| 1 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure withcover plate having locking arrangement and watering pipe etc.(but without charcoal/ coke and salt ) as required. |
| 2 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/cable as required. |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPEpower cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 Sq mm |
| 4 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required Upto 35 Sq mm |
| 5 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting,jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 6 | Excavation of the trenches in hard rock soil not exceing 1.5 mtr width and lift upto 1.5 mtr including getting out the excavated soil and disposal of excavated soil as directed within a lead of 50 mtr |
| 7 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 9 | Supply of XLPE insulated PVC sheathed AL. conductor armoured Cable 1.1 KV grade conforming to IS-7098 of following size- (a) 2X6 Sq mm |
| 10 | (b) 2X10 sqmm |
| 11 | Fabrication , supplying and fixing class B galvanised single overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 12 | Fabrication , supplying and fixing class B galvanised double overhang arm bracket made out of 250 mm long galvanised top tube with cap and 250 mm long 32 mm dia galvanised pipe with tightening bolts complete as required |
| 13 | Supply of PVC insulated and FR PVC sheathed multicore copper conductor 1.1. kv grade conforming to IS694 as reqd:-3x1.5 sqmm |
| 14 | Supplying, Installation, Testing & Commissioning of 40 watt Street light LED fixture, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI>70, under voltage and over voltage protection,EMI-EMC as per CISPR-15, lenses for beam angleas per IESNA type I/II/III as per the width of the roadand the project requirement., suitable to fit in up to65mm dia pipe, life time (LED,Driver & electricalcircuitary) of minimum 50000 Burning Hourswith 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11report, CCT 3000°K / 4000°K / 5700°K /6500°K (Asper ANSI Bin), SDCM(Standard Deviation ColorMatching) <5, Maximum power consumption shouldnot more than the specified rating and Fixture shallbe of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). |
| 15 | Fabrication, supply & erection of 4.0 mtr height ,3mm thick bottom dia of 130, & top dia of 70 mm base plate of size 225X225X12mm thick size flange mounted hot dip galvanized octagonal pole made from HT steel plate window with flash cover with full vertical window cover at appropriate height form the base plate on existing cement concrete predestal as required i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4mm thick of suitable length and having suitable size tapped holes as reqd. terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel of suitable length ,6 Amp SPMCB 'C' characherstics earth stud cable support clamp suitable for upto 4X25 sq mm cable Logo/Name of manfucturer shall be embossed on the pole Galvanization as per relevant as. 4.0 mtr height ,3mm thick bottom dia of 130, & top dia of 70 mm base plate of size 225X225X12mm thick |
| 16 | Providing and laying in position M25 grade reinforced cement concrete foundation of size 450mm(L)X450mm wide and 1000 mm deepi/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bars of 12 mm dia- 960mm long (approx) 8 nos. and reinforcement of cold twisted bars of 12 mm dia - 960 mm long (approx) -8 nos and reinforcement of cold twisted bars of 8 mm dia -1400 mm ( approx) -6 nos.(with 150 mm spacing ) as required with supplying and position of 4 nos. foundation DCW HDPE for cable entry and exit as required for 3 m to 5m pole. |
| 17 | Supplyinhg and erection of galvanised 'D' iron clamp complete with shackle insulator (75mmx 90mm ) GI bolts nuts and washer coach screw etc |
| 18 | P&F of water/weather proof junction /pole box made out of hot press moulded sheet moulding (SNC) compound fire retaradant (temp. resistance upto 200 C) of size 200 X 160 X 98 mm (NS) complete with Suitable arrangement for fixing of 2 nos of 6 to 32 amp one No SP-MCB(6to32Amp) & 63 amp Double pole Isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN channel with 2 nos of MS clamp with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. |
| 19 | Providing and fixing of Stainless steel name plate of size 6×8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required |
| 20 | P/F Name board made of MS Sheet 90X60 Cm, 1 mm thick with frame of MS angle 50X50X6 mm , two diagonal braces at the back of sheet of Ms Flat 40X6 mm total height of the bpard above ground level 2.40 M Length of Leg Below ground 0.30 M embeded in CC Block 1:2:4( 1 cement , 2 Coarse Sand , 4 Graded stone aggregate 40 mm nominal size)30X30X45 cm including excavation and removal of surplus earth with in 50 m lead applying priming coat of approved steel primer painting with synthetic enamel paint of approved quality and lattering with enamel paint of approved colour ( one side as per drawing/ direction of engineer in charge Please Enable Macros to View BoQ information |