nos 20.0 116.91 2338.2 A. 5.16 Laying of GI Strip & SS Strip with welding and termination including fixing of accessories Mtr 16.0 65.56 1048.96 A. 5.17 Refixing of LA spikes with accessories and connection with strips Nos 50.0 655.58 32779.0 A. 5.18 Repainting of earth strips, GI rods,Funnel Nos 50.0 17.49 874.5 A. 5.19 Treatment of Earthing Pits for achiving standard earth resistance values per pit. Nos 100.0 2185.29 218529.0 B.5 MATERIAL SUPPLY FOR LT PANEL B 5.1 Supplying and erecting 6 to 32 A, 10kA, SPMCB suitable to fix in 1 module of modular switch in provided box complete & duly concealed with necessary material and connected Each 10.0 275.8 2758.0 B 5.2 Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 10.0 325.24 3252.4 B 5.3 Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 20.0 226.37 4527.4 B 5.4 Supplying, erecting & marking DPMCB 6A to 32A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 16.0 696.01 11136.16 B 5.5 Supplying, erecting & marking DPMCB 40A to 63A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 4.0 927.57 3710.28 B 5.6 Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 4.0 1377.71 5510.84 B 5.7 Supplying, erecting & marking FPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB Each 4.0 1728.96 6915.84 B 5.8 Supplying and erecting 16 to 32 A, 10kA, DPMCB suitable to fix in 2 module of modular switch in provided box complete & duly concealed with necessary material and connected Each 4.0 307.02 1228.08 B 5.9 Supplying, erecting & commissioning 2 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB Each 14.0 2716.38 38029.32 B 5.10 Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB Each 4.0 2871.2 11484.8 B 5.11 Supplying, erecting & commissioning 4 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB Each 2.0 3470.93 6941.86 B 5.12 Supplying and replacing thermal overload relay for motor starter suitable for up to 12.5 HP Each 4.0 1529.92 6119.68 B 5.13 Supplying and replacing thermal over load relay for motor starter 10 H.P. to 17.5 H.P Each 4.0 1507.8 6031.2 B 5.14 Supplying and replacing thermal over load relay for motor starter 60 H.P. to 90 H.P Each 2.0 4120.11 8240.22 B 5.15 Supplying & replacing timer for STAR/DELTA motor starter up to 12.5 H.P Each 2.0 805.29 1610.58 B 5.16 Supplying & replacing Electronic timer above 30 H.P motor starter Each 2.0 1723.76 3447.52 B 5.17 Supplying & replacing contactor for DOL motor starter from 7.5 H.P. to 10 H.P Each 2.0 1376.41 2752.82 B 5.18 Supplying and replacing contactor for motor starter suitable for 75 H.P. to 90 H.P Each 2.0 21175.56 42351.12 B 5.19 Supplying and erecting selector switch suitable for voltmeter/ammeter for 3 phase AC supply 500V, 50Hz, on provided box / panel and duly connecting with necessary PVC wire leads and lugs Each 4.0 434.52 1738.08 B 5.20 Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meter with test certificates. Each 2.0 1336.08 2672.16 B 5.21 Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc. Each 50.0 322.64 16132.0 B 5.22 Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc. Each 10.0 460.54 4605.4 B 5.23 Supplying and erecting modular switch with LED indicator available to connect in a switch board to glow LED when connected load is off, on provided double mounting plate complete duly erected Each 10.0 157.41 1574.1 B 5.24 Supply of surface mounted 40Watt, LED Batten, with a system lumen output of 4400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire shall have a CRI of greater than 80 with rated system lifetime of 50,000 hours at L70. (Area having no False Ceiling, ASS Room, Corridor, Pump Room, Maintenance Room, Store Room etc). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BCLAB 40W LED) Nos 200.0 594.72 118944.0 B 5.25 Supply of LED 2'x2' recessed fixture, (34 Watt to 40Watt) with a system lumen output of 3800 lumens at a system efficacy of 120 lumen/watt. (For false ceiling equipment room, Concoure). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BCLAB 40W LED). Nos 100.0 1444.32 144432.0 B 5.26 Supply of highbay type 80 Watt LED Lighting Fixture. Fitting should have a aluminium pressure die cast housing with tempered glass for high transmittence. Luminaire should have system wattage of 80W with system efficacy of 120 lumens/W. It is designed to meet IP65 ensuring L70 for 50000 burning hours with PF of >0.95 with input voltage of 140-270V (for Street lighting). (80Watt LED Lighting Fixture similar to Bajaj Catalogue No. BGPPR 80W LED V2). Nos 50.0 4756.58 237829.0 B 5.27 Supply of surface mounted LED type Lighting Fixture of 10Watt, LED Bulkhead with a system lumen output of 600 lumens and a system efficacy of 60 lumen/watt. The luminaire shall be IP65 and shall have a CRI of 70. The housing of luminaire is made of high pressure die cast aluminium with front cover made of polycarbonate diffuser. (For Lift Shaft, Service Shaft ) Nos 50.0 169.92 8496.0 B 5.28 Supply of 18Watt, LED Downlighter with a system lumen output of 2000 lumens and a minimum system efficacy of 120 lm/W. The luminaire shall have a CRI greater than 80, lifetime of 50,000 hours at L70. Ingress Protection Classification of IP 20 (For Toilet). (18Watt LED Lighting Fixture similar to Bajaj Catalogue No. BZSLO 18W LED). Nos 50.0 594.72 29736.0 B 5.29 Supply of LED surface mounted luminaire with a system lumen output of 4000 lumens and a minimum system efficacy of 120 lm/W. The Luminaire shall be IP65 rated and shall have a life of 50k hours at L70. .(For Platform and staircase). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BI PC 40W LED XE) Nos 300.0 2124.0 637200.0 B 5.30 LED 1120 X 13.8 mm mcpcb 144 L (Any ISI) compatible for 40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BI PC 40W LED XE) Nos 100.0 849.6 84960.0 B 5.31 36 W Driver 900 mA (Any ISI) compatible for 40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BI PC 40W LED XE) Nos 100.0 531.0 53100.0 B 5.32 Supplying Signage LED Driver 400W With Following Specification Input 100-240VAC - 3.2 A 47-63 Hz , Outout +12V === 33.3ARated Power 400W IP 67 Nos 10.0 6085.26 60852.6 Supplying Signage LED Driver 300W With Following Specification Input 100-240VAC - 3.2 A 47-63 Hz , Outout +12V === 33.3ARated Power 300W IP 67 Nos 1.0 4024.98 4024.98 B 5.33 Supplying Signage LED Driver 200W with Following Specification,Input 100-240V 50/60Hz, Outout +12V, Rated Power 200WIP 67 Nos 1.0 3409.02 3409.02 B 5.34 Supplying Signage LED Driver 150W with Following Specification,Input 100-240V 50/60Hz,Outout +12V,Rated Power 150WIP 67 Nos 1.0 2920.5 2920.5 B 5.35 Supplying Signage LED Driver 102W with Following Specification, Input 100-240V 50/60Hz, Outout +12V,Rated Power 102WIP 67 Nos 1.0 2516.94 2516.94 B 5.36 Supplying Signage LED Driver 80W with Following Specification, Input 100-240V 50/60Hz, Outout +12V,Rated Power 80WIP 67 Nos 1.0 2155.86 2155.86 B 5.37 Supplying Signage LED Driver 36W with Following Specification, Input 100-240V 50/60Hz, Outout +12V, Rated Power 36WIP 67 Nos 1.0 1093.86 1093.86 B 5.38 Suppying LED Strip For Sigange Mtr 100.0 180.54 18054.0 B 5.39 Supplying and laying rigid steel conduit 16 SWG 25 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No: WG- MA/CC Mtr 100.0 288.82 28882.0 B 5.40 Supplying & erecting GI flexible Conduit 25 mm dia. conforming to I.S. with required number of couplings, bushes, check nuts etc. complete Mtr 100.0 63.74 6374.0 B 5.41 Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit Mtr 200.0 27.32 5464.0 B 5.42 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Mtr 360.0 80.66 29037.6 B 5.43 Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW Mtr 360.0 115.78 41680.8 B 5.44 Supplying and erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Mtr 720.0 120.99 87112.8 B 5.45 Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW Mtr 160.0 901.56 144249.6 B 5.46 Supplying and erecting modular type switch 16A duly erected on provided plate and box with wiring connections complete Each 100.0 137.91 13791.0 B 5.47 Supplying and erecting modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete. Each 100.0 208.15 20815.0 B 5.48 Supplying and drawing of 2x1.5 sq.mm. FRLSH grade copper wires with 1.5 sq.mm earth wire in provided concealed pipes for concealed type fan point wiring and terminating on modular accessories in box as per specification No: WG-PW/CW Point 60.0 692.11 41526.6 B 5.49 Providing Secondary point wiring for additional light/ bell point in PVC trunking (casing-capping) with 1.5 sq.mm (2+1E) FRLSH grade copper wire with required accessories as per specification No: WG-PW/SW Point 60.0 256.28 15376.8 B 5.50 Supplying and erecting electronic type Driver for Outdoor LED Fittings 101W- 150W suitable to operate on 230V A.C. 50 Hz. Having pf>0.95 and THD<10%. Each 1.0 2989.59 2989.59 B 5.51 Supplying Pedestal fan 400 mm. 230 Volts 50 cycles oscillating type complete with guard and regulator 3 meter. of flexible wire and hand shield type 3 pin plug top. Each 4.0 3234.17 12936.68 B 5.52 Supplying and erecting exhaust fan heavy duty 230 V A.C. 50 cycles 450 mm. 1400 RPM complete erected in position as per specification no. FG-FN/EXF Each 2.0 7057.65 14115.3 B 5.53 Supplying and erecting condenser 2.5 micro farad for ceiling fan Each 10.0 85.87 858.7 B 5.54 Providing & erecting epoxy outdoor / indoor end termination kit for LT XLPE armoured cable 70 to 120 sq mm., with necessary material as per specification No. CB-JT/LT Each 4.0 2941.45 11765.8 B 5.55 Supplying & erecting single compression type brass cable glands for 3½ core 120 sq mm for XLPE armoured cable as per specification No. CB-GL Each 10.0 454.03 4540.3 B 5.56 Supplying & erecting crimping type copper lugs for cable up to 16 sq mm complete as per specification No. CB-CL/CU Each 50.0 29.92 1496.0 B 5.57 Supplying & erecting crimping type aluminium lugs for cable up to 16 sq mm complete as per specification No. CB-CL/AL Each 50.0 13.02 651.0 B 5.58 Dismantling the existing cables of all types & size above 10 sq mm up to 50 sq.mm Mtr 160.0 29.92 4787.2 B 5.59 Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP Kg 20.0 288.82 5776.4 B 5.60 Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA- EP Kg 20.0 1148.74 22974.8 B 5.61 Supplying & erecting Float sensor switch for water level controller working on 250V & rated current 8A, with 2 mtr. wire & High quality of wire & plastic body. Each 1.0 588.03 588.03 B 5.62 Supplyinganderecting rigidsteelconduit16SWG25mmdia.withnecessary accessories inwall/floorwithchiselling appropriately asper specificationNo: WG-MA/CC. Mtr 50.0 312.23 15611.5 B 5.63 Supplying and erecting HMSPVCconduitFRLSgrade25mmdia.with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC. Mtr 50.0 165.22 8261.0 B 5.64 Supplying and erecting 25mm dia. corrugated flexible polypropylene conduit Mtr 50.0 27.32 1366.0 B 5.65 Supplying and erecting modular type switch 6A/10A duly erected on provided plate and box with wiring connections complete Each 50.0 93.67 4683.5 B 5.66 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background Each 20.0 287.51 5750.2 B 5.67 Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background Each 20.0 325.24 6504.8 B 5.68 Point wiring for light/fan/bell in 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm (2+1E) FRLSH grade copper wire with flush type switch and required accessories as per specification No: WG-PW/SW Point 6.0 642.68 3856.08 B 5.69 Supplying pedestal type air circulator 600 mm. sweep oscillating type suitable to work on 230 Volts 50 cycles 1440 RPM without speed regulator, metallic blades, overhead protection unit, totally enclosed, flame proof motor with additional 3 core wire, 5 meter length and hand shield type 3 pin6A. plug top complete with moisture proof treatment and ‘E’ class insulation Each 2.0 10855.13 21710.26 B 5.70 Installation, testing and commissioning of surface mounted 40Watt, LED Batten, with a system lumen output of 4400 lumens and a minimum system efficacy of 120 lumen/watt. The luminaire shall have a CRI of greater than 80 with rated system lifetime of 50,000 hours at L70. (Area having no False Ceiling, ASS Room, Corridor, Pump Room, Maintenance Room, Store Room etc). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BCLAB 40W LED) ,Note - LED Type to be Installed at Concourse and Platform Level Nos 200.0 158.59 31718.0 B 5.71 Installation, testing and commissioning of LED 2'x2' recessed fixture, (34 Watt to 40Watt) with a system lumen output of 3800 lumens at a system efficacy of 120 lumen/watt. (For false ceiling equipment room, Concoure). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BCLAB 40W LED). Note - LED Type to be Installed at Concourse and Platform Level Nos 50.0 237.89 11894.5 B 5.72 Installation, Testing & commissioning of highbay type 80 Watt LED Lighting Fixture. Fitting should have a aluminium pressure die cast housing with tempered glass for high transmittence. Luminaire should have system wattage of 80W with system efficacy of 120 lumens/W. It is designed to meet IP65 ensuring L70 for 50000 burning hours with PF of >0.95 with input voltage of 140-270V (for Street lighting). (80Watt LED Lighting Fixture similar to Bajaj Catalogue No. BGPPR 80W LED V2).Note - LED Type Lighting Fixture to be Installed at Roadl level (Carriage Way). Nos 50.0 317.18 15859.0 B 5.73 Installation, testing and commissioning of 18Watt, LED Downlighter with a system lumen output of 2000 lumens and a minimum system efficacy of 120 lm/W. The luminaire shall have a CRI greater than 80, lifetime of 50,000 hours at L70. Ingress Protection Classification of IP 20 (For Toilet). (18Watt LED Lighting Fixture similar to Bajaj Catalogue No. BZSLO 18W LED).Note - LED Type to be Installed at Concourse and Platform Level Nos 50.0 158.59 7929.5 B 5.74 Installation, testing and commissioning of LED surface mounted luminaire with a system lumen output of 4000 lumens and a minimum system efficacy of 120 lm/W. The Luminaire shall be IP65 rated and shall have a life of 50k hours at L70. .(For Platform and staircase). (40Watt LED Lighting Fixture similar to Bajaj Catalogue No. BI PC 40W LED XE)Note - LED Type to be Installed at Concourse and Platform Level Nos 200.0 317.18 63436.0 B 5.75 Repair work of Illuminated Station Name Signage Board (LED) installed at fadade of Stations (Driver/LED replacement, wiring issue or any other fault to restore the signage board) excluding spares required for repair & manlifter/boom lifter. Nos 50.0 779.98 38999.0 B 5.76 Repair work of Illuminated Signage Board (LED) in side Stations (Driver/LED replacement, wiring issue or any other fault to restore the signage board) excluding spares required for repair. Nos 100.0 259.6 25960.0 A.5 & B.5 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR LT PANEL (EXCLUSIVE OF GST) 2888342.29 A.6 PREVENTIVE AND CORRECTIVE MAINTENECE OF Rolling Shutter A.6.1 YEARLY Maintenance of Rolling shutter including Oiling and greasing of rolling shutters with H.P. equipment greasing including complete cleaning of oil and scrapping of grease including labours andmaterials, Motor operation, Replacement of minor itesm if any etc. Work during night time as per direction of Engineer in charge. For all shutters loacted at RSS etc. Service 5.0 315.0 1575.0 A.6.2 Repairing and Corrective Maintenance of existing rolling shutters including dismantling the shutter and refixing the same and fixing of new items as per requiremnt including cleaning, oiling, greasing, alignment and testing complete. The cost of new items (including electrical parts such asswitches, relay, button, wires) will be paid separately except small hardware like nuts/bolts and nails which are included in this item. Service 3.0 7350.0 22050.0 A.6 Total Cost for Maintenance and Material Supply for Rolling Sutter (Exclusive GST) 23625.0 A. 7 Poviding Man Lifter/Boom Lifter As Per Requirement A. 7.1 Towable Boom/Man Lifter weight carrying capacity approx. 200Kg at working height of range 3.5-14m. (1 Machine) including driver/operator. This also includes administrative Charges,Machine Fuel,Maintenance,Inclusive of all charges for Machine. As & when required Days 24.0 7080.0 169920.0 A. 7.2 Towable Boom/Man Lifter weight carrying capacity approx. 200Kg at working height of range 15-25m. (1 Machine) including driver/operator. This also includes administrative Charges,Machine Fuel,Maintenance,Inclusive of all charges for Machine. As & when required Days 2.0 33849.42 67698.84 A. 7.2 Hire charges of TATA 407 or equivalent for local shifting. Days 20.0 1966.18 39323.6 TOTAL COST FOR MAINTENECE AND MATERIAL SUPPLY FOR BOOM LIFTER (EXCLUSIVE OF GST) 276942.44 A. 8 Corrective Maintenanace of Emergency Buzzer in Divyaganjan Toilets at Stations of Navi Mumabi Metro Line-1 A. 8.1 Repair/rectification of calling unit with pulling cord along with door unit and audible indication having power supply provision issue Nos 24.0 4248.0 101952.0 A. 8.2 Supply of Emergecy Push Button/cord along with door unit Nos 8.0 16284.0 130272.0 A. 8.3 Supply of audible unit for emergency buzzer Nos 8.0 12508.0 100064.0 A. 8.4 Supply of Control Cable connectivity (2 pair x 1 sq mm Cu Cable of calling unit and door unit Nos 100.0 141.6 14160.0 Total Corrective Maintenanace of Emergency Buzzer in Divyaganjan Toilets at Stations of Navi Mumabi Metro Line-1 346448.0 Total Cost of Schedule 01 8347226.56 Schedule-2 : Certification of Fire NOC & Form B, LUMPSUM Items Description Unit Quantity Section 2.1 FIRE NOC & FORM B 2.1.1 \\"Certification of Form - B (HALF YEARLY) from licenced agency of Maharashtra Fire Services for PMRP Metro Stations under jurisdict ion of Pune Municipal Corporation and Pimpri Chinchwad Municipal Corporationas per the prescribed schedule regarding Fires Sytems in stalled at PMRP stations, depots and Office. This also includes the contractor for Licence work such as filling necessary applicatio ns, submission of forms for approval to the local authorities, depositing fees and other amounts.For 11 Nos of Elevated Stations, One Depot, 2 Nos of RSS, TOTAL-14 Nos Per Schedule 28.0 6544.29 183240.12 2.1.2 Service Charges towards Lisoning fees for Obtaining Fire NOC from Fire Department (To be paid on actual Challan in Muncipalties) Nos 1.0 6544.29 6544.29 Section 2.2 INCIDENTAL/EMERGENCY WORKS/SPARES FOR E&M SYSTEMS MAINTENANCE SN Emergency/Incidental Works Unit Quantity 2.2.1 Supply od Spares for LT Panels 2.2.1.1 ACB 1000A FP 50KA MDO TYPE-DMX3 ACB Nos 1.0 205653.18 205653.18 2.2.1.2 ACB CABLE INTERLOCK TYPE 1 (2600 MM) Nos 1.0 12182.04 12182.04 2.2.1.3 ACB CABLE INTERLOCK TYPE 3 (3600 MM) Nos 1.0 12182.04 12182.04 2.2.1.4 ACB CLOSING COIL 230V AC/DC Nos 1.0 8079.9 8079.9 2.2.1.5 ACB COMMUNICATION MODULE Nos 1.0 2929.86 2929.86 2.2.1.6 ACB EXTERNAL POWER SUPPLY MODULE 12V DC Nos 1.0 6080.0 6080.0 2.2.1.7 ACB INTERLOCK PLATE FOR DMX3 (UPTO 2500A) Nos 1.0 21489.28 21489.28 2.2.1.8 ACB MP4 LSIG RELEASE Nos 1.0 41153.3 41153.3 2.2.1.9 ACB REAR TERMINAL FP DRAW-OUT FOR 2500A FRAME-1 Nos 1.0 14224.4 14224.4 2.2.1.10 ACB SHUNT TRIP 230V AC/DC Nos 1.0 7633.04 7633.04 2.2.1.11 ACB SPRING CHARGING MOTOR 230VAC Nos 1.0 37159.75 37159.75 2.2.1.12 ACB UNDER VOLTAGE RELEASE 230V AC/DC Nos 1.0 12175.74 12175.74 2.2.1.13 AMMETER 1PH DIGITAL CL-1, CTR-1/5A, AUX SUPPLY 80-300V AC Nos 2.0 1375.24 2750.48 2.2.1.14 AMMETER 30A DC 96SQMM Nos 2.0 1699.38 3398.76 2.2.1.15 AMMETER THREE PHASE DIGITAL CL-1.0 Nos 2.0 2073.85 4147.7 2.2.1.16 ANNUNCIATOR 8 W 12V DC WITH PUSH BUTTON W/O BUZZER (1D) Nos 2.0 22005.38 44010.76 2.2.1.17 ATS 250A FP 230 SERIES WITH CONTROLLER IN OPEN FRAME Nos 1.0 170022.87 170022.87 2.2.1.18 ATS 630A FP 230 SERIES WITH C1000 CONTROLLER IN OPEN FRAME Nos 1.0 303084.24 303084.24 2.2.1.19 AUTOMATIC BATTERY CHARGER 20A 230/12VDC Nos 2.0 25490.68 50981.36 2.2.1.20 AUX CONT BLOCK 1NO+1NC FRONT MOUNTING {FOR PWR CONTACTOR} Nos 2.0 497.23 994.46 2.2.1.21 AUX CONT BLOCK 2NO+2NC FRONT MOUNTING {FOR AUX CONTACTOR} Nos 2.0 739.54 1479.08 2.2.1.22 AUX CONTACTOR 2NO+2NC AUX 230VAC Nos 2.0 1727.71 3455.42 2.2.1.23 AUX RELAY BASE 8 PIN FOR 2C/O Nos 2.0 637.27 1274.54 2.2.1.24 AUX RELAY WITH LED 2C/O 12V DC Nos 2.0 637.27 1274.54 2.2.1.25 BREAKER CONTROL SWITCH T-N-C 25A Nos 2.0 2402.73 4805.46 2.2.1.26 BUZZER 12-220V AC/DC Nos 2.0 2039.25 4078.5 2.2.1.27 CT 100/5A 10VA CL-1.0 RING TYPE CAST RESIN ID-30MM Nos 2.0 1699.38 3398.76 2.2.1.28 CT 150/5A 10VA CL-1.0 RING TYPE CAST RESIN ID-30MM Nos 2.0 1359.5 2719.0 2.2.1.29 CT 20/5A 5VA CL-1.0 WPL TYPE CAST RESIN Nos 2.0 1869.32 3738.64 2.2.1.30 CT 200/5A 10VA CL-1.0 RING TYPE CAST RESIN ID-30MM Nos 2.0 1189.55 2379.1 2.2.1.31 CT 250/5A 10VA CL-1.0 RING TYPE CAST RESIN ID-45MM Nos 2.0 1274.54 2549.08 2.2.1.32 CT 30/5A 5VA CL-1.0 WPL TYPE CAST RESIN Nos 2.0 1359.5 2719.0 2.2.1.33 CT 40/5A 5VA CL-1.0 WPL TYPE CAST RESIN Nos 2.0 1359.5 2719.0 2.2.1.34 CT 60/5A 5VA CL-1.0 WPL TYPE CAST RESIN Nos 2.0 1359.5 2719.0 2.2.1.35 CT 600/5A 10VA CL-1.0 RING TYPE CAST RESIN ID-55MM Nos 2.0 1274.54 2549.08 2.2.1.36 CT 80/5A 10VA CL-1.0 WPL TYPE CAST RESIN Nos 2.0 1359.5 2719.0 2.2.1.37 CT 800/5A 15VA CL-1.0 RECTANGULAR TYPE CAST RESIN ID:130X25MM Nos 2.0 1444.47 2888.94 2.2.1.38 DC AMMETER SHUNT 30A Nos 2.0 1699.38 3398.76 2.2.1.39 ENERGY METER CL-1.0,CTR-/5A AUX 80-300V AC/DC WITH RS485 PORT Nos 2.0 4698.48 9396.96 2.2.1.40 ENGINE STARTING RELAY 12VDC Nos 2.0 5947.85 11895.7 2.2.1.41 LED INDICATOR AMBER 240VAC 22.5MM GEN NEXT PRO TYPE Nos 20.0 215.6 4312.0 2.2.1.42 LED INDICATOR BLUE 240VAC 22.5MM GEN NEXT PRO TYPE Nos 20.0 372.92 7458.4 2.2.1.43 LED INDICATOR GREEN 240VAC 22.5MM GEN NEXT PRO TYPE Nos 20.0 215.57 4311.4 2.2.1.44 LED INDICATOR RED 12VAC/DC 22.5MM GEN NEXT PRO TYPE Nos 20.0 215.57 4311.4 2.2.1.45 LED INDICATOR RED 240VAC 22.5MM GEN NEXT PRO TYPE Nos 20.0 215.57 4311.4 2.2.1.46 LED INDICATOR YELLOW 240VAC 22.5MM GEN NEXT PRO TYPE Nos 20.0 215.57 4311.4 2.2.1.47 LED LIGHT 5W 230VAC Nos 20.0 1062.11 21242.2 2.2.1.48 LIMIT SWITCHE WITH PUSH ROAD & PLASTIC PROTECTIVE COVER 10A/500V 1NO+1NC Nos 20.0 849.7 16994.0 2.2.1.49 MCB 10A DP C-CURVE 10KA DX3 Nos 2.0 972.43 1944.86 2.2.1.50 MCB 10A SP C-CURVE 10KA DX3 Nos 2.0 302.12 604.24 2.2.1.51 MCB 16A DP C-CURVE 10KA DX3 Nos 2.0 972.43 1944.86 2.2.1.52 MCB 16A DP D-CURVE 10KA DX3 Nos 2.0 996.03 1992.06 2.2.1.53 MCB 20A DP C-CURVE 10KA DX3 Nos 2.0 972.43 1944.86 2.2.1.54 MCB 32A DP C-CURVE 10KA DX3 Nos 2.0 972.43 1944.86 2.2.1.55 MCB 32A FP C-CURVE 10KA DX3 Nos 2.0 2119.5 4239.0 2.2.1.56 MCB 32A FP D-CURVE 10KA DX3 Nos 2.0 2125.79 4251.58 2.2.1.57 MCB 40A FP C-CURVE 10KA DX3 Nos 2.0 3016.4 6032.8 2.2.1.58 MCB 63A FP C-CURVE 10KA DX3 Nos 2.0 3016.4 6032.8 2.2.1.59 MCB 6A DP C-CURVE 10KA DX3 Nos 2.0 972.43 1944.86 2.2.1.60 MCB 6A SP C-CURVE 10KA DX3 Nos 2.0 302.12 604.24 2.2.1.61 MCCB 100A FP 25KA DPX3-250 MP BASED O/C S/C E/F REL. Nos 1.0 44367.95 44367.95 2.2.1.62 MCCB 100A TP 25KA DPX3-160 TM O/CS/C REL. Nos 2.0 7914.7 15829.4 2.2.1.63 MCCB 125A FP 25KA DPX3-160 TM O/CS/C REL. Nos 1.0 13897.14 13897.14 2.2.1.64 MCCB 160A FP 25KA DPX3-160 TM O/CS/C REL. Nos 1.0 17695.56 17695.56 2.2.1.65 MCCB 160A FP 25KA DPX3-250 MP BASED O/CS/CE/F REL. Nos 1.0 48894.9 48894.9 2.2.1.66 MCCB 160A TP 50KA DPX3-160 TM O/CS/C REL Nos 1.0 19706.5 19706.5 2.2.1.67 MCCB 200A FP 25KA DPX3-250 TM O/CS/C REL Nos 1.0 24966.71 24966.71 2.2.1.68 MCCB 250A FP 25KA DPX3-250 MP BASED O/CS/CE/F REL. Nos 1.0 57048.78 57048.78 2.2.1.69 MCCB 250A FP 36KA DPX3-250 MP BASED O/CS/CE/F REL. Nos 1.0 50411.76 50411.76 2.2.1.70 MCCB 40A TP 50KA DPX3-160 THERMAL MAG O/C,S/C REL Nos 1.0 13362.15 13362.15 2.2.1.71 MCCB 630A FP 36KA DPX3-630 MP BASED O/C S/C E/F REL. Nos 1.0 72464.34 72464.34 2.2.1.72 MCCB 63A FP 25KA DPX3-160 THERMAL MAG O/C,S/C REL Nos 1.0 11003.48 11003.48 2.2.1.73 MCCB 80A FP 25KA DPX3-160 THERMAL MAG. O/CS/C REL. Nos 1.0 11003.48 11003.48 2.2.1.74 MCCB AUX/FAULT 1C/O CONTACT BLOCK FOR DPX3-160/1600A Nos 2.0 1136.07 2272.14 2.2.1.75 MCCB EXTENDED DOOR OPERATING HANDLE FOR DPX-H 630 Nos 2.0 3675.7 7351.4 2.2.1.76 MCCB LOCK AND FLAT KEY DPX3 630 Nos 2.0 8224.67 16449.34 2.2.1.77 MCCB MOTOR MECHANISM 230VAC DPX 630 Nos 1.0 51960.1 51960.1 2.2.1.78 MCCB MOTOR OPERATOR 24-230VAC/DC FOR DPX3 Nos 1.0 32067.92 32067.92 2.2.1.79 MCCB PHASE BARRIER FOR DPX3-400,630 Nos 2.0 213.99 427.98 2.2.1.80 MCCB PHASE BARRIERS FOR TP/FP DPX3-160/DPX3-250 Nos 2.0 182.53 365.06 2.2.1.81 MCCB RONIS KEY BARREL FOR FRONT MOTOR OPERATOR DPX3 160 & 250 Nos 1.0 7326.21 7326.21 2.2.1.82 MCCB ROTARY HANDLE FOR DPX3-160/250 Nos 6.0 1935.4 11612.4 2.2.1.83 MCCB SPREADERS LINK FOR FP DPX³ 250/DRX-250HP Nos 2.0 956.69 1913.38 2.2.1.84 MCCB SPREADERS LINK FOR FP DPX3-160 Nos 2.0 956.69 1913.38 2.2.1.85 MCCB SPREADERS LINK FOR TP DPX3-160 Nos 2.0 717.51 1435.02 2.2.1.86 MCCB UNDER VOLTAGE RELEASE 200-240V AC DPX3 160/250 Nos 2.0 3131.26 6262.52 2.2.1.87 MCCB UNDER VOLTAGE RELEASE 230V AC DPX3 630/1600 Nos 2.0 3752.8 7505.6 2.2.1.88 MULTIFUNCTION LED METER 3PH AUX. 80-300V AC/DC CL-1 WITH RS-485 PORT Nos 2.0 13628.08 27256.16 2.2.1.89 OVER LOAD RELAY 54-75A THERMAL RTX³-100 Nos 2.0 6372.67 12745.34 2.2.1.90 OVER LOAD RELAY 7-10A THERMAL RTX³ 40 Nos 2.0 2020.37 4040.74 2.2.1.91 OVER LOAD RELAY 9-13A THERMAL RTX³ 40 Nos 2.0 2020.37 4040.74 2.2.1.92 OVER LOAD RELAY MOUNTING UNIT FOR RTX³ 100 Nos 2.0 1189.6 2379.2 2.2.1.93 OVER LOAD RELAY MOUNTING UNIT FOR RTX³ 40 Nos 2.0 758.42 1516.84 2.2.1.94 POWER SUPPLY MODULE I/P 100-240VAC O/P 24VDC, 92W Nos 2.0 1054.25 2108.5 2.2.1.95 PUSH BUTTON BLACK FLUSH HEAD TYPE Nos 20.0 207.7 4154.0 2.2.1.96 PUSH BUTTON ELEMENT NC Nos 20.0 155.78 3115.6 2.2.1.97 PUSH BUTTON ELEMENT NO Nos 20.0 155.78 3115.6 2.2.1.98 PUSH BUTTON GREEN Nos 20.0 207.7 4154.0 2.2.1.99 PUSH BUTTON MUSHROOM HEAD RED PUSH TRUN TYPE Nos 10.0 387.08 3870.8 2.2.1.100 PUSH BUTTON MUSHROOM HEAD RED WITH LOCK & KEY Nos 5.0 748.98 3744.9 2.2.1.101 PUSH BUTTON RED Nos 20.0 207.7 4154.0 2.2.1.102 PWR CONTACTOR 100A TP AC3 (2NO+2NC) 230V AC Nos 1.0 20005.46 20005.46 2.2.1.103 PWR CONTACTOR 130A TP AC3 (2NO+2NC) 230V AC CTX3-150 Nos 1.0 29750.15 29750.15 2.2.1.104 PWR CONTACTOR 22A(1NO+1NC) TP AC3 DUTY 230V AC Nos 2.0 2471.96 4943.92 2.2.1.105 PWR CONTACTOR 32A TP AC3 (2NO+2NC) DUTY 230V AC Nos 1.0 5183.1 5183.1 2.2.1.106 PWR CONTACTOR 40A TP AC3 (2NO+2NC) 230V AC Nos 1.0 7677.1 7677.1 2.2.1.107 RCBO 32A FP 30MA DX3 Nos 1.0 5757.43 5757.43 2.2.1.108 RCBO 40A DP 30MA DX3 Nos 2.0 5061.95 10123.9 2.2.1.109 RCBO 40A FP 30MA DX3 Nos 2.0 5736.97 11473.94 2.2.1.110 RELAY CRANKING 2C/O 12VDC Nos 2.0 1169.11 2338.22 2.2.1.111 RELAY UNDER & OVER VOLTAGE 3PH 3W/4W SYSTEM VOLTAGE 380-440V AC 2C/O Nos 1.0 5017.89 5017.89 2.2.1.112 SELECTOR SWITCH 2P 2W OFF 16A Nos 2.0 813.5 1627.0 2.2.1.113 SELECTOR SWITCH 2P 2W OFF 6A Nos 2.0 429.57 859.14 2.2.1.114 SELECTOR SWITCH 2P 3W WITH OFF 6A Nos 2.0 528.7 1057.4 2.2.1.115 SPACE HEATER 100W 230/240VAC Nos 4.0 2549.07 10196.28 2.2.1.116 THERMOSTAT 35-75.C 240V AC Nos 4.0 1062.11 4248.44 2.2.1.117 TIMER ON DELAY MICON 175 0.3SEC-30 HRS 12V DC 1 C/O Nos 4.0 1622.28 6489.12 2.2.1.118 TIMER ON DELAY MICON 225 24-240V AC/DC 0.1-10 HRS. 2C/O Nos 2.0 2311.47 4622.94 2.2.1.119 TIMER STAR DELTA Micon 175 SER. 240VAC Nos 2.0 1444.47 2888.94 2.2.1.120 TOGGLE SWITCHES SP OFF-ON 10A/250V AC Nos 2.0 849.68 1699.36 2.2.1.121 VOLTMETER 0-50V DC 96SQMM Nos 2.0 1699.38 3398.76 2.2.1.122 VOLTMETER THREE PHASE DIGITAL CL-1.0 Nos 2.0 2073.87 4147.74 2.2.123 Supply of High mast timer for automation of lighting GIC make FM1/ Quartz Daily 240VAC Base Nos 10.0 1040.0 10400.0 2.2.124 Supply, Installation, Testing and commissioning of 12 V/180Ah SMF-(VRLA) battery with battery terminal wire, duly charged complete with 36 months warranty complete ( For DG & Diesel Pump) Nos 2.0 23550.99 47101.98 2.2.127 Supply of Oil CI4 PLUS 15W 40 industrial grade oil for diesel generator Litre 200.0 205.0 41000.0 Section 2.3 Annual Maintenace Contract of EOT crane Make : Electromech, Model : SG EOT, Capacity : 5T, Span : 11.9 Mtrs, Sr.No.: 5675, Cls.Duty : M5 in RSS (Panchanand) Nos 1.0 283200.0 283200.0 Section 2.4 Manpower for Non-Schedule works E.11 Semi skilled woker (As when required). Man/day 50.0 779.98 38999.0 E.12 Unskilled workers (As when required). Man/day 50.0 733.96 36698.0 TOTAL COST OF SCHEDULE-2 (in INR) 2553824.58 Schedule-3 : UPS Maintainance Section 3.1 Preventive & Corrective maintinance of UPS Unit Quantity Total 4 Preventive Maintenece Service Visits in a 1 Year covering unlimited breakdown calls/Corrective Maintainance covering following scope of work : Checking of all parameters and alarms and warnings, Individual battery voltage check, Servo Voltage Control Stabilizer (SVCS), Cleaning UPS & electronics cards, Fan check, UPS overall operation check (Loading, Synchronization, Bypass), Connection checking & tightening, Mechanical Check & software upgrade. 3.1.1 60 KVA, Vertiv make Nos 2.0 21948.0 43896.0 3.1.2 60 KVA, Numeric make Nos 8.0 21948.0 175584.0 3.1.3 60 KVA , Schinder make Nos 4.0 21948.0 87792.0 3.1.4 40 KVA , Schinder make Nos 8.0 14632.0 117056.0 3.1.5 100 KVA, Reillo make Nos 2.0 36580.0 73160.0 3.1.6 150/160 KVA, Reillo make Nos 2.0 54870.0 109740.0 3.2 INCIDENTAL/EMERGENCY SPARES SUPPLY FOR UPS MAINTENANCE SN Description Unit Quantity 1.0 Fuse, Semiconductor, Ceramic, 200 Amp, 500 Vac/dc, Fast, 50 kA, 8500 Amp Sq Sec, Centre Bolted Blade, 29.4 X 92.1 mm, RoHS Nos 2.0 5074.0 10148.0 2.0 Capacitor, Metallized Polypropylene Film, Panel Mounted, Stud terminal, 100 uF, 250 Vac, +/-5%, -40 to 70 Deg C, 35 mm, D63.5 X 107 mm, RoHS Nos 2.0 5000.84 10001.68 3.0 Capacitor, Aluminum Electrolytic, Panel Mounted, Screw Lead, 4700 uF, 450 Vdc, +/-20%, -40 to 85 Deg C, 31.6 mm, D76 X 145 mm, RoHS Nos 2.0 18719.52 37439.04 4.0 Fan, Axial, 230 Vac, 45 W, 194 CFM, 2800 RPM, 172 X 150 X 55 mm, IP20 Nos 2.0 14919.92 29839.84 5.0 Fan, Axial, 230 Vac, 64 W, 520 CFM, 2550 RPM, 260 X 225 X 80 mm, IP44 Nos 2.0 27772.48 55544.96 6.0 Capacitor, Metallized Polypropylene Film, Panel Mounted, Double Fast on, 30 uF, 450 Vac, +/-5%,-25 to 70 Deg C, D45 X 132 mm Nos 2.0 1633.12 3266.24 7.0 Fuse, Semiconductor, Ceramic, 250 Amp, 700 Vac/dc, Fast, 10 kA, 42500 Amp Sq Sec, Centre Bolted Blade, 50.8 X 129.3 mm, RoHS Nos 2.0 8484.2 16968.4 8.0 IGBT, Heatsink Mounted, Dual Module, 300 Amp, 1200 V, 1.85 V, 2.5 Ohm, 106.4 X 61.4 X 30.5 mm, RoHS Nos 2.0 35185.24 70370.48 9.0 Hall Effect Sensor, 200 Amp, +/- 600 Amp, Output Voltage - 4 V, Open Loop, Supply voltage - 15 V, Panel Mounting Nos 2.0 5944.84 11889.68 10.0 Thyristor, Heat Sink Mounted, Module, 190 Amp Average, 300 Amp RMS, 1600 V Nos 2.0 15835.6 31671.2 11.0 Hall Effect Sensor, 200 Amp, +/- 600 Amp, Output Voltage - 4 V, Open Loop, Supply voltage - 15 V, Panel Mounting Nos 2.0 5944.84 11889.68 12.0 IGBT, Heatsink Mounted, Dual Module, 300 Amp, 1200 V, 1.85 V, 2.5 Ohm, 106.4 X 61.4 X 30.5 mm, RoHS Nos 2.0 17586.72 35173.44 13.0 PCA - DC-DC Converter Card, 360 V Transformerless UPS, 1130DB-1/11 Nos 2.0 19765.0 39530.0 14.0 PCA - Snubber Card, 856DB-1 Nos 2.0 1958.8 3917.6 15.0 PCA - MOV Card for 3 Phase, 933DB-1/2 Nos 1.0 29252.2 29252.2 16.0 PCA - AC Static Switch Interface Card, 1347DB-1 Nos 2.0 8871.24 17742.48 17.0 PCA - Mun Card, 15B10895G1, 80 Net UPS Nos 2.0 75343.0 150686.0 18.0 PCA - CIB Card, 710-02375, 80 Net UPS Nos 1.0 123121.2 123121.2 19.0 PCA - Conditioning Board, 15B10893G1, 80 Net UPS Nos 2.0 53454.0 106908.0 20.0 PCA - DIC Board, 710-02821, 80 Net UPS Nos 1.0 114070.6 114070.6 21.0 PCA - SMPS Card, 15B10952G2 Nos 1.0 176343.92 176343.92 22.0 PCA - Static Switch Control Card, 1 Phase for Transformerless UPS, 1078DB-3/1 Nos 2.0 6962.0 13924.0 23.0 PCA - SMPS Interface Card, 1307DB-1 Nos 2.0 20005.72 40011.44 24.0 PCA - IGBT Driver Card, 15B10932G1 Nos 2.0 34692.0 69384.0 Sub Total Total 1209094.08 TOTAL COST OF SCHEDULE-3 (in INR) 1816322.08 SCHEDULE-4 (in INR) 1.0 Breakdown in any equipment which is not covered above if any (Charges for incidental & urforseen items). Payment will be made as per actual expenditure if required. Lump-sum 1.0 1770000.0 1770000.0 TOTAL COST OF SCHEDULE-4 (in INR) 1770000.0 Sub Total (Schedule 1, 2 & 3) 14487373.22 Part B: Schedule 1: Preventive Maintenance for OHE for 1 Year Part (I) - Preventive Maintenance for Over Head Equipment (OHE) of NMM SN Description of Work Unit ofMeasurement Total Qty of Assets Rate in INR(incl GST) Amount in INR (incl. GST) 1.1 Maintenance of Cantilever assembly, OHE Structure, TTU, DA and allied OHE SPS and structures. Nos. 2312.0 677.71 1566865.52 1.2 Maintenance of Catenary system (Contact wire, catenary wire, droppers, OPC, BEC, 1.1 KV RC, Current Collection Test) Per TKM 122.0 4066.28 496086.16 1.3 Maintenance of all type of 25 KV OHE Jumpers Nos. 161.0 655.76 105577.36 1.4 Maintenance of Anti Creep Centre (ACC), Anti Creep Anchor (ACA) and Fix Termination Anchor (FTA arrangement) Nos. 89.0 1639.4 145906.6 1.5 Maintenance of depot and Mainline Isolators, Interrupter, Voltage transformer No. 84.0 1639.4 137709.6 1.6 Maintenance of Overlaps (insulated and uninsulated} No. 26.0 1639.4 42624.4 1.7 Maintenance of Cross over & Turnouts Nos. 40.0 4066.28 162651.2 1.8 Maintenance of all type Section Insulator Assembly & Neutral Section assembly Nos. 42.0 4066.28 170783.76 1.9 Maintenance of BWA type Auto tension Device (ATD) Nos. 84.0 2033.12 170782.08 1.1 Maintenance of ITL Nos. 22.0 546.46 12022.12 1.11 Maintenance of Earthing System with its whitewash/painting, grass cutting (as required), tree trimming (as required) & value writing in depot (YRLY) Nos. 51.0 498.27 25411.77 1.12 Reconditioning of Earth pit with materials & when required Nos. 51.0 1626.51 82952.01 1.13 Current Collection Test Per TKM 22.4 1062.6 23802.24 Part (II) - Breakdown Maintenance & other for Over Head Equipment of NMM 3.1 Breakdown attention by a gang for restoration of 25 KV OHE/PSI during accidents/unusual occurrence for checking OHE parameters. Breakdown attention gang shall be a part of CM/PM maintenance team. Nos. 3.0 17582.35 52747.05 3.2 Panto entanglement due to OHE component like Turn out, Overlap, non OHE zone, Jumper, Dropper, Cantilever steady arm & other component of Cantilever, Section insulator, Neutral Section, Foreign Material etc. Nos. 4.0 12857.45 51429.8 3.3 Erection of Catenary wire splicing or Contact wire splicing Nos. 4.0 17582.35 70329.4 3.4 Replacement / Re-erection of various types of insulators Nos. 6.0 6428.72 38572.32 3.5 Splicing of OPC Nos. 4.0 4853.75 19415.0 3.6 Replacement/ Re-erection of Section Insulator I(double rod type), Neutral Section assembly Nos. 2.0 25975.88 51951.76 3.7 Replacement / Re-erection BWT types of ATD, Interrupter/BM, VT, Isolator 'including loading & unloading' Nos. 4.0 80396.56 321586.24 3.8 Replacement/ Re-erection of Single/Double/Tripple bracketassembly Cantilever Nos. 4.0 6555.55 26222.2 3.9 CAD Weld from ITL to Rail. Nos. 10.0 8251.49 82514.9 3.1 Stencilling of OHE structure with materias Nos. 100.0 448.4 44840.0 3.11 Repair of discharge rod without material Nos. 100.0 109.74 10974.0 3.12 Supply & Erection of all types of boards Nos. 10.0 1475.0 14750.0 3.13 Rectification of leaning mast with material Nos. 1.0 10938.6 10938.6 3.14 Replacement of OHE light sensor aviator light/bulb indicator Red/Green Nos. 6.0 1475.0 8850.0 Total of Schedule (1) 3948296.09 Part B : Schedule 2: Miscellaneous & consumable items including small tools etc. for OHE SN Description of Work Unit ofMeasurement Total Qty. of Assets 1.1 Miscellaneous & consumable items including small tools, testing of equipment etc. and payment shall be made as per actual expenditure Lump Sum 1.0 236000.0 236000.0 Total of Schedule (2) 236000.0 Grand Total (Schedule 1 + Schedule 2) 4184296.09 Part B : Schedule 3: Part -I - Preventive Maintenance for Power Supply (RSS. ASS & Switching Post) SN Description of Work Unit of Measurement Total Qty. of Assets Rate in INR(incl GST) Amount in INR (incl. GST) A Preventive Maintenance activities for RSS Equipments 1.1 Preventive Maintenance of 25MVA, 220/33 KV Transformers Nos 2.0 318600.0 637200.0 1.2 Transformer oil filtration- 25 MVA transformer Per ltr 47200.0 3.54 167088.0 1.3 Preventive Maintenance of 10MVA, 33/27.5 KV Transformers Nos 4.0 265500.0 1062000.0 1.4 Transformer oil filtration- 10 MVA transformer Per ltr 24000.0 3.54 84960.0 1.5 Maintenance of 220 KV GIS for 2 Bay out of 5 Nos 2.0 2006000.0 4012000.0 1.6 Maintenance of 33 KV GIS Verticals 25.0 33040.0 826000.0 1.7 Maintenance of 25 KV GIS Verticals 12.0 33040.0 396480.0 1.8 Maintenance of 33kV/415V Dry Type Transformer Nos. 2.0 4982.6 9965.2 1.9 Maintenance of ACDB Nos. 2.0 2491.28 4982.56 1.1 Maintenance of DCDB Nos. 2.0 2491.28 4982.56 1.11 Maintenance of Battery Charger Nos. 2.0 2491.28 4982.56 1.12 Maintenance of Battery Bank Nos. 4.0 4982.6 19930.4 1.13 Maintenance of Earthing System with its whitewash/paintinG & value writina Nos. 35.0 498.25 17438.75 1.14 Maintenance of Burried Rail Nos. 2.0 4982.6 9965.2 1.15 UPS ( 6KVA ) Nos 4.0 2832.0 11328.0 1.16 UPS ( 5 KVA ) Nos 1.0 2360.0 2360.0 1.17 RTU Nos 13.0 1711.0 22243.0 Preventive Maintenance activities for ASS Equipments 2.1 Maintenance of 33 KV RMU Nos. 27.0 30680.0 828360.0 2.2 Maintenance of Dry type Transformer Nos. 26.0 3278.75 85247.5 2.3 Maintenance of Battery Charger Nos. 13.0 1660.84 21590.92 2.4 Maintenance of Battery Bank Nos. 13.0 1660.84 21590.92 2.5 Maintenance of ACDB Nos. 13.0 1245.64 16193.32 2.6 Maintenance of DCDB Nos. 13.0 1245.64 16193.32 2.7 Maintenance of IGBT Nos 12.0 1793.6 21523.2 2.8 Transportation charge including driver and all fuel charges, 24x7 monthly services up to 2,000 KMs per month (Camper Yoddha), including all maintenance charges. Any additional kilometers beyond 2,000 KMs shall be charged on a pro-rata basis. month 12.0 107022.0 1284264.0 Switching Post & Viaduct Light 3.1 Viaduct Lighting and Power sockets as & when required Nos 1800.0 498.27 896886.0 Part B : Schedule 3: Part- Il - Breakdown Maintenance activities 4.1 33kV and 25kV cable end termination jointing work (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) Nos 6.0 3597.0 21582.0 4.2 33kV and 25kVcable straight through joint on site (Jointing kit will be provided by Maha-Metro & Contractor has to provide certified jointer by OEM) Nos 6.0 3597.0 21582.0 4.3 Breakdown maintenance for 220 KV GIS By OEM Man -days 5.0 169920.0 849600.0 4.4 Breakdown maintenance for 33 KV GIS by OEM Man -days 5.0 44840.0 224200.0 4.5 Breakdown maintenance for 25 kv GIS by OEM Man -days 5.0 44840.0 224200.0 4.6 Breakdown maintenance for 33 KV RMU by OEM Man -days 5.0 42480.0 212400.0 4.7 Breakdown Maintenance for 25MVA Auxiliarry trafo by OEM Man -days 5.0 70800.0 354000.0 4.8 Breakdown Maintenance for 25MVA Auxiliarry trafo NIFPS by OEM Man -days 5.0 38350.0 191750.0 4.9 Breakdown Maintenance for 10MVA Traction Trafo Man -days 5.0 70800.0 354000.0 4..10 Breakdown Maintenance for 10MVA Traction Trafo NIFPS Man -days 5.0 38350.0 191750.0 4.11 Breakdown Maintenance of 220/33/25 KV CRP/SAS by OEM Mandays 40.0 59472.0 2378880.0 4.12 Breakdown Maintenance of OCC SCADA/RTU by OEM Mandays 20.0 49560.0 991200.0 4.13 Breakdown Maintenance of IGBT by OEM Perday 3.0 17700.0 53100.0 4.14 Replacement & Laying of 33&25kV Cable on Viaduct mtr 20.0 177.0 3540.0 4.15 Replacement & Laying of 33&25kV Cable in ground mtr 20.0 708.0 14160.0 4.16 Laying of Control & LT Cable upto 70 Sq.mm. mtr 300.0 54.28 16284.0 4.17 Hire charge of diesdel Truck-9Tonne for shifting of matrial form store to site( As & when required ) Perday 2.0 5192.0 10384.0 4.18 SF6 Gas multi analyser Perday 1.0 56404.0 56404.0 4.19 Breakdowan maintenance of 33KV DTT (ABB) Perday 2.0 29500.0 59000.0 4..20 Semi skilled worker ( as when required) man/day 35.0 779.95 27298.25 4.21 Supply of 245kV CGL make condenser bushing nos 1.0 1486800.0 1486800.0 4.22 Supply of 36kV porcelain bushing with metal part assembly nos 1.0 318600.0 318600.0 4.23 Supply of 52kV CGL make condenser bushing nos 1.0 791308.0 791308.0 4.24 Supply of 36kV porcelain bushing with metal part assembly nos 1.0 318600.0 318600.0 Total of Schedule 3 19656377.66 Part B : Schedule 4: Miscellaneous & consumable items including small tools etc. for PSI SN Description of Work Unit of Measurement Total Qty. of Assets Rate in INR(incl GST) Amount in INR (incl. GST) 1.1 Provisional Sums: Miscellaneous & consumable items and payment shall be made as per actual expenditure Lump Sump 1.0 1770000.0 1770000.0 Total of Schedule 4 Grand Total (Schedule 3 + Schedule 4) 21426377.66 Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |