|
| 1 | S&F in replacement of XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade cross sectional area 16 sq mm 2 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed by Engineer-in-Charge.Note: Earthwork, RFR, removing of excavated soil, cable cover, sand for cusioning of cable shall be measured and paid seperately under relative item. |
| 2 | All as per item No. 1.00 here-in-above, but cross sectional area 16 sq mm 4 core. |
| 3 | All as per item No. 1.00 here-in-above, but cross sectional area 25 sq mm 3.5 core. |
| 4 | All as per item No. 1.00 here-in-above, but cross sectional area 35 sq mm 3.5 core. |
| 5 | All as per item No. 1.00 here-in-above, but cross sectional area 50 sq mm 3.5 core. |
| 6 | All as per item No. 1.00 here-in-above, but cross sectional area 70 sq mm 3.5 core. |
| 7 | All as per item No. 1.00 here-in-above, but cross sectional area 95 sq mm 3.5 core. |
| 8 | All as per item No. 1.00 here-in-above, but cross sectional area 120 sq mm 3.5 core. |
| 9 | All as per item No. 1.00 here-in-above, but cross sectional area 150 sq mm 3.5 core. |
| 10 | All as per item No. 1.00 here-in-above, but cross sectional area 185 sq mm 3.5 core. |
| 11 | Supplying and laying for GI tubing light grade in repairs incl. accessories for protection of cables on poles / under road crossing of sizes 80 mm bore including taking down of existing pipe, complete all as specified and directed. |
| 12 | All as per item No. 11.00 here-in-above, but sizes 50 mm bore |
| 13 | All as per item No. 11.00 here-in-above, but sizes 40 mm bore |
| 14 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and not exceeding 1.5 m in depth and getting out in all type soil, complete all as specified and directed. |
| 15 | Excavation in trenches not exceeding 1.5 m wide and exceeding 1.5 m in depth upto 3.0 m for erection of poles, struts/stays, leveling of yard etc not exceeding 10 M² on plan and getting out in all type soil, complete all as specified and directed. |
| 16 | M&L for dry clean tibba sand as in sand cushioning to underground cable including punning down of sand layer, complete all as specified and as directed. Note :- Punned thickness shall only be measured and paid. |
| 17 | Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1, flat size 250 mm x 150 mm x 40 mm and abutting each other with gap between adjacent precast concrete cable cover not exceeding 10 mm over underground cables for protection, complete all as specified and as directed. |
| 18 | Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soils complete all as specified and directed. |
| 19 | Removal of excavated material soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed. |
| 20 | M&L for Auguring/ Driling /Boring of holes under road, pavement, hard standing by trenchless technology by mannual /machine, including fixing of GI pipe of 100 mm bore dia, complete all as specified and directed. |
| 21 | Re-routing/relaying of existing LT cable PVC/XLPE insulated aluminium conductor armoured with glavanised steel wire complete of any size and core from any position i.e ground /wall/poles/ culverts etc complete with protection cover, sand, pipe complete all as specified and directed by Engineer-in-charge. Note:- (i) Old cable as obtained shall be re-used. (ii) Old serviceable protection cover, protection pipe and sand obtained under this item shall be reused if found serviceable.(iii) Earth work and any other new items shall be measured and paid separately under relavent items. |
| 22 | Material and labour for replacement of old unserviceable voltmeter/ Ammeter with Panel mounted multi function three phase digital energy meter of accuracy Cl-1.0 for measuring Voltage, Current, KW, KVAR, KWH, KVAH and power factor and making the disturbed surface good by welding/riveting in MS sheet 1.6 mm thick on the hollow portion duly painted and cailbrating the meter according to the CT all as specified and as directed at site. |
| 23 | Material and labour for replacement of old unserviceable CT of LT Panel /Feeder pillar box with CT of ratio upto 200/5 Amps or as required at site according the load incl connecting, disconnecting and testing complete all as directed at site. |
| 24 | Material and labour for replacement of old unserviceable indicator lamp any type with LED based indicating lamps of RYB colour incl disconnecting and connecting of the same all as directed at site. |
| 25 | Material and labour for fabrication of copper busbar iE26:E29 hot in any size and shape all as directed and including RYB insulation mounted on epoxy cast/polymer glass insulators all as directed by Engr-in-charge. |
| 26 | Supply, fixing and replacement of MCCB 630 Amps 4 pole 50 KA 415 Volts 3 Phase 4 wire, microprocesssor release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as directed |
| 27 | Supply, fixing and replacement of MCCB 400 Amps 4 pole 36 KA 415 Volts 3 Phase 4 wire, microprocesssor release type MTX1.0 (Icu=Ics=100%), Uimp=8kV including accessories like spreaders, nut bolts, lugs etc suitable setting complete all as directed by Engineer-in-Charge. |
| 28 | All as per item No. 27.00 here-in-above, but MCCB 250 Amps 4 pole 36 KA, thermal magnetic adujstable release type. |
| 29 | All as per item No. 27.00 here-in-above, but MCCB 160 Amps 4 pole 36 KA, thermal magnetic adujstable release type. |
| 30 | Supply, fixing and replacement of MCB SP 40 Amp, 10 KA 240 Volt 'C' series complete all as directed by Engineer-in-Charge. |
| 31 | M&L for end outdoor/indoor jointing kit suitable for 4 to 16 sqmm 3.5 /4 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable including taking down of existing kit, complete all as specified and directed. |
| 32 | M&L for end outdoor/indoor jointing kit suitable for 25 to 50 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable including taking down of existing kit, complete all as specified and directed. |
| 33 | M&L for end outdoor/indoor jointing kit suitable for 70 to 150 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable including taking down of existing kit, complete all as specified and directed. |
| 34 | M&L for end outdoor/indoor jointing kit suitable for 185 to 300 sqmm 3.5 core XLPE/ PVC Cable 1100 volts grade, heat shrinkable type for indoor/ outdoor applications complete including preparing ends of cable including taking down of existing kit, complete all as specified and directed. |
| 35 | M&L for earthing complete with galvanized steel earth plate electrodes 600mmx600mmx6 mm thick buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel all as specified & shown in electrical plate No.3 of MES SSR part-I 2010 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of strata incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal , salt, funnel, all as directed at site. Note : 1) Rate included for excavation & earth work in any type of strata as shown in electric plate no-3 in SSR Part-I. 2) Rate included for dismantling of old earth pit and removal from site. |
| 36 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 600 amps duly insulated by insulation of RYB colour 600 Amps rating mounted on porcelain insulators. The panels shall be factory made and minimum size of panel 1.5 mtrs x 1.2 mtrs x 0.5 mtrs, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge including dismantling of existing panel and comprising of the following:- |
| 37 | (A) IN COMING:- (a) MCCB 4 Pole 415 Volts 36 KA 400 Amp rating microprocessor adjustable release type with Extended handle, lock & key arrangement including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 38 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 39 | (c) Panel mounted multi function three phase VIF energy (VLN, VLL, I1, I2, I3, F) Three Row, four Digit meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 NoNote: Contractor may be visit the site before quoting the rate and work has to be completed upto entire satisfaction of Engr-in-Charge. |
| 40 | (B) OUT GOING:- (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 41 | (b) MCCB 4 Pole 415 Volts 36 KA 200 Amp rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 Nos |
| 42 | (c) MCCB 4 Pole 415 Volts 25 KA 160 Amp rating microprocessor adjustable release type including spreaders , nut, bolts, lugs etc (Icu=Ics=100%) -02 No |
| 43 | MCCB 4 Pole 415 Volts 16 KA 100 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 44 | (e) MCB 32 Amp 'C' series TPN including , nut, bolts, lugs etc -02 Nos |
| 45 | Supply, install, testing and commissioning of LT Panel board, outdoor type, gable roof, floor mounted, factory made (CPRI approved) suitable for 415 volt, 3 PH, 4 wire, 50 HZ, AC supply system having bus bars chamber with copper bus bars of rating 200 amps duly insulated by insulation of RYB colour 200 Amps rating mounted on porcelain insulators. The panels shall be factory made,and minimum size of panel 1.5 mtrs x 1.2 mtrs x 0.5 mtrs, double door, made out of 3.15 mm thick MS sheet totally enclosed dust, vermin and rust proof front operated, front and rear opening with locking arrangement fixed with MS angle iron frame of size 40X40X5 mm and including of lowers on both sides including embedding the panel in PCC platform and duly painted with two coats of synthetic enamel paint over a coat of red oxide primer with colour as directed and including danger board and including internal wiring with multistranded copper conductor cable of suitable size incl lugs and cable gland to incoming and outgoing cable with 3 butt hinges to panel doors and locking arrangement as desired complete all as directed by Engr-in-charge including dismantling of existing panel and comprising of the following:- |
| 46 | (A) IN COMING:- (a) MCCB 4 Pole 415 Volts 36 KA 250 Amp rating microprocessor adjustable release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 47 | (b) RYB indicating lamp LED type suitable for panel mounting (Set of three) - 01 No. |
| 48 | (c) Panel mounted multi function energy (voltmeter & ammeter) meter of accuracy CL-1.0 rating including CT of ratio 200/5 - 01 No |
| 49 | (B) OUT GOING:- (a) MCCB 4 Pole 415 Volts 16 KA 250 100 rating microprocessor adjustable release release type including spreaders, nut, bolts, lugs etc (Icu=Ics=100%) -01 No |
| 50 | (b) MCB 63 Amp TPN 'C' Series including , nut, bolts, lugs etc -03 Nos |
| 51 | Material and labour Cement concrete (1:2:4) type B -1 using 20 mm graded stone aggregate for pedestal of poles/copping including necessary frame work ,fair finishing to exposed surfaces using extra cement complete form, all as directed by EIC. |
| 52 | Material and labour for Cement concrete (1:3:6) type C -2 using 40 mm graded stone aggregate for foundation of pole /struts/stay assembly etc complete all as directed by EIC. |
| 53 | Material and labour in replacement for prestressed cement concrete poles 9 M long of size 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class-10, conforming to relavent latest IS including dismantling and refixing of cross arm, security light fittings, brackets or any other existing fittings etc connecting, testing including dismantling and removal of broken pole and coping complete all as specified and directed at site. NOTE:- (i) Earthwork, PCC will be measured and paid separately under relevant item.(ii) Removal of dismantled items from site are included in rate quoted by the contractor. |
| 54 | Dismantling of insulators any type any size from existing poles, complete all as specified and directed. |
| 55 | Supply and fix pin type porcelain insulator, vitreous white brown or green including one galvanised mild steel spindle two GI washer and GI Nuts 100 mm height 65 mm dia for 1100 volts grade, complete all as specified and directed. |
| 56 | Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 57 | Supply and fix shackle Type, porcelain, vitreous, white, brown or green insulator 1100 volt grade 75 mm in height and 90 mm dia including galvanised mild steel straps of size 31 x 3 mm, insulator bolt of 12 mm dia, washers and nut complete all as specified and as directed. Please Enable Macros to View BoQ information |