| 1 | Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge |
| 2 | Taking down the existing unserviceable MCBs/MCCBs of any type / capacity / description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge |
| 3 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sq mm (FRLSH) in and including PVC casing & caping/Conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 6.0 sqmm cable & One run of 6.0 sqmm cable and One run of PVC casing & caping/Conduit shall be paid as one unit length. |
| 4 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.Note: Two runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length. |
| 5 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 4.0 Sqmm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 4.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.Note: Two runs of 4.0 Sqmm cable & One run of 4.0 Sqmm cable shall be paid as one unit length. |
| 6 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLSH) including PVC casing caping/conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of PVC casing & capping shall be paid as one unit length. |
| 7 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sq mm (FRLSH) in existing concealed conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sq mm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge. Note: Two runs of 10.0 sqmm cable & One run of 10.0 sqmm cable and One run of existing concealed conduit shall be paid as one unit length. |
| 8 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for Three phase) circuit with Four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 Sqmm (FRLSH) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.Note: Four runs of 6.0 Sqmm cable & One run of 6.0 Sqmm cable shall be paid as one unit length. |
| 9 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for Three phase) circuit with Four single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 Sqmm (FRLSH) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 Sqmm (FRLSH) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed by Engineer-in-charge.Note: Four runs of 10.0 Sqmm cable & One run of 10.0 Sqmm cable shall be paid as one unit length. |
| 10 | wall cutting channels grooves or rebates n exc 15 cm girth and trimming surface and including pvc conduit pipe isi marks nominal cross section size including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed by Engineer-in-charge |
| 11 | S&F in repair LED 20W inverter batten type fitting 3/4 feet long aluminium extruded housing, charging time 10-12 Hrs with 04 Hrs backup, IP-20, rated voltage 230 V, 50 Hz, system wattage 20W +/- 10%, system current less than 102 mA, power factor more than 0.95, system lumen efficiency 100lm/watt, CCT 6500K, CRI more than 80, THD less than 30%, driver efficiency more than 85% complete all accessories prewired and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge |
| 12 | Supply and fixing of LED box type Integrated Batten 40 watt having Aluminum Extruded housing in white powder coated Finish with high translucent PC Cover, Elegant Design, IP 20 Protection. Dimensions of the Fitting Shall be Not less then 1200 MM (Length) X 40 MM (Width) X 63 MM (Height ). Lumens output of the fitting shall be not less then 4400 lm, CCT 5700 – 6500K, buring hours 50,000 Surge Protector 4 KV, PF>= 0.95 , Separate detachable type Electronic constant current drivers for easy replacement and maintenance, THD < 10% , Necessary mounting arrangements .The fixture shall be suitable for wall mounting /suspension mounting as per site requirement . The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79 / LM80 / Test Report complete all as specified and directed by Engineer-in-charge |
| 13 | S & F for DB VTPN 8 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge |
| 14 | S & F for DB VTPN 6 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge |
| 15 | S & F for MCCB DB VTPN 4 way 415 V double door IP 54 with provision for FP MCCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply complete all as specified and directed by Engineer-in-charge |
| 16 | S & F for sheet metal enclosure MCB DB TPN 4 way double door IP 54 with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and directed by Engineer-in-charge |
| 17 | S & F for sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door IP 54 with magnitic locking system complete all as specified and directed by Engineer-in-charge |
| 18 | S & F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door IP 54 with magnitic locking system complete all as specified and directed by Engineer-in-charge |
| 19 | S&F Sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed by Engineer-in-charge |
| 20 | S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 160 Amps with extended terminals complete all as specified and directed by Engineer-in-charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site.Note : MCCB Rating ICS=100 % ICU |
| 21 | S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 125 Amps with extended terminals complete all as specified and directed by Engineer-in-chargeNote:- Suitable size and frame of MCCB required as per existing DBs at site.Note : MCCB Rating ICS=100 % ICU |
| 22 | S & F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified and directed by Engineer-in-charge.Note:- Suitable size and frame of MCCB required as per existing DBs at site.Note : MCCB Rating ICS=100 % ICU |
| 23 | Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 Amps to 100 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge |
| 24 | Supply and fixing miniature circuit breaker (MCB) of single pole and neutral SPN 40 AMP to 63 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge |
| 25 | Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engineer-in-charge |
| 26 | Taking out carefully copper/GI earthing complete including GI pipe and removing materials for taking credit and making good disturbed surface complete all as specified and directed by Engineer-in-charge |
| 27 | Taking down carefully copper/GI earthing Strip Copper/Aluminium /GI wire complete including and removing materials for taking credit and making good disturbed surface complete all as specified and directed by Engineer-in-charge |
| 28 | M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron strip 32x6 mm as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engg-in-Charge. Note : Testing of earthing of any type, after disconnecting from test point and other loops by using ISI marked digital/Analog earth tester of reputed make and test result shall be entered in a Earth Testing register and put up to the Engr-in-Charge after testing complete all as specified and directed. Test result for item No. 6 and all earthing in schedule to be provided to Engr-in-Charge before completion of work. Earth tester to be provided by the contractor himself. |
| 29 | M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to 4.00 mm dia GI wire as earthing lead up to 7.5 mtr by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 15 mm dia light grade pipe for earth lead protection connected to electrical equipment and earthing test point , earth dolly and earth chamber as shown in elect plate No 2 of SSR Pt-I including all necessary earth work, excavation, earth chamber with PCC 1:3:6, Type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20 mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed Engr-in-Charge. Note : Testing of earthing of any type, after disconnecting from test point and other loops by using ISI marked digital/Analog earth tester of reputed make and test result shall be entered in a Earth Testing register and put up to the Engr-in-Charge after testing complete all as specified and directed. Test result for item No. 7 and all earthing in schedule to be provided to Engr-in-Charge before completion of work. Earth tester to be provided by the contractor himself. |
| 30 | M & L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep. Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed by Engineer-in Charge. Please Enable Macros to View BoQ information |
| 31 | M & L for maintenance free chemical earthing with copper plating earthing electode inner pipe dia 42mm and outer pipe dia 76mm coating thickness of 250 mircrons over the rod and 3 mtr long duly inserted in ground by making a bore hole of 250 mm dia, 16 feet deep. Earthing enhcancing compound of 50 kg in sullery form shall be poured in hole after insertion of eletrode, remaining portion of hole shall be filled with excavated earth, interconnected with copper strip of size 20x3 mm and connected by means of exothermic brazing & protected by GI pipe light grade 32 mm bore and PCC (1:3:6) type C1 earth chamber & cast iron earth pit cover 300x300x3 mm connecting to test point & testing on ground complete including excavation, earth work, boring in any type of soil strata & cleaning of site complete all as specified and directed by Engineer-in Charge. Please Enable Macros to View BoQ information |