| 1 | DSR2023-2.8, Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | DSR2023-2.8.1, All kinds of soil For soak pit. |
| 3 | 4.1.8 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | 6.1 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: |
| 5 | 6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 6 | 6.4 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level inall shapes and sizes in : 6.4.2 Cement mortar 1:6 (1 cement : 6 coarse sand) cum 9105.95 |
| 7 | 6.13 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level 6.13.2 Cement mortar 1:4 (1 cement :4 coarse sand) sqm 1123.80 |
| 8 | 5.2 Reinforced cement concrete work in walls (any thickness), includingattached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing andreinforcement :5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived fromnatural sources : 3 graded stone aggregate 20 mm nominalsize derived from natural sources) |
| 9 | 5.22 Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete upto plinth level. |
| 10 | 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D ormore. |
| 11 | 10.25 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steelprimer using structural steel etc. as required. |
| 12 | 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works |
| 13 | 5.9 Centering and shuttering including strutting, propping etc. and removalof form for |
| 14 | 5.9.3 Suspended floors, roofs, landings, balconies and accessplatform |
| 15 | 13.5 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 16 | 13.5.2 1:6 (1 cement: 6 coarse sand) |
| 17 | 13.4 12 mm cement plaster of mix : |
| 18 | 13.4.2 1:6 (1 cement: 6 coarse sand) |
| 19 | 11.38 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete. |
| 20 | 8.31 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 21 | 17.1 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required: |
| 22 | 17.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 23 | 17.23 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm or 340x410x265 mm sizesrespectively. |
| 24 | 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, havingthermal stability for hot & cold water supply and all CPVC plain & brassthreaded fittings, including fixing the pipe with clamps at 1.00 m spacing.This includes jointing of pipes & fittings with one step CPVC solventcement and testing of joints complete as per direction of Engineer inCharge. |
| 25 | 18.7.1 15 mm nominal dia Pipes |
| 26 | 18.7.3 25 mm nominal dia Pipes |
| 27 | 18.7.4 32 mm nominal dia Pipes |
| 28 | 12.41 Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A, including jointing with seal ringconforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)Single socketed pipes. |
| 29 | 12.41.2 110 mm diameter |
| 30 | 18.15 Providing and fixing brass bib cock of approved quality |
| 31 | 18.151 15 mm nominal bore |
| 32 | 13.80 Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete. |
| 33 | 13.46 Finishing walls with Acrylic Smooth exterior paint of required shade :13.461 New work (Two or more coat applied @ 1.67 Itr/10 sqm overand including priming coat of exterior primer applied @ 0.90litre/10 sqm) |
| 34 | 13.83.2 Wall painting with premium acrylic emulsion paint of interior grade, havingVOC (Volatile Organic Compound ) content less than 50 grams/ litre ofapproved brand and manufacture, including applying additional coatswherever required to achieve even shade and colour.Two coats |
| 35 | 13.62 Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade :13.621 Two or more coats on new work over an under coat of suitableshade with ordinary paint of approved brand and manufacture |
| 36 | 18.48 Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, IS : 12701 marked, with cover and suitable lockingarrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 37 | supply and laying 40mm gauge over burnt brick ballast including all material and labour and T&P for proper completion of work as per DSR no 0287 |
| 38 | providing and laying in C C 1:2:4 nominal size of aggregater of 40mm and curing compltete , including cost of form work , in foundation and floors as per DSR 4.1.4 |
| 39 | Submersible & boring |
| 40 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A for Light as per DSR 1.10.1 |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B for Fan as per DSR 1.10.2 |
| 42 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch as per DSR 1.24.1 |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 6 pin 15/16 A socket outlet as per DSR 1.24.5 |
| 44 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.4 Module (125mmX75mm).DSR NO.1.27.3 |
| 45 | Supplying & fixing suitable size Gl box with modular plate and cover in fronton surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. as per DSR 1.57 |
| 46 | LED batten light supplying installation testing & commosioning of LED surface mounted batten light of folowing body material and theconstruction as per IS 10322 with driver , oprating voltage AC 140 volt feq 50/60 hz , 24-26 watt as per DSR2025 8.9.2 Please Enable Macros to View BoQ information |