| 1 | Material and Labour for dismantling the winding core of ceiling fan of 1200/1400 mm sweep size of any make/model, cutting and removing the old defective/burnt winding wire, cleaning the core of the fan motor, rewinding the motor with super enameled copper winding wire of same gauge including insulating materials, varnishing the core assembly, replacement of ball bearing & gunmetal bush as required and re-assembling the core including painting painting the ceiling fan & blade with synthetic enamel paint with pressure gun and testing complete complete all as specified and directed. |
| 2 | All as per srl item No. 01 here-in-before but for exhaust fan of 450 mm sweep size of any make/model. |
| 3 | All as per srl item No. 01 here-in-before but for exhaust fan of 380 mm sweep size of any make/model. |
| 4 | All as per srl item No. 01 here-in-before but for exhaust fan of 300 mm sweep size of any make/model. |
| 5 | All as per srl item No. 01 here-in-before but for air circulator of 225 mm sweep fan of any make/model. |
| 6 | All as per srl item No. 01 here-in-before but for air circulator of 250 mm sweep fan of any make/model. Note for Srl item Nos. 01 to 06 : Ball bearing & gunmetal bush as required shall be measured and paid for seperately as supply only. |
| 7 | Supply only ball bearing of Ceiling fan of any make/model/size complete all as specified and directed. |
| 8 | Supply & fixing in replacement ball bearing of Ceiling fan of any make/model/size complete all as specified and directed. |
| 9 | Supply only gunmetal bush of Ceiling fan of any make/model/size complete all as specified and directed. |
| 10 | Supply & fixing in replacement gunmetal bush of Ceiling fan of any make/model/size complete all as specified and directed. |
| 11 | Supply & fixing in replacement canopy of Ceiling fan of any make/model/size complete all as specified and directed. |
| 12 | Supply & fixing in replacement `U’ clamp with nuts & bolts including washers for Ceiling fan of any make/model/size complete all as specified and directed. |
| 13 | Supply & fixing in replacement of Capacitor of capacity 2.5 mfd with capacitor holding clamp, 240 volt and making connection complete all as specified and directed. |
| 14 | Supply & fixinging in replacement down rod of one feet long suitable for ceiling fan of any make/model/size complete all as specified and directed. |
| 15 | Supply and fixing in replacement down rod of two feet long suitable for ceiling fan of any make/model/size complete all as specified and directed. |
| 16 | Supply & fixinging in replacement rubber reel with safety pin for ceiling fan of any make/size/model complete all as specified and directed |
| 17 | Supply & fixing in replacement Ceiling fan 1200 mm Sweep 230 volts single phase ,50 Hz AC, complete with blades,down rod, electronic regulator, accessories (i.e. PVC canopy, rubber bush, split pin, hanging clamp, fan hook, holdfasteners etc.) white colour, with min air delivery 210 CFM, BEE 5 star rated with brushless direct current motor (BLDC) technology and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to ceiling fan complete all as specified and directed. |
| 18 | Supply & fixing in replacement exhaust fan, heavy duty, steel body AC single Phase, 230V of size 300 mm sweep, with blades and frame and louvers complete of grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed. Note : The cost of making hole in the existing wall/window and making good the disturbed surface of wall / ceiling etc. as original i.e. brick work, plastering, white washing etc. as required shall be deemed to be included in the quoated rate and no extra payment shall be made to contractor on this account. |
| 19 | Supply & fixing in replacement PVC body fresh air fan of sweep 225/250 mm heavy duty complete with self closing louvers, mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase, 50 Hz, AC supply with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.0076 mm and making all necessary connection and fixed by using suitable size bolts, nuts and washers and grouted in wall in cement mortar 1:3 completed all as specified and directed. Note : The cost of making hole in the existing wall/window and making good the disturbed surface of wall / ceiling etc. as original i.e. brick work, plastering, white washing etc. as required shall be deemed to be included in the quoated rate and no extra payment shall be made to contractor on this account. |
| 20 | Supply & fixing in replacement exhaust fan, heavy duty, steel body AC single Phase, 230V of size 450 mm sweep, with blades and frame and louvers complete of grouted to wall with suitable bolts, nuts etc., and connecting up with & including 3 core flexible copper conductor cable from ceiling rose to exhaust fan including cutting hole suitable for fixing exhaust fan complete all as specified and directed. Note : The cost of making hole in the existing wall/window and making good the disturbed surface of wall / ceiling etc. as original i.e. brick work, plastering, white washing etc. as required shall be deemed to be included in the quoated rate and no extra payment shall be made to contractor on this account. |
| 21 | Supply & fixing in replacement Wall-mounted fans 400 mm sweep , 230 Volts single phase, 50 Hz, AC mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase, 50 Hz, AC supply with and including two core PVC insulated, PVC sheathed copper conductor flexible cable 24/ 0.0076 mm and making all necessary connection and fixed by using suitable size bolts, nuts and washers and grouted in wall in Cement Mortar 1:3 completed all as specified and directed.Note for srl item No. 17 to 21 : The Old retrived material will be deposited to AGE E/M Store. |
| 22 | Supply & fixing MCB single pole, 240 volts, 6 to 32 Amp, rupturing capacity 10 kA, complete all as specified and directed. |
| 23 | Supply & fixing MCB single pole, 240 volts, 40 Amp, rupturing capacity 10 kA, complete all as specified and directed. |
| 24 | Supply & fixing MCB SPN, 240 volts, 32 Amp, rupturing capacity 10 kA, complete all as specified and directed. |
| 25 | Supply & fixing MCB TP, 415 volts, 25 to 63 Amp, rupturing capacity 10 kA, ‘ complete all as specified and directed. |
| 26 | Supply & fixing in replacement sheet metal enclosure for DB’s (Double door type), single pole and neutral, 12 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection and removal old complete all as specified and directed. |
| 27 | Supply & fixing in replacement sheet metal enclosure for DB’s (Double door type), single pole and neutral, 4 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection and removal old complete all as specified and directed. (for Offrs Servant qtrs) |
| 28 | Supply & fixing in replacement metal enclosure for DB’s (Double door type), triple pole and neutral, 6 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection and removal old complete all as specified and directed. (for Offrs Md Accn) |
| 29 | Supply & fixing in replacement metal enclosure for DB’s (Double door type),SPN 8 ways with 200 ampere rated bus bar, 240 volts fixed sunk / flush to the wall with IP-43 and IK-09 protection and removal old complete all as specified and directed. (for Offrs Md Accn) |
| 30 | Supply & fixing in replacement loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 6 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, and removal old complete all as specified and directed. |
| 31 | Supply & fixing in replacement loadline distribution board, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, double door, VTPN 4 way, 415 volts grade with insulated rated bus bar assembly with isolated neutral bar,door earthing, earth bar IP- 43 protection with poly urithene (PU) gasketing, IK-08 Mechanical impact resistance, door earthing flush to wall, including testing suitable for fixing MCCB, MCB TPN/TP/SPN/SP etc, and removal old complete all as specified and directed. |
| 32 | Supply & fixing in replacement MCCB triple pole and neutral (four pole) 40 Amps, 415 volts, 50 Hz, and breaking capacity 16 kA including making incoming and outgoing connections and removal old complete all as specified and directed. |
| 33 | Supply & fixing in replacement MCCB triple pole and neutral (four pole) 63 Amps, 415 volts, 50 Hz, and breaking capacity 16 kA including making incoming and outgoing connections and removal old complete all as specified and directed. |
| 34 | Supply & fixing in replacement MCCB triple pole and neutral (four pole) 100 Amps, 415 volts, 50 Hz, and breaking capacity 16 kA including making incoming and outgoing connections and removal old complete all as specified and directed. Please Enable Macros to View BoQ information |