| 1 | Demolition of cement concrete unreinforced in Ground floor & paving not exc 15cm thickness and removal of debris from site all as specified and directed |
| 2 | M&L 100 mm thick Cement concreat type D2 (1:4:8) using 40mm graded stone aggregate as in sub base of path etc finished surface even and smooth w/o using extra cement as specified and directed. |
| 3 | M&L for pre polished coloured cement concrete chequred tile of approved quality size 300X300X 25mm thick on floors, over and including 15 mm thick screed bed CM 1:6 set and jointed in neat cement slurry and pointed with colour to match th tiles complete all as specified and directed. |
| 4 | M&L for Cement concrete 1:5:10 (using 40 mm graded granite stone aggregate) in sub base of flooring/ hard standing with interlocking paver blocks. |
| 5 | M&L for Sand filling under floors or in foundations including watering and consolidation |
| 6 | M&L for Machine pressed precast conctete interlocking paver block any shape and size conforming to IS 15658-2006 of 80 mm thickness M-40 Grade |
| 7 | M&L for Machine pressed precast conctete interlocking paver block any shape and size conforming to IS 15658-2006 of 60 mm thickness M-35 Grade |
| 8 | M&L for 100 mm thick PCC in 1:2:4 type B1 (using 40 mm graded aggregate) as in hardstanding (The PCC will be laid with 12mm expansion Gap and the gap will be filled up with bituminous joint filler type A) complete all as specified and directed. |
| 9 | M&L cement concrete in 1:3:6 Type C1(20mm graded stone aggtts)as in filling in lintels upto 1.5M clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing course, parapets and railings upto 60cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed |
| 10 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. Make : Neco, Raj, SKR, KK |
| 11 | S & F factory made pre cast RCC manhole covers conforming to IS-12592 (Medium Duty) of size as directed by engr - in charge jointed with cement mortar 1:3 (1 cement: 3 coarse sand), wherever required and all as specified.Make : Neco/ Raj/ SKR/ KK |
| 12 | M & L in repairs Reinforced concrete pipes, class NP2, of bore 300 mm dia laid and jointed complete with collars and all as specified and as directed. |
| 13 | M&L for preparation of new or previously untreated concrete/cement surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of primer. |
| 14 | Dismantaling posts/struts (wood/steel or R.C.C.) any section including taking out embeded portion and making good disturbed ground and dismanteling of PCC in base fdn all as directed by Engr-in-Charge. |
| 15 | Dismantaling posts/struts (wood/steel or R.C.C.) any section including taking out embeded portion and making good disturbed ground in natural ground base fdn all as directed by Engr-in-Charge. |
| 16 | Preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer. |
| 17 | Dismantling fencing wire mesh, barbed wire any type as directed by Engineer - in - Charge. |
| 18 | Excavation in post hole each not exc 0.50 Cum getting out returning filling in and ramming earth around in layers n.exc 25cm watering and removed surplus soil to a distance not exc 50 m in soft/ loos soil. |
| 19 | S&F Mild Steel as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165. |
| 20 | M&L for PCC type B-2(1:2:4) (using 40mm graded stone aggtts) as in mass filiing to posts of fences foundation etc all as directed by Engr-in-Charge. |
| 21 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured. |
| 22 | S&f Mild steel round bars 10mm dia and over, cut to length, bent to shape required, for securing chain link fencing including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (Fe-410W GdeE-250). |
| 23 | Supply only Chain link MS galvanisd fencing, not exceeding 4 kg per sqm any size or type complete all as specified and directed. |
| 24 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc.including provission of binding wire complete all as directed. |
| 25 | Supply, laying and fixing of galvanised punched tape concertina coil of 600mm diameter of each round/roll, complete having glavanised spring steel core wire 2.5mm dia cold drawn steel, galvanised, punched of low carbon steel having series of sharp barbs uniformly punched alongwith its length 550 Nos, barbs on periphery per revolution, crimped on steel spring core wire (stretchable length 12 meter Appx) weight 7.00 kg of each coil all as complete,incl dismantling of existing coil of any type all as specified and directed by Engr-in-Charge. |
| 26 | Demolition of brick work or stone masonry built in cement mortar all as specified and directed. |
| 27 | M & L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exe 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 28 | Taking down cement plaster of any description in any position incl racking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed. |
| 29 | M & L for rendering 15mm thick in cement mortar 1:4 on stone walls or other than fair faces of brick walls fiinished even and smooth without using extra cement complete all as specified. |
| 30 | M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of complete all as specified and directed. |
| 31 | M&L Preparation of old plastered surfaces of walls with complete removal existing treatment and applying two coats of cement base paint over a coat of primer complete all as specified and directed. |
| 32 | M&L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. of Gde Fe - 290, complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed. |
| 33 | S & F MS frame work as in grills gratings, with ends of bars shouldered and /or riveted, or forged into spikes, framed guard bars and similar works confirming to Fe290 E-165, etc.all as specified and directed |
| 34 | Dismantling AC Sheets/CGI Sheets corrugated in roof coverings including ridges all as specified and directed |
| 35 | S & F Pre painted coloured galvalume aluminium Zink coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering / Cladding to wall, fixed with self tapping screws as specified. |
| 36 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges, hips, valley gutters & fixed with self tapping screws as specified. |
| 37 | Dismantling timber scantaling 40 sq cm and over in section in any position. |
| 38 | Dismantling structural steel work including welded fabricks frames, gates, framed truss etc. |
| 39 | M&L for rolled sections as in main and cross beams/columns, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates.(Fe-410 W Gde E-250 Quality A) |
| 40 | M&L for plain cement concrete 1:3:6, type C-2 using 40 mm graded stone aggregate as in Cement concrete in surface channels and drains complete all as specified and as directed. |
| 41 | M&L for Hardcore of gauge of broken bricks n exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface Please Enable Macros to View BoQ information |