| 1 | (A) S.H. REINFORCED CEMENT CONCRETE WORK Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto floor five level excluding the cost of centring, shuttering, finishing and reinforcement- (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size) |
| 2 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement- (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size ) |
| 3 | Reinforced cement concrete work in vertical and horizontal fins individually or forming box louvers, facias and eaves boards above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with (i) 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size). |
| 4 | Centering shuttering including struttings, propping etc. and removal of form work for: (i) Suspended floors, roofs, landings, balconies and access platform with 12 mm thick shuttering ply |
| 5 | ii) Lintels, beams, plinth beams, girders, bressumers and cantilevers with shuttering ply |
| 6 | iii) Columns, Pillars, Piers, Abutments, Posts and Struts with shuttering ply |
| 7 | iv) Stairs (excluding landings) except spiral-staircases with wooden plank |
| 8 | v) Vertical and horizontal fins individually or forming box louvers band, facias and eaves boards |
| 9 | vi) Weather shade, Chajjas, corbels etc., including edges. |
| 10 | vii) Edges of slabs and breaks in floors and walls above 20 cm. wide |
| 11 | Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. (i) Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Providing precast cement concrete Jali 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate 6mm nominal size) reinforced with 1.6 mm dia mild steel wire including centring and shuttering, roughening cleaning, fixing and finishing in cement mortar 1:3(1cement : 3 fine sand) etc. complete, excluding the plastering of jambs, sills and soffits (i) 40 mm thick |
| 13 | (B) S.H. BRICK WORK First class brick work in superstructure above plinth level & upto floor-five level including cost of all materials as required complete:- (i) In cement mortar 1:6 ( 1 cement : 6 fine sand ). |
| 14 | Half brick masonry work with first class bricks in superstructure upto floor five level including cost of all materials as required complete:- (i) In cement mortar 1:4 ( 1 cement : 4 fine sand ). |
| 15 | (C) STEEL, WOOD & PVC WORK Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer. (i) Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10 cm of 1:3:6 (1 cement : 3 river sand : 6 graded stone aggregate 20 mm nominal size) |
| 16 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. (i)35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 17 | Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veeners on both faces of shutters. (i)35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 18 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, & with cleats with bolts & nuts, rivets, locking arrangement, handles, hooks & eyes, pinlets including embedding in cement concrete of required grade for fixing in position, all necessary fittings, including applying a priming coat of approved steel primer etc. complete as required:-Using M.S. angels 40x40x6 mm for diagonal braces. |
| 19 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS : 1285, fixing with dash fasteners of required dia and size, including necessary filling up of gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawing and the direction of Engineerincharge. (Glazing and paneling and dash fasteners to be paid for separately) : (A) For fixed portion of approved quality:- (i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 20 | B) For shutters/ sliding shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing fittings wherever required including the cost of EPDM rubber/ neoprene gasket required ( Fittings shall be paid for separately ):- (i) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). |
| 21 | Providing and fixing glazing of approved quality in aluminium doors, windows, ventilator, shutters and partition frames with EPDM rubber/ neoprene gasket etc. complete as per architectural drawing and the direction of Engineer-in-charge :-(Cost of snap beading shall be paid in basic item.) (A) With float glass panes of 4.0 mm thickness ( weight not less than 10.0 kg / sqm ) |
| 22 | Filling the gap in between aluminium frame and adjacent RCC/brick work by providing weather silicon sealant over backer rod of approved quality etc. complete as per architectural drawing and direction of the Engineer-in charge:- (i) Upto 5 mm depth and 5 mm width. |
| 23 | Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. of approved quality complete as per direction of Engineer-in-charge: Anodised aluminium of grade AC 15 ). |
| 24 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. all complete. (i) Fixed to openings /wooden frames with rawl plugs screws etc. |
| 25 | Steel work welded in built up section/framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using steel etc. complete as required:- (i)In stringers, treads, landing etc. of stair cases including use of chequered plate wherever required, all complete. |
| 26 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 27 | Providing and fixing 18 mm thick, 150 mm wide pelmet of flat pressed 3 layer or graded wood particle board medium density grade I, IS : 3087 marked including top cover of 6 mm commercial ply wood conforming to IS: 303 BWR grade, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25 × 3 mm M.S. flat 10 cm long and rawl plugs 50 mm long (designation 10 no.) etc. all complete. |
| 28 | Providing and fixing factory made door frame (single rebate) made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 60mm width & 30mm thickness and shall be fixed to wall as per instructions of Engineer-In-Charge using 100x8 sheet metal CSK screws. |
| 29 | Providing and fixing 28 mm thick door shutter made of solid PVC foam profile with homogenous fine cellular structure having smooth outer integral skin having 71mm width & 28mm thick as vertical & horizontal styles. Joints are made using solvent adhesive and GI ‘C sections (39mm x 19mm x 0.6mm thick) or M S pipe (40mm x 20mm ) stiffener frame insert & telescopic polymeric ‘L’ corners .The panel shall be filled with 3mm thick high - pressure compact laminate as per manufacturer’s specifications and directions of the Engineer-in-charge, cover moulding shall be provided for covering fixing screws and elegant look.( for W.C. bathroom door shutter). |
| 30 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 31 | Providing and fixing IS : 3564 marked Aluminium die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. complete. |
| 32 | Providing and fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : (i) 125mm |
| 33 | (ii) 75 mm |
| 34 | Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete : (i) 300x10 mm |
| 35 | ii) 100x10 mm |
| 36 | Providing and fixing ISI marked oxidised M.S.sliding door bolts with nuts and screws etc. complete (i) 300×16 mm |
| 37 | Providing and fixing fan clamp type-I of 16 mm dia M.S. bar bent to shape with hooked ends in R.C.C. slabs during laying including painting the exposed portion of loop, all as per standard design complete. |
| 38 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes |
| 39 | Supply & installation of pre-painted Galvalume sheets for roofing/cladding (size, shape and pitch of corrugation as approved by Engineer-in-charge) in 550mpa steel grade, made out of Cold Rolled Steel coated with Zinc-Aluminium alloy coating of 43.5% Zn, 55% Al and 1.5% Silicon confirming to ASTM A792/A792M and AS1397, Alloy coating AZ150/AZ70, colour coated with high quality Polyester coating, top coated of modified polyester of 20 micron, back side coat of 5 micron, having epoxy primer coat of 5 micron on both side. Sheet should have protective guard film of 25 microns minimum to avoid scratches while transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM washers filled with white lead complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(a) 0.50mm thickness |
| 40 | (D) S.H. FLOORING WORK Providing and laying 1st class quality ceramic floor tiles in different sizes (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 2017 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid over 20 mm thick cement mortar 1:4 (1 cement : 4 fine sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc. all complete as per direction of the Engineer in-charge Mat Finish Tiles/ Anti-skid Tiles/ Glossy Tiles300 mm x 300 mm in all shades and designs |
| 41 | Providing and fixing 1st class quality ceramic glazed wall tiles conforming to IS : 15622 - 2017 (thickness to be specified by the manufacturer) of approved make in all colours, shades of any size as approved by Engineer-incharge in skirting, risers of steps and dados, laid over 12 mm thick bed of cement mortar 1 : 3 (1 cement : 3 fine sand) jointed with ordinary cement slurry including pointing with white cement mixed with pigment of matching shade etc. all complete as per direction of the Engineer in-charge.450 mm X 300 mm in all shades and design |
| 42 | (E) S.H. FINISHING WORK 12 mm cement plaster of mix (i) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 43 | 15 mm cement plaster on the rough side of single or half brick wall of mix. (i) In cement mortar 1 : 6 ( 1 cement : 6 fine sand ) |
| 44 | 6 mm cement plaster of mix. (i) In cement mortar 1 : 3 ( 1 cement : 3 fine sand ) |
| 45 | Finishing walls with acrylic smooth exterior paint of required shade of approved brand and manufacture [Payment shall be made after submission of Test Certificate issued by the Manufacturer] New work ( two or more coats applied @ 1.67 litre/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 46 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 grams/ litre, of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer] :12.35.1 New work ( two or more coats) over and including water thinnable priming coat with cement primer. |
| 47 | Applying priming coat with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content [Payment shall be made after submission of Test Certificate issued by the Manufacturer]. (i) With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 48 | ii) With ready mixed red oxide zinc chromatic on steel / iron works having VOC content less than 250 grams/ litre |
| 49 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade [Payment shall be made after submission of Test Certificate issued by the Manufacturer]: (i) Two or more coats on new work |
| 50 | (F) S.H. SANITARY AND WATER PROOFING WORK Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : (i) White Vitreous china Orrisa pattern W.C. pan of size 580x440 mm with integral type foot rests. |
| 51 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : (i) W.C. pan with ISI marked white solid plastic seat and lid |
| 52 | Providing and fixing kitchen sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P. brass waste complete, including painting the fittings and brackets, cutting and making good the walls wherever required : (i) White glazed fire clay kitchen sink of size 600x450x250mm. |
| 53 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps. |
| 54 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 55 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. |
| 56 | Providing and fixing 600x120x5mm glass shelf with edges round of supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. |
| 57 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved 450mm long towel rail with total length of 495mm, 78mm wide and effective height quality and colour. (i) 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms. |
| 58 | Providing and fixing PTMT liquid soap container 109mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colours weighing not less than 105 gms |
| 59 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet:100 mm diameter |
| 60 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work including cutting chases and making good the walls etc. (i) 15 mm dia nominal bore |
| 61 | ii) 20 mm dia nominal bore |
| 62 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall (i) 15 mm dia. nominal bore |
| 63 | ii) 20 mm dia. nominal bore |
| 64 | iii) 25 mm dia. nominal bore |
| 65 | iv) 32 mm dia. nominal bore |
| 66 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer in Charge. External work (i) 25 mm dia. nominal bore |
| 67 | ii) 40 mm dia. nominal bore |
| 68 | Providing and fixing brass stop cock of approved quality : (i) 15 mm nominal bore. |
| 69 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 (i) 15 mm nominal bore. |
| 70 | Providing and fixing uplasticised PVC connection pipe with brass unions : (A)45 cm length (i) 15 mm nominal bore |
| 71 | Providing and fixing ball valve (brass) of approved quality High or low pressure, with plastic floats complete : (i) 20 mm nominal bore |
| 72 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (A) Semi rigid pipe (i) 32 mm dia |
| 73 | Providing and fixing uplasticised PVC connection pipe with brass unions : (A)45 cm length (i) 15 mm nominal bore |
| 74 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. |
| 75 | Providing and fixing 100 mm sand cast Iron grating for gully trap. |
| 76 | Providing and fixing on wall face unplasticised Rigid PVC rain water, soil, waste & vent pipes (working pressure 4 kg / cm2) conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (i) Single socketed pipe - 110 mm OD |
| 77 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water, soil, waste & vent pipes pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion: (A) Coupler (i) 110 mm |
| 78 | B) Single equal tee without door (i) 110x110x110 mm |
| 79 | (C) Single equal tee with door (i) 110x110x110 mm |
| 80 | (D) Bend 87.5° (i) 110 mm |
| 81 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water, soil, waste & vent pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing with cement mortar 1 : 4 (1cement : 4 fine sand) making good the wall etc. complete. (i) 110mm |
| 82 | Providing and fixing to the inlet mouth of rain water, soil, waste & vent pipes pipe PTMT grating with thickness of 8mm and weighing not less than 100gm. (i) 100 mm |
| 83 | Grading roof for water proofing treatment complete as required as per direction of the Engineer-in-charge with : Cement mortar 1:4 (1cement : 4 fine sand) |
| 84 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification per 50kg of Cement. Please Enable Macros to View BoQ information |