| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or tacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, leveling, dressing and ramming the bottom, bailing out water as required complete; Depth of excavation not exceeding 1,500 mm. |
| 2 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work); With earth obtained from excavation of foundation. |
| 3 | a. 250 mm thick Brick work with Fly Ash Bricks (250 mm x 125 mm x 75 mm) as per IS 12894:2002 in cement mortar (1:4) a) In superstructure, ground floor. |
| 4 | b. 125 mm. thick Fly ash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor. |
| 5 | c. Dismantling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 6 | Removal of rubbish, earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge. |
| 7 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/ staging where necessary.[Excluding cost of chipping over concrete surface]. In ground floor. |
| 8 | a. 20mm thick plaster 4:1 |
| 9 | b. 15mm thick plaster 4:1 |
| 10 | c. Stripping off worn out plaster and raking out joints of walls, ceilings etc. up to any height and in any floor including removing rubbish within a lead of 75m as directed. |
| 11 | a. Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor [Pakur Variety] (1:3:6). |
| 12 | b. Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement, if any, as per relevant IS codes. Pakur Variety. |
| 13 | c. Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m In ground floor including roof. up to 150 mm. thick. |
| 14 | Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc.NOTE: Cement 0.152 cu.m. per100 sq.m. |
| 15 | Hire and labour charges for shuttering with centering and necessary staging up to 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (up to roof of ground floor). 25 mm to 30 mm shuttering without staging in foundation. |
| 16 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc. initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction; For works in foundation, basement and up to roof of ground floor/up to 4 m; Tor steel/Mild Steel. |
| 17 | a. Artificial stone in floor, dado, staircase etc. with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary) and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface and application of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement). Using grey cement 25 mm. thick. In ground floor. |
| 18 | b. Dismantling artificial stone flooring up to 50 mm. thick by carefully chiseling without damaging the base and removing rubbish as directed within a lead of 75 m. In ground floor including roof. |
| 19 | a. Supplying fitting and fixing in position approved P.V.C. door frame (Matt finish) made of extruded P.V.C. multi chamber hollow section having dimensions 60mm x 50mm x 2mm (+/-0.2mm), horizontal section will be joined with vertical section by galvanised steel screws after inserting two number steel brackets as reinforcement making suitable space for placing hinges, one steel tube 40mm x 20mm x 1.20 mm will be inserted on one full vertical side of the frame (hinge side) as reinforcement, the frame will then be fixed in the opening with the help of P.V.C. expandable fastener/wooden gutties and galvanised steel screws including cost of all materials and labour, hire charges of tools and appliances, carriage of all materials, taxes and all other incidental charges complete. |
| 20 | b)Supplying fitting and fixing P.V.C. door shutter of approved quality & shade in position, the style & rail of the P.V.C. door shutter will be made of rigid P.V.C. multicavity hollow chamber of suitable size and section with 2.0 mm (+/-0.2 mm) wall thickness, the section will have 2nos. built in beads, horizontal & vertical section shall be fixed to each other by self-tapping screws and 2 nos. of solid plastic or M.S. tubular galvanised brackets of length 200mmx80mm and ther100mmx100mm both 1.20 mm in each corner of the shutter frame for placing hinges. Polymer based multicavity hollow section of 105 mm x37mm with 2.0 mm (+/- 0.2 mm) wall thickness will be fitted in the middle as lock rail reinforced by solid polymer bar of 200 mm long at both ends abd screws from both sides. The section frame will then be fitted in by PVC panels of size 100 mmx20 mm with wall thickness of 1.2 mm (+/- 0.2 mm) and 2 nos. of 6 mm dia and screws from both sides 6mm dia bright rod will be inserted horizontally with both side check and nut system and stretches where fixing of hinges / hasp bolt / tower bolt / door ring are required to be strong enough to with stand wear and tear. The rate is inclusive of cost of all materials, labour, and hire of tools and plants and appliances. Carriage of all materials taxes and all other incidental charges complete. The rate is exclusive of cost of hinges, hasp bolt, tower bolt, door ring etc. |
| 21 | M.S. gate of Jail type as per approved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge. In ground floor. |
| 22 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc., including hoisting in position, straightening if required, fixing lugs in cement concrete (1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing. Openable steel windows as per IS sizes with side hung shutter sand horizontal glazing bars. [The extra rate admissible for the openable portion only] |
| 23 | Colour washing with any shade with Stainers, as required including cleaning and smoothening surface thoroughly: (i) Internal surface (All floors) Two coats (on new works only). Other than yellow, pink. |
| 24 | i) Applying decorative cement based paint of approved quality after preparing the surface including scraping the same thoroughly (plastered or concrete surface) as per manufacturer's specification. Two coats. |
| 25 | ii)Applying Exterior grade Acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive decorative textured (matt finish) or smooth finish acrylic exterior emulsion paint including scraping and preparing the surface thoroughly, complete as per manufacturer’s specification and as per direction of the EIC. In Ground Floor: One Coat. |
| 26 | Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary : |
| 27 | i) On metal surface With super gloss (hi-gloss) Two coats (with any shade except white). |
| 28 | ii)Priming one coat on steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 29 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. (A) Floor With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91Kg/ Sq.m & joint filling using white cement slurry @ 0.20 kg/ Sq.m Area of each tile upto 0.09 Sq.m. Coloured decorative. |
| 30 | Taking out carefully G.C.I. or C.I. or asbestos sheets (including ridges etc.) from roof or wall after unscrewing bolts, nuts, screws etc. and stacking the material at site as directed. (Payment to be made on measurement of portion of roof or wall removed.) |
| 31 | Taking out wind-tie from roof including cutting out rusted bolts, nuts etc. and removing materials to any distance within the compound and stacking. |
| 32 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of 150 grams per sq. meter (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa of trapezoidal profile of approved make (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self-tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc. complete with 150 mm end lap and one corrugation minimum side lap. (Payment to be made on area of finished work). (i) In Roof:- a) With 0.50 mm thick sheet. . |
| 33 | M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel sections conforming to IS: 226, IS: 808 & SP (6)- 1964 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rates includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental charges such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural members only in finished work as per IS specified weight. Payment for gusset, bracket, cleat, rivets, bolts and nuts may be made by adding the actual weight of such items with the weight of finished structural members or 7% of weight for finished structural members weighing not less than 22.5 Kg. / m. or 15 % of weight for finished structural members weighing less than 22.5 Kg. / m. may be increased allow for bracket, cleat, rivet, bolts and nuts etc. and no separate payment being made for these items, as per direction of Engineer In Charge. The rates are considered for a height of erection 8m. / 2nd floor level from the ground. Add 1.5% extra over the rate for each additional floor or 4m. beyond initial 8m. or part thereof. |
| 34 | For Structural Works in Roof Trusses etc. using joists, channels and angles of specified section weighing less than 22.5 kg/ m. |
| 35 | A) Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992. |
| 36 | (i) Single Socketed 3 Meter Length. (a) 110 mm. |
| 37 | ii) Double Socketed 3 Meter Length. (a) 110 mm. |
| 38 | B) Labour for fitting and fixing U.P.V.C. pipes for above ground work including cost of jointing materials etc. fitting and fixing all necessary specials, cutting pipes, cutting holes in walls or R.C. floor where necessary and mending good all damages excluding the cost of masonry or concrete work, if necessary, but including the cost and fitting and fixing holder bat clamps (any floor) or for underground work including cutting trenches up to 1.5 meter and refilling the same complete as per direction of the Engineer-in-charge. (Payment will be made on center line measurement of the total pipeline including specials. |
| 39 | (A) Above ground (i) 110 mm dia. |
| 40 | (B) Underground (i) 110 mm dia. |
| 41 | Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 |
| 42 | (i) Door Tee 110mm. |
| 43 | ii) Door Bend (T.S.) 110mm. |
| 44 | (iii) Vent Cowl 110 mm. |
| 45 | Removing sludge from septic tank, soak well etc. by methor labour including disposal of the same outside the compound as directed. Up to 50 users: - Within a lead of 150 meter. |
| 46 | Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007. with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbow, nipple, long screw, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required, jointing materials in any position above ground. (Payment will be made on the center line measurements of total pipe line including all specials. No separate payment will be made for accessories, specials.(A) For Exposed Work (i) CPVC Pipes Class-1, SDR-11. |
| 47 | a) 15 mm dia. |
| 48 | b) 20 mm dia. |
| 49 | c) 25 mm dia. |
| 50 | B) Labour for dismantling G.I. pipe with fittings. |
| 51 | a) 15 mm dia. |
| 52 | b) 20 mm dia. |
| 53 | c) 25 mm dia. |
| 54 | Supplying, fitting and fixing shower of approved brand and make. Polythene overhead shower of approved make 15 mm X 125 mm. |
| 55 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. a) With 'P' trap. |
| 56 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. E.W.C. Bestolite (solid type) black. |
| 57 | Supplying, fitting and fixing 10 liter P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete, C.I. brackets including two coats of painting to bracket etc. |
| 58 | Wash basin vitreous china of approved make (without fittings) supplied, fitted and fixed in position on 75mm X 75 mm X 75 mm wood blocks and C.I. brackets including two coats of painting of C.I. brackets. 550 mm X 400 mm size. |
| 59 | Supplying, fitting & fixing approved brand P.V.C. connector white flexible with both ends coupling with heavy brass C.P. nut 15 mm dia. 450 mm long. |
| 60 | a) Supplying, fitting and fixing approved brand 32 mm dia. P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps; 750 mm long. |
| 61 | b) Supplying, fitting and fixing 32 mm Polythene Waste fittings complete. |
| 62 | a) Polythene pillar cock (EMCO/ATLAS on equivalent) 15mm. |
| 63 | Supplying, fitting and fixing bib cock. a) Polythene Bib Cock / Stop Cock (HD) with plastic inlet (EMCO/ATLAS or equivalent);15 mm. |
| 64 | Supplying, fitting and fixing beveled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (i) 600 mm X 450 mm. |
| 65 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. 470 mm X 280 mm X 340 mm. |
| 66 | Supplying, fitting and fixing Squatting plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid separately). Please Enable Macros to View BoQ information |