| 1 | WORK NAME |
| 2 | Providing & Fixing of IK08 IP65 protected Top/Bottom mounted LEDPost top Luminarie made of single piece construction powdercoated die cast alluminium housing with UV stabalized Clear /frosted Polycarbonate diffuser and Aluminium anodised with sandblast reflector. The System level Luminous efficacy ≥ 100 Lumen/W.SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K.The integral electronic driver must be potted & has a unique BIS Rnumber must be potted & has a unique BIS R number constantcurrent and Internal/external surge protection device of min. 4KV(LN) and efficiency > 85%, PF>0.9, THD<10% and input Voltagerange of 140-270V AC at 50Hz. System life of 50000 Burning hourswith 70% of Initial Lumens maintained . Driver current <750mA.Fixture must be in compliance with BIS Standards and Trade markCertificate complete in all respect.OEM Must have its own in houseNABL lab setup for all testing facilities for LED fixtures.(LM79/LM80) Certificate/ report with liable warranty ofproduct/accessories from OEM shall be submitted. All as per preapproved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . Minimum lumen output 3000 lm Post top Luminarie |
| 3 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. 50 mm |
| 4 | Add for supply and fixing of Pole OEM fabricated Mild steelOverhang of following size over the existing poles, Overhang shallbe painted with two coat of red oxide primer and two quote ofenamel paint of silver colour as per the direction of Engineerincharge. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 76.1 mm OD x 3.25 mm thickness |
| 5 | Supply and erection of Mild steel Swaged tubular pole conformingto IS: 2713-1980 (part I to II) with base plate, The pole shall bemade from steel tube & Pipe (IS:1141, Fe 410) including excavationof the pit and filling the same with C.C. of M-20 grade (1:1.5:3) frombase plate to 50 cm above ground level, with the help of steel framenot less than 40 cm dia up to 114.3mm outer dia and 50 cm beyond114.3mm outer dia around the pole. Duly finished with cementplaster, earthing terminals, cable entry with 32 mm dia. 'B' class GIcable sleeves. After eraction pole shall be painted with two coat ofred oxide primer and two quote of enamel paint of silver colour asper the direction of Engineer incharge complete as required offollowing height & designation. ( See Table P - 02 for specs. ) All asper pre approved by Engineer in-charge. For additional technicalparameters of products/ work , refer Annexure \\"A\\" attached withthis BSR . 9.0 Mtr. ( 410 SP - 28 ) |
| 6 | Providing and Laying RCC Foundation for Octagonal / ConicalStreet Light poles, High mast Poles as per Drawing attach at TableP-4 with Following Procedure & All as per pre approved byEngineer in-charge. For additional technical parameters of products/work , refer Annexure \\"A\\" attached with this BSR .A) Excavation of Pit for Foundation Size upto required depth fromGround levelB) Dressing of Pit and Dry stone pitching 200 mm thick includingsupply of stones and preparing surface complete.C) Providing and laying in position cement concrete of M-10 grade of75 mm thicknessD) Reinforcement for R.C.C. work with TMT bars includingstraightening, cutting, bending, placing in position and binding allcomplete.E) Centring and shuttering including strutting , propping etc. andremoval of form work for Footing and PedestalF) Providing & Fixing of 2 no. Required Size PLB HDPE Pipe &Foundation Bolt with template as per OEM Recommendations.G) Providing and Laying Reinforce cement Concrete of M-25 gradein Footing and Pedestal including Curing the foundation for 7 days.H) Providing and Fixing Nosing Angle 40 mm x 40 mm x 6mm with 2no. 100 mm long, 10 mm dia. Lugs on each face. Pole Foundation for Octagonal pole from 3 Mtr. To 6 Mtr. |
| 7 | Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr |
| 8 | Supply & drawing Wiring for sub mains ISI marked (IS:694) 1100 Volts grade PVC insulated flat twin core sheathed solid aluminium conductor with 10 SWG G.I. Support wire duly clipped etc. as required. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 4.0 sq.mm |
| 9 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 10 | Supply & fabrication steel structure with MS channel / angle / joist / ISMB /sheet etc. including welding, rivetting, cutting, nut & bolt , one coat of primer & two coat of enamel paint etc. as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 11 | Supply & Laying following size' B ' class , G.I. Pipe confirming to IS : 1239 P - 1 ( 2004 ) with accessories like bend, socket etc. for laying earth conductor/ strip / cable in ground/ surface/ recess as required. All as per pre approved by Engineer in-charge. (Earth Excavation will be Paid Extra)All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annex ure \\"A\\" attached with this BSR. 100 mm dia. |
| 12 | Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulator with standard short circuit withstand capacity , high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. Electrolytic grade Aluminium bus bar 6010 grade |
| 13 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . One day reserve (Analog type ) |
| 14 | SITC of 3 /4 pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant material having following current rating, short circuit breaking capacity at 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2:2003 with front face and centralised adjustable, trip free mechanisum, true contact position indicator, line load interchangeability, designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree, pollution degree 3, having positive isolation capability, push (test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage 690 V. provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connections etc. as required.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 250 Amp , 35 kA, adjustable O/L & adjustable S/C setting |
| 15 | Providing & Fixing of AC operated heavy duty 230 /440 Volt power contactor as per PWD specification for electrical Works, ISI marked IS/IEC 60947-4-1 : 2000 having provision of mechanical interlocking, auxilary contacts, Din rail mounting type including making connections, testing etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. |
| 16 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in- charge. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Four pole MCB (With B/C curve tripping Characteristics) 50/63 A rating |
| 17 | P & Fixing Powder coated CRCA sheet enclosures on existing angle iron frame by means of nuts and bolts and making holes , Din rail etc. as required.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 1.6 mm thick |
| 18 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediatedLaboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 16.0 Sq. mm 4 core |
| 19 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 16.0 Sq.mm |
| 20 | Add Extra for Laying of one number XLPE power cable of 11/33 KV (Earthed) voltage grade direct in ground including excavation of trench of size 120 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable. (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 21 | Add Extra in Item no.62.3 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 22 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre app+C33roved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. High Power LED Flood Light Minimum lumen output 8700 lm+C37 |
| 23 | Add Extra in Item no. 62.5 if Excavation done in Hard Rock / CCroad / TAR Road and making Good the same |
| 24 | Pipe Earthing as per IS:3043- 1987 with 3.0 Mtr. Long, 40 mm dia. ' B ' class G.I. Pipe IS: 1239 (Part-1) 2004, Equivalent to BS : 1387 with perforated holes of 12 mm dia ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in-charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . |
| 25 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 25mm x 3mm Alum. Strip |
| 26 | Providing & Fixing of IK08 IP-66 protected high power LED flood light system with single piece Pressure diecast aluminium housing, toughened glass diffuser with suitable lenses on LED to achieve various beam angles, of high power LED of 3 to 5 watt each . Integrated potted driver as a unique BIS R number having efficiency more than 85 % and in compliance to BIS certified and Trade mark certificate. The System level Luminaire efficacy >=125 lm/ wt. LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety .Power Factor >0.95 , THD(I) <10% , driver current <=750mA. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector , Surge Protection Min >=4KV internal and 10KV external but inside driver compartment, System life of 50000 Burning hours with 70% of Initial Lumens maintained, CRI>70 and CCT 5700K ±355K. Manufactures Word Mark/Name Engraved/ Embossing/ Screen printing on die cast housing to allow traceability/ authenticity. Fixture shall be IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR. High Power LED Flood Light Minimum lumen output 8700 lm High Power LED Flood Light Minimum lumen output 8700 lm |
| 27 | Providing and fixing of IP 65 protected Polycarbonate / Polysterenefuse box moulded with inside knock outs of following size withhinged cover, transparent window, PU gasket, locking arrangement,duly holded with 2 nos. pole clamps of 20 mm x 3 mm flat with nutand bolts, The box shall be provided with Din rail, 4 / 8 way 10.0 /16.0 sq.mm heavy duty connector, earth terminal, complete in allrespect. All as per pre approved by Engineer in-charge. Foradditional technical parameters of products/ work , refer Annexure\\"A\\" attached with this BSR . 125 mm X 200 mm X 122 mm |
| 28 | Decorative haritage pole in 4 Meter height. Pole upper section oflength 3mtr is of dia 76mm and 1 meter bottom section of dia114mm with decorative casting with base plate as per drawing.Provision for inside termination box with 4way connector & 1nos 6AMPS MCB for local isolation with cover.Complete in all aspectswith foundation bolts. |
| 29 | Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 70.0 Sq. mm 3.5 core |
| 30 | 8 SWG G.I. ( Hot Dipped ) WireSupply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu purity purity >95% thimble etc. as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Please Enable Macros to View BoQ information |