| 1 | Supply & Laying in trenches or fixing on wall or passing through pipe or in cable ducts, 1100 volts grade 3.5/4 core XLPE , armoured, electric power cables (heavy duty) with aluminium conductor including termination lugs of the following size complete all as specified and directed by Engr-in-Charge including dismantling old one. |
| 2 | 16 Sqmm 4 core |
| 3 | 25 Sqmm 4 core |
| 4 | 50 Sqmm 3.5 core |
| 5 | 70 Sqmm 3.5 core |
| 6 | Excavation in trenches n.exc 1.5mtr wide and not exc 1.5mtr depth and getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. |
| 7 | Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr but n.exc 3.0 mtr in depth and getting out in any type of soil for taking up or laying of cable, foundation of poles, stay etc complete all as specified and directed by Engr-in-Charge. |
| 8 | Returning and filling in of excavated soil including spreading,levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed by Engr-in-Charge. |
| 9 | Removal of surplus soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge. |
| 10 | Material & Labour for Sand cushioning/sand covering for underground cable protection complete all as specified and directed by Engr-in-Charge. Note: Punned thickness only will be measured and paid. |
| 11 | Supply and laying sub class 'B' bricks of old size (standard size as per local availability) laid along alignment of cable as protection to cable in trenches complete all as specified and directed by Engr-in-Charge. |
| 12 | Material & Labour for GI pipe light grade 50 mm dia for cable protection on road crossings /plinth protection/ lamps post etc with fixed to the pole wall etc. suitable fittings for cable protection complete all as specified and directed by Engr-in-Charge. |
| 13 | Material & Labour for Boring of holes under road, pavement, hard standing by trenchless technology by manually and necessary machine including HDPE pipe of 50 to 150 mm dia suitable for 0.4 mpa working pressure/GI Pipe complete all as specified and directed by Engr-in-Charge. |
| 14 | Supply & fixing of LT panel board shall be suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of incomer ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size \\"F\\" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge:- Incoming :- (i) MCCB 4 pole 250 Amp, 35 KA,Micro processor released Adjustable type - 01 No. (ii) 4 Pole Aluminium Bus Bar 400 Amp(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz(iv) CT of ratio 400/5 A,p- 01 Set of 3(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3Outgoing :- (i) MCCB 4 Pole 125 Amp, 16 kA - 01 No (iv) MCCB 4 Pole 63 Amp, 16 kA, - 04 No |
| 15 | Supply & fixing of LT panel board shall be suitable for operation on AC 415 Volt, 3 Phase, 50 Hz, 4 wire system and shall have aluminium bus bar of 1.5 times of incomer ACB/MCCB capacity with colour insulating tape / sleeves mounted on suitable size \\"F\\" class, non hygroscopic, non combustible insulators, provision for fixing MCCBs / MCBs, necessary inter-connections with bus bar / strip with colour code insulation, including LED indicating lamps (R, Y, B), digital voltmeter with CT / PT & ammeter of suitable capacity with selector switches, provision of cable entry / exit provided in bottom, connections of all outgoing / incoming, existing / new copper wires of required size (minimum 2.5 sqmm) with following accessories and including taking down existing LT Panel and acessories inside complete all as specified and directed by Engr-in-Charge:- Incoming :- (i) MCCB 4 pole 160 Amp, 35 KA,Micro processor released Adjustable type - 01 No. (ii) 4 Pole Aluminium Bus Bar 250 Amp(iii) Digital type 3 Ph multifunctioning meter to measure Amp, Volt, Hz(iv) CT of ratio 400/5 A,p- 01 Set of 3(v) LED Phase Indication lamp (R, Y, B)-01 Set of 3Outgoing :- (i) MCCB 4 Pole 63 Amp, 16 kA - 02 No (iv) MCCB 4 Pole 40 Amp, 16 kA, - 03 No |
| 16 | Material & Labour steel tubular swaged pole 09 metre long complete with cast iron base plate finial taper plug ,bolts, nuts and secrew all as specified type 410, SP-31 (9.0 metres long) includuing painting up to 1.5 M above PCC coping in black and white strips 5 Nos each 30 CM high staring from bottom of pole and two coats of epoxy based paint alumimium grade finish to remaining external surface over one coat of suitable primer complete all as specified and directed by Engr-in-Charge. |
| 17 | Material & Labour for cement concrete 1:4:8 type D2 ( using 40mm graded stone aggregate) for base of foundation of pole / stay including form work etc complete all as specified and directed by Engr-in-Charge. |
| 18 | Material & Labour for cement concrete 1:3:6 type C2 ( using 40mm graded stone aggregate) for foundation of pole / stay including form work etc complete all as specified and directed by Engr-in-Charge. |
| 19 | Material & Labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole, including necessary form work complete all as specified and directed by Engr-in-Charge. |
| 20 | Supply & Fixing in repair PVC insulated 3 core 1.5 Sq mm stranded copper conductor cable for connecting junction box to street light fitting testing and commissioning complete all as specified and directed by Engr-in-Charge. |
| 21 | Supply and fixing timelite distribution boards (street light DBs) 65 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one complete all as specified and directed by Engr-in-Charge . |
| 22 | Supply & Fixing loop-in/loop-out box of internal size 250 x 200 x 105 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as specified and directed by Engr-in-Charge. |
| 23 | Material & Labour for bracket for street light fitting made out of 40 mm bore pipe light grade GI tube bent to shape required, not less than 1.20 meter long, fixed with and including MS flat iron clamps made out of 40x6 mm FI, bolts, nuts, washers etc complete including dismantling old defective complete all as specified and directed by Engr-in-Charge. |
| 24 | Supply & Fixing 40mm Gavlvanised steel tube light grade for passing of cable through foundation upto junction box of street light complete all as specified and directed by Engr-in-Charge |
| 25 | Taking down old unserviceable street light fittings from any height and Supply & fixing 60 Watt LED street light fittings comprising of epoxy powder coated housing, enclosed with cover in frame, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion complete all as specified and directed by Engr-in-Charge. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items. |
| 26 | Material & Labour Earthing for poles and other machinery/eqpt using GI strip as earth lead and MS galvanized steel earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate is not less than 1.5 mtr below normal ground level connected to galvanized iron wire of 4mm with GI pipe, nuts, bolts and washers complete upto and including test point made out of 40x3mm GI flat, PCC pit of required size in PCC 1:2:4 type B1 and RCC cover with frame, charcoal, common salt15cm at round the earth plate watering pipe 20mm med grade/galvanized and 40mm dia GI pipe light grade for GI strip protected steel with funnel complete all as specified and directed by Engr-in-Charge . |
| 27 | Note : Contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge. Please Enable Macros to View BoQ information |