| 1 | 1. BOUNDARY WALL (L=143.50 m) : Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming o fbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 2 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more.5.22.1 Mild steel and Medium Tensile steel bars |
| 5 | Centering and shuttering inluding strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete.5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. |
| 6 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | 5.9.6 Columns, Pillars, Posts & Strut |
| 8 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 9 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 10 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) |
| 11 | 15 mmthick cement plaster in single coat on rough side of single or half brick wall. 13.5.1. 1:4.(1 Cement : 4 Coarse Sand)c) In cement mortar 1:5 |
| 12 | Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1.Water thinnable cement primer. |
| 13 | Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2 |
| 14 | 2. IRON GATE WITH RCC POST (2 NOS.) :Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming o fbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 15 | Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.(a) Brick on flat soling. |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 17 | Steel reinforcement for R... Work inluding sraitaning, leaning utting and bending to proper shape plaing in position and binding up to plinth level. 5.22.6. TMT bar Fe500D or more.5.22.1 Mild steel and Medium Tensile steel bars(i) TMT Corrosion resistant steel (CRS) reiforcement bar |
| 18 | Centering and shuttering inluding strutting, propping etc end removal of the same...5.9.1. Foundation Footing, base of column etc. For mass concrete.5.9.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. |
| 19 | 5.9.6 Columns, Pillars, Posts & Strut |
| 20 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.3 1:2:4 (1 cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size) |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu-ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 22 | 15 mm cement plaster 1:2 (1 cement : 2 stone dust) on the rough side of single or half brick wall. |
| 23 | Applying one coat of water thinable cement primer of approved brand and manufacture on wall surfaces. 13.43.1.Water thinnable cement primer. |
| 24 | Finishing wall with water proofing cement paint of approved brand and manufacture of required shade. 13.44.1.New work (Two or More coat @ 3.84 Kg/10m2 |
| 25 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 26 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 27 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, |
| 28 | CONSTRUCTION OF GATE :Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 29 | Dry brick pitching half brick thick in drains including supply of bricks and preparing the surface complete :16.12.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 30 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :4.1.5 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 31 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 32 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.5.22A.6 Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete |
| 34 | 5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 35 | 5.9.6 Columns, Pillars, Piers, Abutments, Posts and Struts |
| 36 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :5.1.2 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 37 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 38 | 15 mm cement plaster on rough side of single or half brick wall of mix:13.5.2 1:6 (1 cement: 6 coarse sand) |
| 39 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 40 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 41 | With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works. |
| 42 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture sqm |
| 43 | 3. FURNITURES :King Size Bed Godrej/Other Make |
| 44 | 2 Door Steel Almirah Godrej/Other equivalent Make |
| 45 | Serene Dresser Godrej/Other equivalent Make |
| 46 | Bedside Table Godrej/Other equivalent Make |
| 47 | Sofa (3 + 1 + 1 Seater, Grey) Godrej/Other equivalent Make |
| 48 | 1 Seater Recliner Godrej/Other equivalent Make |
| 49 | Nova 78 x 72 x 5 (Mattress King Bed, Coir, Memory Foam) Godrej/Other equivalent Make |
| 50 | Caliber 202 Computer Table Godrej/Other equivalent Make |
| 51 | 4 Seater Dining Set Dark Wood Godrej/Other equivalent Make |
| 52 | PILLOW |
| 53 | PILLOW COVER |
| 54 | BEDSHEET KING SIZE |
| 55 | DOOR MET |
| 56 | HAND TOWEL |
| 57 | Blanket |
| 58 | Carpet |
| 59 | SONY TV (55 inch) |
| 60 | Samsung 324L Double Door Refrigerator |
| 61 | Table Top Basin(only for vip room+ conference+) |
| 62 | DINNER SET BY BOROSIL |
| 63 | DRINKING GLASS SET BY BOROSIL |
| 64 | GLASS JUG BY BOROSIL |
| 65 | DINING MET |
| 66 | SAUCER SET |
| 67 | CENTER TABLE |
| 68 | 4. EXTERNAL ELECTRIFICATION, TRANSFORMER :Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.2.2.2 125 A, 16 KA, TP MCCB |
| 69 | 2.2.17 250 A, 50KA,FPMCCB |
| 70 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.2.15.3 63 A |
| 71 | Providing and fixing H.T. danger notice plate of 250 mm X 200 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 72 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.1.13. 3 X 95 sq. mm (38mm) |
| 73 | Supplying and making outdoor end termination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.9.2.21 3½ X 95 sq. mm |
| 74 | Supplying and erection of galvanised stay set for 11 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 11 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required |
| 75 | Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 11 KV over head line conductors complete with 50 mm X 50 mm X 6 mm (angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required. |
| 76 | Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required |
| 77 | Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required. |
| 78 | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 KV overhead lines with rated voltage 9 KV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. |
| 79 | Supplying including erection of 12.00 Mtr. G.I. Steel Tubular Pole (410-SP-60) (Stnd.Weight 208 K.g.) along with fitting fixing, excavation work, foundation of bolts and nuts in R.C.C. work in 1:3:6 proportion of 1.80 Mtr. Depth, Cement plastering and etc. complete with all necessary materials as required and specified by the Department.12 Mtr. G.I. Steel Tubular Pole (410-SP-60) |
| 80 | Supplying,installation,testing and commissioning of the 63 KVA 11/0,433KV Aluminium wound outdoor type oil filled (4 Star/ Level-II) Transformer complete including all accessories like Earthing terminal, Lifting Lugs, Drain Valve, Oil filling Hole with plug, Silicigel Breather, First filling of Oil as per IS 355, Arcing Horn, Radiator, Air Release Plug, Conservator Tank etc. along with charging approval of the Sub-Station from the competent authority as directed and specified by the department. Transformer should be as per CEA guideline as ammended up to date.(All require materials for the Sub-Station will be measured & paid separately) (POWER MAKER UNIT -II).63 KVA 11/0,433KV |
| 81 | Supplying Power / Control Copper Cables, Solid Copper conthuctor up to 6 sq. mm balance Stranded,XLPE Insulated, cores laid up,PVC tape inner sheathed for Multicore Cables, Unarmored / Armour ( Glavanised wire for cables up to 10 x1.5 sq.mm, 8 x 2.5 sq,mm, 2 x 10 sq.mm, 3 x 10 sq.mm, 4 x 6 sq.mm balance all galvanized steel strip), extruded PVC Type ST2 Sheathed,650/1100 V grade as per IS 7098 (Part 1) 1988 (Havells, RR, or equivalent make as approved by the Deptt.)2.5 sq.mm 10 Core Copper cable. |
| 82 | Supply of following size PVC/XLPE insulated and PVC sheathed 1.1KV Gd. Solid Aluminum conductor up to 10 sq.mm, balance stranded conductor, XLPE Insulated, core laid up, PVC tape inner sheathed, Armor (Aluminum wire for single core up to 70 sq.mm, balance Aluminum strip, Galvanized wire for cable up to 2 x 10 sq.mm, 4 x 6 sq.mm & balance all galvanized steel strip), extruded PVC Type ST2 sheathed, 650/1100V grad as per IS 7908 (Part-I) 1988 armored U.G. cable as specified and directed by the deptt. (Havells, RR or equivalent make as approved by this Deptt.)A-6.00 sq.mm 2 Core U.G. Cable |
| 83 | B-10.00 sq.mm 2 Core U.G. Cable |
| 84 | C-95.00 sq.mm 3.5 Core U.G. Cable |
| 85 | Supplying with fitting and fixing of 11 KV GOAB Switch 400 Amp. as required and specified by the Department. |
| 86 | Supplying with fitting and fixing of 11 KV D.O. Fuse set 200A Assembly as required and specified by the Department. |
| 87 | Supplying with fitting and fixing of 3-Phase-4W Combined CT/PT Accuracy Class 0.5 400/5A, STC:18.1KA for 1 Sec. as required and specified by the Department. |
| 88 | Supplying with fitting and fixing 11 KV 1C x 70sq.mm AAAC Covered Conductor. |
| 89 | plying with errection of CI Earth pipe 1.8m inner dia 100mm, outer dia 110mm with perforated holes of 15mm dia at 30 cm interval along length of the pipe as required and specified by the Department. |
| 90 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 36kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in an enclosure and necessary connection.160Amp 4P MCCB |
| 91 | 160Amp 4P Manual Changeover Switch |
| 92 | Supplying and fixing double door Vertical TPN Distribution board for MCCB incomer with IP-43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Up to 160A)12WAY VTPN DB Please Enable Macros to View BoQ information |