| 1 | Taking down cement or cement lime plaster or grit finish plaster of any description on any walls, etc including raking out joints, hacking for key, scrubbing down with water, etc. up to Four storey height of bldg complete all as specified and directed. |
| 2 | Taking down cement or cement lime plaster or grit finish plaster of any description on any walls etc including raking out joints, hacking for key, scrubbing down with water, etc. from five to eight storey portion of bldg complete all as specified and directed. |
| 3 | Taking down cement or cement lime plaster or grit finish plaster of any description on any walls etc including raking out joints, hacking for key, scrubbing down with water, etc. from nine to twelve storey portion of bldg complete all as specified and directed. |
| 4 | Material and Labour for rendering 15mm thick plaster on fair faces of brickwork or concrete surfaces in CM 1:4 finished even and smooth without using extra cement up to Four storey height bldg complete all as specified and directed. |
| 5 | Material and Labour for rendering 15mm thick plaster on fair faces of brickwork or concrete surfaces in CM 1:4 finished even and smooth without using extra cement from five to eight storey portion of bldg complete all as specified and directed. |
| 6 | Material and Labour for rendering 15mm thick plaster on fair faces of brickwork or concrete surfaces in CM 1:4 finished even and smooth without using extra cement from nine to twelve storey portion of bldg all as specified & directed. |
| 7 | Material and Labour for preparation of new or previously untreated plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm, over and including 2mm thick wall care putty on wall up to four storey height building complete all as specified and directed by Engineer-in-Charge.Note - The work shall be executed from authorized applicator of paint manufacturer and the materials shall be approved by Garrison Engineer before execution of work. |
| 8 | Material and Labour for preparation of new or previously untreated plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 2mm thick wall care putty on wall from five to eight storey portion of building complete all as specified and directed by Engineer-in-Charge.Note - The work shall be executed from authorized applicator of paint manufacturer and the materials shall be approved by Garrison Engineer before execution of work. |
| 9 | Material and Labour for preparation of new or previously untreated plastered surfaces of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 2mm thick wall care putty on wall from nine to twelve storey portion of building complete all as specified and directed by Engineer-in-Charge.Note - The work shall be executed from authorized applicator of paint manufacturer and the materials shall be approved by Garrison Engineer before execution of work. |
| 10 | Material and Labour for complete removal of existing surface of wall and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 2mm thick wall care putty on wall up to nine storey height building complete all as specified and directed by Engineer-in-Charge. |
| 11 | Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed |
| 12 | Supply and fixing of 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls up to nine storey building etc complete all as specified and directed. |
| 13 | Supply and fixing of 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls up to nine storey building etc complete all as specified and directed. |
| 14 | Supply and fixing of Stack clamps made out of 50 mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 110mm bore PVC pipe up to nine storey height building as per complete all as specified and directed. |
| 15 | Supply and fixing of Stack clamps made out of 50 mm by 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm bore PVC pipe up to nine storey height building as per complete all as specified and directed. |
| 16 | Supply and fixing of PVC (SWR) bends any radius of 110mm bore up to nine storey height building complete all as specified and directed. |
| 17 | Supply and fixing of PVC (SWR) bends any radius of 75mm bore up to nine storey height building complete all as specified and directed. |
| 18 | Supply and fixing 110mm bore PVC (SWR) Junction single, (Single T), equal or unequal, provided with access door complete up to nine storey height building all as specified and directed. |
| 19 | Supply and fixing 75mm bore PVC (SWR) Junction single, (Single T), equal or unequal, provided with access door complete up to nine storey height building all as specified and directed. |
| 20 | Supply and fixing 110mm bore PVC (SWR) Junction double, (Double T), equal or unequal, provided with access door complete up to nine storey height building all as specified and directed by Engr In Charge. |
| 21 | Supply and fixing 75mm bore PVC (SWR) Junction double, (Double T), equal or unequal, provided with access door complete up to nine storey height building all as specified and directed by Engr In Charge. |
| 22 | Supply and fixing 110 mm PVC (SWR) Branch piece, double (Double Y) equal or unequal, provided with access door up to nine storey height building all as specified and directed by Engr In Charge |
| 23 | Supply and fixing 75 mm PVC (SWR) Branch piece, double (Double Y) equal or unequal, provided with access door up to nine storey height building all as specified and directed by Engr In Charge |
| 24 | Supply and fixing PVC (SWR) vent cowl of size 110mm complete all as specified and directed by Engr In Charge. |
| 25 | Supply and fixing PVC (SWR) vent cowl of size 75mm complete all as specified and directed by Engr In Charge. |
| 26 | Taking down Chowkhats or frames with shutters (without taking off shutters from the frame) of area n. exc 1.5 sqm each complete all as specified and directed. |
| 27 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc complete all as specified and as directed by the Engineer-in-Charge. |
| 28 | Material and Labour for Brick work with sub-class ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge. |
| 29 | Material and Labour Brickwork with sub-class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr In Charge. |
| 30 | Demolition of concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr In Charge. |
| 31 | M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm stone aggregate finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engr In Charge. |
| 32 | Demolition reinforced cement concrete of roofs, floors (other than ground floors), beams, staircases, landing, chajjas, RCC Jali and similar suspended work (reinforcement cut as required to facilitate demolition) complete up to nine storey height building all as specified and directed by Engineer-in-Charge. |
| 33 | Material and Labour for Reinforced cement concrete nominal mix 1:2:4, type B-1 (using 20mm graded aggregate) as in slabs supported on walls, beams and column in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engr-In-Charge. |
| 34 | Form work to edge of concrete, flats, treads, breaks in floors, window cills, concrete railings, opening in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, slabs etc for fair finished surfaces horizontal or sloping and similar works exc 5 cm but n exc 10 cm wide complete all as specified as directed |
| 35 | Material and Labour for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire(annealed) not less than 0.9mm dia up to nine storey complete all as specified and directed by Engr In Charge. |
| 36 | Removing plant including roots by dismantling of brickwork PCC/RCC including necessary scaffolding any type in any location/position i.e roof , parapet wall near pipes etc and applying acid after removing roots for preventing the re-growth and making good of disturbed portion using PCC 1:2:4 type B-0 & 10mm thick plaster in CM 1:3, size of disturbed portion 150 x 150 x 200mm up to nine storey height building complete all as specified & directed by Engr - In - Charge. |
| 37 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed |
| 38 | Supply and fixing Mild Steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 and portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc. complete all as specified and directed |
| 39 | Supply and fixing Mild steel, plain black sheet 1.00mm thick in wall cladding, steel gates & similar work, cut to size, holes punched; including round headed screws, clout nails or rivets & fixed to wood or steel framing with plain 40mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed |
| 40 | Material and Labour for preparation of new steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats synthetic enamel paint over a coat of red oxide primer as specified and directed by Engr-in-charge. |
| 41 | Material and Labour for removing building materials to a distance of 15km, beyond the lead included in the rates, including loading, unloading and stacking at the destination complete all as specified and directed by Engineer-in-Charge. |
| 42 | Dismantling plain or corrugated steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed |
| 43 | Supply and fixing for plain galvanized iron sheet 0.8mm thick to covering of crumple/ expansion joint/gaps on vertical/horizontal surface, steeped finishing or fixing screw up to nine storey height building etc complete all as specified and directed by Engr In Charge. |
| 44 | Material and Labour for 75 mm thick PCC (1:4:8) type D2 (using 40 mm graded aggregate ) as in sub-base for receiving floor finishes etc. complete all as specified and directed. |
| 45 | Material and Labour for coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15656 -2006 of 80mm thick, M-40 grade with grey cement and pigment complete all as specified and directed. |
| 46 | Material and Labour for sand filling under floors or foundation, and receiving to interlocking tiles, complete all as specified and directed. |
| 47 | Material and Labour for Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridge/roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed Please Enable Macros to View BoQ information |