| 1 | Carriying out of 'B' check of DG set of capacity 160 to 320 KVA on quarterly basis through rep/ mechnic of OEM including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part 'decarbonising of battery terminals' of DG Set at different location of installation and keep ready to set for proper functioning of valve, 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc.Note :- Spares part shall be measured and paid separately under respective item of Sch A. |
| 2 | Change of Engine oil |
| 3 | Change of Engine oil filtter |
| 4 | Change of fuel filter |
| 5 | Change of Air Filter ( Inner & Outer ) |
| 6 | Change of water separator |
| 7 | Carriying out of 'B' check of DG set of capacity 62.5 to 125 KVA on quarterly basis through rep/ mech of OEM including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part 'decarbonising of battery terminals' of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc.Note :- Spares part shall be measured and paid separately under respective item of Sch A. |
| 8 | Change of Engine oil |
| 9 | Change of Engine oil filtter |
| 10 | Change of fuel filter |
| 11 | Change of Air Filter ( Inner & Outer ) |
| 12 | Change of water separator |
| 13 | Carriying out of 'B' check of DG set of capacity 7.5 to 40 KVA on quarterly basis through rep/ mech of OEM including checking, cleaning, adjusting/tightening, oiling, greasing and reseting of existing part 'decarbonising of battery terminals' of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc.Note :- Spares part shall be measured and paid separately under respective item of Sch A. |
| 14 | Change of Engine oil |
| 15 | Change of Engine oil filtter |
| 16 | Change of fuel filter |
| 17 | Change of Air Filter ( Inner & Outer ) |
| 18 | Change of water separator |
| 19 | S&F in repair of complete wiring of existing panel board including replacement of Ammeter, temprature meters, oil pressure gauge and ignition switch complete etc all as directed.for 40 KVA to 62.5 KVA DG set |
| 20 | S&F in repair of complete wiring of existing panel board including replacement of Ammeter, temprature meters, oil pressure gauge and ignition switch complete etc all as directed.for 100 KVA to 320 KVA DG set |
| 21 | M&L for taking out alternator of DG set of capacity 7.5 to 20 KVA (Make: Kirloskar/ Cummins) by dismantling from engine pulley including disconnecting electrical connection complete & transporting to workshop. Opening the rotor and stator for rewinding with copper wire of existing guage and then revarnishing the stator & rotor with good quality varnish, Heating and baking complete upto requisite duration. Check bearing & shaft for machining if reqd, Re-assemble stator & rotor by replacing existing bearings with new bearings complete. Retransportation alternator to base and coupled with engine by using new rubber bushing spider, nut bolts complete. Testing the system for smooth functioning & checking current and load output by giving existing electrical load and to the entire satisfaction of Engr-in-charge. |
| 22 | All same as per item No. 06 here-in-above, but for DG set of capacity 25 to 30 KVA Make: Kirloskar/ cummins |
| 23 | All same as per item No. 06 here-in-above, but for DG set of capacit 40 to 62.5 KVA Make: Kirloskar/ cummins |
| 24 | All same as per item No. 06 here-in-above, but for DG set of capacit 100 to 125 KVA Make: Kirloskar/ cummins |
| 25 | All same as per item No. 06 here-in-above, but for DG set of capacit 160 to 200 KVA Make: Kirloskar/ cummins |
| 26 | All same as per item No. 06 here-in-above, but for DG set of capacit 250 to 320 KVA Make: Kirloskar/ cummins |
| 27 | S&F in repair Alternator for battery charging 24 volts complete all as specified and directed.Make: Lucas / TVS / BOSCH |
| 28 | Dismantling & taking out carefully, reparing the alternator / dynamo from the engine of following capacity of DG sets with opening up, cleaning / servicing and replacement of carbon brushes with holder and assembling back, refixing and testing complete etc all as specified & directed. |
| 29 | 20 to 40 KVA capacity |
| 30 | 62.5 to 100 KVA capacity |
| 31 | 125 to 160 KVA capacity |
| 32 | 200 to 320 KVA capacity |
| 33 | Taking out carefully and repairing of fuel injection pump assembly complete from the engines of following capacity of DG sets including maintenance, servicing, replacement of valves, washers etc re-assembling calibration, setting for proper function, refixing and testing complete all as specified & directed. |
| 34 | 20 to 40 KVA capacity |
| 35 | 62.5 to 100 KVA capacity |
| 36 | 125 to 160 KVA capacity |
| 37 | 200 to 320 KVA capacity |
| 38 | Calibration of nozzles (fuel injector) of fuel injection pump assembly complete of following capacity DG sets, setting for proper functioning, refixing and testing complete etc all as specified & directed. |
| 39 | 20 to 40 KVA capacity |
| 40 | 62.5 to 100 KVA capacity |
| 41 | 125 to 160 KVA capacity |
| 42 | 200 to 320 KVA capacity |
| 43 | S&F in repair of Brass Nozzle with ring suitable size for following capacity DG sets complete all as specified & as directed |
| 44 | 40 to 160 KVA capacity |
| 45 | 200 to 320 KVA capacity |
| 46 | M&L for taking out radiator assembly from the engine base frame for cleaning all chocked tubes of raditors assembly by applying suitable chemical & re-assembling after cleaning welding, leak testing or brazing of tubes if required for repair & refixing to DG set to its original position and testing complete all as directed capacity complete etc all as specified & directed by Engineer-in-Charge for following cap of DG sets. |
| 47 | 20 to 40 KVA capacity |
| 48 | 62.5 /100 KVA capacity |
| 49 | 125 to 320 KVA capacity |
| 50 | 200 to 320 KVA capacity |
| 51 | Dismantling and taking out the necessary connection carefully from MS fuel tank of any size / type of DG set by disconnecting of fuel pipes connections, draining out of fuel from the tank, cleaning & removing sediments, dirt etc from fuel tank and replacement of fuel pipe line with highly transparent PVC flexible threaded pipes of suitable size including painting of outer surface of fuel tank with synthetic enamel paint of one coat after cleaning, scrubbing the surfaces and writing the capacity of fuel tank and marking fuel level position with synthetic enamel paint for the following DG sets. |
| 52 | 20 to 40 KVA capacity |
| 53 | 62.5/ 100 KVA capacity |
| 54 | 125 to 320 KVA capacity |
| 55 | 200 to 320 KVA capacity |
| 56 | Repair / maintenance of exhaust system including replacement of exhaust pipe, bracket with clamps, nut bolt and washer, exhaust manifold packing etc all as specified and directed by Engr - in - charge. |
| 57 | Painting of DG Sets of following capacities, comprising Engine, Alternator, LT Panel board as per standard/approved colour code with one coat of synthetic enamel paint after cleaning.scrubbing of all surfaces incl writing SM and MES Number etc all as specified and directed for:- |
| 58 | 20 to 40 KVA capacity |
| 59 | 62.5/ 100 KVA capacity |
| 60 | 125 to 160 KVA capacity |
| 61 | 200 to 320 KVA capacity |
| 62 | S & F in replacement battery terminal brass heavy duty complete etc all as specified and directed. |
| 63 | S&F in repair of self starter motor suitable for 20 KVA to 125 KVA DG set 12 Volt DC of same capacity / model / make / type including connection as per existing type and make (TVS / Lucas/BOSCH) or equivalent make and testing complete. |
| 64 | Servicing & repair to self starter of DG set of capacity 20 to 125 KVA (Make: Kirloskar) including replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete. |
| 65 | S&F in repair neon Indicator lamp for 230 volt, 50 Hz for indication to incoming and out going supply complete all as specified & directed. |
| 66 | S&F in repair over load relay 25 A, 24 Volt and 250 volt and 250 ohms complete etc all as specified and directed. |
| 67 | S&F in repair digital Amp meter size 96x96 mm to display 4 digit reading make - AE or L&T complete etc all as specified and directed. |
| 68 | S&F in repair digital volt meter size 96x96 mm to display 4 digit reading make - AE/ L&T complete etc all as specified and directed. |
| 69 | S&F in repair winding of exciter assembly for DG Set of any capacity / Make all as manufacturer design including connection and testing complete etc all as specified and directed. |
| 70 | S&F in repair diesel fuel flexible pipe for DG Set of any capacity / Make complete etc all as specified and directed. |
| 71 | S&F in repair Oil pressure pipe for DG Set of any capacity Make : Ashok Leyland complete etc all as specified and directed. |
| 72 | S&F in repair On load change over switch 4 pole, 250 Amp rating, 415 Volts, with steel enclosure and front handle type including connection lugs and testing complete etc all as specified and directed. Make-Havells/standard or equivalent |
| 73 | S&F in repair On load change over switch 4 pole, 160 Amp rating, 415 Volts, with steel enclosure and front handle type including connection with lugs and testing complete etc all as specified and directed. Make-Havells/standard or equIvalent. |
| 74 | S&F in repair Manual Change Over switch 4 pole, 200 Amp rating, 415 Volts, with steel enclosure and Side handle operated type including connection with Lugs and testing complete etc all as specified and directed. Make-Havells/standard or equIvalent. |
| 75 | M&L of Old Unsv lubricating Engine oil 20W 40 / 15 W 40, multi grade 2904C servo super for DG sets all type complete etc all as specified and directed. Make : Ashok leyland/Castrol/ Cummins/ Kirloskar/valvoline/or eq. |
| 76 | M&L Coolant for radiator in suitable container capacity complete etc make Fleetguard, Valvoline, Premium all as specified and directed. |
| 77 | M&L of Distilled water in suitable container capacity complete etc all as specified and directed. |
| 78 | S&F in repair Electric shock treatment chart coloured of size approximetely 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed. |
| 79 | S&F in repair Machinery maintenance chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed. |
| 80 | Repairing of Electrical On Load AMF panel of DG set of Capacity 62.5 to 125 KVA with repairing and replacement of minor spare parts of contractor, coil, timmer or other parts for smooth fuctioning of panel etc complete all as required and directed at site |
| 81 | Repairing of electrical On Load AMF panel of DG set of Capacity up to 160 to 320 KVA with repairing and replacement of minor spare parts of contractor, coil, timmer or other parts for smooth fuctioning of panel etc complete all as required and directed at site |
| 82 | S & F in repair of Digital display panel board of AMF PANEL including complete connecting accessories for Capacity 62.5 to 125 KVA Dg set Make : Stamford/cummins etc all as specified and directed. |
| 83 | Dismantling / taking down of unserviceable turbo charger from following DG sets and transportation to authorised workshop of respective make / brand for repair / maintenance / balancing including replacement of required parts and make the same serviceable / functional complete etc all as specified & directed.(a) 20 KVA to 62.5 KVA Capacity |
| 84 | S&F in repair Shut down valve assembly complete of following DG sets: |
| 85 | 40 to 62.5 KVA capacity |
| 86 | 100 to 125 KVA capacity |
| 87 | 160 to 320 KVA capacity |
| 88 | Repair/ Replacement of maintenance free starting battery 12 volts,150 AH etc all as specified and directed by engineer in charge.MAKE : EXIDE/ AMARON / LUCAS |
| 89 | Repair/ Replacement of maintenance free starting battery 12 volts,180AH etc all as specified and directed by engineer in charge. MAKE : EXIDE/ AMARON / LUCAS |
| 90 | Supply & Fixing in repair of hose pipe set complete with clamps of following DG sets:- |
| 91 | 62.5 to 125/160 KVA capacity |
| 92 | 200/ 250 /320 KVA capacity |
| 93 | S&F in repair Automatic voltage Regulator ( AVR) suitable for 7.5 to 40 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 94 | S&F in repair Automatic voltage Regulator (AVR) suitable for 100 to 160 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 95 | S&F in repair Automatic voltage Regulator (AVR) suitable for 200 to 320 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge. |
| 96 | Servicing & repair to self starter of DG set of capacity 100 to 320 kVA (Make: Kirloskar/ Cummins) including replacement of parts such as washer, nut, bolts, bush, solenoid, rotor etc. assembling and testing complete. |
| 97 | S&F in repair Rubber insulating mat 2 x1 mtr 19 mm thick, ISI marked 5424/69 suitable for electrical supply laid at various installations complete etc all as required and directed at site |
| 98 | S&F in repair MCCB four pole, 160 Amps, ultimate breaking cap 36 KA complete with motor break protection etc all as specified and directed. |
| 99 | S&F in repair MCCB four pole, 200 Amps, ultimate breaking cap 36 KA complete with motor break protection etc all as specified and directed. |
| 100 | S&F in repair MCCB four pole, 250 Amps, ultimate breaking cap 36 KA complete with motor break protection etc all as specified and directed. |
| 101 | Supply only Battery charger of output 12 volts and input voltage 230 V,current rating 12 Amps Double wound ammeter analog for indicating charging current A.C. mains switch On-off illuminated D.C. Output miniature circuit breaker mains switch On-off illuminated A.C. input MCB push to reset voltage & current control rottery switch connecting wires length 2 meters each - 1 set with quality battery clamps complete all as specified and directed |
| 102 | M & L for Earthing complete with galvanized steel earth plate 60cm x 60cm x 6mm thick electrode, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 32 x 6mm size up to test point by means of nuts, bolts, check nuts and washers of GI including excavation and earth work, PCC 1:3:6 type C-1 pit, 20mm bore dia GI pipe, medium grade pipe for watering arrangement and 15mm bore dia GI pipe, light grade for protection of earth wire, 50mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc. as shown in electrical Plate No. 03 of SSR Part-I connected to earthing test point including taking down old unserviceable material and testing on completion complete all as specified and as directed. |
| 103 | Supply, laying, jointing, testing of XLPE insulated outersheathed and innersheathed, galvanised steel armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, 3 ½ core, cross-sectional area 50 Sqmm and laid in trenches, pipe, ducts, including taking down existing damaged UG cable complete all as specified.Note: Earth work,excavation,cable covers and sand cushioning shall be measured and paid separately. |
| 104 | Material and labour for dry river sand cushioning over and around the cable for cable protection in trenches, levelled and punned down complete all as specified and as directed by the Engineer - in - Charge. Note: The punned down thickness shall be measured for payment. |
| 105 | Supply and laying un-reinforced precast concrete cable cover, class LV type flat size 250 mmx150mmx40 mm for protection of underground cable in trenches complete all as specified. |
| 106 | S&F 100 mm bore GI tubing light grade with necessary fittings suh as bends, tees, elbows, etc in trenches, fixed on wall complete all as specified. |
| 107 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50m in depth and getting out in soft / loose soil complete all as specified and as directed by the Engineer - in - Charge. |
| 108 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer - in - Charge. |
| 109 | Removal of excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed by the Engineer - in - Charge. Please Enable Macros to View BoQ information |