| 1 | Taking up or down 15/16mm bore of KITEC/CPVC/GI pipe and connections, complete all as specified and directed. |
| 2 | Taking up or down 20mm bore of CPVC/GI pipe and connections, complete all as specified and directed. |
| 3 | Taking up or down 25mm bore of CPVC/GI pipe and connections, complete all as specified and directed. |
| 4 | S & F 15 mm bore GI tubing medium grade including with all fittings & fixtures and fixed to walls or laid in floors and including concealed pipe lines complete all as specified and directed. |
| 5 | S & F 20 mm bore GI tubing medium grade including with all fittings & fixtures and fixed to walls or laid in floors and including concealed pipe lines complete all as specified and directed. |
| 6 | S & F 25 mm bore GI tubing medium grade including with all fittings & fixtures and fixed to walls or laid in floors and including concealed pipe lines complete all as specified and directed. |
| 7 | Supplying and fixing of 20mm bore outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings to walls with hooks, ceiling or laid on floor and including concealed pipe lines complete all as specified and directed. |
| 8 | Supplying and fixing of 25mm bore outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 with all fittings to walls with hooks, ceiling or laid on floor and including concealed pipe lines complete all as specified and directed. |
| 9 | S&F in repair 15mm bore angle cock with flange cast copper alloy, chorminium plated, fancy type, screwed both ends for iron pipe or for union complete all as specified and directed |
| 10 | S&F in repair PVC connections 15 mm size with brass nuts both side of length 450 mm complete all as specified and directed . |
| 11 | S&F in repair 15mm bib taps, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 12 | S&F in repairs 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified |
| 13 | S&F in repair 15mm bore stop valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed |
| 14 | S&F in repair 20mm bore stop valve cast copper alloy with handle screwed both ends for GI out let/inlet pipe or for union including threading to existing pipes on both ends complete all as specified and directed |
| 15 | S&F in repair 15mm bore concealed stop valve chromium plated with long shank and cup concealed type for GI out let/inlet pipe or for union including threading to existing pipes on both ends (included cutting and plastering) complete all as specified and directed |
| 16 | S & F in repair Gun-metal, globe or gate valves ISI marked, 20mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed. |
| 17 | S & F in repair Gun-metal, globe or gate valves ISI marked, 25mm bore, with iron wheel head, screwed both end for iron pipe complete all as specified and directed. |
| 18 | S & F in repair CPVC ball valve / gate valve ISI marked, 20mm bore, for CPVC pipe complete all as specified and directed. |
| 19 | S & F in repair CPVC ball valve/ gate valve ISI marked, 25mm bore, for CPVC pipe complete all as specified and directed. |
| 20 | M&L for cleaning and removing all as scales and dirt, etc from tank not exc. 250 litres capacity and from mouth of circulating pipes, etc complete and washing the tanks by using bleaching powder and clean water & including reconnecting & re-fixing the same in its original position at any height of bldg with and including the following provisions complete all as directed by Engr-in-Charge:-Note. (a) writing the date of cleaning on the outer surface of the tank by paint, letters of 3cm height and width including obliterating old writing complete as directed.(b) If during tank cleaning, any blockage in internal / external pipe line has detected, the same has to be cleared including all necessary fittings (If any required at site).(c) Before tank cleaning inform to all Qtrs individuals.(d) Before the tank cleaning disconnect and re-fixing the same position. |
| 21 | All as per item No 20, but capacity exc 250 and not exc 500 litres complete all as specified and directed. |
| 22 | All as per item No 20, but capacity exc 500 and not exc 1000 litres complete all as specified and directed. |
| 23 | All as per item No 20, but capacity exc 1000 and not exc 2000 litres complete all as specified and directed. |
| 24 | M&L for petty repair to internal water / external inlet water GI pipe line n. exc. 1.0 RM of any type including socket, elbow, nipple with repair to water blockage, pipe line leakage (arreat the leakage including all fittings) including concealed water tubing etc at of any height of building by using necessary scaffolding etc. complete all as directed by Engr-in-ChargeNote for item nos.24 & 25:-a. The complaints shall be attended on the same day and complaints slip duly signed by the user will be deposited back to the JE(Civil) on the same day.b. If in case of any type of high rise buiding, repair pipe line work and other repairs required at site, then the contractor has to be arranged the ladder and scaffolding and all other safety equipments before start the work, at his own cost and nothing extra amount shall be admissible on this account |
| 25 | M&L for petty repair to internal water/external inlet / concealed water pipe line n. exc. 1 RM of any type CPVC / HDPE/ KITEC including socket, elbow, nipple with repair to water blockage, pipe line leakage (arreat the leakage including all fittings) including concealed water tubing etc at any height of building by using necessary scaffolding etc. complete all as directed by Engr-in-Charge |
| 26 | S&F in repairs 500 ltrs capacity rotatonal moulded polyethylene water storage tanks 'ISI marked' Triple layer in white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including connecting the CP brass float valve of required size, PVC tank cover incl all fittings, 20mm bore GI/PVC medium grade overflow pipe, 40mm bore GI flush pipe with plug, 15mm bore GI vent pipe and RCC staging a shown on drawings. The length of overflow pipe shall be brought upto nearest sump / outlet of rain water spouts / holes and connect to inlet and outlet pipes, tank nipple, elbow, bend, union, sockets, etc including any height of the building complete all as directed by Engr-in-Charge |
| 27 | All as per item No 26, but 1000 litres capapcity, complete all as directed by Engr-in-Charge. |
| 28 | All as per item No 26, but 2000 litres capapcity, complete all as directed by Engr-in-Charge |
| 29 | S & F in repairs of loft type water storage tank (ISI marked) of capacity 200 / 250 ltrs, hoisted and fixed in position including PTMT ball valves of 15mm dia, high pressure with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed in 15mm bore GI tube etc including taking down of old tank complete all as directed by Engr-in-Charge. Note:- GI pipe shall be measured and paid separately |
| 30 | S & F in repair Ball valves 15mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -142 gms) complete all as specified and directed. |
| 31 | S & F in repair Ball valves 20mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -210 gms) complete all as specified and directed. |
| 32 | S & F in repair Ball valves 25mm bore high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe & fixed. (minimum weight -455 gms) complete all as specified and directed. |
| 33 | S & F in repair PVC covers of PVC/ HDPE water tank suitable for 200 ltr to 2000 ltr capacity including all necessary fixing arrangement complete all as specified and directed. |
| 34 | M&L for cutting holes in brick wall built in cement mortar or cement lime mortar depth of embeded portion of hold fasts or lugs measured from the face of the jamb into the wall cutting exc. half but n. exc. one brick and making good the dismantled portion in CM 1:3 or cement concrete 1:2:4 type B-1 as required, complete all as specified and directed. |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed. |
| 36 | S&F Framed brackets of angles, I section, beams or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 (Brackets over 10 kg each to be measured under 'Structural Steel'), complete all as specified and directed |
| 37 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410-00(gde E-250) Quality A, complete all as specified and directed |
| 38 | M&L for preparation of new surfaces of steel or iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed. |
| 39 | M&L for complete demolition and removal of existing RCC / PCC water tank of any size and any dia of any description and in any position from building terrace/ over head including cleaning, wire brushing, watering, including making good to existing pillars, concretre / PCC surface including required plaster if any and removing concrete material / debris exc. .50 km but n. exc. 5 km and through out side the MD land, complete all as specified and directed.Note:- During the demolition, the contractor has to be arranged the ladder and scaffolding and all other safety equipments before start the work at his own cost and nothing extra amount shall be admissible on this account. Please Enable Macros to View BoQ information |