| 1 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exeeding 1.5 m deep, getting out the excavated earth bottom surface to required gradient complete all as specified and directed. |
| 2 | Material and Labour for Removal of excavated material such as soils n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point. |
| 3 | Returning filling in, and including spreading and leveling in layers not exceeding 25 cm thick complete all as specified & directed. |
| 4 | Supply and spreading riddled earth for cushioning of the UG cable in trenches all as specified and as directed |
| 5 | Material and labour for well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed. |
| 6 | Laying only serviceable old bricks retrieved from item No 1 above. |
| 7 | Taking out following defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account. |
| 8 | Laying only XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 10 Sqmm, 4 core in trenches or fixed to wall /passing through pipe / pole and testing complete all as specified and directed. Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately, (ii) Old serviceable cable obtained by taking out shall be re-used. |
| 9 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 16 sq mm, 4 core. |
| 10 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 25 sq mm, 4 core. |
| 11 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core. |
| 12 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 50 sq mm, 3.5 core. |
| 13 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 240 sq mm, 3.5 core. |
| 14 | All as per Srl item No. 8.00 here-in-before but Cross sectional area 300 sq mm, 3.5 core |
| 15 | Supply, testing and commissioning of XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 10 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed. Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately. |
| 16 | All as per Srl item No. 15.00 here-in-before but Cross sectional area 16 sq mm, 4 core |
| 17 | All as per Srl item No. 15.00 here-in-before but Cross sectional area 25 sq mm, 4 core. |
| 18 | All as per Srl item No.15.00 here-in-before but Cross sectional area 35 sq mm, 3.5 core |
| 19 | All as per Srl item No.15 .00 here-in-before but Cross sectional area 50 sq mm, 3.5 core . |
| 20 | All as per Srl item No.15.00 here-in-before but Cross sectional area 70 sq mm, 3.5 core |
| 21 | All as per Srl item No.15.00 here-in-before but Cross sectional area 95 sq mm, 3.5 core |
| 22 | All as Srl item No.15.00 here-in-before but Cross sectional area 120 sq mm, 3.5 core |
| 23 | All as per Srl item No.15.00 here-in-before but Cross sectional area 150 sq mm, 3.5 core |
| 24 | All as per Srl item No.15.00 here-in-before but Cross sectional area 185 sq mm, 3.5 core |
| 25 | All as per Srl item No 15.00 here-in-before but Cross sectional area 240 sq mm, 3.5 core |
| 26 | All as per Srl item No.15.00 here-in-before but Cross sectional area 300 sq mm, 3.5 core |
| 27 | All as per Srl item No.15.00 here-in-before but Cross sectional area 400 sq mm, 3.5 core |
| 28 | Supply and fix in replacement route indicator for marking of LT UG cable of any size with cast iron round plate of 100 mm dia suitably fitted with and including MS angle iron 40x40x5mm with GI nut, bolt and washers, MS angle grouted in PCC block of 20x20x30cm including necessary earthwork and painting the iron surface with two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified and as directed. |
| 29 | Material and labour for bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of size 450 x 300 x 200 mm including aluminum busbar fixed vertically in chamber of capacity 200 Amps for phase and 100 amps for neutral for incoming and out going. The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system and all as specified and directed. NOTE :-- Earth work, PCC work and MS works shall be measured and paid separately. Please Enable Macros to View BoQ information |
| 30 | Material and labour for bus bar chamber cubical inclined top out door type made out of 3 mm thick MS sheet of size 450 x 300 x 200 mm including aluminum busbar fixed vertically in chamber of capacity 200 Amps for phase and 100 amps for neutral for incoming and out going. The panel shall be suitable for 415 volts, 50 Hz, 3 phase 4 wire system and all as specified and directed. NOTE :-- Earth work, PCC work and MS works shall be measured and paid separately. Please Enable Macros to View BoQ information |