| 1 | Dismentalling of pump for over hauling including greasing, gland packing, necessary repairs & reinstallation of the same including trail run for 10 hrs. in two spell complete as per direction of the Engineer-in-charge. |
| 2 | Dismentalling of motor for vernishing,heatinf etc . Complete in/c reinstallation of and trail run for 10 hrs. in two spell complete as per direction of the Engineer-in-charge. |
| 3 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of the Engineer-in-charge. A) Circuit Boars for OSCO starter of Backelite make |
| 4 | Repairing of 200 amps main switch including changing necessary spare parts such as H.R.C fuse,gang,guide,feeder,nuts,bolts,etc whichever needed as per direction of the Engineer-in-charge. |
| 5 | Repairing of Busbar box including changing necessary burnt spares and copper strips etc as per direction of the Engineer-in-charge. |
| 6 | Providing & fitting fixing pvc suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.i) 150 mm dia |
| 7 | \\"Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality. (i) 150 mm dia. |
| 8 | Providing and fitting fixing C.I.foot valve spare parts of 125/150 mm dia at site of work of approved quiality. A) CI Foot valve weight . |
| 9 | B) CI Foot valve ring. |
| 10 | C) CI Foot valve net. |
| 11 | \\"Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality. (i) 150 mm dia. |
| 12 | Providing & fitting fixing C.I tail piece of approved quality at site of work.(i) 150 mm dia. |
| 13 | ii) 125 mm dia |
| 14 | Supply & fitting fixing ball bearing of approved quality for pump equired during overhauling.a) 6305(TATA/SKF) |
| 15 | Providing & fitting fixing C.I gland of approved quality. |
| 16 | Providing & fitting fixing Gland Nuts / Stag Nuts 100mm long for gland of approved quality. |
| 17 | Providing & fitting fixing of leather foot valve washer(6mm Thick) of approved quality as per direction of the Engineer-in-charge. (a) 200 mm dia. |
| 18 | Supplying and greasing/ applying of gease of approved quality. |
| 19 | Supplying and fixing Asbestor rope of approved quality. A) 6 to 8 mm thick |
| 20 | b) 10 to 12 mm thick |
| 21 | Providing cupling nuts & bolts(All size) of approved quality. |
| 22 | Providing & fitting fixing coupling rubber bush (all size) of approved quality. |
| 23 | Supplying and fitting fixing of Shaft Sleeve nut of approved quality(Cast Iron). |
| 24 | Supplying and fitting fixing of Shaft gum bush of approved quality. |
| 25 | Supplying and fitting fixing of stack nut for pump of approved quality(in different size). |
| 26 | Providing & fitting fixing Pump Shaft of approved quality. |
| 27 | Supplying and fitting fixing of shaft lock of approved quality. |
| 28 | Providing and fitting fixing of CI coupling complete with nuts and bolts of approved quality a)150 mm |
| 29 | b)190 mm |
| 30 | c) 225 mm |
| 31 | Supplying and fitting fixing of star coupling bush of approved quality a)150 mm |
| 32 | b)190 mm |
| 33 | c) 225 mm |
| 34 | Labour charge for mattaling,turning making alignment of pump motor shaft for suitable fitting coupling bearing sleeve bush etc as per direction of the Engineer-in-charge. |
| 35 | Laboure charge for lifting of hose pipe |
| 36 | Supplying and fitting fixing of spare parts for 20/25 HP Horizontal Motor motor .a)Motor Fan |
| 37 | b)Terminal Plate |
| 38 | Providing and fitting fixing of nuts,bolts with washer of approved quality |
| 39 | Providing and fitting fixing of 40 mm dia following fittings as per direction of the Engineer-in-charge. a) Fullway valve (brass make) |
| 40 | b)Union Joint(GI) |
| 41 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer- in - charge. a)40 mm dia nominal bore. |
| 42 | Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per chapter 20 of CPWD specification & direction of the Engineer - in - charge. i. 125 mm dia. A. PN - 1.0 |
| 43 | ii) 150 mm dia. A. PN - 1.0 |
| 44 | Supplying and fitting fixing of rubber flange washer of approved quality (150 mm dia and 125 mm dia). |
| 45 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN)' 415/500 Volt, complete as per direction of Engineer-in-charge. i) Current range 63 Amps |
| 46 | ii) Current range 200 amps |
| 47 | Providing & fitting fixing of Fully Automatic Star Delta type Motor startar (3ph, 50 Hz, 415V 25HP/18.7 kw Relay range within 17-25) in steel sheet enclosure with Conductor, Timer etc. complete suitable for motor pump Havells/L&T/BCH make as per direction of Engineer-in-charge. |
| 48 | Supplying and fitting fixing of Magnet coil of approved quality. a)63 Amps |
| 49 | b)200 Amps |
| 50 | Suppying and fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pnnel board of approved quality |
| 51 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality. i) SMI - 144, Range 0-400 to 0-500 |
| 52 | Supplying and fitting fixing AC Ammeter(Moving Iron) on the panel board of approved quality. i) SMI - 144, Range 0-10 A. |
| 53 | Providing & fitting fixing of panel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post (Size 50x50x6mm 2.80 Mtr. long) nuts & bolts etc. for errection of the same by 1:1.5:3 cement concrete casting (1 feet x 1 feet x 2 feet) below the ground level and painting two or more coats of synthetic enamel paint on promer as per direction of Engineer-in-Charge. |
| 54 | Providing & fixing 200 Amps busbar of size 600x450x100 mm with 4 nos copper strip of size 450x40x4 mm of approved quality. |
| 55 | Labour for checking of panel board and making good the same including necesary dismantling washing and re-fixing of electrical equipment including detaching existing burned copper wire and connection and making fresh connection take electrical equipment and earthing with 8 S.W.G.G.I wire painting the pannel board with superior ready mixed paint including trial run complete as per direction of the Engineer-in-charge. |
| 56 | Supplying and fitting fixing of selector switch on the panel board of approved quality. |
| 57 | Supplying and fitting fixing of Indicator bulb ( Flush type containing 3 nos batton holder with bulb) on the panel board of approved quality. |
| 58 | Supplying & fitting fixing of kit cut for main & sub-main switch ( Male & Female) as per direction of the Engineer-in-charge.a) 63 amp main switch. |
| 59 | Supplying & fitting fixing of 200 Amps kit cut for main & sub-main switch ( Male & Female).as per direction of the Engineer-in-charge. |
| 60 | Dismentaling of old pump/motor from base & stacking of materials & return the same to Sub-Divisional store as per direction of the Engineer -in-Charge. |
| 61 | Installation of pumpset including carriage of materials from M.I store of Resource Division to site of work including trial run for 10hrs. In two spell |
| 62 | Repairing of impeller by welding, polishing etc complete as per direction of the Engineer-in-charge. |
| 63 | Providing and fitting of M.S flange (8 mm wall thickness) by welding with G.I/M.S pipe and placing position as per specification and the direction of the Engineer-in-charge. a) 150 mm dia |
| 64 | b) 125 mm dia |
| 65 | Suppying & fitting fixing of G.I bend of approved quality.a) 150 mm dia |
| 66 | b) 125 mm dia |
| 67 | Providing and fitting fixing of motor terminal plate for various size of motor (20 HP to 30 HP) as per direction of the Engineer-in-Charge. |
| 68 | Supplying of Transformer oil in the oil tank of maually operated oil immersed starter of approved quality as per direction of the Engineer-in-charge. Please Enable Macros to View BoQ information |