| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority : GE NEW DELHI Name of Work: REPAIR/ MAINT OF HARDSTANDING, PATH, FOOTPATH, GATE, FENCING, BOUNDARY WALL AND CONNECTED WORKS AT ABHM, ABHM ANNEXE AND VARIOUS LOCATIONS UNDER GE NEW DELHI Contract No: GE/ND-07/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Rates only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sch. itemNo. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Rs. Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Demolition of cement concrete unreinforced of any description and in any position not other wise specifically provided incling removing the unserviceable material out side the MOD land complete all as specified and directed. |
| 3 | M&L for lean concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and directed. |
| 4 | M&L for 40mm thick cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in floor finished even and smooth surface without using extra cement complete all as specified and directed. |
| 5 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour PU glossy finish , design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. |
| 6 | M&L for cement concrete chequered tiles top PU quoted glossy finish with size 300x300x22-25 mm thick with any colour, set and jointed in neat cement slurry and pointed in coloured cement to match the surfaces as in floors over and including 15 mm thick screed bed in cement mortar 1:6 including taking down old unsv tiles complete all as specified and directed. |
| 7 | S&F in repair at or near ground level factory made kerb stone of size at top 100 x 300 and bottom 300 x 150 mm and height 300mm as per Indian std solid cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 8 | M&L for preparation of new concrete, wall surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and directed. |
| 9 | Demolition of brick work or stone/boulder masonry including all quoins, arches, pillars, etc, built in cement mortar complete all as specified and directed. |
| 10 | M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed. |
| 11 | M&L for brick work with sub class B bricks, using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 12 | M&L for PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed. |
| 13 | M&L for extra forming fair finished drain on channel 30 m inner girth in cemenjt concrete using extra cement including forms, moulds mitered/ stopped ends etc complete all as specified and directed. |
| 14 | Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc complete all as specified and directed. Note : For adjustment of rate only against item No 12.00 here-in-before |
| 15 | M&L for PCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) as in coping including weathering, slightly rounded or chamfered angles and throating, as directed and necessary form work complete all as specified and directed. |
| 16 | M&L for 15 mm thick rendering on fair faces of brick work or concrete surface in cement mortar 1:4 on external wall finished even and smooth (without using extar cement) complete all as specified and directed. |
| 17 | M&L for preparation of new plastered or unplastered surfaces of walls and applying three coats of white wash on walls complete all as specified and directed. |
| 18 | M&L for Preparing newly plastered surfaces of walls and applying two coats of exterior emulsion paint (Apex) over a coat of primer over 2 mm thich water proof putty complete all as specified and directed. |
| 19 | Dismantling of stone slab and tiles of any description or thickness in floors, apron, laid, dry and pointed and remove it out of MOD land complete all as specified and directed. |
| 20 | M&L for 16-18mm thick Italian Marble machine cut in floor/ steps laid over cement 20mm thick screed in CM 1:6 and jointed with grey/colour cement slurry to match the floor suface including design as per drg and specefication including cutting and polishing and laying by hightly skilled labours colour and shade shall be as per aproved by GE complete all as specified and directed. |
| 21 | All as per item No 19.00 above but for in vertical surfaces as skirting, dado etc. and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 22 | M&L for providing edge moulding to marble stone of counters vanities etc. including machine polishing to edge to give high gloss finish etc. complete all as specefied and directed. |
| 23 | M&L for machine cut Kota stone slab flooring, riser, trade 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor/stair including grinding, rubbing and polishing and exposed edges of Kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM 1:6 finished even and rough complete all as specified and directed. |
| 24 | All as per item No 22.00 above for in vertical surfaces as skirting, dado etc. and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed. |
| 25 | M&L for Udaipur green marble work 18 to 20mm thick (table rubbed and polished) in steps, riser/skirting, jambs, pillars, window cills, floor, and like including including 20mm thick screed bed in CM 1:6 and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade including rounded edges with shade of Udaipur green complete all as specified and directed. |
| 26 | All as per Item No 24.00 above but in vertical surfae and 10mm thick back coat in CM 1:4 complete all as specified and directed. |
| 27 | M&L for Granite stone (mirror polished) of 16-18 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the floor including grinding, rubbing and polishing and any colour as approved by Engr in charge and exposed edges of stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM 1:6 finished even and rough complete all as specified and directed. |
| 28 | M&L for 16-18 mm thick granite stone any colour as approved by Engr in charge machine cut at vertical surface, bedded and jointed with grey cement slurry and pointed with white cement with admisture of pigment to match the shade of granite stone including grinding and polishing and including rounded edges with shade of granite complete and including rendering 15mm thick in cement mortar 1:3 finished even and rough complete all as specified and directed. |
| 29 | M&L for 20-25mm thick Dholpur stone cladding gang saw cut with machine cut edges, uniform colour of each stone size exceeding 0.25 sqm area and not exc 0.5 sqm fixed with and including one number SS clamps (Grade 202) of flat 30mm x 2mm, making V groove at top and bottom of stone and filling hole for hold fastener, polishing, rubbing and including silicon treatment over 15 mm thick backing layer in CM 1:4 complete all as specified and directed by Engr in charge.Note: Size and colour of stone to be matched with existing stone |
| 30 | Dismantling wrought iron or mild steel work of any description and any positions not other wise provided for complete all as specified and directed. |
| 31 | S&F mild steel framed work such as grills, grating Y angle etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specefied and directed. |
| 32 | S&F of mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc complete, drill for fixing of steel sheeting or other covering etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting and also fastening and fixing Grade of steel Fe-410W (E-250 quality -A) complete all as specified and directed. |
| 33 | M&L steel work as in hand rails, wind ties for roof including securing bolts, posts and struts in fencing including cutting top to shape as directed drilling holes, notching for wire etc flat iron fillets for securing wire mesh etc including all necessary drilling bolting or riveting etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed. |
| 34 | S&F structural mild steel work as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framingetc (beam, tee, angle, channel or flat section) including distance pieces, cleats etc confirming to Fe 410-W (Gde 250 quality A) complete all as specified and directed. |
| 35 | M&L for preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 36 | Dismantling of plain or corrugated any type of roof sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed. |
| 37 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 38 | S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws all as specified and directed by Engr-in-Charge. |
| 39 | S&F colour or transparent (as directed by engr in charge) Polycarbonate Sheets ‘H’ pattern multiwall of 10mm thick and wall 1 mm nominal thickness, excellent physical properties of polycarbonate, UV surface protection, min 20 % light transmission,high impact resistance, weather resistant, High heat and sound insulation, Long life span, Temperature resistant- between -20°C +100°C, light-weight, superb thermal suitable for Roofing, Shedding, walling etc fixing with MS frame structure with self tapping stainless steel screw with rubber/polycarbonate washer and all joints shall be filled with silicone jel all as specified by manufacture complete all as specified and directed. |
| 40 | S&F aluminum strip for polycarbonate sheet pressure and closures of size 40mm wide section on roof/wall as it forms a weatherproof seal to the end of the sheets preventing water ingress and aids in maximum lifespan of the polycarbonate sheets alongwith rubber bids in groves of aluminum strips with self-tapping stainless steel screw with rubber/ polycarbonate washer as per manufactures instructions complete all as specified and directed. |
| 41 | M&L in repair for multi layer POP false ceiling in steps (in layers) as per drawing and as dircted by GE at site with horizontal and vertical GI frame work (Size at corner 25 x 25 x 1.2mm and others 40mm x 1.2mm) and fiber/mess reinforcement as required including putty work for finishing smooth. Painting with plastic plastic emulsion paint in two coats over primer over fininshed POP surface with suitable arrangement for Spot light/ ceiling light as per drawing/ picture complete all as specified and directed. |
| 42 | M&L in repair for Semi circular of width 15 to 25 mm and depth 15 to 25mm of each line of multilines POP work at wall as per drawing and as dircted by GE including prepartion of existing wall surface and putty work for finishing smooth. Painting with plastic plastic emulsion paint in two coats over primer over fininshed POP surface as per drawing/ picture complete all as specified and directed. |
| 43 | M&L in repair for rectangular of width 100mm and depth 25 to 35 mm POP work at wall as per drawing including prepartion of existing surface wall and as dircted by GE including putty work for finishing smooth. Painting with plastic plastic emulsion paint in two coats over primer over fininshed POP surface as per drawing/ picture complete all as specified and directed. |
| 44 | Dismantling of wall jali/ board of any type and shape with frame work and prepared the surface complete all as specified and directed. |
| 45 | S&F CNC Cut design as approved by GE at 18 mm thick WPC board, factory made, moisture free, water proof, external uses fixed to WPC frame work at vertival and ceiling as required as site with stainless Steel screw full body threaded/butt hinges of required size over suitable multi coat of high-water resistance and is very durable, glosy deco paint as per direction of Engineer -In-Charge, and as per drg/ picture complete all as specified and directed.Note : Frame work shall be measured and paid separately |
| 46 | S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and nontoxic additives ( max toxicity index of 12 for 100 gms) fabricated with meter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge complete all as specified and directed.Note: For WPC solid door/windows frames, minus 5mm tolerance in dimension i.e., depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made. |
| 47 | Dismantling of PVC wall/ceiling panel of any type and shape with frame work and prepared the surface complete all as specified and directed. |
| 48 | S&F PVC Fluted Wall/ ceiling panel of size 125x 25mm square and 3mm thick holow tongue and grove type of multi colour as directed by GE for commercial uses panel suitably placed in wall/ceiling with 30-40mm width galvanised wall panel buckles with SS screw complete all as specified and directed. |
| 49 | S&F PVC 3 to 5 mm thick Wall/ ceiling panel square and 0.9mm thick holow tongue and grove type of multi colour as directed by GE for commercial uses panel suitably placed in wall/ceiling with 30-40mm width galvanised wall panel buckles with SS screw complete all as specified and directed by Engg in charge. |
| 50 | S&F UV marble panel of 6 to 8 mm thick for wall/ceiling of multi colour as directed by GE for commercial uses panel suitably placed in wall/ceiling with 30-40mm width galvanised wall panel buckles with SS screw complete all as specified and directed. |
| 51 | S&F in reair stainless steel letters or any symbol of font \\"Arial\\" or any other font as approved user in size 50cm x 30cm of SS grade 304 with PVC box for backlid LED behind letter Plate along with Laser cutting. The latter plate comes with adhesive or SS Clit with ss screw fix to MS/ SS/ ACP/ wooden/ Composite panel/ Concrete surface/panel for sign board or similar work. The latter and front to be provided complete all as specified and directed by engr in charge. Details of material as under :-The material used – SS – 304.The cutting is done through CNC Laser technology, as a result the latter/work will have fine & smooth edges.Branded weather proof LED are to be used. The light is fixed on back of the plate in such way that it is not visible from front.The letter/word shall be Weatherproof. It can be placed outside board or places as directed.1.2mm thick stainless steel shall be provided.Thickness of PVC backlid 2mm or as per manufacture direction which is more thick.All LED connection shall be done in proper manner as per manufacture direction and 5 meter main wire for connection the letter board. |
| 52 | S&F 4mm thick ACP plain sheet colour as approved by Engr in charge for exterior use including aluminium screw, joint filling material, silicon as recommended by manufacturer fixed to metallic frame work complete all as specified and directed.Note: Metallic frame work shall be measured and paid under relevant items. |
| 53 | S&F 16MM thick fluted WPC plain/ design sheet in verious colour for exterior use including aluminium frame work with clits, screw with with MS frame 40x25x1.8mm thick @ 900x900mm incl aplying two coats of synthetic enamel paint over a coat of red oxide prime with preparation of new MS frame complete all as specified and directed. |
| 54 | S&F plain/ tiny holes white Calcium Silicate Ceiling Tiles of size 595x595x6mm, Fire Resistance, Light Reflectance more than 80%, Thermal Conductivity, Humidity Resistance, less weight not more than 5 Kgs/m2 as in false ceiling with staples on aluminium powder coated snap grid complete all as specified and directed. |
| 55 | S&F Powder coated aluminium snap gridframe work for false ceiling of size 600x600mm complete all as specified and directed.Note: The subject work shall be carried out as per drawings/ concept pictures as and when required during execution and rate of items shall be quoted according and as per direction of Engg in charge. Note: (a) Srl Item No 02.00, 04.00, 05.00, 10.00, 19.00, 24.00 to 28.00, 30.00 to 33.00, 36.00, 38.00, 44.00, 45.00 & 47.00 to 54.00 of BOQ are major items for the subject tender and material in respect of these items shall be procured within one month after placing of work order and produced before Engg in Charge alongwith original purchase vouchers as per direction of Garrison Engineer and shall obtain a certificate from Engg in charge that material in respect of above mentioned items have been submitted in the office of Engg in charge in their safe custody.(b) Materials in respect of Freakishly low declared items if any at the time of acceptance of contract shall be procured within one month after placing of work order and submit the same in the office of Engg in charge alongwith original purchase vouchers in their safe custody and shall obtain a certificate from Engg in charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |