| Sl. No. | Item Description |
| 1 | M&L for painting of GI/MS pipe of undermentioned size dia incl connected fittings and valves in the pipe line for water Treatment Plant / Sewage treatment plant or any other loc by using mechnical means/ spray gun complete incl scrapping of old paint with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint of colour code as per IS 2379 incl making arrow at spacing of 5 RM of size and colour as approved by Engr-in-charge complete all as specified & directed by Engineer-in-charge. |
| 2 | (a) 50 mm bore dia |
| 3 | (b) 80 mm bore dia |
| 4 | (c) 100 mm bore dia |
| 5 | (d) 150 mm bore dia |
| 6 | (e) 200mm bore dia |
| 7 | M&L for painting of Sewage Treatment Plant motor/pumps/ blowers as under mentioned of any sizes incl scraping of old paint with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint by using syray gun approved by Engineer in Charge complete all as specified & directed by Engineer-in-charge. (a) Air blower with motor-02 Nos(b) sludge pump - 02 Nos(c) Filter press pump with motor -02 Nos(d) filter pump-02 Nos (e) press filter-01 Nos (f) Irrigation pump- 02 Nos |
| 8 | S&F joint,channel,angle,or tee sections fixed independently with welding,without connecting plates,etc,(cut to ordinary length i.e within 20mm of the length indicated) of Fe-410W (GdE-250) quality B against worn out channel ,angle iron etc complete all as specified and directed by Engr-in -charge |
| 9 | Supply only impeller as per existing of horizontal split casing type centrifugal pump of capacity upto 50 HP. |
| 10 | Ditto all as per ser item No. 4 above, but pump shaft as per existing. |
| 11 | Ditto all as per ser item No. 4 above, but wear ring as per existing. |
| 12 | Ditto all as per ser item No. 4 above, but Shaft sleeve as per existing. |
| 13 | Ditto all as per ser item No. 4 above, but Gland packing as per existing. |
| 14 | Ditto all as per ser item No. 4 above, but bearing as per existing. |
| 15 | Ditto all as per ser item No. 4 above, but impeller key as per existing. |
| 16 | M&Lin replacement by filling of virgin Biofilm media of translucent white colour, material polypropylene of density reqd in MBBR tank suitable for sewage treatment plant of size as approved by Engineer-in-Charge directed by Engineer-in-Charge.(a) Effective surface area of media Approx - 500 Sqm/Cum(b) Media ht Approx - 15 mm(c)Media dia Approx- 22 mm(d) Weight per unit surface area approx -22 mm(e) Voidage - >093 gm/Cucm(g) Media fill Range - 25-55% of volume |
| 17 | Supply & fixing in replacement DOL starter for submersible pump with 3 pole contactor, over load relay, start & stop push button & standard accessories of capacity 7.5 HP, 415 volts complete all as specified and directed. |
| 18 | M&L for scraping old paint from fire hydrant of Height 2 mtr and GI Pipe at fire fighting plant with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey by using spray gun approved suitable paint by Engineer in Charge complete all as specified .(a) 200 mm dia -25 RM (b) 150 mm dia- 20 RM(c) fire hydrant of height 2 mtr and 80 mm dia -09 Nos |
| 19 | Supply and fix in replacement cast iron sluice valve PN-1.0 with flanged ends 100 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron cap including rubber /fiber boared gasket nuts, washers etc complete all as specified and as directed by Engineer-in-Charge. |
| 20 | Supply and fix in replacement cast iron sluice valve PN-1.6 with flanged ends 150 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron cap including rubber /fiber boared gasket nuts, washers etc complete all as specified and as directed by Engineer-in-Charge. |
| 21 | Supply and fix in replacement cast iron sluice valve PN-1.6 with flanged ends 200 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron cap including rubber /fiber boared gasket nuts, washers etc complete all as specified and as directed by Engineer-in-Charge. |
| 22 | Supply & fixing in replacement butterfly valve, of size 80mm dia complete all as specified & directed. |
| 23 | Supply & fixing in replacement butterfly valve, of size 100 mm dia complete all as specified & directed. |
| 24 | Supply & fixing in replacement Pressure gauge 4\\" dial 0 to 14 Kg/Sqcm rating all specified and directed. |
| 25 | Supply & fixing in replacement gun metal globe/ gate valve with iron wheel head screwed both ends for iron pipe 32 mm bore complete all as specified and as directed by Engr-in-charge. |
| 26 | All as per the description of item ser No 20 above,here in before but 25 mm bore |
| 27 | M&L for stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 50mm dia complete all as specified & directed. |
| 28 | S & Fixing GI tubing medium grade 50mm bore in replacement (in any length) with required fitting duly laid in trenches and connecting up with water supply mains including removing unserviceable tubing complete all as specified and directed. |
| 29 | All as per the description of item ser No 23 here in before but GI pipe 80 mm bore |
| 30 | All as per the description of item ser No 23 here in before but GI pipe 40 mm bore |
| 31 | All as per the description of item ser No 23 here in before but GI pipe 15 mm bore |
| 32 | All as per item the description of item ser No 23 here in before but GI pipe 25 mm bore |
| 33 | Supply and laying in relacement Ductile iron pipe of size 150mm bore, flanged end, K-9, ISI marked including rubber gasket for flange joint, nut, bolts and washer etc complete all as specified and directed by Engineer-in-Charge. |
| 34 | M & L for taking up leaking GI pipe ,cutting threading and refixing with required duly laid in trenches and connecting with existing pipes all as specfieda and directed by EIC. |
| 35 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying CI/GI/DI pipe lines including segragation of sand, bricks and stacking complete all as specified and directed by Engineer-in-Charge. |
| 36 | Returning, filling including spreading, leveling watering and well ramming inlayers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge. |
| 37 | Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above,the starting point complete all as specified and directed by Engineer-in-charge. |
| 38 | M&L for opening of wash out sluice valve at any height of over head tank of any capacity & description drain out water and closing the same after completion of work. (Note : Rate deemed to be included of all T&P required to execute the job) |
| 39 | M& L for Cleaning of 40000 gallon capacity under ground sump at pumphouse no.1 and 2 by draining out water from the tank with portable pump sets, removing sludge, mud or any other foregin materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of white lime wash including re writing the date of cleaning, capacity of the tank etc with white flourscent white paint on black back ground complete all as specified and as directed. |
| 40 | M& L for Cleaning of 300000 litrs capacity under ground sump at pumphouse no.1 and 2 by draining out water from the tank with portable pump sets, removing sludge, mud or any other foregin materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of white lime wash including re writing the date of cleaning, capacity of the tank etc with white flourscent white paint on black back ground complete all as specified and as directed. |
| 41 | M & L for taking up /taking out submersible pump & motor of capacity 7.5 HP from bore well by disconnecting electric connections of motor and using tripod and chain pulley block, including unscrewing all column pipes of any size, any dia, any length and taking out keeping aside with nut, bolts for re-using complete all as specified and directed. |
| 42 | M & L for lowering of submersible pump motor assy incl making electric connections by making water proof joint and lowering it into bore well by using tripod and chain pulley block, including screwing all column pipes of any size, any dia, any length and tightening nut, bolts by using gaskets, testing before laying and complete testing after lowering complete all as specified and directed. |
| 43 | M&L and shifting, taking to workshop for repair and removal of burnt winding wire from motor and rewinding with new PVC insulated copper winding wire for submersible motor of same gauge and weight, including replacement of motor bush, thrust plate and reassembling the motor, well making it functional and testing complete all as specified. |
| 44 | M & L for disconnecting submersible pump from electric motor of cap 7.5 HP and taking to work shop for repair and replacement of unserviceable part such as gun metal bush, impeller and steel nuts & bolts of existing size and reassembling the pump with motor and making it functional, testing the pump to the entire satisfaction of Engr-in charge. |
| 45 | M&L for Mono block pump set 3 HP three phaseSquirrel cage Induction Motor (TEFC Type) in Rugged Cast iorn construction Motor speed 2900, Discharge flow 501 - 1000 LPM, Discharge outlet size 25 - 50 mm head 80 M and deposite old UNSV BER monoblock pump set to MES store yard complete all as specified and directed. |
| 46 | Supply & fixing lowering PVC Insulated & PVC Sheathed Industrial 3 Core 4 sqmm Flat Submersible Cables with Copper Conductor for Submersible Pump Motor with Voltage Grade Grade 1100 Volts complete all as specified and directed by Engr-in-Charge. |
| 47 | M&L for repair of unserviceable Induction Electric Motor 3 phase 1 HP to 7.5 Hp complete including checking at site, opening connections, shifting to workshop for repair, opening, rewinding with suitable gauge copper wire, varnishing for proper functioning, shifting back and refixing, re-alinging in original position the same after winding for smooth operation of motor of following capacity all as specified and directed. |
| 48 | Ditto all as per ser item No 42 above, but for motor of cap 10 HP to 20 HP. |
| 49 | Supply and fix in replacement MCB TPN 63 Amp C curve all as specified and directed. |
| 50 | supply,installation,testing,commissioning electric driven submersible motor pumping set 7.5 HP 415V,AC, 50 HZ, 3 pole suitable 200 mm dia bore Well, multistage delivery size 80 mm , discharge 630-270 LPM at 36-84 Mtr head complete all as specified and directed. |
| 51 | Supply & fixing in replacement Ball brass valves, high pressure with polythene float and flynut complete of sizes 15 mm bore complete all as specified and as directed by Engr-in-charge. |
| 52 | Supply & fixing PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified. |
| 53 | M & L for dewatering and de sludging dry or wet sludge by sucking machine/ manual method by taking out , transportation in suitable veh and depositing the same outside the MOD area to a distance 10km or as specified by engr in charge complete for the undermentioned sumps of STP are as under |
| 54 | (i) Equalization tank size 7.5mtr × 8m × 5m - |
| 55 | (ii) Oil and grease trap sizes 5.7mtr × 1.5m × 3m |
| 56 | (iii) Sludge holding tank size 5.0mtr × 3.0m × 4m |
| 57 | (iv)Aeration tanks size 8.0 mtrX 5.0 mtr x 4m |
| 58 | (v)Tube settler tank size .0 mtrx3.0 mtrx3.0 mtr |
| 59 | (vi)Chlorine contact tanks size 5.0 mtrx3.60 mtrx4.0 mtr |
| 60 | (vii)Irrigation tanks size 10.0 mtrx5.0 Mtrx4.0 mtr |
| 61 | (viii)Screen scambler tanks size 10.0 M x5.0 M x4.0 M |
| 62 | M&L for recharging of softener by provn of water softener salt (NaCl) tablet having min 99% purity complete by making liquid solution and recharging the resin as required at site as directed by Engineer-in-Charge.(Note: The weight of water softener tabet shall be measured as accounting unit for the purpose of payment) |
| 63 | M &L for Effective microorganism (EM) solution Bioculture solution having shelf ige minimum more than 6 months suitable for bacteria growth complete as required for STP plant as directed by Engr-in-Charge |
| 64 | M & L for change of fan belt for air blower No 2120. |
| 65 | M & L for change of fan belt for Filter press No. A1350/A52. |
| 66 | M & L for gear oil suitable for air blower required upto level complete. |
| 67 | Supply and use calcium hypo-chlorite liquid based high strength chlorine granule (65% to 70%) suitable to water disinfection complete all as specified and directed. |
| 68 | M& L for electromagentic flow meter suitable to measure flow 650 cum/day minimum with TEFLON lining ,operating voltage 240 V ,IP-68, with communication port complete with remote display with 7 mtrs length connecting wire suitable to be fixed on pipe size upto 80mm with all connecting flanges,rubber gaskey,nuts& bolts complete all as specified and directed. |
| 69 | M & L for free chlorine testing kit suitable for 5 min 50 test having suitable reagent ,orthotolidine/DPD with test tube ,sample test tubes having various samples of diffrenet colour to distinguish free chlorine content complete all as specified and directed. |
| 70 | M&L for brick masonary valve pit of size 900 x 900 x 900mm dimensions, one brick thick valve pit of following internal dimension with two nos. of RCC slab cover of siutable size with handle to lift atleast 75mm thick having provision of valve key slot , earth work and PCC in foundation (1:3:6) Type C2 using 40mm graded stone aggregete 150 mm thick, PCC in coping on top (1:2:4),Type B1 using 20mm graded stone agregate 100mm thick including rendering 15mm thick and two coat of white wash on exposed surfaces on external wall above,ground level incl demolition of old unserviceable existing one complete all as specified and directed by Engr-in-charge.Note: RCC slab rate are inclusive in the rates. |
| 71 | Supply and fixing Air Diffuser (silicon type) of 63mm thickness and 1000 mm length,having high temperature resistance of upto 120 Dgree celcius and high tear strength of 45 N/mm (according to ASTM D624B) complete all as specified and directed. .Make- Rehau,Type-Raubioxon plusMaxair flow-24 Nm3/Hr |
| 72 | Supply and fixing tyre coupling connected to motor and pump capacity 10 HP to 20 HP complete all as specified and directed. |
| 73 | Supply and fixing cast iron fitting or ductile iron for spigot and socket /fanged pipe such as bends (any type radius and angle) tapers any type ( straight, bends, increasing, decreasing or double socket etc) Tee pieces single branch, 'Y' junction, double branch,cross collers,caps and plugs upto 300 mm bore complete all as directed by Engineer-in-Charge |
| 74 | M&L for servicing of DG Sets 125 KVA/ 160 KVA make Cummins comprising of prime mover and alternator with accessories,control panel and connected electric circuits with various type of sensors etc complete by including checking of lubricating oil, coolant, filter, v-belt, self starter, battery power, gauges and other connected accessories, cleaning of alternator with vaccum cleaner, fault finding and rectfiying the fault by replacing the defective parts and identifying functioning of the DG Set (if any) of the following capacities complete all as specified and directed:- (a) Item comprises site visit charges for authorised technician of OEM of DG Set (or) qualified/experienced technician of DG Sets for checking, identifying the functionality of DG Set and will carry out required preventive maintenance work of DG Set and ensure smooth functioning of DG sets and connected works.(b) One service & maintenance of one DG set shall be measured & paid as one unit(c) Major spares of DG Set will be measured and paid seperately under relevent item of the CA catered as supply only.(d) Technician will carry out the required checks as per run hrs of DG set and based on timr frequency for routine checkup/servicing on date fixed (or) as and when required or direcetd by Engr-in-charge (in case of break down of DG Set).(e) Minor spares like nuts/bolts, washers, oil seal, gaskets, cotton waste, clamps shall deemed to be included in the job.(f)Spare like filter and belt,pipe kit will be paid separtely |
| 75 | S&F SPARE PARTS FOR 160/125 KVA DG SET |
| 76 | Supply only diesel filter |
| 77 | Supply only Lub Oil filter |
| 78 | Supply only Air filter |
| 79 | Supply only Fan belt |
| 80 | Supply only Diesel Pipe kit |
| 81 | Supply only Hose pipe kit |
| 82 | M&L for caliberation of fuel injection pump by authorised dealer with replacement of worn out parts, testing and commissioning complete including alignment, plunger, packing kit, spring delivery valve etc. required to make the pump serviceable of DG set of capacity 125KVA to 160 KVA. (The item rate includes transportation of pump from site to dealers workshop and back). |
| 83 | M&L for removing the radiator after disconnecting from engine, opening the parts of radiator for servicing and repairing/ replacement of unserviceable minor parts including brazing/ welding complete of DG set of capacity 125KVA to 160 KVA. (The item rate includes transportation of radiator from site to wksp and back and refixing the radiator in position). |
| 84 | Supply and fixing of Turbo Charger Assy of DG set of capacity 125KVA to 160KVA incl taking down old u/sTurbo Charger complete all as specified. |
| 85 | M&L for repair of self starter of 100 KVA to 160 KVA DG set including taking out burnt out winding, rewinding the same and replacment of burn out parts carbon brush, brushes etc (Note: The items rates incl transpotation of self startor from site /store to workshop and back to site /store |
| 86 | Supply and fixing of Water Pump Assy of DG set of capacity 100 KVA to160 KVA. |
| 87 | Supply and fix flywheel ring gear upto 125 KVA DG set |
| 88 | S&F in repair of lead acid power pack unit (battery bank) maintenance free 12 volts 180AH capacity Make Exide/Amron including taking down existing battery pack unit. |
| 89 | Supply and fixing (in replacement) CT Coil with CT Ratio 250/5A, 5VA Cl 1.0 accuracy all as per IS 2705-1992 and as specified and directed. |
| 90 | S&F (in replacement) On load change over switch 200 Amps, 415V, AC 50 Hz, front operated handle, totally enclosed in sheet metal enclosure including fixing on wall with suitable accessories and connecting the cable end with suitable size lugs, nuts/bolts/washers etc complete all as specified and directed. |
| 91 | M&L for cleaning of fuel tank, removing sludge, dirt by draining fuel and cleaning with cotton waste complete complete all as required at site complete for 125 DG Set . |
| 92 | M & L in replalcement for earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to GI earth strip size 32 x6mm as earth lead connected to earth plate by means of nut, bolts, check nut & washer of galvanized iron or of steel upto test point and GI strip 32x6mm from test point to equipment, protected by 40 mm dia GI pipe 'light grade', watering pipe 20 mm dia GI 'light grade,GI wire mesh with funnel, alternate layer of char coal and salt on all side to earth plate upto thickness of 150 mm, filling of soil in earth pit upto ground level, PCC chamber and including RCC cover including all necessary excavation & earth work, earth wire connected to main switch board, testing the earthing after completion all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 print and as directed. |
| 93 | Supply and fixing (in repairs) voltage monitoring relay (VMR), existing model for AMF panels 415 volt, AC 50 Hz all as specified and directed. |
| 94 | M&L for replacement Lub oil pressure guage 0 to 10 kg / sq cm. |
| 95 | Attending complaints of fault in DG sets up to 160 KVA having any type of fault in control, protection circuit complete for fault tracing and rectification to make DG set functional . Complaint must be attend within 3 hours after intimation to the contractor by the Department with qualified mechanic complete all as specified and directed. Notes : (i) If contractor fail to attend the complaint of DG set within 3 hours, recovery @ Rs. 500/- per hours shall be imposed upon the contractor. (ii) The spare parts shall be measured and paid separately under relevant items. |
| 96 | Taking up/ out burnt unserviceable LT cable off sizes from trenches including disconnecting all electrical connections, keeping aside old cable cover/ bricks for re-use, pulling out through pipes, under roads complete all as required at site as directed by Engr-in-charge. |
| 97 | Supply and fixing in replacement galvanised pipe light grade of dia 100 mm bore for passing of cable fixed to poles/walls/laid under floor/ roads complete with and including fittings as required compete all as specified and directed Engr-in-charge. |
| 98 | Ditto all as per ser item No 78 above, but of size 80 mm bore |
| 99 | Ditto all as per ser item No 78 above, but of size 50 mm bore |
| 100 | Ditto all as per ser item No 78 above, but of size 40 mm bore |
| 101 | Supply, laying, jointing and testing XLPE in replacement insulated and PVC sheathed steel strip/wire armoured cable, LT 1100 volt grade (heavy duty) with strandard aluminum conductor of size 6 Sqmm 2 core laid in trenches, in floor, in duct, through pipes or along the pole/along wall complete all as specified and directed by Engineer-in-charge. |
| 102 | Ditto all as per ser item No 82 above, but of size 10 sqmm 4 core |
| 103 | Ditto all as per ser item No 82 above, but of size 16 sqmm 4 core |
| 104 | Ditto all as per ser item No 82 here-in-before, but of size 25 sqmm 3.5 core |
| 105 | Ditto all as per ser item No 82 here-in-before, but of size 35 sqmm 3.5 core |
| 106 | Ditto all as per ser item No 82 here-in-before, but of size 50 sqmm 3.5 core |
| 107 | Ditto all as per ser item No 82 here-in-before, but of size 70 sqmm 3.5 core |
| 108 | Ditto all as per ser item No 82 here-in-before, but of size 95 sqmm 3.5 core |
| 109 | Ditto all as per ser item No 82 here-in-before, but of size 185 sqmm 3.5 core |
| 110 | Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed by Engineer-in-Charge. |
| 111 | Ditto all as per ser item No 91 above, but exceeding 1.5 mtr deep but not exc 3.0mtr deep. |
| 112 | Returing, filling in, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer complete all as specified and directed by Engineer-in-Charge. |
| 113 | Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above,the starting point complete all as specified and directed by Engr-in-charge. |
| 114 | M&L for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches punned down to thickness of 18mm complete all as specified. |
| 115 | Supply & laying of old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge. |
| 116 | Labour for laying of old bricks/cable retrieved in item No 96 complete incl laying bricks/ covers flat in trenches over the cable with length of brick perpendicular to direction of cable complete all as specified and as directed. |
| 117 | S & F in replacement Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6 mm from earth plate to test point and aluminium strip 25 x 3.15 mm from test point to equipment in and including GI pipe 40 mm bore light grade as protection pipe (from top of earth plate) by means of bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above,the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate of 25mm thick with 1 nos MS handles of 6/8 mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. |
| 118 | S & F in replacement Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI wire 4 mm from earth plate to test point and from test point to equipment in and including GI pipe 15 mm bore light grade as protection pipe (from top of earth plate) by means of bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick all around including top and bottom and watering pipe 20mm bore of GI pipe light grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above,the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-1 using 20mm graded crushed stone aggregate of 25mm thick with 1 nos MS handles of 6/8 mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. |
| 119 | M&L for scraping old paint from LT panels/ feeder pillars inner & outside off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint of shade as approved by Engineer-in-charge with spray machine gun from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 50mm in size complete all as specified & directed by Engineer-in-charge. |
| 120 | M & L for preperation of old painted surface of steel tubular poles any type with swan neck/ staright type/ with bracket and applying one coat of aluminium oxide paint to complete pole of height 9 mtrs complete incl applying two coats of synthetic enamel paint in black & white alternate strips of 30cm each up to 1.5 mtr height from top of PCC coping and numbering of poles in alphabets of size not less than 100 mm height all as specified & directed by Engineer-in-charge.(i) Colour for base of board and alphabets shall be decided by Engineer-in-Charge. |
| 121 | Supply and fix in repair post top lantern having powder coated die cast and spun aluminium body with clear/ opal diffuser of 25 watt min complete incl connecting with 3 core copper conductor cable all as specified and directed by Engr-in-charge. |
| 122 | M & Lin repair for MCCB 400 Amps, 4 pole, adjustable thermal magnetic release, 35 KA, Ics=Icu=100% with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed. |
| 123 | M & L in repair for MCCB 250 Amps, 4 pole, adjustable thermal magnetic release, 35 KA, Ics=Icu=100% with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed. |
| 124 | M & Lin repair for MCCB 200 Amps, 4 pole, adjustable thermal magnetic release, 25 KA, Ics=Icu=100% with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed. |
| 125 | M & L in repair for MCCB 100 Amps, 4 pole, adjustable thermal magnetic release, 16 KA, Ics=Icu=100% with phase extenders / copper links and phase separator / phase barrier complete including taking out old UNSV MCCB of any type all as specified and directed. Note for item S No 102 to 105: Make : Legrand/Hager/ ABB/ Siemens |
| 126 | M&L in repair for digital ammeter, programmable type 96x96mm complete all as speciifed and directed. |
| 127 | Supply & Fix in repair Astronomical Digital timer switch for switching on/off lights according to rising/setting of the sun with combination function for creating switching programs in which devices are switched according to astronomical time and/ or fixed preset time, current capacity 16A with 1 changeover (1 C /O ), Total 28 programs min complete in powder coated CRCA sheet enclosure/ thermoplastic enclosure of suitable thickness with MCB TPN 32 Amp - 02 nos, 3 pole contactor 32 Amp - 01 No and MCB single pole - 01 nos for manual switching of lights, fixing arrangement i.e. DIN rail complete with necessary porcelain/ DMC insulator for incoming and outgoing cable connections with reqd clamp duly painted to fix on pole complete all as specified and directed. |
| 128 | S& Fixing repair SMC/ polycarbonate material made junction box of minimum size 300 x 200 x 105 mm including side hinges suitable for pole mounting arrangements having front hinged with lockable arrangements, outdoor type, weather proof having the provision to connect incoming and outgoing cable of size 16 sqmm 2 core and one number MCB SP 10 KA, C-curve. 6 Amps, 240 Volts and suiatble fixing clamp complete all as specified and directed. |
| 129 | M&L for Steel tubular swaged poles complete with base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) including painting of poles upto 1.5 mtr height from coping with two coats of synthetic enamel paint black & white strips and numbering of poles as directed complete all as specified and directed. (PCC and earth work shall be measured & paid for separately). |
| 130 | M&L for SPD 10 KV suitable for street light / fload light fitting of cap 70 watt to 200 watt complete all as specified and directed . |
| 131 | S&F in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volt, power factor 0.90 suitable for LED street light of capacity 45 W to 60 watt complete all as specified and directed. |
| 132 | S&F in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 150 volts to 270 volt, power factor 0.95 suitable for LED street light of capacity 90 w to 120 W complete all as specified and directed. |
| 133 | M & L for replacement of TPN MCB, 240 Volts, 50 Hz, having 10 KA rupturing capacity of rating 40 Amps complete all as specified and directed. |
| 134 | M & L for replacing TPN MCB, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 63 Amps complete all as specified and directed. |
| 135 | M&L Dehydration and filtration of existing tranformer oil using transformer oil filteration cum dehydration plant to eliminate foreign particles and to improve di-electric strength upto 60 KV (min) in 2.5mm electrode gap and to bring the acidity within the permissible limit below 0.5 mg KOH / Cm complete all as specified and directed. The Record of di-electric strength of insulating oil achieved after dehydration shall be given in writting by the contractor to the dept. |
| 136 | Supply & filling of transformer insulation oil for topping up the level of oil having di-electric strength 60 KV (minimum) at a electrode gap of 2.5mm upto the required level of transformer and testing of di-electric strength of oil in transformer before and after filling. Make : Power/ Servo/ Insole/ Universal/ Savita/ Castrol conforming to relevent IS-335. Note :- (Transformer oil be supplied in sealed containers) |
| 137 | Supply & filling in replacement of breather assembly (transparent type ) heavy duty/ superior quality 500gm and fixing properly with transformer complete all as specified. |
| 138 | M&L for detecting leakage from top cover of transformer complete by removing , scraping of old worn out top gasket of main tank and fixing of new cork gasket sheeet on the tank top cover 6.0 mm thick and pasted by using suitable adhesive for the transformer of any type / make of capacity of 400 to 630 KVA including fixing the top cover with conservator,making HT & LT connections at site complete all as specified. |
| 139 | M & L for replacement of copper cable for connection in LT panels for metering and CTs of size 4 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included). |
| 140 | M & L for replacement of copper cable for connection in LT panels for metering and CTs of size 2.5 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included). |
| 141 | M & L for replacement of copper cable for connection in LT panels for metering and CTs of size 1.5 sqmm single core duly crimped with copper thimbles all as specified and directed (Cost of copper thimbles and crimping included). |
| 142 | S & F in repair LED Flood light fitting 120 watts,made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, potted Constant Current driver moisture resistant, with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and separte Surge protection device 10 KV complete having fixing bracket clamp.Note : (i) The old unserviceable LED fitting shall be issued after deducting amount as per Sch of credit at the time of RAR. (ii) The old unserviceable light fitting may be of lower wattage/ old specifications, no claim will be entertained on this account. |
| 143 | S & F in repair LED street light fitting 60 watts,made up of pressure die-cast aluminium housing with toughened clear glass with mandatory secondary optics individual lenses, with SS screws, IP-66, luminaire efficacy more than 110Lm/W, CCT 5700K ANSI, CRI>70, THD<10%, PF >0.95, LED source : Hi power LED 3 to 5W, having external potted Constant Current driver moisture resistant (installed in separate independent compartment) with internal surge protection 4KV having under voltage, over voltage, phase to phase protection and short circuit protection and auto recovery mode, operating range 150 V to 270 V AC at 50Hz, Auto Cut off >300 V and with separate external Surge protection device 10 KV suitable for fitting on 32/40mm dia bore pipe bracket including making connections with PVC insulated 3 core copper conductor cable 0.75 Sqmm min of suitable length complete all as specified .(Note : (i) The old unserviceable LED fitting shall be issued after deducting amount as per Sch of credit at the time of RAR. (ii) The old unserviceable light fitting may be of lower wattage/ old specifications, no claim will be entertained on this account. |
| 144 | M&L for Cable Jointing Kit for 11 KV grade earthed cable for indoor type termination cold shrinkable joint complete with jointing material, thimble and accessories suitable for XLPE insulated, screened, armoured aluminum conductor cable of size 95 sqm to 240 sqmm 3 core incl opening cable connections/ taking down, taking old unserviceable joint kit and re-fixing cable complete. |
| 145 | M & L for Locating & pinpointing conductor and insulation faults of low and high resistance, intermittent or flashing nature in XLPE HT/LT underground power cables of the rating 11/1.1 KV with the help of Pre-locator with time domain laptop based reflectometer/ electrometer using pulse echo method, impulse current method & decay method, and using DC high voltage surge generator to produce surge to trace route and pinpointing fault with the help of dual channel digital sound system, magnetic & acoustic for location of fault with acoustic transducer (pickup) and the amplifier with headphones, after pinpointing of faut location necessary excavation and taking out of faulty cable for repair/ replacement of joint, relaying of cable/ cover & brick protection, refilling of soil and removal of surplus soil etc at Jalandhar cantt all as specified and directed. Note: The joint shall be measured and paid separately under relevant item. The qty of item will be executed at different times during currency of contract as directed by Engr-in-Charge. Hence, contractor shall quote his rate accordingly for arranging and executing the items accordingly. A penalty of Rs 2000/- will be levied, in case contractor fails to arrange machine within 24 hrs of intimation by deptt. |
| 146 | M&L in repair for PVC insulated PVC sheathed service cable twin core having aluminium conductor of size 10 sqmm 2 core complete |
| 147 | M&L in repair for PVC insulated PVC sheathed service cable twin core having aluminium conductor of size 6 sqmm 2 core complete |
| 148 | M & L for resin cast current transformer 11kv voltage, ratio 60/5-5, dry type, insulation level 28 kv / 75 kVp, HSV :12KV, STC:18.4KA / 3sec and FREQ : 50Hz indoor type wound type ratio as core No 1. 60/5A, VA 15, class 1.0 and as core No 2 Ratio 60/5A, VA10, class 5P, ALF 10 complete shape all as per existing and specified and directed by Engr-in-charge . |
| 149 | M & L for reasin cast Voltage transformer 11kv voltage 11KV/ Sqrt3 / 110V/ Sqrt3 / 110V/ 3, dry type insulation IL 12 kv/ 28KV / 75 kVp, HSV :12KV, FREQ : 50Hz indoor type wound type insulation class B, VA 100 & class 1.0 for first core and VA 50 and class 3P for second core all as per existing shape all as specified and directed by Engr-in-charge . |
| 150 | M&L for Servicing of vaccum circuit breaker 11 KV. current cap 400/630/800 Amp by taking shut down and disconnecting electrical connections, making temporary electric supply restoration arrangement till servicing completed with reqd safety precautions complete removing of dust with blower, cleaning of all movable/ in-movable parts, checking all components, insulators/ studs with megger and replacing unserviceable parts, adjusting the male / female bushings in proper spacing, greasing all parts, tightening nuts and bolts, reconnecting all electrical connections, replacement of defective indicators lamp, any type testing, commissioning of VCB complete all as directed.Note: Major Spares replaced shall be measured and paid seperately.(a) Details of servicing of breaker :-(i) Adjustment of mechanism if required.(ii) Clean the circuit breaker to remove dust, dirt & carbon deposits. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth.(iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use electromechanical grease for the operating shaft, mating parts/contacts and bearings, and machine oil for other parts.(iv) Check for rust and wear.(v) Check Spring Tension and pitting of the Cluster Contacts.(vi) Visual check for rust and deformation.(vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. |
| 151 | (viii) Check for loosened connections, rust, damaged lead wires.(ix) Check whether the contacts are damaged by arcing.(x) Checking of control circuit & tighten the connections if any.(xi) Check close & trip coil.(xii) Checking of Jaw Contacts Conditions and repair/adjust.(xiii) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish.(b) The following test shall be carried out:-(i) Wiring testing/ checking for any short(ii) Tripping coil resistance.(iii) IR Test with megger in open and closed condition.(iv) Closing coil resistance(c) Testing of following relays of control panel with Injection Kit ,checking and programming of relay :-(i) Over current and earth fault relay(d) Testing of followig Aux relay(i) DC Supply supervision relay.(ii) Master trip relay |
| 152 | M & L for taking down old XLPE UG cable and reconnectionafter rectification of necessary defects to existing MCCB with proper thimble connection and gland to armoured connector for size 3.5 core 70 sqmm to 3.5 Core x185 sqmm complete all as specified and directed by EIC. |
| 153 | M & L for taking down old XLPE UG cable and reconnectionafter rectification of necessary defects to existing MCCB with proper thimble connection and gland to armoured connector for size 4.0 core 10 sqmm to 3.5 Core x50 sqmm complete all as specified and directed by EIC. |
| 154 | M&L for Vacuum interrupter/ Vacuum bottle suitable for 630/800 A VMX breaker. Make Crompton Greaves |
| 155 | M&L for Tripping coil 24 v DC, suitable for VCB. |
| 156 | M&L for Closing coil assy, 24 volt suitable for VCB. |
| 157 | M&L for Power pack with battery back up suitable to work on 110 volts supply. |
| 158 | M&L for Overcurrent & earth fault relay 24 V operating voltage suitable for VCB 11 KV complete having suitable RS 485 port, incl necessary programming, connections and fixing arrangement and testing complete micom P111 Schneider or equivalent all as specified and directed by Engr-in-charge. |
| 159 | M&L for Hooter alarm/ Bell for fault indication for VCB Panel |
| 160 | M&L for Push button bracket assembly. Make Crompton Greaves Cat Part No. 619/SP |
| 161 | M&L for TNC Remote switch for automatic ON/ OFF for VCB from front panel. Make L&T |
| 162 | M&L for replacement of Master trip relay 24V/110V/220V DC suitable for existing 11KV VCB complete. |
| 163 | M&L for trivector meter suitable for 11KV/rt3/110V/rt3, class 0.5s, -/5A complete with necessary connections all as specified and directed. |
| 164 | M&L for demand controller relay suitable for 11 KV VCB at complete with necessary wiring and suitable CTs & necessary connections complete for tripping to control RMD as per CMD all as specified and directed. Make : L&T/Schneider/ABB/Siemens |
| 165 | M&L for repair of RMU 11 KV 3/5 way any type & any make (Schneider, Siemens, Areva, Hartek or any other make) complete including removing/ disconnecting electric cable and earth connections from RMU, shifting the RMU from J loc through suitable transport to OEM/ authorized manufacturer/ service centre workshop at Chandigarh/ DElhi/ other suitable loc as approved by deptt and opening / step opening of RMU parts and diagnosing the fault complete including making necessary repairs, replacing complete defective AC & DC circuit control protection wiring, complete cleaning, servicing and replacing major defective parts and re-fixing, necessary repairs to gas chamber, vaccumizing and SF 6 gas filling, assembling and replacing parts for satisfactory functioning and shifting back to J1 loc Jalandhar cantt and installation, commissioning and making electrical connections complete all as directed. The major spares replaced shall be measured under relevant items of Sch. |
| 166 | M&L for load break switch assy 12KV for RMU |
| 167 | M&L for annuciator window having 12 window LED display for alarm/ trip with soft push buttons (Reset, Ack, Mute, test) complete matching to existing suitable size with necessary fixing arrangements and connections complete. |
| 168 | M&L for digital LED/ LCD display multifunction meter suitable to display kWh, PF , current , voltage parameters complete programmable type complete all as specified and directed. |
| 169 | M&L for servicing of APFC panel 415 V upto 200 KVAR cap complete including checking electric connections, capacitance & functioning of indl capacitors and functioning of relay, necessary connections, replacement of unserviceable LED indicators complete all as specified and directed. |
| 170 | M&L for Automatic power factor relay relay 8 steps with auto/manual operation , with built in metering option, suitable to be powered through AC 220 complete incl necessary connections for satisfactory functioning of APFC panel complete. |
| 171 | M&L for Auxiliary relay VAA type of make AREVA/ ALSTOM or equivalent make having 3 latch/ flag hand resetable type suitable to operate on 24 V DC complete matching to existing specs complete all as specified and directed. |
| 172 | M&L for attending of complaint for VCB 11 KV for rectification of any type of fault in mechanisam, indication, protection, metering circuit, control circuit, operating mechanism or any other mechanism or circuit within 24 hrs of intimation to make VCB in fucntional state by Engr-in-charge complete. |
| 173 | Servicing of ring main unit (RMU) 3/5 way 11 KV by taking shut down and disconnecting electrical connections, removing of dust with blower, cleaning of all movable/fixed parts, removing moisture/ hard carbon deposited due to flash over on bus bars and insulators with CRC/ Stanvac moisture/ carbon remover, checking all components, insulators/ studs, adjusting the male / female bushings in proper spacing, lubrication of moving parts, greasing all parts, tightening nuts and bolts, testing of CT & PT with suitable kit and reconnecting of all electrical connections, testing of RMU for healthiness and proper functioning and submitting report complete all as directed.Note: The Servicing/ testing shall be done by expert service engineer from manufacturer or channel partner. Contractor shall submit complete report regarding CT & PT, Protection relay functioning pick up current & corresponding time value setting tests carried with testing kit. Any major Spare replaced shall be measured and paid seperately. |
| 174 | M&L for removal of leakage from HT / LT bushing of Transformer 500 KVA complete by disconnecting electric connections, making temporary arrangement for cable connections to make elect supply functional, decanning reqd qty of oil, opening top cover and opening of rubber gaskets/ cork gasket, rubber seal and porcelain insulator of bushing rod and replacement of gasket complete for bush rod and assembling and making elect connections complete.Note: The replacement of gasket & seals of one bushing/ spindle rod shall be measured as one unit. |
| 175 | M&L for insulation mat class 'B' confirming to IS 15652-2006 of size 2.5 mm thickness x 1 Mtr width and 10 mtr length , working voltage 11KV complete all as specified and direcetd. |
| 176 | M&L for rubber mat of size 20 mm thickness , 2 Mtr length x 1 Mtr width as per IS 5424 complete all as specified and direcetd. |
| 177 | M&L fire extinguiser 9 kg Co2 type complete all as specified and directed. |
| 178 | M&L for straight through joint heat shrinkable 11 KV earthed system suitable for XLPE cable of size 3 core 120-185Sqmm incl taking down old unsv HT joint complete all as directed by Engr-in-charge . |
| 179 | M&L for cable end termination jointing kit HT 11 KV grade earthed system (cold shrinkable) indoor type complete with jointing material suitable for HT XLPE cable 120-185 sqmm 3 core 11 KV grade earthed system incl taking down old unsv HT joint complete all as directed by Engr-in-charge . |
| 180 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed. |
| 181 | M&L for PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as in pole foundation, stay pits etc including provision of necessary form work to aachieve fair finishes surfaces, complete all as specified and directed. |
| 182 | M&LPCC 1:2:4 type B-2 using 40mm graded aggregate, mechanically crushed stone for coping of pole and pit foundation etc. complete all as specified and directed. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail