Tender For E8 Tender Id -2026_Mes Name Of Work:Repair / Replacement Of Outdoor Lt Panels, Busbar Chamber And Connected Work In Ambc, Dg Navac, Old And New Mwtc, Cadet Mess Area, Offrs Residential Area, Dsc And Other Mess Area And Other Associated Wor, Kannur-Kerala
TDR : 55425423
Tender Notice
Corrigendum Details
BOQ
17 Days Left
Kannur
Kerala
Corrigendum : Tender For E8 Tender Id -2026_Mes Name Of Work:Repair / Replacement Of Outdoor Lt Panels, Busbar Chamber And Connected Work In Ambc, Dg Navac, Old And New Mwtc, Cadet Mess Area, Offrs Residential Area, Dsc And Other Mess Area And Other Associated Wor
Name of Work:- E8 Tender id -2026_MES Name of Work:REPAIR / REPLACEMENT OF OUTDOOR LT PANELS, BUSBAR CHAMBER AND CONNECTED WORK IN AMBC, DG NAVAC, OLD AND NEW MWTC, CADET MESS AREA, OFFRS RESIDENTIAL AREA, DSC AND OTHER MESS AREA AND OTHER ASSOCIATED WORKS IN INA EZHIMALA
Sl. No.
Item Description
1
Supply & fix as in repairs LT Panel board Outdoor type floor mounted free standing dust and vermin proof with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron made of 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm thick for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed with and including the following swich gears, fixtures and fitments mentioned below Busbars:-TPN- Not less than 1250 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:- (i) ACB 1000 A, 4 Pole, 50KA with with Thermal MagneticRelease (Manual Fixed type) ACB - 01 No. (ii) CT's 1000/5 -03 No. (iii)Multifuction meter -01 No (vi) Phase Indicating lamps -03 (vii) Control fuses / MCB -03 Nos Please Enable Macros to View BoQ information
2
Supply & fix as in repairs LT Panel board Outdoor type floor mounted free standing dust and vermin proof with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron made of 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm thick for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, all MCCBs must be have thermal magnetic relrase, busbar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed with and including the following swich gears, fixtures and fitments mentioned below Busbars:-TPN- Not less than 1250 A, Aluminium bus bars E91 grade, 1100 volts grade duly covered with heat shrinkable sleeves colour coded duly fixed on moulded brackets and covered all around by insulating/CRCA sheet having no exposed portion. Bus bar chamber to be selected so that it provides gap between Bus bar and heat dissipation conforming to IS standard -1 set. Incoming:- (i) ACB 1000 A, 4 Pole, 50KA with with Thermal MagneticRelease (Manual Fixed type) ACB - 01 No. (ii) CT's 1000/5 -03 No. (iii)Multifuction meter -01 No (vi) Phase Indicating lamps -03 (vii) Control fuses / MCB -03 Nos Please Enable Macros to View BoQ information
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.