| 1 | Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, bell push, holders, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed. |
| 2 | M&L for point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed, FRLS(H) cable drawn through and including PVC casing caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS(H) cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC boards/bakelite sheets / and including factory made terminal boxes with modular cover plates and frames suitable for mounting switches, sockets, fan Regulators, accessories etc as specified and as directed for one light point or one fan point controlled by one, one way switchNOTES: (a) Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW, BLUE for Earth-Green and Neutral-Black) (b) All points shall be earthed up to fittings. |
| 3 | All as per serial item No. 2.00 here in before but for one bell/buzzer point controlled by one push button on the same board with other switches or independent. |
| 4 | All as per serial item No. 2.00 here in before but for one 6 Amp 3 pin socket outlet point on same board with other switches including earth wire. |
| 5 | All as per serial item No. 2.00 here in before but for one 6 Amp 3 pin socket outlet point on independent board including earth wire. |
| 6 | All as per serial item No. 2.00 here in before but for one light point controlled by two 2-way switches |
| 7 | All as per serial item No. 2.00 herein before but with 2.5 Sqmm, PVC copper stranded cable FRLS(H) type for phase, Neutral and earth for one 16 Amp, 6 pin socket (multipurpose) on independent board complete all as specified and as directed. |
| 8 | All as per serial item No. 2.00 herein before but with 4 Sqmm PVC copper stranded cable FRLS(H) type for phase, Neutral and earth for one 16 Amp, 6 pin socket (multipurpose) on independent board complete all as specified and as directed. |
| 9 | M & L point wiring with two runs of 1.5 sqmm for phase and neutral, single core, multistranded copper conductor cable of 1100 Volts grade,conforming to IS-694 1990, PVC insulated and unsheathed , FRLS(H) cable drawn through and including heavy grade PVC rigid conduit not less than 20 mm dia as reqd at site, totally concealed in walls/floors/ceiling including all conduit accessories/ fittings/ junction boxes/ inspection covers etc; of heavy grade, ISI marked and sunken terminal boxes of factory made 16 SWG pressed steel housing, totally concealed in walls and including factory made terminal boxes with modular cover plates and frames fixed flush with wall surface by means of brass screws and sunk/cup washers, for mounting of switches, sockets fan regulates etc; including 1.5 Sqmm 1100 V grade PVC insulated, unsheathed flexible multi stranded copper conductor FRLS(H) cable as continuous earth wire connected to metallic bodies of luminaries/fans etc; at one end and to common earth dolly at other end, all as specified & directed for light point or one fan point controlled by one, one way switch NOTES: (a) Proper colour coding shall be adopted for wiring (for phase-RED,YELLOW, BLUE for Earth-Green and Neutral-Black) (b) All points shall be earthed up to fittings.(c) The unit rate quoted shall deeemed to be included cutting chases in walls for concealed wiring & making good disturbed surfaces . |
| 10 | All as per serial item No. 9.00 but for one light point controlled by two 2-way switches |
| 11 | All as per serial item No. 9.00 but for one bell / buzzer point controlled by one push button on the same board with other switches or independent |
| 12 | All as per serial item No. 9.00 but for one 3 pin 6 Amp Socket outlet point on same board with other switches including earth wire as per description given above and connected to common earth and earth terminals. |
| 13 | All as per serial item No. 9.00 but for one 3 pin 6 Amp Socket outlet point on independent board including earth wire as per description given above and connected to common earth and earth terminals. |
| 14 | All as per serial item No. 9.00 but with 2.5 Sqmm cables for one 16A, 6-Pin socket outlet point on independent board with & including 2.5 Sqmm FRLS(H) cable as earth wire complete. |
| 15 | S&F Modular switch single pole one way 6 Amps 1 module complete all as specified and directed . |
| 16 | S&F Modular switch single pole one way 16 Amps 1 module complete all as specified and directed. |
| 17 | S&F Modular Bell Switch 6 Amp 1 Module complete all as specified and as directed. |
| 18 | S&F Modular Switch 2 way 1 module complete all as specified and as directed. |
| 19 | S&F Modular socket 6 Amp 3 pin 2 module complete all as specified and as directed. |
| 20 | S&F Modular socket 16 Amp 3 pin 2 module complete all as specified and as directed |
| 21 | S&F Modular fan regulator Step Type, 2 Module suitable for 1200/1400 mm sweep BLDC/ Normal fansComplete all as Specified and as directed. |
| 22 | S&F ceiling rose fancy type surface bakelite three terminal type complete all as specified and as directed. |
| 23 | S & F LED lighting fixture with extruded polycorbonate,environmental friendly,energy efficient ready to use pack LED Tube light fitting 20 Watt 4 feet with LED light source 6500k with uniform light output,with all accessories including its connection complete with all as specified and directed by Engineer-in-charge.Make:HAVELLS LED PRIDEUltra next Cat No LHEXAZP7PN1W010 or equivalent approved make in CA |
| 24 | S&F in replacement decorative ultra slim square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient of capacity 10 Watt , 6500 K with inbuilt driver complete fitting and all other accessories fitting arrangements including connecting up with two core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make : Cat No. LHEXACP7IN1W010 of Havells or equivalent model of makes specified in PS |
| 25 | S&F in replacement LED light fitting 1x 9W / 1X10W bulkhead luminaires including LED light driver holder connecting up with two core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 26 | S&F in replacement LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver two core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 27 | S&F in replecement unique slimlest recess cum surface LED panel luminaire 300 mm x 300 mm, 18 watt, 6500K, 220 V AC with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp including connecting up with driver two core flexible copper conductor cases of suitable size complete all as specified and as directed. Make : Cat No. LHEAABP7lN1W018 of Havells or equivalent of makes specified in PS |
| 28 | S&F in replacement round shape 15 watt 220 volts (WW) AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.Make : Cat No. LHEBADP6IZ1W015 of Havells or equivalent of makes specified in PS |
| 29 | S&F in replacement lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed. |
| 30 | S&F in replacement lamp 3 Star LED 9 Watt, 230 volts 50 Hz AC complete all as specified and as directed.Make : Cat No. LHDDDEDIC5R009 of Havells or equivalent of makes specified in PS |
| 31 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), Triple pole and neutral, 415 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 32 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 16 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed |
| 33 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 12 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed |
| 34 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed |
| 35 | S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used), single pole and neutral, 240 volts, 4 way, protection class IP-42, suitable for fixing MCBs, Isolators etc, confirming As per IEC 61439-3, suitable for flush mounting and surface mounting, with 100 Amps rated copper busbar, with Neutral bar, Earthbar and cable alley for cable managment, fully shrouded, Neutral bars, prefittes masking sheet complete all as specified and as directed. |
| 36 | S&F in replacement single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp 240 Volts complete all as specified and as directed. |
| 37 | S&F in replacement of MCB SP, C Curve, 6 to 32 Amps 10 KA single pole AC 230 volts complete all as specified and as directed. |
| 38 | S&F in replacement of MCB SPN, C Curve, 40-63 Amps 10 KA single pole AC 230 volts complete all as specified and as directed. |
| 39 | S&F in replacement of MCB C Curve TPN 40-100 Amps, 415 V complete all as specified and as directed. |
| 40 | S&F in replacement of bell multi music type, AC, 230 volts, single phase complete all as specified and as directed. |
| 41 | M&L for sub main wiring with 2 runs of 6.0 sqmm, single core, PVC insulated & unsheathed FRLS(H) cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 6.0 sqmm single core PVC insulated & unsheathed FRLS(H) copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit complete all as specified and as directed.NOTES : (a) Proper colour coding shall adopted for wiring (for phase-RED, YELLOW, BLUE for Earth- Green and Neutral-Black) (b) Three runs of 6 sq.mm cable and one run of PVC casing caping shall be measured as one unit. |
| 42 | M&L for sub main wiring with 2 runs of 4.0 sqmm, single core, PVC insulated & unsheathed FRLS(H) cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4.0 sqmm single core PVC insulated & unsheathed FRLS(H) copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed. NOTES: (a) Proper colour coding shall adopted for wiring (for phase-RED, YELLOW, BLUE for Earth- Green and Neutral-Black) (b) Three runs of 4 sq.mm cable and one run of PVC casing caping shall be measured as one unit |
| 43 | M&L for sub main wiring with 2 runs of 2.5 sqmm, single core, PVC insulated & unsheathed FRLS(H) cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size PVC Casing Capping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed FRLS(H) copper conductor cable as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building as ordered and testing on completion including taking down old submain wiring and any type of casing/caping/Conduit, complete all as specified and as directed.NOTES: (a) Proper colour coding shall adopted for wiring (for phase-RED, YELLOW, BLUE for Earth- Green and Neutral-Black) (b) Three runs of 2.5 sq.mm cable and one run of PVC casing caping shall be measured as one unit |
| 44 | M &L for sub main wiring with 2 single core FRLS(H) PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 4.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 4.0 Sqmm 1100 V grade FRLS(H) PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified and as directed. Note: Three runs of 4.0 Sqmm cable and one run of PVC Conduit will be measured as one unit. |
| 45 | M &L for sub main wiring with 2 single core FRLS(H) PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 6.0 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 6.0 Sqmm 1100 V grade FRLS(H) PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified and as directed. Note: Three runs of 6.0 Sqmm cable and one run of PVC Conduit will be measured as one Rm unit. |
| 46 | M &L for sub main wiring with 2 single core FRLS(H) PVC insulated unsheathed, multi stranded flexible copper conductor 1100 volts grade cables 2.5 Sqmm drawn through concealed conduit and including PVC conduit heavy grade with and including 1 single core 2.5 Sqmm 1100 V grade FRLS(H) PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub main wiring complete all as specified & directed. NOTES: (a) Proper colour coding shall adopted for wiring (for phase-RED, YELLOW, BLUE for Earth- Green and Neutral-Black) (b) Three runs of 2.5 sq.mm cable and one run of PVC Conduit will be measured as one unit. |
| 47 | S&F in replacement Emergency/ Inverter tube light fitting decorative ultra slim/ square profile LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient of capacity 20 Watt , 6500 K with inbuilt driver, luminous efficiency 90 LM/watt, complete fitting and all other accessories fitting arrangements including connecting up with suitable flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.Make: HAVELLS Cat No LHEXACP7FN1W020 equivalent model of makes specified. |
| 48 | S&F in replacement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor of size 4 Sqmm complete all as specified and as directed. |
| 49 | S&F in replecement 1100 Volt grade, heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor of size 6 sqmm complete all as specified and as directed. |
| 50 | S&F in replacement 1100 Volt grade heavy duty cable PVC insulated aluminium Stranded conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistranded conductor size 10 sqmm complete all as specified and as directed. |
| 51 | S&F in replacement 35/ 40 Watt building mounted LED security light fitting complete made up of pressure die cast housing with toughened glass and individual high power LEDs with secondary optics, IP66 protection and impact resistance of IK07 & 10KV external SPD, including GI bracket made out of GI pipe 40/50 mm bore, medium grade pipe 1.2m long bend to shape required fixed to pole / wall with 02 Nos MS clamps made out of flat iron 40x5 mm including nuts, bolts and washer, painting with two coats aluminium paint over a coat of primer, suitable for LED fitting complete all as specified and as directed.Make : Havells Cat Part No ENDURASUNDOWNSL35WLED765PASYBOPC or equivalent of makes specified. |
| 52 | S&F in replacement garden light of Bamboo type-IP 65 of capacity 10 watt, 5700K new generation, energy saving, environmental friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LED as light source with PCC Base for fixing of lights with proper nut & bolts including electrical connection wire complete all as specified and as directed. Make- Cat part No. TURINBLS10WLED857PSYMTOPC of Havells or equivalent of makes specified in PS |
| 53 | S&F in replacement of LED driver unit ISI marked suitable for recessed mounting fitting of 15/18 Watts complete all as specified and as directed.Make :- Cat No. LSSLNW0170 of Havells or equivalent of makes specified in PS |
| 54 | S&F in replacement of LED driver unit ISI marked suitable for recessed mounting fitting of 24 Watts complete all as specified and as directed.Make :- Cat No. LSSLNW0171 of Havells or equivalent of makes specified in PS |
| 55 | Taking down unserviceable ceiling fan, 1200/ 1400 mm sweep, any make, opening, taking out burnt copper winding, cleaning all parts, rewinding with new super enamelled copper wire of matching size and gauge and number of turns as required, varnishing and heating the winding including providing paper insulation including replacement of ball bearings, greasing re-assembling the fan as a one unit and re-fixing ceiling fan at the existing site / rooms and connected with 23/0.0076 three core PVC flexible cable from ceiling rose to fan etc complete all as specified. |
| 56 | Taking down unserviceable Exhaust fan any sweep and make, opening, taking out burnt copper winding, cleaning all parts, rewinding with new super enamelled copper wire of matching size and gauge and number of turns as required, varnishing and heating the winding including providing paper insulation including replacement of ball bearings, greasing re-assembling the fan as a one unit and re-fixing ceiling fan at the existing site / rooms and connected with 23/0.0076 three core PVC flexible cable from ceiling rose to fan etc complete all as specified. |
| 57 | Taking down unserviceable wall mounted fan/table fan/cabin fan /Padestal fan any size and make, opening, taking out burnt copper winding, cleaning all parts, rewinding with new super enamelled copper wire of matching size and gauge and number of turns as required, varnishing and heating the winding including providing paper insulation including replacement of ball bearings, greasing re-assembling the fan as a one unit and re-fixing ceiling fan at the existing site / rooms and connected with 23/0.0076 three core PVC flexible cable from ceiling rose to fan etc complete all as specified. |
| 58 | Taking down unserviceable ceiling fan, 1200/ 1400 mm sweep, any make, with blades, opening, cleaning all parts, including replacement of ball bearings, greasing re-assembling the fan as a one unit and re-fixing ceiling fan at the existing site / rooms and connected with 23/0.0076 three core PVC flexible cable from ceiling rose to fan etc complete all as specified. |
| 59 | Supply only capacitor 2.5 mfd to 3.15 mfd complete all as specified and as directed. |
| 60 | Supply only capacitor 4 mfd, for exhaust fan/wall mounted fans etc of 300mm / 450mm / 600 mm sweep complete all as specified and as directed. |
| 61 | M&L in repairs for down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and as directed. |
| 62 | M&L in repairs for down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.60 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and as directed. |
| 63 | M&L in repairs for down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 1.50 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as per specified and as directed. |
| 64 | M&L for preparation of surfaces and spray painting to ceiling fans (in situ) of any type, size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and rewriting the MES number in black paint in appropriate size and shape all as specified and as directed. |
| 65 | M&L for preparation of surfaces and spray painting to exhaust fans (in situ) of any type , size and make, with super enamelled heat resistant synthetic white paint duly filling the cavities with filler and re-writing the MES number in black paint in appropriate size and shape all as specified and as directed. |
| 66 | Supply and fix in replacement PVC Plastic body Exhaust fan of size 300 mm sweep with louvers complete including PCC and Plywood packing work/ alterations to existing window/ wall to make arrangument as per site reqmt complete all as specified and directed . |
| 67 | Supply and fix in replacement PVC Plastic body Exhaust fan of size 250 mm sweep with louvers complete including PCC and Plywood packing work / alterations to existing window/ wall to make arrangument as per site reqmt complete all as specified and directed . |
| 68 | S&F in replacement, post top lantern LED type 15 watt, 230 volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete including suitable size of GI pipe as per lamp size including connection and testing complete all as specified and as directed .Make : Havells Cat No CORALPT15WLED757PSYMTOPC |
| 69 | Taking down carefully water Geyser 25/50 ltrs capacity by unscrewiring nuts bolts, water inlet/outlet pipes from walls/foundation complete repair of base assembly of geyser made out of copper base plate with gasket and proper size of nuts, bolts & washers, with replacement of inlet and outlet pipe, connection of geyser with flexible copper cable 3 core of size 23/0.0076 including refixing in position after carrying out repair including making connectin to the water inlet, outlet pipe, electric connection and testing complete all as specified and as directed. |
| 70 | S&F in replacement heating element, triangular or square type, 1500watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed. |
| 71 | S&F in replacement heating element, triangular or square type, 2000watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed. |
| 72 | S&F in replacement thermostat, auto cut with thermal setting upto 80 degree centigrade, 230 Volts, suitable for existing geysor(25/50 lit) of various capacities all as specified and as directed. |
| 73 | S&F in replacement inner tank of 25 ltr capacity geyser as per existing at site all as specified and as directed. |
| 74 | S&F in repairs, indicator lamp, 220 Volts, AC, suitable for 25/50 ltrs capacity of geyser all as sepecified and as directed. |
| 75 | S&F in repairs, 15mm dia non return valve, made out of brass, fixed in vertical position all as sepecified and as directed. |
| 76 | S&F in replacement for mild steel hold fast/fasteners fixing to wall, suitable for hanging of geyser of any capacity including making good surface with cement mortar 1:4 and surface finished as per existing surfaces including taking down old existing hold fasts/brackets complete all as specified and as directed. |
| 77 | S&F in replacement, heat resistant, PVC, flexible connection pipe, 450 mm long, suitable for 15 mm dia pipe with brass creamed nipple and nuts, heavy duty pressure grade 6 Kg/cm2 all as specified and as directed. |
| 78 | Taking out the old thermostat/heating element and refixing the same after descaling/ cleaning and making electrical connection and calibrating/adjusting to a temperature rating as per manufacturer recommendations all as specified and as directed. |
| 79 | Supply, laying, testing and commissioning of UG LT cables, 35 Sqmm x 3.5 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed. |
| 80 | Supply, laying, testing and commissioning of UG LT cables, 25 Sqmm x 3.5 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed. |
| 81 | Supply, laying, testing and commissioning of UG LT cables, 6 Sqmm x 2 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed. |
| 82 | Supply, laying, testing and commissioning of UG LT cables, 10 Sqmm x 2 core, 1100 volts grade, XLPE insulated, screened and PVC sheathed, galvanised steel strip or wire armoured with multi stranded aluminium conductor, ISI marked, heavy duty including cable glands, cable lugs in LT panel/MDB in building etc to suit the cable including material and labour for all jointing/connecting material as required size, cables laid in trenches/ducts/under plinth floors passing through pipes etc, fixed on wall including taking out old cable and cable covers complete all as specified and directed. |
| 83 | Earth work in excavation by mechanical means (Hydraulic excavator)/ in foundation trenches or drains or laying of pipe or for shafts, wells cesspits,man holes etc (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 84 | Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick as in soil complete all as specified and as directed. |
| 85 | M&L in replacement for GI tubing 40 mm bore light grade for protection of cable with all necessary fittings accessories such as MS 40x3mm clamps of suitable length, nuts, bolts and washers and fixed complete to wall/ceiling or laid under floors complete all as specified and as directed. |
| 86 | M & L for Double Walled Corrugated DWC HDPE Pipe (N-450) of outer dia 63mm including 90 degree bends with coupler and rubber ring laid in trenches of size 63 mm suitable for cable protection complete all as specified and directed. |
| 87 | M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia, by means of nut bolts, check nuts and washer and the GI Earth wire connected upto main earth point/DBs alongwith 15mm dia GI medium grade protection pipe including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm x 25 mm x 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade |
| 88 | 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion. Note : Rate of GI earthwire and GI protection pipe upto 7.5 mtr length shall be deemed to be included in this item. |
| 89 | S&F repairs socket outlet, flush type, 3 pin, 6 Amp, multipurpose, 230 volts, single pole, one way suitable for 3 pin/2pin, 5 Amp plug top white/ivory finish all as specified & as directed. |
| 90 | S&F in repairs, switch/socket combination with box type outlet, 3 pin, 6 Amps, flush type (Multi purpose), piano type, AC 230 Volts. all as specified and as directed. |
| 91 | S&F in repairs, switch/socket combination with box type outlet, 2 in 1, 3 pin, 6 Amps and 16 Amp, flush type (Multi purpose), piano type, AC 230 Volts all as specified and as directed. |
| 92 | S&F in repairs, switch piano, flush button, 6 Amp, single pole, one way, 230 volts, white finish all as specified & as directed. |
| 93 | S&F in replacement of plug top 3 pin of capacity 15/16 Amp complete all as specified and directed . Please Enable Macros to View BoQ information |