| 1 | Wiring for 5A /15A plug with 2 x 4 sq.mm FR PVC insulated copper conductor single core cable in PVC casing capping alongwith 1 No 4 sq.mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 2 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in the independent PVC casing capping of appropriate size as required.;(k) 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm casing ) |
| 3 | Installationearthing testing and commissioning of ceiling fan including wiring the down rod of standard length ( upto 30 cm) with 1.5 sq .mm FRFRLS PVC insulated copper conductor single core cable etc. as required. |
| 4 | Supplying and fixing following way TPN sheet steel double door Verticle type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)interconnection between incomer MCB and busbars of following ways (but without MCBs as required);(a) 4 way (8+12) double door Vertical type Cat A |
| 5 | Supplying and fixing 40 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(e) TPN Cat A |
| 6 | Supplying and fixing 6 A to 32 A C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.;(a) SP Cat A |
| 7 | Supply of 3 core armoured PVC/XLPE insulated PVC sheathed copper conductor cable of 1.1 KV grade with ISI mark conforming to IS:1554(Part I) IS:7098(Part I) with latest amendments of following size.;3 Core 2.5 sq.mm |
| 8 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of size not exceeding 25 sq.mm on surface etc. complete as required |
| 9 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan double ball bearing type complete with all accessories.;(a) Cat A |
| 10 | Supply and fixing of LED Batten 4 feet 20 watt with led tube as required of make Panasonic , Pisolite or equivalent. |
| 11 | Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A C series SP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required\\";(a) Cat A\\" |
| 12 | Supply, installation, testing and commissioning of 36 watts or more LED Street light in Pressure die cast aluminium housing with polycarbonate cover having IP 65 class of protection or above having efficient hight output LED of make Greatwhite bearing cat No.LED-STL-38005, or Jaguar fittings bearing cat NoLSRT01S036XC or Bajaj bearing cat No. BRTFG 36W LED or any approved equivalent make ( to be approved by Engineer in Charge) complete with 40 mm dia GI pipe bend at an appropriate angle of length 80cms and having three years free replacement warranty complete as required. |
| 13 | Supply ,Testing and Commissioning of Cordless type, high wall split type air conditioner of 3.0TR capacity & 3 star rating having in built stablizer,time delay features, Auto start facility, three speed cooling capacity, Oscillating louvers with scroll compressor suitable for operation on single phase 230 volts, 50 Hz A.C. supply of make Bluestar Model IM336AANU1 or equivalent in Daikin/Panasonic/Toshiba/Voltas/Mitsubishi make approved by the Engineer in Charge. |
| 14 | Installation of Mega 3.0 ton inverter split AC |
| 15 | Supply and fixing of Fabricated stand to install 3.0 Ton condening unit with suitable screws etc as required for Split AC. |
| 16 | Extra for core cutting 3\\" dia hole as required at site. |
| 17 | Supply and fixing of refrigerant copper piping of suitable size with insulation as required for split AC. |
| 18 | Electrical cable from indoor to outdoor |
| 19 | Supplying and fixing of PVC drain piping of suitable size as per site of approved make. |
| 20 | Supply Installation Testing and Commissioning of Cordless type, high wall split type air conditioner of 1.0 TR capacity & 5 star rating having in built time delay features, Auto start facility, three speed cooling capacity, Oscillating louvers with scroll compressor suitable for operation on single phase 230 volts, 50 Hz A.C. supply of make Panasonic Model CU/CS-EUI2AKY5 or equivalent in Bluestar/Daikin/Toshiba/Voltas/Mitsubishi make approved by the Engineer in Charge. |
| 21 | Supply and fixing of M.S. stand to install 1/1.5 /2.0 Ton condening unit with suitable screws etc as required for Split AC. |
| 22 | \\"Supply and fixing of 4 KVA automatic voltage stabilizer for 1.5ton ton Air Conditioner unit as required of make Everest/V-Guard\\" Please Enable Macros to View BoQ information |