Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #55427213

Tender For Maintenance Of E/M Misc Items In The Aor Of Age E/M Under Ge Khumbathang

Issued by Statutory Bodies & Commissions/Committees · kumbathang, Jammu And Kashmir
Tender Value
Ref. Documents
Estimated cost
Bid Submission
29 May 2026
0 days left
EMD
80000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
kumbathang → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Maintenance Of E/M Misc Items In The Aor Of Age E/M Under Ge Khumbathang- 1 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 630 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 2 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 800 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. Complete All As Directed By Engr-In-Charge. 3 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity1000 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 4 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 1000 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete Switch All As Directed By Engr-In-Charge. 5 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 1000 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 800 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 800 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 630 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 630 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 400 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 400 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 12 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 200 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 13 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 200 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 14 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 100 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 15 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 100 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 16 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 63 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 17 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 63 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 18 M & L For Changing The Locking Arrangement And Refixing The Doors Of Lt Panels By Welding Nut, Bolts And Washer Etc And Prepare The Outer And Inner Surface Of Panel For Painting And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed 19 Disconnecting From Circuit/Bus Bar Lt Panel And Taking Out Cables For Extension Of Loop/Passing Through Pipe Reconnection With Circuit And Tightening Of Connections By Using Suitable Size Of Lugs/Thimbles Complete All As Specified And Directed 20 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 1000 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 21 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 800 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 22 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 630 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 23 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 400 Amps Breaking Capacity 36 Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 24 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 250 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge 25 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 200 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 26 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 125 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 27 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 100 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 28 Supply And Fix Thimble Aluminium Eye Type Suitable For Upto 25 Sqmm Including Necessary Crimping With Crimping Tool Complete All As Specified And Directed. 29 All As Per Item No 28 But Of Size Upto 35 Sqmm . 30 All As Per Item No 28 But Of Size Upto 50 Sqmm. 31 All As Per Item No 28 But Of Size Upto 70 Sqmm. 32 All As Per Item No 28 But Of Size Upto 95 Sqmm. 33 All As Per Item No 28 But Of Size Upto 120 Sqmm. 34 All As Per Item No 28 But Of Size Upto 150 Sqmm. 35 All As Per Item No 28 But Of Size Upto 185 Sqmm. 36 All As Per Item No 28 But Of Size Upto 240 Sqmm. 37 All As Per Item No 28 But Of Size Upto 300 Sqmm. 38 All As Per Item No 28 But Of Size Upto 400 Sqmm. 39 Supply And Fixing In Repair Lt Line Separator Suitable For Three Phase Four Wire Water Proof, Weather Proof, Shock Proof, Resistant To Chemicals , Robust Construction Easy To Install Low Maintenance And Fine Uniform Finish All As Directed By Engr-In-Charge. 40 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5 M In Depth And Getting It Out For Laying Of Cable / Pole Etc In Hard/Dense Soil 41 Returning, Filling In, Including Spreading, Leveling Watering, And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil All As Directed. 42 Removing Excavated Material N.Exc 50M And Depositing Where Directed At A Level Exc. 1.5 Cm Above The Starting Point All As Directed. 43 Supplying And Laying Double Walled Corrugated Hdpe Pipes Of Size 110 Mm Dia As Per Is 16205 Anti Termite, Anti Rodency And Non Flame Propagation Propety Etc For Protection Of Ht Cables Complete All As Specified And Directed 44 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 120 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 45 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 150 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 46 M&L For Painting Of Lt/Security Light Steel Tubular Pole Upto 9 Mtr Length Incl Ms Clamp , Bracket, Cross Arms And Metallic Junction Boxe With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed 47 M&L For Painting Of Steel Tubular Pole Upto 11 Mtr Length Incl Ms Clamp , Bracket, Cross Arms With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed. 48 Supply Installing, Testing And Commissioning Of Lt Panel Of Size 1.8 X 1.5 X 0.5 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Lt Panel Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. The Panels Shall Be Of Cpri Approved Note:- Drg Of Panel Shall Got Approved Before Execution At Site. Incommer Incoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icuindicator Lamp-01 Set (Set Of Three)Voltmeter 0-500 Volt , 415V , 50 Hz ,With Selector Switches -01 Setammeter 0- 500 Amps With Cts, 415V 50 Hz With Selector Switches -01 Setoutgoingmccb, 415V, 4 Pole, 200 Amps, 25 Ka -01 Nomccb 4 Pole 125 Amp, 415V, 36 Ka, 4 Pole , 02 Nos Mccb 4 Pole 63 Amp, 415V, 36 Ka, 4 Pole , 01 Nos Mcb Spn 40 Amps , 230V, 50 Hz - 01 Nos 49 Supply Installing, Testing And Commissioning Of Bus Bar Junction Box Panel Of Size 0.75 X 0.6 X 0.3 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Bus Bar Junction Box Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. Note:- Drg Of Bus Bar Junction Box Panel Shall Got Approved Before Execution At Site. Incommer/Out Goingincoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icu -01 Nosindicator Lamp-01 Set (Set Of Three) E Tc

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 22-May-2026 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 29-May-2026

BOQ

Name of Work:- MAINTENANCE OF E/M MISC ITEMS IN THE AOR OF AGE E/M UNDER GE KHUMBATHANG
Sl. No. Item Description
1Supply and fix in replcement Air Circuit Breaker 4 Pole 415 Volts Manual drawout type with microprocessor release of capacity 630 Amps incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc.complete all as directed by Engr-in-Charge.
2Supply and fix in replcement Air Circuit Breaker 4 Pole 415 Volts Manual drawout type with microprocessor release of capacity 800 Amps incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. complete all as directed by Engr-in-Charge.
3Supply and fix in replcement Air Circuit Breaker 4 Pole 415 Volts Manual drawout type with microprocessor release of capacity1000 Amps incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc.complete all as directed by Engr-in-Charge.
4S&F in replacement of existing unserviceable On load changeover switch of any size & capacity with On load changeover switch 4 pole 1000 Amps Front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing complete switch all as directed by Engr-in-Charge.
5S&F in replacement of existing unserviceable Off load changeover switch of any size & capacity with Off load changeover switch 4 pole 1000 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing complete all as directed by Engr-in-Charge.
6S&F in replacement of existing unserviceable On load changeover switch of any size & capacity with On load changeover switch 4 pole 800 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
7S&F in replacement of existing unserviceable Off load changeover switch of any size & capacity with Off load changeover switch 4 pole 800 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
8S&F in replacement of existing unserviceable On load changeover switch any size & capacity with On load changeover switch 4 pole 630 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
9S&F in replacement of existing unserviceable Off load changeover switch any size & capacity with Off load changeover switch 4 pole 630 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
10S&F in replacement of existing unserviceable On load changeover switch any size & capacity with On load changeover switch 4 pole 400 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
11S&F in replacement of existing unserviceable Off load changeover switch any size & capacity with Off load changeover switch 4 pole 400 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
12S&F in replacement of existing unserviceable On load changeover switch any size & capacity with On load changeover switch 4 pole 200 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
13S&F in replacement of existing unserviceable Off load changeover switch any size & capacity with Off load changeover switch 4 pole 200 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
14S&F in replacement of existing unserviceable On load changeover switch any size & capacity with On load changeover switch 4 pole 100 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
15S&F in replacement of existing unserviceable Off load changeover switch any size & capacity with Off load changeover switch 4 pole 100 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
16S&F in replacement of existing unserviceable On load changeover switch any size & capacity with On load changeover switch 4 pole 63 Amps front handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
17S&F in replacement of existing unserviceable Off load changeover switch any size & capacity with Off load changeover switch 4 pole 63 Amps Side handle operated along with SS enclosure including minor addition/alternation as required at site for fixing and connecting the changeover switch all as directed by Engr-in-Charge.
18M & L for changing the locking arrangement and refixing the doors of LT panels by welding Nut, bolts and washer etc and prepare the outer and inner surface of panel for painting and applying one coat of synthetic enamel paint complete all as specified and directed
19Disconnecting from circuit/bus bar LT panel and taking out cables for extension of loop/passing through pipe reconnection with circuit and tightening of connections by using suitable size of lugs/thimbles complete all as specified and directed
20S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole, 415 Volt , adjutable type, 1000 Amps breaking capacity 50KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
21S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole, 415 Volt , adjutable type, 800 Amps breaking capacity 50KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
22S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole, 415 Volt , adjutable type, 630 Amps breaking capacity 50KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
23S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole, 415 Volt , adjutable type, 400 Amps breaking capacity 36 KA Thermal magnetic and Microprocessor release with thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
24S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 415 Volt , adjutable type, 250 Amps breaking capacity 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge
25S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 415 Volt , adjutable type, 200 Amps breaking capacity 36 KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
26S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 125 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
27S&F in replacement of existing unserviceable MCCB any size/capacity with MCCB 4 pole 100 Amps 16KA Thermal magnetic setting type incl providing suitable thimbles/extended terminal with nuts,bolts and washers etc. all as directed by Engr-in-Charge.
28Supply and Fix Thimble aluminium eye type suitable for upto 25 sqmm including necessary crimping with crimping tool complete all as specified and directed.
29All as per item No 28 but of size upto 35 Sqmm .
30All as per item No 28 but of size upto 50 Sqmm.
31All as per item No 28 but of size upto 70 Sqmm.
32All as per item No 28 but of size upto 95 Sqmm.
33All as per item No 28 but of size upto 120 Sqmm.
34All as per item No 28 but of size upto 150 Sqmm.
35All as per item No 28 but of size upto 185 Sqmm.
36All as per item No 28 but of size upto 240 Sqmm.
37All as per item No 28 but of size upto 300 Sqmm.
38All as per item No 28 but of size upto 400 Sqmm.
39Supply and fixing in repair LT line separator suitable for three phase four wire water proof, weather proof, shock proof, Resistant to chemicals , robust construction easy to install low maintenance and fine uniform finish all as directed by Engr-in-charge.
40Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil
41Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed.
42Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed.
43Supplying and laying double walled corrugated HDPE Pipes of size 110 mm dia as per IS 16205 Anti termite, Anti Rodency and Non flame propagation propety etc for protection of HT cables complete all as specified and directed
44Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power heavy duty 1100 Volt grade with stranded aluminium conductor of size 120 Sq mm 3.5 core complete all as specified and directed by Engr-in-Charge.
45Supply and laying in replacement XLPE insulated screened PVC bedded galvanised steel strip armoured electric power heavy duty 1100 Volt grade with stranded aluminium conductor of size 150 Sq mm 3.5 core complete all as specified and directed by Engr-in-Charge.
46M&L for painting of LT/security light steel tubular pole upto 9 mtr length incl MS clamp , bracket, cross arms and metallic junction boxe with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed
47M&L for painting of steel tubular pole upto 11 mtr length incl MS clamp , bracket, cross arms with two coat of alumnium paint after preparation of old painted surface and applying metallic primer , providing 03 nos alternative strip of 30 cm wide with black and yellow super quality enamel paint above embedded level and writing pole nos with 02 inch wide letter complete all as specified and directed.
48Supply installing, testing and commissioning of LT Panel of Size 1.8 x 1.5 x 0.5 Mtr outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 800 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- LT panel shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item. The panels shall be of CPRI approved Note:- Drg of panel shall got approved before execution at site. INCOMMER Incoming MCCB, 415V, 4 pole, 400 Amps, 36 KA, Ics =100% IcuIndicator Lamp-01 Set (Set of three)Voltmeter 0-500 Volt , 415V , 50 Hz ,with selector switches -01 setAmmeter 0- 500 Amps with CTs, 415V 50 Hz with selector switches -01 setOUTGOINGMCCB, 415V, 4 pole, 200 Amps, 25 KA -01 NoMCCB 4 pole 125 amp, 415V, 36 KA, 4 pole , 02 Nos MCCB 4 pole 63 amp, 415V, 36 KA, 4 pole , 01 Nos MCB SPN 40 Amps , 230V, 50 Hz - 01 Nos
49Supply installing, testing and commissioning of Bus bar junction box panel of Size 0.75 x 0.6 x 0.3 Mtr outdoor kiosk type factory made of angle iron 65mmx 65mmx 6mm on all side welded to 3.15 mm thick CRCA sheet steel for outer compartment and 2.0 mm thick for inner compartment with openable shutteron both sides ( front and rear) , having locking arrangement totally enclosed weather proof outdoor spray painted internally and externally with two coats of synthetic enamel paint over a coat of primer suitable for 440 volts, 3 phase, 4 wire, 50 Hz with Aluminium bas bar of capacity 800 Amps AC supply, electrically connected as per norms and fitted with following accessories all as specified and directed by the Engr-in Charge. (Note:- Bus bar junction box shall be mounted on PCC 1:2:4 type B-1 with 20 mm graded stone aggregate foundation block of suitable size upto 40 cm above ground level as directed. The cost of the PCC block shall be deemed to be included in the unit rate quoted for the item. Note:- Drg of bus bar junction box panel shall got approved before execution at site. INCOMMER/OUT GOINGIncoming MCCB, 415V, 4 pole, 400 Amps, 36 KA, Ics =100% Icu -01 nosIndicator Lamp-01 Set (Set of three)
50M&L for Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
51Deduct Credit for Demolished/Dismantled material Rs (-) 67,120.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule)Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55427213
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 29-05-2026
Authority
Authority Name Military Engineer Services
Work Description Tender For Maintenance Of E/M Misc Items In The Aor Of Age E/M Under Ge Khumbathang- 1 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 630 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 2 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity 800 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. Complete All As Directed By Engr-In-Charge. 3 Supply And Fix In Replcement Air Circuit Breaker 4 Pole 415 Volts Manual Drawout Type With Microprocessor Release Of Capacity1000 Amps Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc.Complete All As Directed By Engr-In-Charge. 4 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 1000 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete Switch All As Directed By Engr-In-Charge. 5 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 1000 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing Complete All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Of Any Size & Capacity With On Load Changeover Switch 4 Pole 800 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Of Any Size & Capacity With Off Load Changeover Switch 4 Pole 800 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 630 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 630 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 400 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 400 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 12 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 200 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 13 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 200 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 14 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 100 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 15 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 100 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 16 S&F In Replacement Of Existing Unserviceable On Load Changeover Switch Any Size & Capacity With On Load Changeover Switch 4 Pole 63 Amps Front Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 17 S&F In Replacement Of Existing Unserviceable Off Load Changeover Switch Any Size & Capacity With Off Load Changeover Switch 4 Pole 63 Amps Side Handle Operated Along With Ss Enclosure Including Minor Addition/Alternation As Required At Site For Fixing And Connecting The Changeover Switch All As Directed By Engr-In-Charge. 18 M & L For Changing The Locking Arrangement And Refixing The Doors Of Lt Panels By Welding Nut, Bolts And Washer Etc And Prepare The Outer And Inner Surface Of Panel For Painting And Applying One Coat Of Synthetic Enamel Paint Complete All As Specified And Directed 19 Disconnecting From Circuit/Bus Bar Lt Panel And Taking Out Cables For Extension Of Loop/Passing Through Pipe Reconnection With Circuit And Tightening Of Connections By Using Suitable Size Of Lugs/Thimbles Complete All As Specified And Directed 20 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 1000 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 21 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 800 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 22 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 630 Amps Breaking Capacity 50Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 23 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole, 415 Volt , Adjutable Type, 400 Amps Breaking Capacity 36 Ka Thermal Magnetic And Microprocessor Release With Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 24 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 250 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge 25 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 415 Volt , Adjutable Type, 200 Amps Breaking Capacity 36 Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 26 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 125 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 27 S&F In Replacement Of Existing Unserviceable Mccb Any Size/Capacity With Mccb 4 Pole 100 Amps 16Ka Thermal Magnetic Setting Type Incl Providing Suitable Thimbles/Extended Terminal With Nuts,Bolts And Washers Etc. All As Directed By Engr-In-Charge. 28 Supply And Fix Thimble Aluminium Eye Type Suitable For Upto 25 Sqmm Including Necessary Crimping With Crimping Tool Complete All As Specified And Directed. 29 All As Per Item No 28 But Of Size Upto 35 Sqmm . 30 All As Per Item No 28 But Of Size Upto 50 Sqmm. 31 All As Per Item No 28 But Of Size Upto 70 Sqmm. 32 All As Per Item No 28 But Of Size Upto 95 Sqmm. 33 All As Per Item No 28 But Of Size Upto 120 Sqmm. 34 All As Per Item No 28 But Of Size Upto 150 Sqmm. 35 All As Per Item No 28 But Of Size Upto 185 Sqmm. 36 All As Per Item No 28 But Of Size Upto 240 Sqmm. 37 All As Per Item No 28 But Of Size Upto 300 Sqmm. 38 All As Per Item No 28 But Of Size Upto 400 Sqmm. 39 Supply And Fixing In Repair Lt Line Separator Suitable For Three Phase Four Wire Water Proof, Weather Proof, Shock Proof, Resistant To Chemicals , Robust Construction Easy To Install Low Maintenance And Fine Uniform Finish All As Directed By Engr-In-Charge. 40 Excavation In Trenches Not Exc 1.5 M Wide And Not Exc 1.5 M In Depth And Getting It Out For Laying Of Cable / Pole Etc In Hard/Dense Soil 41 Returning, Filling In, Including Spreading, Leveling Watering, And Well Ramming In Layers Not Exc 25 Cm In Hard/Dense Soil All As Directed. 42 Removing Excavated Material N.Exc 50M And Depositing Where Directed At A Level Exc. 1.5 Cm Above The Starting Point All As Directed. 43 Supplying And Laying Double Walled Corrugated Hdpe Pipes Of Size 110 Mm Dia As Per Is 16205 Anti Termite, Anti Rodency And Non Flame Propagation Propety Etc For Protection Of Ht Cables Complete All As Specified And Directed 44 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 120 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 45 Supply And Laying In Replacement Xlpe Insulated Screened Pvc Bedded Galvanised Steel Strip Armoured Electric Power Heavy Duty 1100 Volt Grade With Stranded Aluminium Conductor Of Size 150 Sq Mm 3.5 Core Complete All As Specified And Directed By Engr-In-Charge. 46 M&L For Painting Of Lt/Security Light Steel Tubular Pole Upto 9 Mtr Length Incl Ms Clamp , Bracket, Cross Arms And Metallic Junction Boxe With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed 47 M&L For Painting Of Steel Tubular Pole Upto 11 Mtr Length Incl Ms Clamp , Bracket, Cross Arms With Two Coat Of Alumnium Paint After Preparation Of Old Painted Surface And Applying Metallic Primer , Providing 03 Nos Alternative Strip Of 30 Cm Wide With Black And Yellow Super Quality Enamel Paint Above Embedded Level And Writing Pole Nos With 02 Inch Wide Letter Complete All As Specified And Directed. 48 Supply Installing, Testing And Commissioning Of Lt Panel Of Size 1.8 X 1.5 X 0.5 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Lt Panel Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. The Panels Shall Be Of Cpri Approved Note:- Drg Of Panel Shall Got Approved Before Execution At Site. Incommer Incoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icuindicator Lamp-01 Set (Set Of Three)Voltmeter 0-500 Volt , 415V , 50 Hz ,With Selector Switches -01 Setammeter 0- 500 Amps With Cts, 415V 50 Hz With Selector Switches -01 Setoutgoingmccb, 415V, 4 Pole, 200 Amps, 25 Ka -01 Nomccb 4 Pole 125 Amp, 415V, 36 Ka, 4 Pole , 02 Nos Mccb 4 Pole 63 Amp, 415V, 36 Ka, 4 Pole , 01 Nos Mcb Spn 40 Amps , 230V, 50 Hz - 01 Nos 49 Supply Installing, Testing And Commissioning Of Bus Bar Junction Box Panel Of Size 0.75 X 0.6 X 0.3 Mtr Outdoor Kiosk Type Factory Made Of Angle Iron 65Mmx 65Mmx 6Mm On All Side Welded To 3.15 Mm Thick Crca Sheet Steel For Outer Compartment And 2.0 Mm Thick For Inner Compartment With Openable Shutteron Both Sides ( Front And Rear) , Having Locking Arrangement Totally Enclosed Weather Proof Outdoor Spray Painted Internally And Externally With Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Suitable For 440 Volts, 3 Phase, 4 Wire, 50 Hz With Aluminium Bas Bar Of Capacity 800 Amps Ac Supply, Electrically Connected As Per Norms And Fitted With Following Accessories All As Specified And Directed By The Engr-In Charge. (Note:- Bus Bar Junction Box Shall Be Mounted On Pcc 1:2:4 Type B-1 With 20 Mm Graded Stone Aggregate Foundation Block Of Suitable Size Upto 40 Cm Above Ground Level As Directed. The Cost Of The Pcc Block Shall Be Deemed To Be Included In The Unit Rate Quoted For The Item. Note:- Drg Of Bus Bar Junction Box Panel Shall Got Approved Before Execution At Site. Incommer/Out Goingincoming Mccb, 415V, 4 Pole, 400 Amps, 36 Ka, Ics =100% Icu -01 Nosindicator Lamp-01 Set (Set Of Three) E Tc
Basic Detail
Tender No GE/KHU-106/2025-26
Bidding Type Tender
Location
City kumbathang
State Jammu And Kashmir
Key Dates
Publish Date 22 May 2026
Submission Date 29 May 2026
Open Date 30 May 2026
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 80000
Exemption Not Available
Document List
747e45a9-9908-42a2-a68a-ee57e1424124.html
BOQ_856113.xls
TENDER106.pdf
Tendernotice_1 (1).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 22, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 29, 2026
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
May 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

747e45a9-9908-42a2-a68a-ee57e1424124.html

xls

BOQ_856113.xls

pdf

TENDER106.pdf

pdf

Tendernotice_1 (1).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender