| 1 | Air conditioning |
| 2 | OD183664/2025-2026:Supply, installation, testing and commissioning of wall mounting type split air conditioner unit conforming to IS fitted with rotary compressor operating on 230V single phase AC supply, R410A /R32 non CFC refrigerant capable of performing functions like cooling, dehumidifying, air circulating, filtering etc of following capacity, microprocessor control with cordless remote control etc 2 Tr 3 star single phase Inverter type split AC unit with copper condensing coil, including Cu pipe connection & electric cabling from indoor to outdoor unit up to 3m comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc. complete. (O General/Daikin/Blue star/Carrier/Mistubishi |
| 3 | OD183665/2025-2026:Supply, fixing & giving connection of 5 KVA voltage stabilizer with voltage range of 175-275V and out put range of 210 - 240V suitable for 2 TR split type A/C unit |
| 4 | OD180721/2025-2026:Supply and providing stand/frame set for the outdoor unit on the wall with necessary screws etc: as required, |
| 5 | OD180718/2025-2026:Supply & drawing drain piping for the condensate drain water to the nearest drain point with 25 mm PVC pipe with nitrile rubber tube insulation. |
| 6 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 7 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 8 | 1.17.23:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.5 x 4 sq. mm |
| 9 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 10 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 11 | 90.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket |
| 12 | 90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator |
| 13 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole Please Enable Macros to View BoQ information |