| 1 | Charges for Day to Day Operation and Maintenance of HT and LT side Electrical Installations including 11 KV Dry type Transformer substation ( 1 Nos) with accessories, HT VCB's, 110 Volts DC Charger incl. batteries, Main Control Panels, and 3nos of ACB's, HT & LT cables and their terminations, including the following allied works of various electrical equipments in the sub-station as per scope of work enclosed. a) Foreman Highly skilled |
| 2 | Charges for Day to Day Operation and Maintenance of HT and LT side Electrical Installations including 11 KV Dry type Transformer substation ( 1 Nos) with accessories, HT VCB's, 110 Volts DC Charger incl. batteries, Main Control Panels, and 3nos of ACB's, HT & LT cables and their terminations, including the following allied works of various electrical equipments in the sub-station as per scope of work enclosed. a) Electrician Skilled |
| 3 | Charges for Day to Day Operation and Maintenance of HT and LT side Electrical Installations including 11 KV Dry type Transformer substation ( 1 Nos) with accessories, HT VCB's, 110 Volts DC Charger incl. batteries, Main Control Panels, and 3nos of ACB's, HT & LT cables and their terminations, including the following allied works of various electrical equipments in the sub-station as per scope of work enclosed. a) Electrician Semi skilled |
| 4 | Charges for Day to Day Operation and Maintenance of HT and LT side Electrical Installations including 11 KV Dry type Transformer substation ( 1 Nos) with accessories, HT VCB's, 110 Volts DC Charger incl. batteries, Main Control Panels, and 3nos of ACB's, HT & LT cables and their terminations, including the following allied works of various electrical equipments in the sub-station as per scope of work enclosed. a) Electrician Helper/ Labour, unskilled |
| 5 | Servicing and Testing of 3 nos. of ABB make 11 KV VCB bearing model No. VD4 12.12.25 bearing Sr. Nos. V14070, V14083 and V14069 respectively by authorized agency. |
| 6 | Testing and Calibration of 11 KV VCB of make ABB bearing model No. VD4 12.12.25 and Sr. Nos. V14070, V14083 and V14069 respectively by authorized agency |
| 7 | Servicing of ACB of capacity 800A, 1000A and 1200 A respectively of make ABB by authorized agency. |
| 8 | Servicing and Preventive Maintenance of 11KV /433 V, 400 KVA Transformer, Dry type of Kirloskar make. |
| 9 | Servicing of Fire Engine 3R1040 and Pump DSM 80136 i/c lube oil filters, air filters, engine oil, gaskets and gland packing of pumps, greasing of DE and NDE bearings etc. complete once in 6 months i.e. 2 visits per year. |
| 10 | Overhauling and Servicing of Main Motor 40HP Fire Pump DB 65/26 (1 set) i/c greasing of DE & NDE bearings, replacement of gaskets and gland packings complete as required once in 6 months i.e. 2 visits per year. |
| 11 | Overhauling and Servicing of Jockey Motor 15HP and Pump CPHM 32/26 (1 set) i/c greasing of DE and NDE bearings, replacement of gaskets and gland packing complete etc as required once in 6 months i.e. 2 visits per year. |
| 12 | Rewinding of Single Phase/Three Phase Pump set Motor of various capacities i/c varnishing, heating, cleaning, replacing defective bearings/ capacitors /greasing /painting with grey paint, gaskets/seals of the pump set i/c to & from transportation complete i/c refixing, testing & commissioning without return of old materials. (Warranty to be given atleast for 6 months). a) 1.5HP, 230V, 50Hz AC (1 phase) |
| 13 | Rewinding of Single Phase/Three Phase Pump set Motor of various capacities i/c varnishing, heating, cleaning, replacing defective bearings/ capacitors /greasing /painting with grey paint, gaskets/seals of the pump set i/c to & from transportation complete i/c refixing, testing & commissioning without return of old materials. (Warranty to be given atleast for 6 months). a) 2.0 HP, 230V, 50Hz AC (1 phase) |
| 14 | Rewinding of Single Phase/Three Phase Pumpset Motor of various capacities i/c varnishing, heating, cleaning, replacing defective bearings/ capacitors /greasing /painting with grey paint, gaskets/seals of the pumpset i/c to & fro transportation complete i/c refixing, testing & commissioning without return of old materials. (Warranty to be given atleast for 6 months). a) 5.0HP, 415V, 50Hz AC (3 phase) |
| 15 | Rewinding of Single Phase/Three Phase Pumpset Motor of various capacities i/c varnishing, heating, cleaning, replacing defective bearings/ capacitors /greasing /painting with grey paint, gaskets/seals of the pumpset i/c to & fro transportation complete i/c refixing, testing & commissioning without return of old materials. (Warranty to be given atleast for 6 months). a) 15.0HP, 415V, 50Hz AC (3 phase) |
| 16 | Rewinding of Single Phase/Three Phase Pumpset Motor of various capacities i/c varnishing, heating, cleaning, replacing defective bearings/ capacitors /greasing /painting with grey paint, gaskets/seals of the pumpset i/c to & fro transportation complete i/c refixing, testing & commissioning without return of old materials. (Warranty to be given atleast for 6 months). a) 40.0HP, 415V, 50Hz AC (3 phase) |
| 17 | Providing and fixing following rating and breaking capacity fixed type/adjustible 3 pole MCCB inside the existing cubicle panel board including drilling holes in cubicle panel making connections etc as required;(d) 100 A 35 KA CAT A |
| 18 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 19 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(d) TP Cat A |
| 20 | Supply and fixing of LED Batten 4 feet 20 W with led tube as required of make Panasonic Passolite or equivalent. |
| 21 | Supply of high speed diesel for use in DG sets in Goa Niwas, Chanakyapuri, Delhi. |
| 22 | Transportation of Diesel from Petrol Pump to the site of work at Chanakyapuri, New Delhi. Please Enable Macros to View BoQ information |