| 1 | Demolition of PCC Block masonary built in cement mortar complete all as specified incl coping. |
| 2 | M & L for pre cast PCC block mosonary Type C-1 1:3:6 exc 10 cm width and set in CM 1:6 all as specified |
| 3 | Demolition of cement concrete (un re-inforced) in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified . |
| 4 | M&L Plain cement concrete type D-2, 1:4:8(using 40mm graded stone aggregate) Nominal Mix as in foundation , filling and mass concrete incl formwork complete all as specified and directed. |
| 5 | M&L 15mm thick cement plastering on concrete surfaces in CM (1:4) finishing surfaces even and fair without using extra cement complete all as specified and as directed. |
| 6 | M&L for prepration of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of chalk whiting primer on walls etc complete all as specified and directed. |
| 7 | Dismantling posts or struts (wood, steel or R.C.C.) any section embeddedin concrete, including taking out embedded portion and making good disturbed ground etc. Complete all as specified and as directed. |
| 8 | Dismantling fencing wire mesh, any type |
| 9 | S&F For Mild Steel angle as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 etc. complete all as specified and as directed. |
| 10 | Supply only Chain link MS galvanisd fencing, any size or type etc. Complete all as specified and as directed by Engr - in - charge |
| 11 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire etc. Complete all as specified and as directed. |
| 12 | S & F For 5 to 10 mm dia. of neck ,mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long etc. Complete |
| 13 | S&F For round mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, for chain link fencing, complete all as specified and as directed. |
| 14 | S & F For in repair galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) etc. complete all as specified and as directed. |
| 15 | Preparation of new or previously untreated surfaces of iron of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over and including a of red oxide primer complete all as specified and directed |
| 16 | Preparation of old surfaces of iron of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed |
| 17 | Dismantling structural steel work including doors, gates but excluding framed truss etc. Complete. |
| 18 | S & F For Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing etc. complete all as specified and as directed. |
| 19 | Dismantling stone slab and tiles of any description and thickness as in floor including cement mortar bedding and rubbish off the premisses complete all as specified and directed. |
| 20 | M&L for 75mm thick PCC type D-2 (1:4:8) using 20mm graded aggregate as in sub base etc complete all as specified and directed |
| 21 | M&L for girt cushioning below interlocking paver block incl spreading and levelling complete all as specified and directed. |
| 22 | M&L for 60mm thick machine pressed precast concrete interlocking paver block reflective type coloured any shape and size confirming to IS 15658-2006 of M-35 grade , with grey cement and pigment complete all as specified and directed. |
| 23 | M&L for Chequered cement concrete tiles with grey cement and pigments 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over and including 15 mm thick screed bed or bedding layer in cm 1:6 etc. complete all as specified and directed. |
| 24 | M&L PCC 1:2:4 type B-1(Using 20mm graded crushed stone agg) in copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed |
| 25 | M & L for 25mm thick Rough dressed lime stone slab flooring, laid dry, jointed and pointed in cement mortar 1:3 incl 15mm bedding layer 1:6 complete all as specified and directed. |
| 26 | M & L for Welding in repairs exc 2.5cm but n exc 5cm to steel gates post and similar article thickness of Metal to be welded exc 9mm but not exc 20 mm as specified by Engr -In Charge.The rates include for cleaning and preparing the surfaces to be welded together, holding the members in true position while welding and bevelling of edges, as required, Please Enable Macros to View BoQ information |