| 1 | CIVIL WORK- DHARMA PATHEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 2 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 3 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete. |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 6 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 7 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 8 | Suspended floors, roofs, landings, balconies and accessplatform |
| 9 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 10 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cementconcrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. |
| 11 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 12 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 13 | Supply and Fixing Hand Rail and Bulustrade modular system passive SS-304 decorative Railing 900 mm th. |
| 14 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. Granite stone colour black, Cherry/Ruby red. |
| 15 | Supply and fixing of Glass Fiber Reinforced Concrete (G.F.R.C) Elements in approved size, pattern, design, thickness 35- 40 mm for External work and color of M/S Terra Firma make . The GRC element should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain OCV , Neg Japan or equivalent, Super Plasticizers manufactured by ‘BASF’ , Nerolac Perma or equivalent, Polymers manufactured by ‘BASF’, Nerolac Perma or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of GFRC Element work with Dry Fixing method using fasteners, and necessary hardware etc in Building Facade complete as per directed by Engineer-in- Charge) |
| 16 | Supply and fixing of Glass Fiber Reinforced Concrete (G.F.R.C) Elements in approved size, pattern, design, thickness 35- 40 mm for External work and color of M/S Terra Firma make . The GRC element should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain OCV , Neg Japan or equivalent, Super Plasticizers manufactured by ‘BASF’ , Nerolac Perma or equivalent, Polymers manufactured by ‘BASF’, Nerolac Perma or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of GFRC Element work with Dry Fixing method using fasteners, and necessary hardware etc in Building Facade complete as per directed by Engineer-in- Charge) |
| 17 | CIVIL WORK- SHAKTI PATHEarth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. |
| 18 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m. |
| 19 | Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming consolidating and dressing complete. |
| 20 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete |
| 22 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 23 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 24 | Suspended floors, roofs, landings, balconies and accessplatform |
| 25 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level |
| 26 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cementconcrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge.Note:- Cement content considered in this item is @ 330 kg/ cum. Excess or less cement used as per design mix is payable or recoverable separately. |
| 27 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 28 | 15 mm cement plaster on rough side of single or half brick wall of mix: |
| 29 | Supply and Fixing Hand Rail and Bulustrade modular system passive SS-304 decorative Railing 900 mm th. |
| 30 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cementmortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. completeat all levels. Granite stone colour black, Cherry/Ruby red. |
| 31 | Supply and fixing of Glass Fiber Reinforced Concrete (G.F.R.C) Elements in approved size, pattern, design, thickness 35- 40 mm for External work and color of M/S Terra Firma make . The GRC element should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain OCV , Neg Japan or equivalent, Super Plasticizers manufactured by ‘BASF’ , Nerolac Perma or equivalent, Polymers manufactured by ‘BASF’, Nerolac Perma or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of GFRC Element work with Dry Fixing method using fasteners, and necessary hardware etc in Building Facade complete as per directed by Engineer-in- Charge) |
| 32 | Supply and fixing of Glass Fiber Reinforced Concrete (G.F.R.C) Elements in approved size, pattern, design, thickness 35- 40 mm for External work and color of M/S Terra Firma make . The GRC element should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘Saint Gobain OCV , Neg Japan or equivalent, Super Plasticizers manufactured by ‘BASF’ , Nerolac Perma or equivalent, Polymers manufactured by ‘BASF’, Nerolac Perma or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Mould manufactured by ‘Reckli’ or equivalent. The fixing of GFRC Element work with Dry Fixing method using fasteners, and necessary hardware etc in Building Facade complete as per directed by Engineer-in- Charge) |
| 33 | ELECTRICAL WORKS- DHARMA PATHWiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed steelconduit as required..... 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 34 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed mediumclass PVC conduit as required.... 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 35 | Providing and fixing following capacity TP&N disconnector fuse switch unit insidethe existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required... 63ATP&N |
| 36 | Supplying and fixing following rating, double pole, 240 V, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 37 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing MCB DB completewith connections, testing and commissioning etc. as required. SINGLE POLE |
| 38 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A240 V \\"C\\" curve DP MCB complete with connections, testing and commissioningetc. as required. |
| 39 | Supply, Instalation and Testing and commissining of BEAMER Façade Light 15W IP65 Warm White | Outdoor LED Wall Washer for Home, Garden & Building Exterior | Waterproof Architectural Wall Light. |
| 40 | Supply, Instalation and Testing and commissining of LED Cool White 15 Watt Wallwasher Inground Outdoor Light, AluminiumVasai. |
| 41 | ELECTRICAL WORKS- SHAKTI PATHWiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed steelconduit as required..... 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 42 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes ofFRLS PVC insulated copper conductor, single core cable in surface/ recessed mediumclass PVC conduit as required.... 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 43 | Providing and fixing following capacity TP&N disconnector fuse switch unit insidethe existing panel board with lSI marked HRC fuses including drilling holes in cubiclepanel, making connections, etc. as required... 63ATP&N |
| 44 | Supplying and fixing following rating, double pole, 240 V, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 45 | 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuitbreaker suitable for inductive load of following poles in the existing MCB DB completewith connections, testing and commissioning etc. as required. SINGLE POLE |
| 46 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A240 V \\"C\\" curve DP MCB complete with connections, testing and commissioningetc. as required. |
| 47 | Supply, Instalation and Testing and commissining of BEAMER Façade Light 15W IP65 Warm White | Outdoor LED Wall Washer for Home, Garden & Building Exterior | Waterproof Architectural Wall Light. |
| 48 | Supply, Instalation and Testing and commissining of LED Cool White 15 Watt Wallwasher Inground Outdoor Light, AluminiumVasai. |
| 49 | GST Please Enable Macros to View BoQ information |