| 1 | Supply & fixing in repairs of PVC suction hose pipe 150mm dia bore complete all as specified and directed. |
| 2 | M&L for MS Clamp made out of flat iron strip fixed with and including nut bolts complete suitable for 150mm Dia PVC hose/CI/DI pipe complete all as specified and directed. |
| 3 | Supply and fixing in repairs for CI impeller suitable for 20/25 HP pump set complete all as specified and directed. |
| 4 | Supply and fixing in repairs for CI impeller suitable for 40 HP pump set complete all as specified and directed. |
| 5 | Supply and fixing in repairs for CI impeller suitable for 75 HP pump set complete all as specified and directed. |
| 6 | Supply and fixing in repairs for CI impeller suitable for 120 HP pump set complete all as specified and directed . |
| 7 | Supply and fixing in repairs for CI impeller suitable for 170 HP pump set complete all as specified and directed. |
| 8 | Supply and fixing in repairs for SS shaft suitable for 20/25 HP pump complete all as specified and directed. |
| 9 | Supply and fixing in repairs for SS shaft suitable for 40 HP pump complete all as specified and directed. |
| 10 | Supply and fixing in repairs for SS shaft suitable for 75 HP pump complete all as specified and directed. |
| 11 | Supply and fixing in repairs for SS shaft suitable for 120 HP pump complete all as specified and directed. |
| 12 | Supply and fixing in repairs for SS shaft suitable for 170 HP pump complete all as specified and directed . |
| 13 | Dismantling and taking down complete pumping set from existing foundation fixed by means of nuts, bolts and washers, disconnecting mechanically from motor coupling and suction /delivery supply line carefully complete. Taking out all unserviceable spare parts and cleaning the pump casings internally for making serviceable with and including greasing of pump as required for the following capacity of pump sets complete all as specified and directed by Engr-in-Charge. [Note : All new spares for renewal shall be measured and paid separately under item No 13 here-in-after as supply only] |
| 14 | 20/25 HP |
| 15 | 40 HP |
| 16 | 75 HP |
| 17 | 120 HP |
| 18 | 170 HP |
| 19 | M & L for metal coating for upgrading of pump shaft under size and turning the same including and making thread properly by machining work of required size of bush/ bearing etc complete all as directed for the following capacity of pumps :- |
| 20 | 20/25 HP |
| 21 | 40 HP |
| 22 | 75 HP |
| 23 | 120 HP |
| 24 | M & L for metal coating for housing case of bearing and making the same upgradation from under size, turning the same to required size suitable for 20 HP to 60 HP complete all as specified and directed. |
| 25 | M & L for metal coating for housing case of bearing and making the same upgradation from under size, turning the same to required size suitable for 75 HP to 170 HP complete all as specified and directed. |
| 26 | Supply only the following spares parts of centrifugal pumps (20 to 170 HP) of various models of make Kirloskar/Breaja/Beacon where as required. |
| 27 | Gun Metal bush for 20 HP to 60 HP(Make : Bareja/Kirloskar) |
| 28 | Gun Metal bush for 75 HP to 170 HP(Make : Bareja/Kirloskar) |
| 29 | CI diffuser for 20 HP to 60 HP (Make : Bareja/Kirloskar) |
| 30 | CI diffuser for 75 HP to 170 HP (Make : Bareja/Kirloskar) |
| 31 | MS Shaft with check nut and key for 20 HP to 75 HP (Make : Bareja/Kirloskar) |
| 32 | MS Shaft with check nut and key for 75 HP to 170 HP (Make : Bareja/Kirloskar) |
| 33 | Check nut (Make : Bareja/Kirloskar) for 20 HP to 170 HP |
| 34 | Key of impeller shaft 20 HP to 170 HP |
| 35 | CI Gland flange front and rear 20 HP to 170 HP |
| 36 | Anti vibration pad for 20 to 170 HP pumping set |
| 37 | Ball bearing 6305 (Make : SKF/NBC) |
| 38 | Ball bearing 6306 (Make : SKF/NBC) |
| 39 | Ball bearing 6309 (Make : SKF/NBC) |
| 40 | Ball bearing 6310 (Make : SKF/NBC) |
| 41 | Ball bearing 6312 (Make : SKF/NBC) |
| 42 | Ball bearing 6313 (Make SKF/NBC) |
| 43 | Ball bearing 6408 (Make : SKF/NBC) |
| 44 | Rubber coupling 8/12 holes 32 mm thick as per existing. |
| 45 | Tyre coupling as per existing. |
| 46 | Supply and fixing in repair Star coupling as per existing. |
| 47 | Dismantling of existing electric motor (3 phase 440 volt, squirrel cage, slip ring/induction motor) from foundation and disconnecting electrically and mechanically from pump coupling. Taking out the motor from starter strip re-winding by using appropriate supper quality copper winding wire of suitable guage including varnishing and insulation paper complete all as specified and directed for the following electric motors.:- [Note : All new spares for renewal shall be measured paid separately under item No 17.00 here-in- before as supply only] |
| 48 | 1/2 HP |
| 49 | 20/25 HP |
| 50 | 40 HP |
| 51 | 75 HP |
| 52 | 120 HP |
| 53 | 170 HP |
| 54 | Supply only the following spares parts of centrifugal pumps (120 HP) of various models of make Kirloskar/Breaja/Beacon where as required. |
| 55 | Diffuser with Guide vanes |
| 56 | Diffuser |
| 57 | Distance Sleeve |
| 58 | Water Deflector |
| 59 | O' Ring Set |
| 60 | S&F MS Coupling (pair) with key suitable for 20 to 170 HP motor coupled with pump complete all as specified and directed. |
| 61 | S&F Graphite gland packing 10mm to 15mm superior quality complete all as specified and directed. |
| 62 | S&F Graphite gland packing 16mm to 20mm superior quality complete all as specified and directed. |
| 63 | M&L for fully automatic star delta starter, 3 phase, 440 volts, 50 HZ, ML type with suitable relay range and contactors complete with all connections for following capacitys including taking down UNSV star delta starter from existing location and testing complete all as specified and directed. (Make: L&T / Seimens / Havells) |
| 64 | 25 HP |
| 65 | 50 HP |
| 66 | 75 HP |
| 67 | 120 HP |
| 68 | Supply and fixing PVC insulated multi stranded single core cable with copper conductor, 1100 Volts grade, conforming to IS: 694 / 1990 for the following sizes:- |
| 69 | 10 Sqmm |
| 70 | 25 Sqmm |
| 71 | M&L for painting of Centrifugal pump & motor set of capacity 20 to 25 HP including MS channels, foundations, suction and delivery pipes up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of 1st quality synthetic enamel paint with proper colour codes and writing SM No. and MES No. etc., complete all as specified and as directed. |
| 72 | M&L for painting of Centrifugal pump & motor set of capacity 40 to 75 HP including MS channels, foundations, suction and delivery pipes up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of 1st quality synthetic enamel paint with proper colour codes and writing SM No. and MES No. etc., complete all as specified and as directed. |
| 73 | M&L for painting of Centrifugal pump & motor set of capacity 120 to 170 HP including MS channels, foundations, suction and delivery pipes up to 5m length from pump sets including cleaning the outer surfaces of any description, in any position, applying one coat of 1st quality synthetic enamel paint with proper colour codes and writing SM No. and MES No. etc., complete all as specified and as directed. |
| 74 | S&F in repair, motor backeliite terminal plate having six terminal as per existing size / shape with copper alloy nut ,bolts and washers complete all as per existing size/pattern for 20/25/40 HP motor. |
| 75 | S&F in repair, motor backeliite terminal plate having six terminal as per existing size / shape with copper alloy nut ,bolts and washers complete all as per existing size/pattern for 120/170 HP motor. |
| 76 | S& F in repairs of submersible pump set for tube well with submersible motor single phase of capacity 2 HP with connected accessories including taking out and insert with complete fitting arrangements after successful repair complete all as specified and directed |
| 77 | S&F in repair MCCB , 4 pole, 250 Amps, 36 kA, 415 Volts, 50 Hz, AC and taking out existing old unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens. |
| 78 | S&F in repair MCCB 4 pole, 200 Amps, 36 kA, 415 Volts, 50 Hz, AC and taking out existing old unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens |
| 79 | S&F in repair MCCB 4 pole, 160 Amps, 36 kA, 415 Volts, 50 Hz, AC supply and taking out existing unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens |
| 80 | S&F in repair MCCB 4 pole, 125 Amps, 25 kA, 415 Volts, 50 Hz, AC supply and taking out existing unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens |
| 81 | S&F in repair MCCB 4 pole, 100 Amps, 25 kA, 415 Volts, 50 Hz, AC supply and taking out existing unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens |
| 82 | S&F in repair MCCB 4 pole, 63 Amps, 16 kA, 415 Volts, 50 Hz, AC supply and taking out existing unserviceable MCCB including electric connection & testing complete all as specified and as directed. Make: Legrand/ Schneider/ L&T/ ABB/ Siemens |
| 83 | S&F in repair for commission and testing of single phase preventer & dry run protection relay (current based), AC, 415 Volts and taking out existing unserviceable preventer including electric connection complete all as specified and as directed. Make : Minile / L&T |
| 84 | S&F in repair 3 Pole Power Contactor, 40 Amp, AC3 rating, 2 NO + 2 NC, including necessary connections for incoming and outgoing complete all as directed. Make : L&T ‘Type ML 3’ Cat No. SS90721 or equivalent. |
| 85 | S&F in repairs cast iron foot valve flanged type including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 200 mm dia pipe lines including taking out existing foot valve complete all as specified and directed. |
| 86 | S&F in repairs cast iron foot valve flanged type including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 150 mm dia pipe lines including taking out existing foot valve complete all as specified and directed. |
| 87 | S&F in repairs cast iron foot valve flanged type including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 100 mm dia pipe lines including taking out existing foot valve complete all as specified and directed. |
| 88 | S&F in repairs of sluice valve flanged type (PN-1.6) with brass spindle suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 80 mm dia pipe lines including taking out existing sluice valve complete all as specified and directed. |
| 89 | S&F in repairs of sluice valve flanged type (PN-1.6) with brass spindle suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 100 mm dia pipe lines including taking out existing sluice valve complete all as specified and directed. |
| 90 | S&F in repairs of sluice valve flanged type (PN-1.6) with brass spindle suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 150 mm dia pipe lines including taking out existing sluice valve complete all as specified and directed. |
| 91 | S&F in repairs butterfly valve flanged type (PN-1.6) with control gear suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 80 mm dia pipe lines including taking out existing butterfly valve complete all as specified and directed. |
| 92 | S&F in repairs butterfly valve flanged type (PN-1.6) with control gear suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 100 mm dia pipe lines including taking out existing butterfly valve complete all as specified and directed. |
| 93 | S&F in repairs butterfly valve flanged type (PN-1.6) with control gear suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 150 mm dia pipe lines including taking out existing butterfly valve complete all as specified and directed. |
| 94 | S&F in repairs of Cast Iron NRV flanged type (PN-1.6) suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 200 mm dia pipe lines including taking out existing NRV complete all as specified and directed(Note : Rate included all earth work, pipe cuttings and welding work) |
| 95 | S&F in repairs of Cast Iron NRV flanged type (PN-1.6) suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 150 mm dia pipe lines including taking out existing NRV complete all as specified and directed(Note : Rate included all earth work, pipe cuttings and welding work) |
| 96 | S&F in repairs of Cast Iron NRV flanged type (PN-1.6) suitable for CI/DI/MS pipe line including all jointing materials such as washers, nut bolts, rubber packing etc and testing complete all as specified ISI marked for 100 mm dia pipe lines including taking out existing NRV complete all as specified and directed(Note : Rate included all earth work, pipe cuttings and welding work) |
| 97 | Supply and installation of floats made of empty MS barrel of capacity 220 Ltrs each heavy duty (set of 02 barrel) enclosed within GI tubing 25 mm dia bore frame work welded together by arc welding for hanging foot valve of suction line including dismantiling of unserviceable float from existing position and making serviceable the system upto suction line complete all as specified and directed. |
| 98 | Rough excavation to river sand for divert water flow 8.5 mt wide,1.5 mtr depth & 40 mtr length etc and getting out in soft/loose soil at water point at RMS complete all as specified and directed by Engr-in-Charge. Note : JCB entry and exit from civil area shall be responsibility of contractor |
| 99 | Removal of surplus soil not exceeding 50 mtr and deposited where as directed at a level not exceeding 1.5 m above starting point river sand for divertion of water flow 8.5 mt wide,1.5 mtr depth & 45 mtr length etc and getting out in soft/loose soil at water point at RMS and Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 100 | M & L for filling of sand in old cement bags (approximately mass 50 kg in each bag) and shifted/dumping in river for divertion route of river as per direction of Engr-in-charge.(Note : cost of old cement bag is deemed tobe included) Please Enable Macros to View BoQ information |