| 1 | Dismantling and taking down old ACSR conductor of any size from LT/HT poles incl earth continuity wire etc. complete all as specified and directed by Engineer-in-Charge. |
| 2 | Dismantling and taking down old channels/angle irons of any size from LT/HT poles incl disconnect nut, bolts etc. complete all as specified and directed by Engineer-in-Charge |
| 3 | Dismantling and taking down old insulator of any size/ type from LT/HT poles complete all as specified and directed by Engineer-in-Charge |
| 4 | Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, complete all as specified and directed by Engineer-in-Charge. |
| 5 | Removal of excavated soil to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed by Engineer-in-Charge. |
| 6 | Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil, complete all as specified and directed by Engineer-in-Charge. |
| 7 | Material and labour for sand cushioning using dry and clean tibba sand in two layers, first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. Note:- Punned thickness shall be measured for payment. |
| 8 | Material and labour for laying and fixing of new un-reinforced pre-cast concrete cable covers, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed. |
| 9 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core, 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core, 10 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core, 25 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core, 35 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core, 50 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5core, 70 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core, 95 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supplying, laying, jointing and testing of under ground cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core, 120 Sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by Engineer-in-Charge. |
| 18 | Material and Labour for boring of road crossing of size 100mm dia by using trenchless technology with use of machinery equipments complete without damaging the surface at suitable depth for drawing cables/pipe lines etc. complete all as specified and directed. Note : (i) Location of boring holes shall be decided by the Engineer-in-Charge as per requirement, nothing extra shall be payable on account of variation in length of crossing of road etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different strata/different type of soil. Tenderer is hereby advised to keep in mind this aspect while quoting their rates. |
| 19 | Supplying and laying in repairs GI tubing light grade incl all accessories for encasing cables for mechanical protection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall/floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends/sockets/reducers/saddles incl necessary threading/drilling works all as specified and directed of sizes.Note :- MS works will be measured under separate item in Schedule. |
| 20 | 80 mm bore |
| 21 | 50 mm bore |
| 22 | 40mm bore |
| 23 | S&F in repair LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size upto 50 Sqmm, 3.5 core complete all as specified and directed. |
| 24 | S&F in repair LT Cable joining kit outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for LT Armoured cables of size 70 Sqmm to 120 Sqmm, 3.5 core complete all as specified and directed. |
| 25 | S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size upto 50 Sqmm 3.5 core, complete all as specified all as directed. |
| 26 | S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 70-120 Sqmm, 3.5 core, complete all as specified all as directed. Please Enable Macros to View BoQ information |
| 27 | S&F LT Cable joining kit straight through heat shrinkable type complete with joining materials suitable for LT Armoured cables of size 70-120 Sqmm, 3.5 core, complete all as specified all as directed. Please Enable Macros to View BoQ information |