| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out in any type of soil and disposal of excavated earth lead up to 50 m and lift up to 1.5m complete all as specified and directed. |
| 2 | All as per SI No. 01 above but exc 1.5m deep and n exc 3.0m deep complete all as specified and directed. |
| 3 | All as per SI No. 01 above but exc 3.0 m deep and n exc 4.5 m deep complete all as specified and directed. |
| 4 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. N exc 10 sq m on plan and n exc 1.5 m in depth and getting out any type of soil complete all as specified and directed. |
| 5 | Removing excavated material n. exc.50 mtr and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and directed. |
| 7 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foudation, drain in softloose soil an getting out complete all as specified and directed. |
| 8 | M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified and directed. |
| 9 | M&L for rendering 10 mm thick in CM 1:4 with on bricks masonry or concrete surfaces on fair faces of brick masonry, finished even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for providing cement concrete type B 1:2:4 (20 mm graded aggregate) in RCC band,beam, cantilevers, lintel over 1.5 m span. complete all as specified and directed. |
| 11 | M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 12 | M & L for TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 13 | M&L precast Reinforced cement concrete 1:2:4 Type B1 fixed in cm 1:4 in landings, cover slabs (for Drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 14 | M&L for loose filling with aggregate of broken bricks of gauge 80 to 150mm in soakage its,soakage wells etccomplete all as specified and directed. |
| 15 | M&L for loose filling with gravel of broken stone or boulder gauge 40 mm to 80 mm in each layers n exc 15cm thick spreaded, levelled and rammed incl watering complete all as specified and directed. |
| 16 | M&L for loose filling with Moorum/bajri filling in floors or paving , laid in layers n exc 15 cm thick, spread and levelled complete all as specified and directed. |
| 17 | M&L for Sand filling under floor or in foundation including watering and consolidation in floors or pavings complete all as specified and directed. |
| 18 | S&F Mild steel framed work such as grill,gratings etc. with ends of bars shouldered and/or rivetted or forgted into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed. |
| 19 | S&F mild rolled section in joist, channel, angle, or tee section fixed independently without connecting plate etc cut to ordinary length it means within 20 mm of length indicated , complete all as specified.(Gde FE-290 (Gde-E-165) , complete all as specified & directed. |
| 20 | Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer, complete all as specified and directed. |
| 21 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165, complete all as specified and directed. |
| 22 | S&F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/ cladding/ ridges/ gutter to wall, fixed with self tapping screws complete all as specified and directed. |
| 23 | Dismantling of plain or corrugated steel sheeting,any gauge,thickness,including nanital or similar pattern roof covering and M & L for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 24 | M&L for Concrete bed to drain pipes 150 mm ( thickness of bed is 150 mm & width of bed is 450 mm) bore including packing under, and haunching against the sides of pipes complete surrounding after they are laid and tested, in cement concrete 1:4:8 type D2 complete all as specified and directed. |
| 25 | S&F, for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 26 | S&F, for 150 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,Fixed to wall, complete all as specified and directed |
| 27 | S & F 150 mm bore PVC Bends (SWR) complete all as specified and directed. |
| 28 | Drilling & development of borewell of size 300 mm dia by direct rotary method generally in accordance to IS 2800-1979 (revised & amended) in all kind of soil strata including electric logging keeping sufficient space for pea gravel packing including disposal of surplus soil within 100 mtr, well ramming & stabiliszation of materials & transportation of drilling rig & other T &P to site complete all specified & directed upto 12 m depth suitable for EWR pipes of dia as catered in this work complete all as specified and directed. |
| 29 | Supply ,assembly incl jointing, lowering and fixing PVC pipe 200 mm dia including fittings and fixures complete all as specified and directed. |
| 30 | Supply , assembly incl jointing, lowering and fiing slotted PVC pipe casing 200 mm dia incl fittings and fixtures complete all as specified and directed. |
| 31 | Providing and fixing nylon filter mesh around slotted PVC casing/strainer pipe including binding with GI/SS wire complete all as specified and directed |
| 32 | S&F of PVC well cap of 200 mm dia of pipe at the top of casing pipe of bore well with locking arrangement complete all as specified and directed. |
| 33 | S&F of PVC bail plug of 200 mm dia of pipe at the top of casing pipe of bore well with fixing arrangement complete all as specified and directed. |
| 34 | S & F Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 of Gde E-165, complete all as specified and directed. |
| 35 | Supply only for chainlink fencing of MS galvanised wire any type or size complete all as specified and directed. |
| 36 | Fixing only chainlink fencing including line wires, any mesh, size and type to any type of standards, rails,straining bolts,etc including provission of binding wire complete all as specified and directed. |
| 37 | M&L, Cement concrete type C-2 1:3:6 using 20 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork complete all as specified and directed. |
| 38 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends complete all as specified and directed. |
| 39 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15 cm deep and getting out in any type of Soil complete all as specified and directed. |
| 40 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 41 | M&L 75 mm thick plain cement concrete type B-2 1:4:8 (using 40 mm graded aggregate) as in floor complete all as specified and directed. |
| 42 | M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade, complete all as specified and directed . |
| 43 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, lintels upto 1.5 m span,coping,fillets,bed plates,plinth courses,seismic bands and the like finished fair and even including necessary formwork complete all as specified . |
| 44 | Drilling & development of borewell of size 300 mm dia by direct rotary method generally in accordance to IS 2800-1979 (revised & amended) in all kind of soil strata including electric logging keeping sufficient space for pea gravel packing including disposal of surplus soil within 100 mtr, well ramming & stabiliszation of materials & transportation of drilling rig & other T &P to site complete all specified & directed upto 12 m depth suitable for PVC pipes of dia as catered in this work complete all as specified and directed. |
| 45 | Supply ,assembly incl jointing, lowering and fixing PVC pipe 150 mm dia including fittings and fixures complete all as specified and directed. |
| 46 | Supply , assembly incl jointing, lowering and fiing slotted PVC pipe casing 150 mm dia incl fittings and fixtures complete all as specified and directed. |
| 47 | S&F of PVC well cap of 150 mm dia of pipe at the top of casing pipe of bore well with locking arrangement complete all as specified and directed. |
| 48 | S&F of PVC bail plug of 150 mm dia of pipe at the top of casing pipe of bore well with fixing arrangement complete all as specified and directed. |
| 49 | Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) including tiles (if any) complete all as specified and directed. |
| 50 | M&L for 75 mm thick PCC 1:2:4 type B-2 (40mm graded crushed stone aggregate) complete all as specified and directed. |
| 51 | M&L for chequered colour tiles of size 300x300x20mm thick or equivalent size as in machine pressed set jointed and pointed in neat cement slurry over and including screed bed 20mm thick in CM 1:4 complete all as specified and directed. |
| 52 | S&F, Rolled mild steel in roof trusses (framed),trussed, purlins, crane gantries, rail and fastening and heavy bracket framing (beam, tee,angle,channel, tubular or flat section) including distance pieces, cleats etc conforming to FE 290 (gre E-165) complete all as specified and directed. |
| 53 | S & F for Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 54 | M&L for cement concrete type C-2, 1:3:6 (40 mm graded aggregate) 75 mm thick as in plinth protection complete all as specified and directed |
| 55 | S&F Galvanised 2 strand, steel barbed wire 2.24 mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or typing at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and directed. (each line wire to be measured) |
| 56 | M&L for rendering 15mm thick in cement mortar 1:4 on fair faces of brick / concrete surfaces for fair & even finished complete all as specified and directed. |
| 57 | S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS yst - 240, complete all as specified and directed. |
| 58 | Supply lying and tessting 150mm internal dia of double wall corrugated (DWC) high density poythylene pipe (HDPE)and stiffness classes-8 (SN-8) with ISI marked (with CML no)with and including all fitting & jointin material for sewage line and laid in trenches as specified in IS-16098-2013 part 2 complete all as specified and directed. Note- bedding of pipe shall not be provided in normal condition & construction methods shall be strictly complied complete all as specified and directed. |
| 59 | S&F 150mm long and minimum 8 to 12mm dia galvanized steel anchor fastener including nut, washer and expansion sleeve for securing ms brackets of any description to wall/ ceiling of any description including drilling holes in walls with suitable drill machine & tightening the fasteners complete all as specified and directed. |
| 60 | Demolition of brick work or stone boulder masonry built in cement or cement mortar complete all as specified and directed. |
| 61 | M & L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bed by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 62 | Demolition of cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. Please Enable Macros to View BoQ information |