| 1 | M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete including demolition of existing complete all as specified and directed. |
| 2 | M&L for hardcore of gauge of broken stone/boulder n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified & directed |
| 3 | M&L for preparation of old plastered surfaces and applying one coat of synthetic enamel paint on kerb stone of any description over 10cm girth or width, not otherwise described complete all as specified and directed. |
| 4 | M&L for brick work with sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 5 | M&L for plain cement concrete (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in sub base for paver block paving to raise level including necessary form work complete including demolition of existing all as specified and directed. |
| 6 | M&L for rubber moulded chequered cement concrete coloured tiles with glossy finish 30cm x 30cm x 25mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry with pigments in floors, incl cement mortar 1:4 screed bed incl dismantling of existing tiles complete all as specified and as directed by Engr-in-Charge. |
| 7 | M&L for 60mm thick PCC (M-35) factory made with grey cement and pigment interlocking tiles/ paver block of shape/ size as conforming to IS 15658, joints will be filled with fine sand including demolition of existing tiles and screed complete all as specified and as directed by Engr-in-Charge. (Note Sand will be paid under relavent item). |
| 8 | All as per Srl item No 07 above but except interlocking tiles (old dismantled serviceable interlocking tiles obtained from Srl item No 07 shall be reused after necessary cleaning.) |
| 9 | M&L for 80mm thick PCC (M-35) factory made with grey cement and pigment interlocking tiles/ paver block of shape/ size as conforming to IS 15658, joints will be filled with fine sand including demolition of existing tiles and screed complete all as specified and as directed by Engr-in-Charge. (Note Sand will be paid under relavent item). |
| 10 | M&L for sand filling under floors or in paving or in foundations including watering and consolidation complete all as specified. |
| 11 | M&L for PCC 1:2:4 type B1 (using 20mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed by Engineer-in-Charge. |
| 12 | M&L for vitrifed designer heavy duty tile of size 400mm x 400mm on footpath etc, 12mm thick coloured outdoor set, jointed and pointed in neat cement slurry with white cement and pigment as in path/ floor, pattern of tiles as approved by GE over and including 15mm screed bed in CM 1:6 including demolition of existing tiles and screed complete all as specified and directed. |
| 13 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth for foundation etc or for shafts, wells, cesspits manholes, pier holes etc n exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed. |
| 14 | Removing excavated materials not exc. 50 m and depositing where directed at a level not exc. 1.5 m above the starting point complete all as specified and as directed. |
| 15 | Demolition of brick work or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc. |
| 16 | M&L for brick work with sub class 'B' old size bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed. |
| 17 | All as per Srl item No 16 above but except bricks (old dismantled serviceable bricks obtained from Srl item No 15 shall be reused after necessary cleaning of mortar) |
| 18 | M&L for flush pointing as bricks laid flat in CM 1:3 with raking out new and existing joints, complete all as specified and directed. |
| 19 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends complete all as specified & directed. |
| 20 | M&L for cement concrete 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in surface channel and drain and similar complete all as specified and directed. |
| 21 | Demolition of PCC of any description and in any position not otherwise specifically provided for complete all as specified & directed. |
| 22 | M&L for PCC 1:2:4, type B1 (using 20 mm graded crushed stone aggregates) as in coping/band and bed block etc incl necessary formwork,weathering,slightly rounded or chamfered angles and throating complete all as specified and directed. |
| 23 | M&L for providing precast cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in louvres and jallies, 25mm thick (measured solid),including all mouldings and set in mortar CM 1:4 all as specified and directed |
| 24 | M&L for preapring plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed. |
| 25 | Demolition of cement concrete (reinforcment) of any description all as specified and directed by Engr-in charge. |
| 26 | Form work to rough finished surface of concrete flat to soffits of shelve, chajja, fins etc including supports over hangs etc complete all as specified & directed. |
| 27 | S&F 6mm dia and over TMT bar cut to length bent to shaps including cranking binding spirraly, hooping, hooking end and binding with MS wire (anealed) not less then 0.9 mm dia or securingwith clips as specified. |
| 28 | M&L for RCC 1:2:4 type B-1(using 12.5mm graded crushed stone aggregate) as in chajjas facia, shelves etc and similar work all as specified. |
| 29 | M&L reinforced concrete drain pipes NP3, 300mm bore include for laying pipes level or to falls In trenches, on concrete bed and all necessary extra joints, waste and cutting as jointed with collars including demolition of existing pipes complete all as specified and directed. |
| 30 | S&F pre-painted galvanlume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to walls,fixed with self tapping screws including dismantling of old asbestos/ corrugated/ semicorrugated sheet all as specified and directed. |
| 31 | Dismantling framed work timber scantlings 40sqcm and over in section, in any position complete all as specified and directed. |
| 32 | S&F of rolled mild steel Gde Fe-410-W Gde E-250 Quality-A in Roof trusses (framed), trussed, purlins crane gantries, joist, channel, steel tube, rails & fastenings & heavy brackets framimg (beam, tee, angle, coulmn, gusset plates, channel, hollow square/rectangular or flat section) including distance pieces, cleats with riveted, bolted or welded attachment etc complete all as specified and directed by Engr-In-Charge. |
| 33 | M&L for pre cast saucer drain RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) and similar work etc complete all as specified and directed. |
| 34 | M&L for 15 mm thick rendering of ready mix mortar of approved make on brick work/stone/concrete wall, facia, projection, chajja etc. external surfaces finished even and smooth without using extra cement of any shape, any size incl taking down existing plaster of any size incl raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed. |
| 35 | M&L for plastered surfaces of wall and applying two coats of cement based paint complete all as specified and as directed. |
| 36 | M&L for 80 mm thick factory made precast perforated reinforced cement concrete cover slab(1:2:4) type B-1 (using 20mm graded crushed stone aggregate) not exc 0.5 sqm eachwith 2 mm thick MS frame flat iron with required width and necessary reinforcement over drains, manhole sizes of drain cover ordered as required at site all as specified and directed by Engineer -in- Charge. |
| 37 | S&F for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe-290,Gde-E-165 all as specified and directed. |
| 38 | A Schedule of Credit for old/unserviceable demolished/ dismantled items has been catered for in the tender. The Schedule of Credit is pre-priced by MES. The final amount of the tender shall be arrived at after deducting the total amount of Rs. 53,205/- Schedule of Credit from the total amount of BoQ as per General Summary sheet catered for after Schedule of Credit. Please Enable Macros to View BoQ information |