| Sl. No. | Item Description |
| 1 | M&L for removing the sludge /concrete peices/bricks bats deposited inside the Sewage well circular type of dia upto 7 mtr and depth upto 20 mtr, having sludge upto 6 feet + 1.0 Feet height from the bottom of well completely by manually from inside the pipe/suction/delivery line of pump and de-watering the sewage well with pump or any other method including removing the unwanted substances like polythene bags, chappels, plastic bottles etc and disposing the sludge out of Agra Cantonment complete all as specified and directed by Engr-in-charge. Note :- (a) Contractor shall ensure the full safety of Labour working inside the well in all respect. (b) Safety belts, safety mask etc should be provided by the contractor for the persons working inside the well.(c) any T & P required will be arranged by contractor and rates are inclusive in job (d) The contractor will close the manholes at the entrance of the well so that no sewage flows into the chamber at the time of cleaning. |
| 2 | M&L for removing the sludge /concrete peices/bricks bats deposited inside the Sewage well rectangular type of size upto 500 sqm surface area, depth up to 20 mtr type having sludge upto 6 feet + 1.0 Feet height from the bottom of well completely by manually from inside the pipe/suction/delivery line of pump and de-watering the sewage well with pump or any other method including removing the unwanted substances like polythene bags, chappels, plastic bottles etc and disposing the sludge out of Agra Cantonment complete all as specified and directed by Engr-in-charge.Note :- (a) Contractor shall ensure the full safety of Labour working inside the well in all respect. (b) Safety belts, safety mask etc should be provided by the contractor for the persons working inside the well.(c) any T & P required will be arranged by contractor and rates are inclusive in job (d) The contractor will close the manholes at the entrance of the well so that no sewage flows into the chamber at the time of cleaning. |
| 3 | Material and labour for cleaning of sewage and removing of settled down sewage sludge cum mud/de-silting etc from equalisation tank/well including grit bar chamber and de-watering the equalisation tank/well with pump or any other method including removing the unwanted substances and disposing the sludge out of Agra Cantonment complete all as specified and directed by Engr-in-charge.Notes :-(a) Cleaning inner surface of tank completly by scraping with steel wire brush and removing mud and sludge collected inside the tank manually.(b) White Washing the inner surface of tank completely .(c) The contractor should ensure the safety of the labourers cleaning the tank and must have all the safety equipments with all the labourers. (d) The contractor will close the manholes at the entrance of the STP so that no sewage flows into the chamber at the time of cleaning.(e) any T & P required will be arranged by contractor and rates are inclusive in job. |
| 4 | Material and labour for cleaning of FAB reactor media chambers, tube settlers, filter feed tanks, treated water tanks, setteling tanks and clean water collection chambers by taking out Bio media and cleaning thoroughly by removing mud, grits etc manually and replacing air pipe of FAB reactor chambers complete all as specified and directed by Engr-in-charge. Notes :-(a) Cleaning inner surface of tank completly by scraping with steel wire brush and removing mud and sludge collected inside the tank manually and disposing the sludge out of Agra Cantonment complete at a distance not exceeding 50 mtr all as directed.(b) Washing with clean water and bleaching powder complete tank internally and removal of left out sludge, if any at site at a distance not exceeding 50 mtr all as directed. (c) The contractor should ensure the safety of the labourers cleaning the tank and must have all the safety equipments with all the labourers.(d) any T & P required will be arranged by contractor and rates are inclusive in job. |
| 5 | Material and labour for taking out sewage pump motor set of any type and capacity with connecting column pipe and rope for cleaning of clogged pump impeller manually after opening impeller casing and lowering of same after cleaning in to sewage well/tank by connecting column pipe and rope complete all as specified and directed by Engr-in-charge. Notes :-(a)The contractor should ensure the safety of the labourers cleaning the tank and must have all the safety equipments with all the labourers.rates are inclusive of all T&P required.(b) any T & P required will be arranged by contractor and rates are inclusive in job.(c) Complaint will be rectified within 24 hours otherwise Rs 1000 penalty will be charged for every 8 hours. |
| 6 | M & L for fiber base FAB media for development of bacterias round in shape/hexagonal devided in multi layers to increase the surface area of media (as per sample) ( MBBR Media MOC-P/P-HDPE- Virgin) complete all as specified and directed. |
| 7 | Supply & fixing in replacement tube settler media PVC hexagonal shape with angle correction of 60 degrees in the existing tube settler complete all as specified and directed |
| 8 | Material & labour for replacement of the sludge bed upper drain gate (location:-252 AD Bty STP) poly proplyene sliding type-18 nos with MS frame at STPs complete including all grouting and PCC work all as specified and directed . |
| 9 | Material & labour for replacement of the sludge bed upper drain gate (location:-WAC line STP) poly proplyene sliding type-04 nos with MS frame at STPs complete including all grouting and PCC work all as specified and directed . |
| 10 | Material & labour for cleaning of sludge formed on sludge bed (06 Nos of dry bed & sludge nalis) including taking out the solidified sludge ,cleaning of sludge passage and disposing the sludge out of Agra Cantonment complete all as specified and directed.Notes :-Complaint will be rectified within 24 hours otherwise Rs 1000 penalty will be charged for every 8 hours. |
| 11 | Material & labour for cleaning of sludge formed on sludge bed (02 Nos of dry bed & sludge nalis) including taking out the solidified sludge ,cleaning of sludge passage and disposing the sludge out of Agra Cantonment complete all as specified and directed.Notes :-Complaint will be rectified within 24 hours otherwise Rs 1000 penalty will be charged for every 8 hours. |
| 12 | Taking down old weared out rope from equalisation tank/ sewage well after disconnecting non clog submersible pump and Supply and fix in repair 3 strand nylon rope of 12mm dia good strength to weight ratio, high breaking capacity upto 29.4kn with shock load absorption capability for securing non clog submersible pump set at the bottom of equilisation tank with U clamp, nut bolts complete all as specified and directed. |
| 13 | S&F in replacement of water pressure gauge of range 0- 300 PSI with 100mm dia, duly fixed with suitable size of stainless steel pipe and control valve and fixed on existing position of plant incl taking down old U/S pressure gauge complete all as specified & directed. |
| 14 | Supply & fixing in repair MS column pipe heavy duty 150 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint throughout internally and externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees, Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewage well complete all as specified and directed. |
| 15 | Supply & fixing in repair MS column pipe heavy duty 125 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint throughout internally and externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees, Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewage well complete all as specified and directed. |
| 16 | Supply & fixing in repair MS column pipe heavy duty 100 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint throughout internally and externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees, Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewage well complete all as specified and directed. |
| 17 | Supply & fixing in repair MS column pipe heavy duty 80 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees, Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewage well complete all as specified and directed. |
| 18 | Supply & fixing in repair MS column pipe heavy duty 50 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees,Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewages well complete all as specified and directed. |
| 19 | Supply & fixing in repair MS column pipe heavy duty 40 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees,Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewages well complete all as specified and directed. |
| 20 | Supply & fixing in repair MS column pipe heavy duty 25 mm dia, conforming to IS 1239 Part-1 Heavy Class or IS 3589, duly painted with two coats of black bituminous paint externally, fixing in position by cutting/ welding/threading complete with all fittings (Tees, Bends, Elbows, flanges, nut bolts, rubber gaskets and any other fitting) & jointing material as required at site for laying in trenches/sewage well complete all as specified and directed. |
| 21 | S&F in repair cast iron non return valve ISI marked both ends flanged including rubber gasket, MS bolts, nuts, washers and testing complete all as specified and directed of the following size:- |
| 22 | (a) 100 mm dia. |
| 23 | (b) 150 mm dia. |
| 24 | S&F in repair sluice valve, Class PN-1.6 dia both end flanged with high tensile SS spindle with lock nut (gutka), ISI marked complete with jointing materials such as rubber packing, nuts, bolts & washers complete all as specified & directed. |
| 25 | (a) 100 mm dia. |
| 26 | (b) 150 mm dia. |
| 27 | S&F in repairs Cast iron butterfly valve Pressure rating PN 1.6, SS Disk with EPDM liner, Lever operated suitable for air as well as sewage water/sludge including check nut bolts, rubber gasket complete confirming to IS 13095 all as specified and as directed by Engr-in-Charge of following size.Notes:- Contractor will submit Certificate for EPDM liner and all ISI certificate before execution of work on site. |
| 28 | (a) 25 mm dia. |
| 29 | (b) 40 mm dia. |
| 30 | (a) 50 mm dia. |
| 31 | (b) 80 mm dia. |
| 32 | (c) 100 mm dia |
| 33 | (d) 150 mm dia |
| 34 | M&L for cleaning/opening the blockage in sewage line 200mm dia bore with sewage jet cleaning machine having capacity of cleaning up to 200 feet long in one attempt including earthworks complete all as specified and directed |
| 35 | M&L for cleaning/opening the blockage in sewage line 150mm dia bore with sewage jet cleaning machine having capacity of cleaning up to 200 feet long in one attempt including earthworks complete all as specified and directed |
| 36 | M&L for cleaning/opening the blockage in sewage line 100/80 mm dia bore with sewage jet cleaning machine having capacity of cleaning up to 100 feet long in one attempt including earthworks complete all as specified and directed |
| 37 | Supply, fabrication and fixing in replacement of MS channel/Angle'C' section etc conforming to GDE FE 410- W as sewage well covering jaal/net, hip and jack rafter, purlins,ladder ect where connected to common rafters and running rails fixed with other connecting plates ect including necessary welding, cutting etc and two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified. |
| 38 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the 25X 3mm GI Strip by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth strip protected by provision of GI light grade pipe 32 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2010 Part-I and connecting to CBDB’s as specified or indicated including testing on completion . |
| 39 | Taking up/down monoblock pump set of 3HP/ 5HP any make and in any position after disconnecting all electric conection and connecting pipe and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers,cutting out existing copper winding and rewinding with same size copper winding, Rematlling and balancing of shaft, replacement of gunmetal bush, Oil seal, Motor seal, all bearing, impeller and gland packing of pump set and refitting the same after the repair/replacement and fixing in original position with all necessary electric and pipe connections complete all as specified and directed.Note:- (i) After opening the Pump motor set, list of defective/unserviceable parts to be prepared jointly by Engineer-in-Charge and the contractor. (ii) The contractor shall furnish one year written guarantee from the certified date of completion of repairs of the pump motor set.(iii) Complaint will be rectified within 48 hours otherwise Rs 1000 penalty will be charged for every 8 hours. |
| 40 | Taking up/down vertical non clog sewage pump set any make and in any position alongwith column pipe from well after dewatering the well and disconnecting delivery end connection with the help of chain pully / tripod and overhauling the pump re-threading of wornout holes of studs and providing over size studs with nuts & washers,cutting out existing copper winding and rewinding with same size copper winding, Heat varnishing, Rematlling and balancing of shaft, replacement of gunmetal bush, Oil seal, Motor seal, all bearing, impeller, nut bolts and gland packing of pump set and refitting the same after the repair/replacement and lowering the pump set complete with column pipe in the well and fixing / connecting with existing delivery/suction complete and all as specified and directed of the following size. Note:- (i) After opening the Pump motor set, list of defective/unserviceable parts to be prepared jointly by Engineer-in-Charge and the contractor. (ii) The contractor shall furnish one year written guarantee from the certified date of completion of repairs of the pump motor set. (iii) Complaint will be rectified within 48 hours otherwise Rs 1000 penalty will be charged for every 8 hours |
| 41 | (a) 15 HP to 20 HP capacity |
| 42 | (b)10 HP to 12.5 HP capacity |
| 43 | (c ) 3 HP Capacity |
| 44 | M&L for repair of leakage in GI/CI/DI seawge pipe by run lead/titan joint or any necessary material as per site requirement including spun yarn caukling, necessary earth work and removing water / mud complete all as specified . |
| 45 | (a) 200 mm dia. |
| 46 | (b) 150 mm dia. |
| 47 | (c) 100 mm dia. |
| 48 | M & L for collection of treated effluent of STP (252 AD BTY STP & WAC Line STP) on monthly basis (in first week of month) in presence of SHO rep and MES rep in standard testing botles and sealing bottles after collection of sample as per standard procedure then send to Govt lab/ NABL Accredited lab for following parameters given below.Test are as follows :-Ph, BOD (Biochemical Oxygen Demand), COD (Chemical Oxygen Demand), Total Organic Carbon (TOC), Turbidity, TSS (Total Suspended Solids), TDS (Total Dissolved Solids), Temperature, Oil & Grease, Nitrogen (Total & Ammonical), Phosphates, Heavy Metals(Trace elements like Arsenic, Copper, etc), Fecal Coliforms/E. coli, Total Coliforms and comparing results to regulatory standards and submit the Testing report to MES office.Note :- (1) The sample must be collected in presence of SHO Rep and MES rep. Contractor will arrange testing bottles and maintain a register in which sample collection and testing report will be recorded with duly signed by SHO Rep and MES rep.(2) The contractor will submit Test fee reciept within 24 hrs of collection of sample.(3) Contractor will submit NABL accredition certificate for lab. |
| 49 | Taking up/down 150mm DI Pipe and Supply, laying and jointing in repair for 150 mm bore centrifugally cast (spun) ductile iron pressure pipes for water mains with socket & spigot ends conforming to IS 8329/2000 any length for classification of K7 suitable for rubber gasket joint (push on type) with cement mortar lining inside the pipe with outside zinc coating complete all including existing connection with required size of Tee or MS clamp with rubber bush as specified and directed. |
| 50 | Supply only Sodium Hypochlorite Solution 10% Industrial Grade Liquid for treatment of sewage treated water in packaging of 25 Ltrs sealed bucket not older than 03 months all as specified and directed. |
| 51 | Supply only Super 24 bioculture for Sewage treatment plant of bulk density 0.6-0.8 gr/cc, light brown color, free flowing powder ,effective Ph range 5-9,Free from- Anthrax, Salmonella, E. Coli, Plate Count: 4 x 10⁹ CFU/Gram, in packaging of 10 Kg sealed bucket not older than 03 months all as specified and directed. |
| 52 | Supply only Oxy-Super chemical for STP for reduction of BOD,COD and TSS useful in treatment of contaimenated soils and sludges yellowish or white in colour,CAS number 1305-79-9,Bulk Density 0.91 ± 0.05 g/cc, non inflammable, PH 10-12, in sealed packaging of 20 Kg bucket not older than 03 months all as specified and directed. |
| 53 | Supply and fixing in repair PVC Insulated and PVC Sheathed Industrial 2.5 sqmm 3 Core Flat Submersible Cable with Bare Bunched Copper Conductor, 99.97% pure ETP grade copper, uniform double insulation with Voltage Grade 1100 Volts as per IS:694/20103, confirming to NABL/ILAC test validation for water resistance and tensile strength all as directed by Engr-in-chargeNote:- Contractor will submit relevant IS certificates, insulation test reports, Test Reports (NABL/ILAC) Certificates from government-accredited labs validating that the cable meets the required specifications, such as water resistance and tensile strength before execution of work on site. |
| 54 | Supply and fixing in repair PVC Insulated and PVC Sheathed Industrial 4 sqmm 3 Core Flat Submersible Cable with Bare Bunched Copper Conductor, 99.97% pure ETP grade copper, uniform double insulation with Voltage Grade 1100 Volts as per IS:694/20103, confirming to NABL/ILAC test validation for water resistance and tensile strength all as directed by Engr-in-chargeNote:- Contractor will submit relevant IS certificates, insulation test reports, Test Reports (NABL/ILAC) Certificates from government-accredited labs validating that the cable meets the required specifications, such as water resistance and tensile strength before execution of work on site. |
| 55 | Supply and fixing in repair PVC Insulated and PVC Sheathed Industrial 6 sqmm 3 Core Flat Submersible Cable with Bare Bunched Copper Conductor, 99.97% pure ETP grade copper, uniform double insulation with Voltage Grade 1100 Volts as per IS:694/20103, confirming to NABL/ILAC test validation for water resistance and tensile strength all as directed by Engr-in-chargeNote:- Contractor will submit relevant IS certificates, insulation test reports, Test Reports (NABL/ILAC) Certificates from government-accredited labs validating that the cable meets the required specifications, such as water resistance and tensile strength before execution of work on site. |
| 56 | Supply and fixing systematic plan by computer print of sewage treatment plant on hard board of size 2 mtr x 1.5 mtr showing details of incoming and outgoing of water including detail of complete equipment alongwith capacity and specification all as directed at site. |
| 57 | M & L for Triming of trees,cutting of herbs and shrubs upto ground level,Cleaning of equipment by cotton waste and removing plants and other garbage material from STP Installation to nearest garbage bin not more than 2 km from site and spray of herbicide to stop growth of vegetation/trees/ herbs/shrubs and cleaning of internal road/path all as directed at site by Engr-in-Charge. |
| 58 | Supply and fix in repair 100 mm PVC Suction hose pipe green in colour all as directed at site |
| 59 | Supply & Fixing in repairs Electronic Time Relay Star-Delta single, time range 60 s 200-240V AC / 24V DC, 1 NO (Normally Open) contacts with all mounting accessories and connection copper leads complete all as specified & directed. Make: SIEMENS: 3RP1576-1NP30 or equivalent. |
| 60 | Supply & Fixing in repairs compact SIRIUS Motor Protection Circuit Breaker (MPCB), specifically in Size S00, Current Range: 3.5 – 5 A (Amps), Class 10 trip characteristic, and screw terminals for easy connection, with overload relay function with all mounting accessories and connection copper leads complete all as specified & directed. Make: SIEMENS: 3RV2111-1FA10 or equivalent. |
| 61 | Supply & Fixing in repairs compact SIRIUS Motor Protection Circuit Breaker (MPCB), specifically in Size S0,Current Range: 16-22 Amps (adjustable), Release Type: Magnetic only (no thermal), and screw terminals for easy connection, with Protection against overload and short circuits, allows switching on/off, with all mounting accessories and connection copper leads complete all as specified & directed. Make: SIEMENS: 3RV2321-4CC10 or equivalent. |
| 62 | S&F in replacement power contactor confirming to IS/ IEC 60947-4-1, type MNX18 1NO/NC, 3 pole 415 V, AC-3 range 18A, Coil Voltage 220 V AC, Coil operating band 65-120% Uc(Pick up),Coil operating band 35-50% Uc(Drop off),Rated impulse withstand voltage Uimp-8kV, Rated insulation voltage Ui-690V,click fit type of size 83mm x 45mm x 88 mm, fitting in the existing Starter Panel at STP with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 63 | S&F in replacement power contactor confirming to IS/ IEC 60947-4-1, type MNX22 1NO/NC, 3 pole 415 V, AC-3 range 22A, Coil Voltage 220 V AC, Coil operating band 65-120% Uc(Pick up),Coil operating band 35-50% Uc(Drop off),Rated impulse withstand voltage Uimp-8kV, Rated insulation voltage Ui-690V,click fit type of size 83mm x 45mm x 88 mm, fitting in the existing Starter Panel at STP with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 64 | S&F in replacement MNX Spare coils, 220 V AC, Suitable For MNX 9/12/18/22/25/32/40, 3 pole power contactor for fitting in the existing Starter Panel at STP all as specified and directed. |
| 65 | Supply, commissioning, installation & testing in replacement of Automatic DOL Starter Confirming to standard IS/IEC 60947-4-1, Type MU with Sz5 SPPR (single phase protection relay) for auto operation suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 5 HP, 3 Phase, Coil Voltage 415 Volt, fitted on sheet steel enclosure of size 205mm x 129mm x 289mm, with relay range 6-10amp, rated insulation voltage 690V, emergency off rocker switch, with in built protection against supply voltage-unbalance, phase reversal, phase unbalance, single phase protection with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 66 | Supply, commissioning, installation & testing in replacement of DOL Starter suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 3HP/ 5 HP, 3 Phase 415 Volt fitted on sheet steel enclosure with thermal over load relay, single phase preventor with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 67 | Supply, commissioning, installation & testing in replacement of Fully automatic Star Delta Starter air break type suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 7.5HP/ 12.5 HP, 3 Phase 415 Volt fitted on sheet steel enclosure with thermal over load relay, single phase preventor, Phase reversal protection, Phase unbalance protection, with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 68 | Supply, commissioning, installation & testing in replacement of Fully automatic Star Delta Starter air break type suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 15/20 HP, 3 Phase 415 Volt fitted on sheet steel enclosure with thermal over load relay, single phase preventor, Phase reversal protection, Phase unbalance protection with all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 69 | Supply, commissioning, installation & testing in replacement of fully Automatic Star-delta oil immersed motor starter suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 25 HP, 400 V, Three Phase, 50 Hz AC, motor current 33-54 amps, relay range 20-32 amps, with Heavy Wide Copper Kits and copper contacts with required oil, all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 70 | Supply, commissioning, installation & testing in replacement of fully Automatic Star-delta oil immersed motor starter suitable for submersible pump motor set/ mono block/ sewage pump set of capacity 20 HP, 400 V, Three Phase, 50 Hz AC, motor current 22-35 amps, relay range 13-21 amps, with Heavy Wide Copper Kits and copper contacts with required oil, all lugs & all auxiliary accessories including connections with suitable size Copper cable all as specified and directed. |
| 71 | S&F in repair MCCB 4 Pole, 415 V, with Microprocessor release 160 Amps with breaking capacity 36 KA alongwith Spreader terminals with ( ICS= 100% ICU) complete all as specified and directed. |
| 72 | S&F in repair MCCB 3 Pole, 415 V, with Microprocessor release 100 Amps with breaking capacity 16 KA alongwith Spreader terminals with ( ICS= 100% ICU) complete all as specified and directed. |
| 73 | S&F in repair MCCB 4 Pole, 415 V, with Microprocessor release 200 Amps with breaking capacity 36 KA alongwith Spreader terminals with ( ICS= 100% ICU) complete all as specified and directed. |
| 74 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 75 | S & F for Isolator Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 76 | S & F in replacement Isolator Triple pole and neutral rated capacity 63 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 77 | S & F in replacement Isolator Triple pole and neutral rated capacity 100 Amps, 415 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 78 | Taking down existing unserviceable Volt Meter and S&F new Volt Meter (0-500V), 3 phase, 415 volt complete all as specified and directed. |
| 79 | Taking down existing unserviceable Amp Meter and S&F new Amp Meter of 0-200 Amps with CTs complete all as specified and directed. |
| 80 | Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and getting out in hard/dense soil complete all as specified and directed. |
| 81 | Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil. |
| 82 | Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point. |
| 83 | Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I. |
| 84 | Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified. |
| 85 | S & F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core |
| 86 | S & F in repair XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sq. mm 3½ core core all as specified and directed. |
| 87 | S&F GI Pipe 40 mm dia light grade for protection of cable. |
| 88 | M&L for cement concrete (1:3:6) type C-1 (using 20mm graded stone aggregate) as in cills, copings, pole pedestals, plinth courses and the like including necessary form work, weathering, slightly rounded or chamfered angles and throating etc complete all as specified and directed. |
| 89 | Supply and fix junction box of PVC type with hinged type door locking arrangementwith IP 66 protection with integrated membranes / metric knockouts for cable entry including two Nos suitable mounting clamp of white colour suitable to accomodate one 06 A MCB SP 230 V and incoming & outgoing two cable gland as per requirement size of cable with aluminium bus bar 02 Nos of suitable size on insulator fitted in the box all as directed by Engr-in-charge. make : Hansal/Sintax/Havells |
| 90 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FR cable with stranded copper conductor of size 2.5 Sq mm nominal area and drawing into suitable size of steel conduit with 1.5 Sqmm (nominal area) stranded copper conductor FR cable as earth wire complete all as specified and as directed. Note:- Two runs of 2.5 sqmm cable,one run of 1.5 sqmm cable and one run of steel conduit 19 mm will be measured as one unit |
| 91 | M&L for preparing old painted surface of panel board by cleaning removing of the old paint by scracthing with wire bursh/sand paper etc and including denting/patching of broken/rusted surfaces etc and apply one coat of synthetic enamel paint by spray painting on inside/outside surface of panel,all as specified and directed. |
| 92 | Supply,installation,testing and commissioning of 3 HP 3 phase nonclog submersible pump motor set having suction size of 50 mm and delivery size of 40 mm with head range of 22-33 m and discharge range of 2.5-4.5 lps with mechanical seal including all necessary connections required for its installation. |
| 93 | Supply and fixing in repair LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. |
| 94 | Supply and fixing in repair LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete |
| 95 | M&L for dismantling, disconnecting the Air Blower set of capacity 10 to 15 HP, 3 phase 415 volts including disconnecting from channel frame and electrical panel for repair of Gear Box, refitting of gear box after toping up oiling, greasing, alingment of motor shaft and re-fixing/ assembling testing to make it functional complete including cleaning of all dirt, dust and including transportation to civil workshop for repair work and back to working site etc complete all as specified and directed.Note:- Worn out spares shall be replaced with new and measured & paid as supply only in respective item. |
| 96 | Supply only Pulley V Belt. |
| 97 | Supply only Suction air filter |
| 98 | Supply only Bearing Set. |
| 99 | Supply only Oil seal set |
| 100 | Supply only Gear set |
| 101 | Supply only Rotor Set |
| 102 | Supply only Pulley Bush |
| 103 | Supply only Chuck Nut |
| 104 | Supply only Twin Lobe |
| 105 | Supply only Compressor Oil |
| 106 | Supply and fixing in replacement of air flow rotameter to be installed at the existing 50/40 mm MS pipe having maximum capacity of 100 cum/hr including all necessary connection required for its installation complete all as specified and directed. |
| 107 | M&L for scraping old paint & applying one coat of superior quality synthetic enamel paint on all the air pipes and equipments within STP premises connecting to blower, aeration chamber, equalisation tank railing, media tank, tube settler, Filter media plant etc and also marking air/ water flow by painting arrows after every two feet with white paint on pipes by professional calligraphy-painter complete all as specified and directed.Note: - The colour coding for different equipments will be decided by Eng-in-charge. |
| 108 | Supply,Installation, testing & commissioning in replacment wall/floor mounted starter panel, In-door type, suitable for operation on 415volts, AC 3 Phase, 4 Wire, 50 Hz electric supply system, made out of 2.00 mm thick CRCA sheet of suitable size to acomodate all accessories /fittings, compartmentalized in construction to acomodate the incoming MCCB etc side covers with front and back hinged doors with proper locking arrangment, rubber gasket on front and back to make it dust and vermin proof with proper coated, including suitable rating of copper busbar sleeved with heat shrink sleeve colour coated for 3 hase, 4 wire electric supply system and control wiring with PVC insulated 1.5 Sqmm multi strand copper cable, complete comprising the following accessories all as directed by the Engr-in-Charge. (Locations:- Barrack road sewage well,WAC line sewage well, Sikandra line sewage well. Supply depo sewage well, RP colony sewage well)INCOMING :-160A, 4P, MCCB 25 KA with spreader link - 01 Nos.METERING:-Digital Volt Meter, 3 Phase - 01 NosDigital Amp Meter, 3 Phase - 01 NosCT : 160 / 5 A- 03 NosRYB Indicating Lamp LED type 240 V AC - 03 NosMCB SP 6A - 03 NosOUTGOING :-MCCB TPN 100 A, 25 KA with spreader link - 01 Nos |
| 109 | STAR DELTA STARTER 20 HP - 02 Set (01W+01S)Each Star Delta Starter 20 HP is consisting the following :-MCCB TPN 63 A 18 KA with spreader link - 01 NosContactor, 3 P, 40 A (AC-3) - 02 NosContactor, 3 P, 32 A (AC-3) - 01 NosMPR Relay with protection against Thermal Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe, 16-44 Amps -01 NosSingle phase preventor- 01 NosAuto manual selector Switch - 01 NosON Indicator -01 NosON / OFF Push button - 02 NosMCB SP 6A -01 NosElectronic timer - 01 NosAdd on Block (side) - 03 Nos.Note :-(1) The cost of dismantling old u/s panel and M&L for grounding of new panel to wall/floor shall be deemed to beincluded in the unit rate quoted for the item.(2) All type of test certificate with switch gears (ACB/MCCB) as per confirming to IS: 61439/2011 Part-1 and Part-2. The contractor should submit all certificates before executing the job. Make of Panel boards : ADLAC PANEL / TRICOLITE / SHALABH / ADVANCE.Make of Switch Gears : L&T / ABB / SCHNEIDER |
| 110 | M&L in replacement of Chemical dosing pump capacity 12 LPH operated on single phase 230V 50 Hz power supply, high pressure single head gear motored adjustable with self priming suitable for interchangable pump tubes and sub assemblies mechanical control adjustible from 5% to 100% with non clogging capacity pumping against pressure not less than 6kg/cm2 mounting vertical or horizontal complete with 100 ltr PE/FRP tank with lid level gauge and rain shed cowl etc including taking out old unsv pump complete all as specified and directed. |
| 111 | Supply and fix in repair Synthetic rubber insulating mat2.5 mm thick upto 11 KV for electrical purpose as per IS 15652-2006 suitable for electrical shock safety of size 2mx1mx2.5 mm thick complete all as specified and directed. Make: Jyoti or equivalent as directed by Eng-in-charge. |
| 112 | S&F portable ABC type Dry Powder Fire Extinguisher, MAP 50%, ISI Marked, BIS Approved, Class A B C Fire Safety of 5kg capacity with Wall Mount Hook and How to use Instruction Manual. |
| 113 | M&L for Mild steel, plain, black sheet 1.25mm thick in covering to equipment shade, covering to door chowkats (frames), water tanks, ducts or as per site requirement etc. cut to sizes, beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required. |
| 114 | Supply, installation, testing and commissioning in repair Automatic street light timer Panel 6 KW, factory made Conforming to IS/IEC 60947-4-1 Provided with Protection Degree IP 54, with extended wide band coil, with FRLS (Fire retardant low smoke) Internal wiring, with In-built Short-Circuit Protection, Class H Insulation, sheet metal body as a pole mountable with 32 Amp three phase Contactor, 24 Hr digital time switch, 40 Amp TPN MCB with proper lugs & terminal blocks. The panel enclosure comes complete with openable door and mounting clamps. Make: Havells IHXTS03060 or equivalent in Schneider/ L&T all as directed by Engr-in-charge. |
| 115 | Supply, installation, testing and commissioning in repair microcontroller based LT Motor protection relay with inbuilt CTs for motor, with protection against Thermal Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe, 4 selectable trip time curves for thermal overload, Test facility through front push button, Manual reset facility through front push button, With / Without fail safe mode, thermal overload Current range:- 8-22 amp, Overload trip class- 10A, 10, 20, 30, Auxiliary power supply-240 V AC +/- 20%, Contact Rated Voltage- 250 V AC / 30 V DC, Contact Rated Current- 5A, Contact Rated breaking capacity - 2000 VA / 240 W(Resistive), Dimensions (W x H x D) in mm- 70 x 85 x 106 , Din rail mounting, As per IEC 947-4-1 accuracy, IEC 60255, IEC 61000 and IEC 60068 ref standards, 1 N/O + 1 N/C – manual reset contacts with necessary connections with suitable size copper cable all as directed by Engr-in-charge.Make: L & T MPR300 or equivalent in Schneider/ Siemens |
| 116 | Supply, installation, testing and commissioning in repair microcontroller based LT Motor protection relay with inbuilt CTs for motor, with protection against Thermal Overload, Earth Fault, single Phasing, Current unbalance, Phase sequence reversal, Locked Rotor, Under Current, LED's for trip indication for each fail safe, 4 selectable trip time curves for thermal overload, Test facility through front push button, Manual reset facility through front push button, With / Without fail safe mode, thermal overload Current range:- 2-5.5 amp, Overload trip class- 10A, 10, 20, 30, Auxiliary power supply-240 V AC +/- 20%, Contact Rated Voltage- 250 V AC / 30 V DC, Contact Rated Current- 5A, Contact Rated breaking capacity - 2000 VA / 240 W(Resistive), Dimensions (W x H x D) in mm- 70 x 85 x 106 , Din rail mounting, As per IEC 947-4-1 accuracy, IEC 60255, IEC 61000 and IEC 60068 ref standards, 1 N/O + 1 N/C – manual reset contacts with necessary connections with suitable size copper cable all as directed by Engr-in-charge.Make: L & T MPR300 or equivalent in Schneider/ Siemens |
| 117 | M& L for Cleaning and preparation of LT pole by taking down/cutting vines/plant/any other shrubs complete and painting with one coat of aluminium paint including channels/ brackets , cross arms and making red & white strips with synthetic enameled paint of 30 cm height, each alternative strip upto 1.5 mtr height and writing pole numbers with yellow synthetic enameled paint after making circular base with black synthetic enameled paint and applying two coats of white wash on PCC coping complete all as specified & directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail