| 1 | B & R Division Items |
| 2 | Demolition cement concrete (unreinforced) incl old membrane as water proofing if any of any description and in any position not otherwise specifically provided for complete all as specified & as directed. |
| 3 | Demolition of lime concrete /lean concrete/ brick bats (above ground level) in sunken portion of slab, including removal of rubbish outside MoD land, complete all as specified and directed. |
| 4 | Demolition of cement concrete(reinforced)of any description & in any position not otherwise specifically provided for complete all as specified |
| 5 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and as directed. |
| 6 | Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) and disposing off complete all as specified and as directed. |
| 7 | Dismantling wrought iron on MS work or mild steel work of any description complete all as specified and directed. |
| 8 | Dismantling of plain or corrugated steel sheeting, any gauge or any thickness in roof covering /wall cladding all as specified. |
| 9 | Dismantling of asbestos cement (Corrugated or semi corrugated etc) as in roof covering all as specified. |
| 10 | Dismantling of timber scantling 40 Sqcm and over in section, in any position in unframed work . |
| 11 | Dismantling of timber fillets rails, posts, rafters, purlins etc under 40 Sqcm in section, in any position in framed work . |
| 12 | Dismantling wall and ceiling boards (fibre, pulb, insulation etc) or insulation boards slabs/blankets any thickness including cover fillets all as specified and as directed. |
| 13 | Dismantling boarding any description fixed in any position with nails all as specified and as directed. |
| 14 | Dismantling of rain water pipe of any type and any size including fitting complete all as specified and as directed. |
| 15 | Taking down cement plaster on brick or stone walls, and plaster on roof surface etc. including raking out joints hacking for key scrubbing down with water |
| 16 | Taking up or down 15mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 17 | Taking up or down 20mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 18 | Taking up or down 25mm bore steel water tubing and connections from any location / position including disposing off, etc. complete all as specified and as directed. |
| 19 | M&L for Excavation of over area n exc 1.5 m in depth for foundation, etc. and getting out getting out in soft/loose soil complete all as specified and directed |
| 20 | M&L for Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed |
| 21 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.all as specified and directed. |
| 22 | Material and labour for Shingle filling in floors 200mm deep complete all as specified and directed. |
| 23 | M&L for hardcore of broken stone gauge n exc 63mm, deposited, spread and leveled in layer n.exc 15cm thick, watered and rolled / rammed to a true surface all as specified and directed . |
| 24 | M&L for cement concrete type 1:4:8 D-2 (40mm graded crushed stone aggregates) in foundation filling and mass concrete complete all as specified & as directed . |
| 25 | M&L for PCC (1:3:6) type C-2 of depth as required as in sunken floor etc complete all as specified and as directed. |
| 26 | M & L for providing 40 mm thick cement concrete (1:2:4) type B-1 using 20 mm graded crushed stone aggregates including integral water proofing compound as per manufacturer's instructions, as in padding in sunken portion of floor slab, coving to junction of floor and vertical walls, including chamfering on edges, finishing the surface fair and even without using extra cement, complete all as specified and directed. Note:- Supply only integral water proofing compound will be measured and paid for separately |
| 27 | M&L for PCC (1:2:4) type B-O using 12.5mm graded stone aggregate as in benching,kerbs and levelling course etc complete all as specified and as directed. |
| 28 | M&L for 40mm thick plain cement concrete 1:2:4 type B-0 using 12.50mm graded stone aggregate as in roof padding, haunching, roof kerb or similar work including 3kg per sqm neat cement slurry complete all as specified as directed. |
| 29 | Use and waste Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter rough finished flat surfaces of concrete complete all as specified and as directed. |
| 30 | Use & waste Formwork to sides and soffits of floor or roof beams, beam haunchings,girders, bressummers,lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified & as directed. |
| 31 | Use & Waste Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified & as directed. |
| 32 | Use & waste Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified & as directed. |
| 33 | Use and waste of Form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished flat surfaces of concrete all as specified and directed. |
| 34 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc, basement slabs, under-reamed piles and mass concrete all as specified and directed. |
| 35 | Material and labour for providing Reinforced Cement Concrete M-25 (Design Mix) as in columns, pillars, piers, posts and struts complete all as specified and directed. |
| 36 | Material and labour for providing Reinforced Cement concrete M-25 (Design Mix) Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specfied and as directed. |
| 37 | Material and labour for providing Reinforced Cement concrete M-25 (Design Mix) as in beams and the like complete all as specfied and as directed. |
| 38 | Material & labour for RCC (1:1.5:3) type A-1, using 20mm graded stone aggregate, as in chajjas, fins, louvers, roof projections, beam and lintel after removing loose concrete and preparation of roof surfaces by application of de-rusting chemical such as Dr fixit rust remover or equivalent and welding additional main bars/ distribution bars if found necessary by inserting to adequate depth in beam by drilling, pinning reinforcement old bars/new with including necessary sacafolding and form work as required upto the height 3.5 mtr, complete all as specified and directed.Note:-1. Rates shall be deemed to include the cost for necessary scafolding etc.2. Reinforcement will measured and paid separately.3. Nitozinc primer (FOSROC or equivalent) @ 200ml per Sqm surface area of concrete will be paid in saparate item. |
| 39 | S & F Mild steel TMT bars 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for columns, hooks ends and binding with Mild steel wire (annealed) not less than 0.90mm dia (or) securing with clips. |
| 40 | Material and labour for TMT steel bars, 8 mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed |
| 41 | S & F Mild steel TMT bars 8mm dia cut to length, bent to shape required as in stirrups, spacers and binders complete all as specified and directed. including cranking, bending spirally for columns, hooks ends and binding with Mild steel wire (annealed) not less than 0.90mm dia (or) securing with clips. |
| 42 | M&L for Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 Complete all as specified and as directed. |
| 43 | M&L for half brick work with sub class 'B' bricks straight or curved on plan to radious built in cement mortar 1:4 all as specified |
| 44 | M & L Polythene film, 150 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50 kg per sq. m complete all as specifed and as directed. |
| 45 | M & L applying one coat of cold bituminous primer (as approved by GE) @0.40ltr/ per sqm over dried up surface of concrete/plastered including cleaning surfaces confirming to IS 3384-1986 complete all as directed by Engineer-in-charge |
| 46 | Supply and laying APP based polymeric membrane 3 mm thick (Minimum), weighting not less than 3.5 kg/Sqm reinforced with polyester non woven fabric (weighting not less than 160 gms/sqm) shall be applied over Bituminious primer as specified above. Application of polymeric membrane shall be by torching application etc as per manufacturer's instructions. The overlaps shall be minium 100 mm on the transverse direction and 75 mm longitudinal direction including one coat of aluminium paint over the APP modified membrane @ 0.11 Kg/Sqm complete all as specified. |
| 47 | Material and labour for Cleaning and preparation of roof/wall (RCC/BRICK/tiles/Cement concrete) surface and made free of dirt, foreign particles, laitance followed by grinding all protrusions to make surface modulated. Thereafter, inspection for cracks on the surface caused by thermal expansion/ contraction and repairing the cracks on the surface caused by thermal machine, filled with Repair Mortar/General purpose Grout in the proportions as recommended by manufacturer, supplying and applying High performance Hybrid Polyurea waterproofing coating spray/hand applied liquid membrane with following specifications:(a) Elongation of range 400% 600%.(b) Tensile strength of 8-12 N/mm2.(c) Crack bridging ability of 3.00-4.00mm.(d) Hardness (Shore ‘A’ ASTM D2240) of range 50-70.The application shall include final base preparation, epoxy primer application in rato 1.1 (resin: hardner) with 100% water dilution and application of Hybrid polyurea in two coats in 6 hrs interval to achieve total min thickness 1 to 1.50mm. The application/ treatment shall be carried out by authorized rep of approved specialist firm/manufacturer.Make- SIKA/FOSROC/AsianPaints/Berger.Note:- The defect liability period of water proofing treatment to RCC roof slab including sunken floor shall be 10 years and the contractor shall be responsible to keep the entire building(s) free From leakage/seepage for a period of 10 years after certified date of Completion. The contractor may obtain a similar guarantee from the specialist firm engaged by him for the purpose. |
| 48 | Water proofing treatment to sunken portion of WCs, bathroom etc. by applying coating of cement slurry mixed with Acrylic based polymer modified cementitious composite compound of make as approved inTechnical instruction 5/ 2003 as detailed hereunder:-(a) Applying 15 mm thick plaster (1:4) in cement sand mortar with integral water proofing compound 2% by weight of cement on floor and wall, finishing the surfaces even and smooth wiithout using extra cement. The surface shall then be cured and allowed to dry.(b) First layer of slurry of cement @ 0.488 Kg/Sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.253 Kg/Sqm. This layer will be allowed to air cure for 4 hrs.(c) Second layer of slurry of cement @ 0.242 Kg/Sqm mixed with Acrylic based polymer modified cementitious composite compound @ 0.126 Kg/Sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours |
| 49 | Supply and fixing as in repair of self-adhesive, rubber modified bituminous sealing tape 100mm wide and 1.5mm thick laminated with an aluminium foil on the upper side used for sealing of leaks and cracks on galvanized / asbestos sheet / concrete roofs, Leaking roof gutters etc as per manufacturer's instructions complete all as specified. (Make:- Sika MultiSeal AP/STP SuperFlashStrip or equivalent) |
| 50 | M & L for repairing of damaged RCC Chajja , fascia, fins, roof projection, Ceiling and balcony railing etc at any height by rendering 10 to 30mm thick in one or two layers as per site requirements in CM 1:3 .making surface even and smooth without uysing extra cement.(Rate of Scaffolding req for repairing work shall be deemed included in this rate.) |
| 51 | M&L for rendering 5mm thick plaster, in cement mortar (1:3) on fair faces of concrete surfaces of soffits of slabs, ceilings, etc. finished fair and even and without using extra cement complete all as specified and as directed. |
| 52 | M & L 10 mm thick rendering in cement mortar 1:3 mixed with water proofing compound @3% by weight of cement finish surface fair and even without using extra cement complete all as specified. |
| 53 | M&L for rendering 10mm thick in cement mortar (1:6) on other than fair surfaces of PCC block / brick masonry wall / concrete surfaces, etc. finished fair and even without using extra cement complete all as specified and as directed. |
| 54 | M & L 15mm thick rendering in cement mortar (1:4) making surface even and smooth without using extra cement complete all as specified. |
| 55 | M&L rendering 15 mm thick cement plaster in two layer each of 10+5 mm thick on fair faces of brick wall or condrete surfaces in CM (1:4) & water proofing compound mixed with second layer @ 3% finished fair and even complete all as specified. ( Note -WPC shall be measured and paid separetly . ) |
| 56 | Supply only Integral water proofing compound. |
| 57 | M&L for non-skid ceramic tiles, coloured, area of tile exceeding 0.11sqm but not exceeding 0.18sqm each, 7 to 8mm thick of superior quality as in floors, etc. and jointed in neat cement slurry and pointed in white cement (mixed with colouring pigment to match the colour of tiles), laid over and including 15mm thick screed bed in CM 1:4 (rate shall be included) complete all as specified and as directed. |
| 58 | M&L of Glazed ceramic coloured tiles in vertical surface size 450mm x 300mm x & ( 6mm to 7mm )mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick screed bed or backing coat in cement mortar 1:4 laying of skirting/dado on walls all as specified and directed. |
| 59 | M&L for 6 mm thick asbestos cement corrugated or semi corrugated sheets as in roofs, walls etc fixed with ‘L’ type or ‘J’ type cranked hook complete all as specified. |
| 60 | Fixing only old asbestos cement corrugated or semi corrugated sheets as in roofs, walls etc fixed with ‘L’ type or ‘J’ type cranked hook complete all as specified. |
| 61 | M&L for 6 mm thick asbestos cement one piece plain angular ridge sheets as in roofs, walls etc fixed with ‘L’ type or ‘J’ type cranked hook complete all as specified and directed. |
| 62 | Supply and fix pre-painted galvatume aluminium zinc coating GI based corrugated/ semi corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 63 | Supply and fix pre-painted galvatume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 64 | Supply and fix 0.50 mm thick corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof , wall etc with grade of zinc coating 120 gm/sqm complete all as specified and directed. |
| 65 | Fixing only old corrugated galvanised steel sheetings with two corrugation side lap fixed with ‘L’ type or ‘J’ type cranked hook bolts, nuts and washers as in roof , wall etc with grade of zinc coating 120 gm/sqm complete all as specified and directed. |
| 66 | Supply and fix 0.63 mm thick plain galvanized mild steel sheeting in ridges hips, valley, gutters, drip and straight flashings (length or girth as fixed) with grade of zinc coating 275 gm/sqm complete all as specified and directed. |
| 67 | Fixing only old 0.63 mm thick plain galvanized mild steel sheeting in ridges hips, valley, gutters, drip and straight flashings (length or girth as fixed) with grade of zinc coating 275 gm/sqm complete all as specified and directed. |
| 68 | S&F mild steel works as in bands, straps, supports or stays for rainwater, framefor fixing of eaves board, ventilating pipes, including bolts, if required: hooks (stay), hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hanging fans; plain angle cleats for securing purlins to wood trusses or rafters, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed. |
| 69 | Supply and fix Steel work in trusses, purlins, posts and the like using tubular/ square hollow sections including special shaped washer etc. complete using ERW or induction butt welded tubes/SHS conforming to IS.1161 - 2014 / IS.4923 - 1997 grade St.-210 complete all as specified and directed. |
| 70 | M&L for 2nd class hard wood 50 mm thick boarding clean sawn as in purlin,rafter etc fixed with nails complete all as specified and directed. |
| 71 | Supply and fix second class hard wood 50 mm thick boarding, wrought, fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and directed. |
| 72 | Supply and fix second class hard wood 20 mm thick boarding,planed one side. fixed with nails in any position (except flooring and skirting) with butt joints complete all as specified and directed. |
| 73 | M & L for 2nd class hard wood in scantling wrought and fixed in position complete all as specified and directed. |
| 74 | M & L for 2nd class hard wood in scantling clean sawn and fixed in position complete all as specified and directed. |
| 75 | M & L for 2nd class fillets square, rectangular or tringular in section clean sawn screwed with nails exc 6 sqcm and not exc 13 sqcm. |
| 76 | M & L for 2nd class fillets square, rectangular or tringular in section clean sawn screwed with nails exc 13 sqcm and n.exc 25 sqcm. |
| 77 | M & L for 2nd class fillets square, rectangular or tringular in section wrought screwed with nails exc 6 sqcm and n.exc 13 sqcm complete all as specified and directed. |
| 78 | M & L for 2nd class fillets square, rectangular or tringular in section wrought screwed with nails exc 13 sqcm and n.exc 25 sqcm complete all as specified and directed. |
| 79 | Supply and fix in repair wire netting of galvanized steel wire 0.71 mm dia and 12 mm mesh fixed with tinned tacks of wire complete all as specified and directed. |
| 80 | Supply and fixing 4 mm thick AC building board fixed to timber frame work with screws as in ceiling complete all as specified and directed.MAKE :- CHARMINAR/EVEREST |
| 81 | Material and labour for second class hard wood plain fillets, square, rectangular and triangular in section, wrought , bull nosed, splayed, chamfered or rounded on one edge or face, sectional area exceeding 6 sqcm but not exceeding 13 sqcm all as specified. |
| 82 | Supply and fix, as in repair, vitreous china squatting pan of Orrisa pattern size 580mm x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection making good to floor all as specified . |
| 83 | Supply & Fix cast iron 'P' trap 100 mm bore complete all as specfied & as directed. |
| 84 | S & F in repairs PVC valveless,syphonic action type,low level PVC flushing cistren 10 ltr cap white with flush pipe &all fitting and flush pipe complete all as specified. |
| 85 | S & F in repair PVC connections 15 mm size with PTMT nuts of length 450 m complete all as specified. |
| 86 | Supply and fixing 50 mm dia spout pipe complete all as specified and directed. |
| 87 | Supply and fixing grating doom PTMT 125 mm dia with waste holes (minimum weight 40 grams) , fixed as in repairs, complete all as specified and directed. |
| 88 | Supply and fixing grating doom PTMT 100mm dia with waste holes (minimum weight 25 grams) , fixed as in repairs, complete all as specified and directed. |
| 89 | Supply & Fixed in repairs PVC (SWR) Pipe 110 mm bore single socketed in any length with rubber ring joints fixed to walls/floor or in trenches complete all as specified and directed. |
| 90 | Supply & Fixed PVC (SWR) Pipe 75 mm bore single socketed in any length with rubber ring joints fixed to walls/floor or in trenches complete all as specified and directed. |
| 91 | Supply & Fixed PVC (SWR) bend 110mm dia suitable for pipe complete all as specified and as directed |
| 92 | Supply & Fixed PVC (SWR) bends 75 mm bore any radius complete all as specified and as directed |
| 93 | Supply & Fixed PVC (SWR) junction single , ( single T) 110 mm bore equal or unequal complete all as specified and as directed |
| 94 | S & F 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores: |
| 95 | S & F 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores: |
| 96 | S & F 25mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, in any length, including supply and fixing all fittings, ISI marked conforming to IS -1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed of the following bores: |
| 97 | Fixing only old 15mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed.Note: Serviceable tubings obtained from dismantling herein before will be reused under this item |
| 98 | Fixing only old 20mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed.Note: Serviceable tubings obtained from dismantling herein before will be reused under this item |
| 99 | Fixing only old 25mm bore steel water tubing, medium grade, galvanised with screwed and socketed joints, including supply and fixing all fittings, ISI marked conforming to IS-1239 and fixed to walls or laid in floors / trenches required for water connections complete all as specified and as directed.Note: Serviceable tubings obtained from dismantling herein before will be reused under this item |
| 100 | Cutting chases, pinning in, making good to facing where required and pointed in cement mortar 1:3 and making good cutting exceeding 10 cm girth complete all as specified. |
| 101 | Supply and fix in repair gun-metal, globe or gate valves with iron wheel head, screwed both ends for 20 mm bore iron pipe all as specified and directed. |
| 102 | Supply and fix in repair gun-metal, globe or gate valves with iron wheel head, screwed both ends for 25 mm bore iron pipe all as specified and directed. |
| 103 | Supplying, hoisting, fixing and connecting up 500 litres capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 104 | Supplying, hoisting, fixing and connecting up 1000 litres capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 105 | Supplying, hoisting, fixing and connecting up 2000 litres capacity rotational moulded polythylene water storage tanks (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part-I including connecting the overflow drain out, inlet and outlet pipes, tank nipple, elbow, bend, unions, sockets, etc. including taking down old damaged water tank and disposing off complete all as specified and as directed |
| 106 | Supply and fixing PVC lid for PVC water storage tanks of capacity 500 litres including PVC hinges and PVC locking both complete all as specified. |
| 107 | Supply and fixing PVC lid for PVC water storage tanks of capacity exc 500 litres and upto 1000 litres including PVC hinges and PVC locking both complete all as specified. |
| 108 | Supply and fixing PVC lid for PVC water storage tanks of capacity 2000 litres including PVC hinges and PVC locking both complete all as specified. |
| 109 | Supply and fix Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) for 20 mm bore pipe complete all as specified and directed . |
| 110 | Supply and fix Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) for 25 mm bore pipe complete all as specified and directed . |
| 111 | S&F in repair PVC ball valve 20mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe with including necessary tank lid all as specified |
| 112 | S&F in repair PVC ball valve 25mm dia high pressure of PTMT with aluminium rod & high density plastic ball screwed for iron pipe with including necessary tank lid all as specified |
| 113 | Cleaning and removing properly of all scale and dirt etc from tanks and mouth of eructing pipe including taking out and refixing of ball valve assembly of 500 litres capacity of tank and Writing fresh date of cleaning including erasing of old date by applying black paint complete all as specified. |
| 114 | Cleaning and removing properly of all scale and dirt etc from tanks and mouth of eructing pipe including taking out and refixing of ball valve assembly of 1000 litres capacity of tank and Writing fresh date of cleaning including erasing of old date by applying black paint complete all as specified. |
| 115 | Cleaning and removing properly of all scale and dirt etc from tanks and mouth of eructing pipe including taking out and refixing of ball valve assembly of 2000 litres capacity of tank and Writing fresh date of cleaning including erasing of old date by applying black paint complete all as specified. |
| 116 | Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position incl Cleaning and removing properly of all scale and dirt etc from tanks and mouth of eructing pipe including taking out and refixing of ball valve assembly of capacity exc. 500 ltr & n.exc. 1000 Ltrs complete all as specified. |
| 117 | M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mm X 600 mm with main runner 38 mm x 24 mm and wall angle 24mm X 24mm using 4mm thick High Pressure steam Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in a grid of GI system duly suspended with 4mm dia GI bar hanger fixed with steel dash fasteners or iron purline from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid all as specified and directed. Make:Everest Industries Ltd or equivalent as per IS 14862. |
| 118 | M&L for cleaning roof, wall and chajja surfaces removing unwanted growth of plant or trees at accessible roof, complete all as specified and directed. |
| 119 | M & L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling complete all as specified and as directed |
| 120 | M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 121 | Material and labour for complete removal of existing treatment and applying two coat of oil bound distemper (white or tinted) over a coat of primer on wall complete all as directed. |
| 122 | Material & Labour for preparation of new or previously untreated wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified. |
| 123 | Material and labour for preparation of new steel surfaces of any description, not otherwise described exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 124 | M&L preparation of new wood or wood base surface of any description over 10cm width or girth applying two coats of synthetic enameled paint over one coat of pink primer complete all as specified. |
| 125 | M&L preparation of new wood or wood base surface of any description n exe 10cm width or girth applying two coats of synthetic enameled paint over one coat of pink primer complete all as specified. Please Enable Macros to View BoQ information |