| 1 | M&L for Servicing of window type AC 1.5 / 2.0 TR capacity, any type/make, by carefully taking down from window / wall, removing power connection, front PVC grill, air filters and applying air blower to remove all dust, washing, cleaning, removing dirt, including cleaning and washing of cooling and condenser coil, re-assembling the dismantled components, refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. |
| 2 | M&L for servicing of split type AC of 1.5 / 2.0 TR capacity, any type/make, in situ at installed location, removing power connection, carefully opening the indoor and outdoor unit, removing filters, applying blower in both the units to remove all dust, cleaning, washing, removing dirt, including cleaning and washing of evaporator coil of indoor cooling unit and condenser coil of outdoor unit, re-assembling the dismantled components, refixing to its original position and testing for proper functioning complete all as specified and directed by Engineer-in-Charge. |
| 3 | Supply and fix in replacement of set of PVC filters suitable for window type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 4 | Supply and fix in replacement of set of PVC filters suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 5 | Supply and fix in replacement of following spare parts suitable for indoor unit of split type AC 1.5 Ton / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 6 | Blower bush |
| 7 | Blower fan blades |
| 8 | Blower motor |
| 9 | Display unit |
| 10 | Swing motor |
| 11 | Capacitor 1.0 mdf to 2.5 mfd suitable for blower motor |
| 12 | Supply and fix in replacement of suction / discharge valve, brass, of size 1/4'' to 3/4'' suitable for outdoor unit of split type AC 1.5 Ton / 2.0 TR capacity / suction / discharge valve of package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge. |
| 13 | Supply and fix in replacement of thermostat temperature sensor suitable for indoor unit of split type AC / window type AC 1.5 Ton / 2.0 TR capacity of existing model / package type AC plant of existing model suitable for 5.5 TR / 11 TR capacity / walk-in-cooler of capacity 2.0 TR complete all as specified and directed and by Engineer-in-Charge. |
| 14 | Supply and fix in replacement of PCB with display unit suitable for window type AC 1.5 TR / 2.0 TR capacity of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 15 | Supply and fix in replacement of following spare parts suitable for window type / outdoor unit of split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 16 | Hermetically sealed reciprocating type / rotary type compressor unit 1.5 TR capacity including gas charging complete |
| 17 | Hermetically sealed reciprocating type / rotary type compressor unit 2.0 TR capacity including gas charging complete |
| 18 | Running capacitor 35 mfd to 60 mfd |
| 19 | Fan motor, copper wound |
| 20 | Fan blades |
| 21 | Fan capacitor 4.0 mfd to 6.0 mfd |
| 22 | Flair nuts of suitable sizes of existing unit |
| 23 | Supply and fix in replacement of copper condenser coil suitable for outdoor unit of 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 24 | Supply and fix in replacement of single phase contactor suitable for 1.5 / 2.0 TR capacity split type Air conditioners / Walk-in-cooler of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 25 | Supply and fix in replacement of window AC Kit, company made, consist of metal sheet enclosure / housing, cooling coil, condenser coil, PVC front grill, wiring kit, Fan motor, condenser fan and blower, PCB and remote hand set etc complete, suitable for air conditioner of 1.5 TR capacity complete all as specified and directed by Engineer-in-Charge. |
| 26 | M&L for gas charging of Air Conditioner window / split type / walk-in-cooler of capacity 1.5 / 2.0 TR with R - 22 / R-32 /R-410a or any other recommended refrigerant gas, including detecting of leakage, repairing using welding/brazing, pressure testing, replacement of connection lead, tin coated copper thimbles etc and testing for proper cooling including six month top up warranty etc complete all as specified and directed and by Engineer-in-Charge. |
| 27 | Supply and fix in replacement of copper tube of size 1/4'' to 1/2'' suitable for 1.5 / 2.0 TR capacity split type Air conditioners / walk-in-cooler / Central / package type AC of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 28 | Supply and fix in replacement of nitrile rubber foam insulation of size 1/4'' to 1/2'' suitable for 1.5 / 2.0 TR capacity split type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 29 | Supply and fix in replacement of PVC front grill suitable for 1.5 / 2.0 TR capacity window type Air conditioners of existing make / model complete all as specified and directed and by Engineer-in-Charge. |
| 30 | Supply and testing in replacement of remote control unit with batteries suitable for 1.5 / 2.0 TR capacity split type / window type Air conditioners of existing model complete all as specified and directed and by Engineer-in-Charge. |
| 31 | Supply and fix in replacement of PVC insulated and PVC sheathed 3 core x 2.5 sqmm stranded copper conductor conforming to IS:694 complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply and fix in replacement of indoor cooling unit invertor/non inverter complete with evaporator coil, blower motor with fan, PCB with display and remote control unit suitable for split air conditioner of 1.5 TR capacity with and including making connection etc complete all as specified and directed by Engineer-in-Charge. |
| 33 | All as per item No. 18.00 here-in-before but of capacity 2.0 TR. |
| 34 | Supply and fix in replacement of 20A rated metal clad plug, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply and fix in replacement of 20A rated metal clad socket, 2 pin plus earth suitable for metal clad plug & socket board, 230V, AC complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply and fix in replacement of MCB, SP, 6-32A, 'C' curve complete all as specified and directed by Engineer-in-Charge. |
| 37 | Supply and fix in replacement of Plug top, 3 pin, 20 Amps, single phase, 230 volts, 50 Hz complete all as specified and directed. |
| 38 | Supply and fix in replacement of heavy duty Mild Steel powder coated wall mount bracket with grouting bolts complete set suitable for wall mounting of outdoor unit of 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. |
| 39 | Supply and fix in replacement of PVC drain pipe 1/2'' size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 40 | Supply and fix in replacement of PVC drain pipe 1/2'' size including proper clamping on wall surfaces suitable for 1.5 / 2.0 TR capacity split type AC complete all as specified and directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |