| 1 | M&L for attending daily complaints in repairs and maintenance of geysers, Solar water heater of any capacity/ any make, lodged by the users complete to make serviceable condition with skilled electrician for (Geyser & Solar Water Heater) including disconnecting electric and water connection of the geyser, taking down from its position on ground, dismantling geyser complete such as removing tank from its outer body , removing apparatus plate from the tank, descaling the geyser inner tank and apparatus plate complete, testing thermostate, element , and tank from leakage, reassembling the geyser, replacement of unserviceable parts such as heating element, thermostat, indication lamp, plug top , three core wire, rubber gasket, inner tank, split plate, outer bottom cover, apparatus plate if required (Spares parts will be measured and paid under relevant item of the Sch. \\"A\\" as a supply only) testing the geyser and installation of the geyser into its existing position and connecting all electric and water supply connection complete all as directed. |
| 2 | Taking down of defective geyser of any capacity from site transportation to E/M store yard for repair, strip opening for complete overhauling and ascertaining the repair/replacement (spare part shall be measured and paid seperately under respective items of Sch. \\"A\\" as supply only) & re-assembling the geyser after repair/replacement and including connect with existing electric & water connection, testing,refixing at site, complete all as specified and directed. |
| 3 | Disconnecting of electric and water supply connection of geyser for supply and replacement of brass chromium in-door assembly(shyphon assy) 6/9 hole for 50 Ltrs Geyser including connect with existing connections and testing, complete all as specified and directed. |
| 4 | Disconnecting of electric and water supply connection of geyser for supply and replacement of brass chromium in-door assembly(shyphon assy) 6/9 hole for 25 Ltrs Geyser including connect with existing connections and testing, complete all as specified and directed. |
| 5 | S&F in replacement of 15 mm bore, GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid in floors including cutting chases, pinning in and making good distrubed surface to match with existing surface and finish, etc., complete all as specified and as directed. |
| 6 | S&F in replacement of bib cock with flange 15mm dia, chromium plated, cast copper alloy, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and directed. |
| 7 | S&F in replacement of angular stop cock with wall flange, chromium plated, cast copper alloy, fancy type 15mm dia complete all as specified and as directed. |
| 8 | S&F in replacement of PVC connection heavy duty, nylon braided, suitable for hot water, with brass alloy chromium plated nuts and nylon washers, of size15mm bore and 450 mms long, complete all as specified and as directed. |
| 9 | All as per srl item No 8.00 here in-above but 600mm long. |
| 10 | S&F in replacement of single pole and neutral enclosure with two pin earth industrial plug and socket with one MCB SP 20 Amps, 'C' curve, complete all as specified and as directed. |
| 11 | Supply only for heating element (ISI-Marked) of suitable type as per existing including rubber ring clamping screws etc,complete of 1.5KW, complete all as specified and as directed. |
| 12 | All as per srl item No 11.00 here-in-above but 2.00 KW |
| 13 | Supply only for thermostate ISI-marked for geyser as per existing of range 15-65 degree temperature, complete all as specified and as directed. |
| 14 | Supply only for auto-cut ISI marked for geyser as per existing, complete all as specified and directed. |
| 15 | Supply only for steel vessel (tank)of geyser capacity 25 ltrs. as per existing type of all as specified directed by EIC. |
| 16 | All as per srl item No 15.00 here-in-above but capacity 50 ltrs. |
| 17 | Supply only for vacuum safety valve of suitable size on inlet side of geyser, complete all as specified and directed. |
| 18 | Supply only for brass chromium plated horizontal/vertical non return valve of size 15mm bore (ISI Marked) on inlet side of Geyser, complete all as specified and directed. |
| 19 | Supply only for brass nut fusible plug suitable for Geysers, complete all as specified and directed. |
| 20 | M&L for drilling hole in wall, grouting fastner nut and bolt not less than 100 mm long for holding geyser upto 50 ltrs in wall including making good and matching existing surface and finish all as directed. |
| 21 | Supply only for indicating lamp of red and green colour, for Geysers including connecting, complete all as specified and directed. |
| 22 | Supply only for bottom split inspection cover for geyser capacity 25 ltrs. of any make,complete all as specified and directed. |
| 23 | All as per item No. 22.00 here-in-above but capacity 50 Ltrs |
| 24 | Supply only for outer body made of stainless steel sheet for geyser capacity 25 ltrs. of any make, complete all as specified and directed. |
| 25 | All as per item No. 24.00 here-in-above but capacity 50 Ltrs. |
| 26 | Supply only for Rubber Gasket as per site requirement for 25/50 ltrs. geyser, complete all as specified and directed. |
| 27 | M&L for scrapping old paint and applying spray painting two coats of synthetic enamelled paint of approved quality including writing MES No. / building no. in letters of size 40 mm width. For geyser cap. - 25 ltrs of any make/type . (NOTE : Rates shall deemed to be included for taking down Geyser in location and position , disconnecting and refixing same existing postion &reconnecting electrical / water connection all as directed) |
| 28 | All as per item No. 27.00 here-in-above but capacity 50 Ltrs |
| 29 | M&L in replacement of GLASS WOOL for Geysers of any capacity, complete all as specified and directed. |
| 30 | S&F in replacement of MCB SP 5 To 32 AMP Amp, 10KA 'C' series, complete all as specified and directed. |
| 31 | S&F in replacement of three pin top 20 Amp, complete all as specified and directed. |
| 32 | S&F in replacement of metal clad plug socket 3 pin 20 Amp, complete all as specified and directed. |
| 33 | S&F in replacement of metal clad plug Top 3 pin 20 Amp, complete all as specified and directed. |
| 34 | Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switchs, sockets, aluminium conductor cable with and incl wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed. |
| 35 | M&L for concealed point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit/Surface conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including piano sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of piano switch, complete all as specified and directed. |
| 36 | S&F in replacement of flush type Socket, 16 Amps, - 2/3 pin combined flush type, 230 Volts complete all as specified and as directed. |
| 37 | S&F in replacement of flush type piano Switch 1 way, 16 Amps, flush type, 230 Volts complete all as specified and as directed. |
| 38 | S&F in replacement of PVC insulated copper conductor 1100 volts grade circular cable of size 2.5 sqmm (50/.025) 3 core complete all as specified and as directed. |
| 39 | S&F for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 2.5 Sqmm and one run of 2.5 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 20 mm dia with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc including taking down existing sub main wiring., complete all as specified and as directed. NOTE: Two runs of 2.5 Sqmm cable with one run of 2.5 Sqmm earth wire and PVC conduit shall be measured & paid for as one length. |
| 40 | All as per item No. 39.00 here-in-above, but cable drawn through in PVC casing-N-capping |
| 41 | S&F in replacement of socket outlet 2 in 1, 3 pin, 6 and 16 amp modular type ISI Marked, complete all as specified and directed. |
| 42 | S&F in replacement of switch modular type single pole one way 15/16 Amp ISI Marked, complete all as specified and directed. |
| 43 | M&L for welding/brazing steel/copper vessel ( storage water tank of capacity 25/50 ltrs ) including pressure testing and leakage testing, complete all as specified and directed. |
| 44 | Cheking of Solar water heater system of any capacity and make installed at ARMY AREA Jodhpur, complete all as specified and directed. |
| 45 | De-scaling & servicing of Solar Water Heater system of any capacity and any makeincluding re-insulation and making fit for smoth function,complete all as specified. |
| 46 | M&L for solar heat absorbers (collectors) with selective coating sheet as per existing panel length & width complete all as specified. |
| 47 | S&F in repair for heating element of capacity 3/5 KW ISI Mark as per existing panel length & width complete all as specified. |
| 48 | M&L for thermo stat ISI Marked, suitable for existing panel complete all as specified. |
| 49 | M&L for repair to damaged panel tubing with gas welding of Solar Water Heater of any capacity/any make, complete all as specified and as directed. |
| 50 | Dismantling and taking down unserviceable pressure pumps and motor of cap not more than 2 HP of any capacity and description and refixing to the position after servicing and minor repairs as refilling of pressure replacement of auto cut switch etc the job include rewinding of motor all as specified and directed. |
| 51 | S&F in replacement of stop Cock CP brass 15 mm bore screwed down with crutch or butterfly handle, complete all as specified and directed. |
| 52 | M&L for replacement of bottom cover for outer body made out of MS sheet of same guage of existing cover and size duly painted with two coats of synthetic enamel paint of existing geyser colour over one coat of red-oxide primer, complete all as specified and directed. |
| 53 | M&L for repair, rewinding of submersible pump monoblock type of capacity upto 3 HP, single or three phase, any make incl connection, testing complete all as specified and directed |
| 54 | S&F in replacement spare parts of submersible pump monoblock type of capacity upto 7.5 HP (i.e. water pump lock, thread cap, motor fan, pump tube pipe, wire assembely, plastic pump handle and capacitor cover) incl connection, testing complete all as specified and directed |
| 55 | S&F in replacement direct-on-line starter submersible pump of capacity 5 HP, 3 Phase, 415 Volt, with and including connection, testing,complete all as specified and directed. |
| 56 | NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of \\"Credit\\" from the Total quoted amount Please Enable Macros to View BoQ information |