| 1 | Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc,.complete all as spd and directed by Engineer-in- charge.Note : Including removal demolished/excavated material out of defence line and dumped at govt approved dumping area and no extra payment will be made to contractot against the same. |
| 2 | M&L for Brick work with sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete, all as specified. |
| 3 | All as per description of serial item No 2 above but except bricks.complete all as spd and directed by Engineer-in- charge. |
| 4 | Taking down cement plaster of existing wall/ceiling in any thickness including racking out joint hacking for key scrubing down with water etccomplete all as spd and directed by Engineer-in- charge. |
| 5 | M&L for Rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as spd and directed by Engineer-in- charge. |
| 6 | Demolition of cement concrete in ground floors and paving (un reinforced) including Tiles Pavings blocks if any n exc. 15 cm. thicknesses, below or above ground level, complete all as spd and directed by Engineer-in- charge..Note : Including removal demolished/excavated material out of defence line and dumped at govt approved dumping area and no extra payment will be made to contractot against the same. |
| 7 | M&L for 100mm thick PCC 1:2:4 type B-1(Using 20 mm graded crushed stone aggregate) as in floor,hard standing surfaces finished even and smooth without using extra cement laid in alternate panel including use and waste of formwwork fair or rounding or chamfered of exposed edges complete all as spd and directed by Engineer-in- charge. |
| 8 | M&L for PCC 1:4:8 type D-2(40 mm graded stone agg) as Foundation, Filling, mass concrete , bed of drains, base concrete etc complete all as spd and directed by Engineer-in- charge. |
| 9 | M&L for PCC 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in bed blocks, coping, cills, steps, kneelers, bed plates, apex stones kerbs and similar work including necessary form work complete all as spd and directed by Engineer-in- charge. |
| 10 | M&L for PCC 1:3:6 type C-2 (40 mm graded stone agg) as in surface channels and drainscomplete all as spd and directed by Engineer-in- charge. |
| 11 | Demolition of cement concrete in ground floors and paving ( reinforced) n exc. 15 cm. thicknesses, below or above ground level,complete all as spd and directed by Engineer-in- charge.Note : Including removal demolished/excavated material out of defence line and dumped at govt approved dumping area and no extra payment will be made to contractot against the same. |
| 12 | S&F for factory made Precast RCC Drain ( M-30 Grade) laid and jointed complete with collars bore of same precast drain ,fixed with joint material as per proper follow manufacturer instruction including cost of TMT bars used complete all as specifiedand as directed by Engr-In-Charge. Drain size will be as per instruction of Engr in Charge.Note : Placing of Precast reinforced concrete drain will be trough proper maintened gradient/slope due to which the water flow should be at its minimum flow. Department shall not make any claim to the contractor for scaffolding or any other equipment. |
| 13 | M&L for RCC 1:2:4 type B-1 (20 mm graded stone agg) as in slabs, similar suspended work including necessary form work etc complete. etccomplete all as spd and directed by Engineer-in- charge. |
| 14 | M&L for factory made Precast RCC (M-30) cover slab fo man holes etc including form work and TMT bars complete all as spd and directed by Engineer-in- charge. |
| 15 | M&L for TMT steel bars 10mm dia and over cut to length bent to shape required including crancking bending spirally for hooping to columns hooking ends and binding with mild steel wire (annealed) n. less than 0.90mm dia .complete all as spd and directed by Engineer-in- charge. |
| 16 | Dismantling existing unservicable floor tiles of any description including bedding/screed layer complete all as spd and directed by Engineer-in- charge.Note : Including removal demolished/excavated material out of defence line and dumped at govt approved dumping area and no extra payment will be made to contractot against the same. |
| 17 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; all as specified and directed by Eng-in charge.Note:- Before execution of above mentioned item it is compulsary to make good the existing surface of PCC so that paver block could be fixed properly and no extra cost will be bourne by department. |
| 18 | M&L for Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. all as specified and directed by Eng-in charge |
| 19 | Dismantling posts or struts (wood, Steel or RCC) any section, including takingout embedded portion and making good distrubed gound etc .complete all as spd and directed by Engineer-in- charge.Notes:-Demolished material should be thrown out of the defence line including loading,transportation,unloading of debris at govt approved dumping area.Also no extra cost shall be paid to the contractor by department. |
| 20 | Excavation in post holes (or similar holes) each not exc 0.5cum getting out in any type of soil, returning, filling in and ramming earth or broken rubber mixed with earth around in layers not exc 15cm.complete all as spd and directed by Engineer-in- charge. |
| 21 | S&F MS work as in Post and Struts in fencing including cutting tops to shape as directed drilling holes nothing for wire etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolts or riveting etc and similar work.complete all as spd and directed by Engineer-in- charge. |
| 22 | M&L Mild Steel sections confirming to FE-410-W as in Framed work as in doors, gates of angles or other section with gusset plates, rails etc including necessary cutting, drilling, welding etc complete all as per directed by Engr- in charge and any type of ornament pattern and design as approved by GE.Note:-1.Contractor shall not have any claim in respect of design/Ornamental shape/designer member,the differnece of rate and amount of desinger pattern will not be paid by Department. |
| 23 | S&F galvanised 2nd stand steel wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provn of galvanised mild steel wire staples or steel pins etc complete all as spd and directed by Engineer-in- charge. |
| 24 | S&F 4mm dia galvanised steel wire chain link fencing size 75x75mm mesh including line wires any mesh size and type to any type or standards, rails, straining bolts etc including provision of binding wire including dismantling old uncerviceable chain link fencing any type any size complete all as spd and directed by Engineer-in- charge. |
| 25 | S&F,concertina coil fencing with punch tape concertina coil 650mm dia, strached to 6.0 meter length, having 50 nos sprial turns per 6.0 meter length, spring core wire (2.59mm thick) of high rensile strength of 1620 N/sqm with tape (0.52mm thick) hot dip galvanised upto 20 micros and weight of each coil 10 to 12 Kg and fixing the same on Y shaped angle iron 8 horizontal R.B.T ( Reinforced barbed tape ) stud tied with GI staple sand GI clips to retain horizontal clips shall be @5 Nos per 2 sprial turns approximate 125 clips per coil including necessary bolts cinokete aklk and removing as specified and as directed. Note: for measurement purpose overall lenght of the wire shall be measured) the get approved by AGE before procurment. |
| 26 | M&L for Preparation of new or untreated steel surface of any description exc. 10 cm. in width or girth and applying two coats of synthetic enamel paints, over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-charge. |
| 27 | M&L for Preparation of new plastered surfaces and applying two coats of exterial emulsion paint on walls including a thin layer of wall care putty,necessary formwork scaffolding required upto the 4th story complete all as spd and directed by Engineer-in- charge. |
| 28 | Dismantling of asbestos cement sheets, corrugated or semi corrugated etc in roof covering complete and set a side.complete all as spd and directed by Engineer-in- charge. Notes:-Demolished material should be thrown out of the defence line including loading,transportation,unloading of debris at govt approved dumping area.Also no extra cost shall be paid to the contractor by department. |
| 29 | S&F in repairs Pre-painted galvalume aluminium zinc coated corrugated sheet (including pre-laminated guard film) 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws.complete all as spd and directed by Engineer-in- charge. |
| 30 | S&F in repair 08 mm thick Poly-Carbonate UV protected hollow sheet with side lap fixed with coach screw and washer in roof, wall etc, fixed with self tapping screws.complete all as spd and directed by Engineer-in- charge. |
| 31 | Removal of demolished debris /excavated soil not exc 50 m and deposit out of defence line at govt approved dumping area including loading,unloading and transportation etc at a level n. exc 1.5 m above the starting pointcomplete all as spd and directed by Engineer-in- charge. |
| 32 | SCHEDULE 'A' PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch 'A' Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder. Please Enable Macros to View BoQ information |