| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil complete all as specified and directed. |
| 2 | PCC 1:4:8(nominal mix) type D-2 (using 40 mm graded crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed. |
| 3 | Use and waste of formwork to sides of concrete foundation,footing,bases of columns,rafts and rafts beams ,sides and soffits (if any) of foundation and plinth beams and similar work ,vertical or to batter for fair finished surfaces of concrete complete all as spcified and directed. |
| 4 | Use and waste of formwork to sides of pillars, posts, struts, columns etc for fair finished surface of concrete, complete all as specified and directed. |
| 5 | Use and waste of formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams flat for fair finished surfaces of concrete complete all as specified and directed. |
| 6 | RCC M-25 (using 20mm graded stone aggretate) design mix for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc;complete all as specified and directed . |
| 7 | RCC M-25 (using 20mm graded stone aggretate) design mix in columns ,pillars,piers,post and struts complete all as specified and directed. |
| 8 | RCC M-25 design mix (using 20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 9 | M&L for RCC Nominal mix 1:2:4 type B1(using 20 mm graded aggregate) in chajjas complete all as specified and directed. |
| 10 | Formwork to flat chullah hoods,chajjas,troughs and similar items including edges fair finished surfaces,complete all as specified and directed. |
| 11 | M & L TMT bar 10 mm and over cut to length, bend to shape required including cranking, bending spirally for hoopings for cols, hooking ends and binding with ad including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed. |
| 12 | M & L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:6 complete all as specified and directed. |
| 14 | M&L for Brickwork with old size sub class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed. |
| 15 | Material & labour for Rendering 10 mm thick CM 1:6 on brick or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed. |
| 16 | M & L for Rendering 15 mm thick in two coats i.e. 10mm thick in CM 1:6 and 5mm thick in CM 1:4 using water proofing liquid compound as per manufacturer's instructions on other than fair faces brick or concrete surfaces and finishing surfaces even & smooth without using extra cement complete all as specified and directed.Note :- Water proofing liquid compound shall be measured and paid separately. |
| 17 | Supply only liquid water proofing liquid complete all as specified and directed. |
| 18 | Preperation of new surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant primer complete all as specified and directed. |
| 19 | S&F Pre-painted galvatume aluminum zinc coating GI based corrugated stee sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.. |
| 20 | M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, facia and fixed with self tapping screws complete all as specified and directed. |
| 21 | S&F Rolled mild steel in single stanchions or plate girder built up of one beam or channel section with flange plates,caps, bases, splices, angle brackets, cleats and other connections of Gde-E-250 A quality Fe-410 W. Complete all as specified and directed. |
| 22 | Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attatchment, confirming to Fe 290 ( gde E-165) complete all as specified and directed. |
| 23 | Roof trusses (framed) , trussed, purlins, crane gentries, rails and fastening and heavy bracket framing(Beam, tee, angle , channels, or flat sections) including distance pieces, cleats etc of Gde E-250 A quality Fe-410-W, complete all as specified and directed. |
| 24 | Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, n exc 10 Kg each brackets, confirming to Fe. 290 Gde-E-165 (Brackets over 10 Kg each to be measured under structural Steel) complete all as specified and directed. |
| 25 | S & F Mild steel bolts of Dia n Exc 12 mm , purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30 cm long. Complete all as specified and directed. |
| 26 | Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer, complete all as specified and directed.. |
| 27 | Treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 28 | Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 29 | Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 30 | Treating the soil under plinth protection at the rate of 5 litres of emulsion per squaremetre of surface area complete all as specified and directed. |
| 31 | Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 32 | M & L for hard core broken stone of gauge n.exc 63 mm deposited , spread and levelled in layers n.exc 15 cm thick, watered rammed to a true surface complete all as specified and directed. |
| 33 | M&L 75 mm thick cement concrete 1:4:8 type C-2 (using 40mm graded agg) as in Sub base all as specified and directed . |
| 34 | M&L for 25 mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in floor finished even and rought to received the topping layer complete all as specified and directed. |
| 35 | M & L for providing 75mm thick PCC (1:2:4) type B-2 using 40mm graded stone aggregate as in plinth protection including finishing the surface of concrete topping even & fair, without using extra cement complete all as specified and directed. |
| 36 | M&L Non skid ceramic white tiles 7 to 8mm thick (square /rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed. |
| 37 | M&L Coloured Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match . Complete all as specified and directed. |
| 38 | S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints , fixed to walls complete all as specified and directed. |
| 39 | S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints laid in trenches, complete all as specified and directed. |
| 40 | S&F for 110mm bore PVC (SWR) bends any radius fitting fo PVC (SWR) pipes, complete all as specified and directed. |
| 41 | S & F110 mm PVC (SWR) vent cowl, complete all as specified and directed. |
| 42 | M&L 75mm PVC floor trap, with grating including jointing with solvant cement.complete all as specified and directed. |
| 43 | S&F, 75 mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints laid in trenches, complete all as specified and directed. |
| 44 | M&L 75mm PVC Bends (any radius) complete all as specified and directed. |
| 45 | S & F 110 mm PVC (SWR) 'P' Trap fixed to PVC pipe and water closet any type, complete all as specified and directed. |
| 46 | S & F factory made single extruded WPC ( Wood Polymer composite) solid door/ window/ Ceosetory window & other frames/chowkhat of size 45x70 mm comprising of virgin pvc polymer of K value 58-60 ( Suspention Grade) calcium carbonate and natural bibres ( Wood powder/rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying pvc solvent cement and screwed with full body threaded star headed SS screw having minimum frame density of 750 Kg/Cum, Screw withdrawal streanth of 200 N ( face) & 1100 N ( Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 n/mm2 and resistance to spread of frame of class A category with property of being termite/borer proof, water/moisture proof and fire, retardand and fixed in position with MS hold fast/lungs/ss dash fasterners of required dia and length complete all as specified and directed. |
| 47 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30 mm thick comprising of virgin polymer of K value 58-60 ( suspention Grade), calcium carbonate and natural fibres ( wood power/ rice husk/wheat husk) and non toxic additives ( maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strenth of 1800 N ( face) & 900 N ( Edge), minimum compressive strenth 50 n/mm2 modulus of elasticity 850 n/mm2 and resistance to spread of flame of class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhessive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk SS screw, complete all as specified and directed. |
| 48 | M&L Plain cement concrete, M-15 (Nominal mix), type B-1 (Using 20mm graded stone aggregates) as in filling of steel chowkats or frames, cills and hold fast etc. complete all as specified and as directed. |
| 49 | S & F for floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed in floor over all length of cover plate 140mm thick complete all as specified and directed. |
| 50 | S&F butt hinges 100mm, cold rolled medium weight mild steel complete all as specified and directed. |
| 51 | S&F 125mm size, extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. |
| 52 | S&F 150mm long aluminium tower bolts (ISI Marked) extruded type complete all as specified and directed.. |
| 53 | S&F 300 mm size Aluminium sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed. |
| 54 | M&L Sheet glass, 4.8 mm thick ordinary quality and glazing with oil putty in square exc 0.5 sqm in each pane complete all as specified and directed. |
| 55 | S&F Providing and fixing tiled false ceiling of size 595 x 595mm in true horizontal level suspended on interlocking gypric metal grid of hot dipped galvanised steel section (galvanized @ 120 gsm/sqm, both side inclusive) consisting of 3600mm long main 'T' runner size 24x38mm and 0.30mm thick,1200mm long cross 'T' of size 24 x 25mm and 0.30mm thick, 600mm secondary cross 'T' of size 24 x 25mm and 0.30mm thick, bottom exposed capping of width 24mm of all T-sections shall be of 0.25mm thick PPGI, wall angle is fixed along the perimeters of the ceiling to walls, partitions or columns etc with rawl plugs and wooden screws at 300mm centers Main 'T' runners are then suspended from ceiling using GI sloted cleats of size 27x37x25x1.6m fixed to ceiling with 8mm dia and 45mm long dashfasteners, 4mm GI adjustable rods with galvanised buttrtfly level clips of size 85x30x0.8mm spaced at max 1200mm centre to centre along main 'T'and not more than 150mm from spliced joints.The last hanger at the end of each main runner should not be greater than 600mm from the adjacent wall, then 1200mm long cross 'T' is interlocked between the main 'T' at 600mm center to center to form a grid of 1200x600mm and then secondary cross 'T of length 600mm is then interlocked at middle of the 1200x600mm grid to form grids of 600x600mm. Cross tees at the ends having length more than 600mm are to be supported independently. Finally white coloured Gyproc 8mm thick Dew Drop/Granular tiles of size 595x595mm having foil on backside & PVC paper on front side wrapped around edges to be placedin grid complete all as specified and directed. |
| 56 | S & F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 57 | M & L Granite 20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 58 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) of nominal bore 15mm, complete all as specified and directed. |
| 59 | S&F Steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings(such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs,unions etc.) of nominal bore 20mm, complete all as specified and directed. |
| 60 | S&F 20mm dia gun metal ,globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and directed. |
| 61 | S&F Vitreous China wash down water closet pan and trap, (pedestal pattern) (Fixing includes bolts, 'P' and 'S' trap and connecting to drain pipe, white seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, flushing cistern and also polyethelene flushing pipe) etc complete all as specified and directed. |
| 62 | Supply of PVC 10 Ltr valvless,syphonic action type , flushing cistern, low level,white inlet, ball valve, float and handle including bracket and & supply of flush pipe of polyethylene of low or high density or PVC , 32 mm dia for low level cistern & supply of plastic water closet seat cover white , closed pattern with flat bottom and mild steel chromium plated or aluminised hinging device complete all as specified and directed. (Note:- Fixing of these items includes in item No 61) |
| 63 | Providing and fixing white vitreous china oval shaped table top wash basin of approved make, including cutting and making good the counter slab wherever required, fixing with approved quality sealant, alignment and leveling complete, including 32 mm C.P. brass waste coupling of standard pattern and All necessary brackets, screws, washers, rubber packing, jointing materials etc complete all as specified and directed. |
| 64 | S & f health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in pipe. complete all as specified and directed. |
| 65 | Supply & Fixing 600mmx450mm bevelled edge mirror of selected quality glass mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. |
| 66 | S&F vitreous china Urinal half stall type white with spreader etc, complete including making good complete all as specified and directed. |
| 67 | S&F 15mm bore Angle valves, CP fancy type (ISI marked) one way/ two way screwed down, high pressure with crutch or butterfly handle, screwed both ends (externally threaded) complete all as specified and directed. |
| 68 | PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 69 | S&F in soap dish dish type of milld steel Chromium plated and wooden/plastic cleats , complete all as specified and as directed. |
| 70 | S&F Cast copper alloy Bib taps chromium plated , with crutch or butterfly handle screwed down, screwed for 15 mm iron pipe or for brass ferrule complete all as specified and directed. |
| 71 | S&F pillar taps, cast copper alloy with capstan heads, chromium plated screwed down high pressure, with or without lettered \\"Hot\\" or \\"Cold\\" with long screwed shanks and fly nuts, screwed for 15 mm iron pipe and fixed complete all as specified and directed. |
| 72 | S&F toilet paper holder with flat recessed type stainless steel,fixed to wall with chromium plated (CP) brass screw complete all as specified and directed. |
| 73 | S&F brass cromium plated tubular towel rail, 20mm dia, 'D' type, 60cm long between flanges complete all as specified and directed. |
| 74 | S&F Rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position with PVC float ball valve 20mm dia with polythene float and fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line complete all as specified and directed. |
| 75 | Returning filling in with approved excavated earth, incl spreading leveling, watering and well ramming in layers n exc 25 cm thick in any type of soil complete all as specified and directed. |
| 76 | Removing excavated material n. exc.50mtr and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed. |
| 77 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in any type of soil complete all as specified and directed. |
| 78 | Rolling and consolidating formation surfaces in cutting with hand roller 02 to 0.5 tonne, complete all as specified and directed. |
| 79 | 100 mm thick PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) in base complete all as specified and directed. |
| 80 | Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 81 | Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade, complete all as specified and directed. |
| 82 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line,level and curvature , jointed with cement mortar 1:3 (1 Cement, 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm) including making drainage opening wherever required, complete all as specified and directed. |
| 83 | M&L PCC 1:3:6 type C-2 (using 40mm graded aggregate) in foundation, filling and mass concrete complete all as specified and directed. |
| 84 | M&L Brickwork with old size sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:3 complete all as specified and directed. |
| 85 | M&L 15mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:4 and finishing the surfaces even and smooth without using extra cement complete all as specified and directed. |
| 86 | M&L for pre cast reinforced cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in landing,cover slab etc including necessary formwork set in cement mortar 1:4 complete all as specified and directed. |
| 87 | M&L for cement concrete bed to drain pipes of thickness 100 mm and width 450 mm incl packing under and haunching against the sides of 150 mm bore drain pipes after they are laid and tested in cement concrete type D-2 ,1:4:8 (using 20mm graded aggregates) complete all as specified and directed. |
| 88 | S&F, for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 89 | Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.8 M dia X 3.0 M effective depth complete all as specified and directed. |
| 90 | M&L, Cement concrete type C-2 1:3:6 using 20 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork complete all as specified and directed. |
| 91 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed. |
| 92 | M&L 100mm thick Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 93 | M&L for 75 mm thick PCC 1:3:6, type C-2 (Using 40 mm graded crushed stone aggregate) as in Plinth protection/sub base etc and finished even without using extra cement, complete all as specified and directed. |
| 94 | M&L 50mm thick PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in flooring finished even and smooth without using extra cement complete all as specified and directed. |
| 95 | M & L Preparing of new plastered wall surface and applying two coat cement base paint on newly plastered surfaces, complete all as specified and directed. |
| 96 | Excavating in post holes in soft/loose soil (or similar holes) each n. exc 0.5 Cum getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm watering, and removing surplus soil to a distance n exc 50m and making good surface complete all as specified and directed. |
| 97 | S&F for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S grade St.-240 complete all as specified and directed. |
| 98 | S & F Rolled mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment (Fe-410-W(Gde-E-250)quality A. complete all as specified and directed. |
| 99 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath,parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand, complete and including demolition of existing tiles and removal outside the MoD land complete all as specified and as directed. |
| 100 | M&L for Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed. |
| 101 | M&L for Brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and directed. |
| 102 | M&L for 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate as in sub floor finished even and rought to received the topping layer complete all as specified and directed. |
| 103 | M&L for Coloured Glazed vitrified parking tiles of size 600mm x 600mm, 10mm thick as in floor, laid over and including 15mm screed bed in CM 1:6 including cleaning off all loose particles, dust from joints and filled the space between tiles and filling with approved Epoxy tile joint grouting material of approved make and colour matched with tile. Width of joint should be uniform 3-4 mm in whole area of tiling. After finishing the grouting wipe off excess grout material from tile surfaces, complete all as specified and directed. |
| 104 | M&L for Coloured Glazed vitrified parking tiles of size 600mm x 600mm, 10mm as in skirting/vertical surfaces, jointed in neat cement slurry and pointed with white cement and pigment to match, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 105 | M&L for Coloured Glazed vitrified parking tiles of size 600mm x 600mm, 10mm as in skirting/vertical surfaces, jointed in neat cement slurry and pointed with white cement and pigment to match, complete all as specified and directed. Please Enable Macros to View BoQ information |